MODEL 361AAN UPFLOW-HORIZONTAL OIL FURNACE
A93211
The 361AAN Furnace is designed for top performance to provide years of reli-
able, comfortable home heating.
The 361AAN is an upflow/horizontal oil furnace that can be installed upflow, hor-
izontal right, or horizontal left for greater application coverage. The flue exits the
front of the furnace. The heat exchanger is backed by a Limited Lifetime Warranty.
FEATURES
INSTALLATION FLEXIBILITY
—The 361AAN installs in upflow, horizontal right,
or horizontal left positions for greater application coverage and installation flexi-
bility.
HEAT EXCHANGER
—The stainless steel primary and aluminized steel second-
ary heat exchangers are designed for outstanding reliability backed by a Limited
Lifetime Warranty. The heat exchanger utilizes crimped seams instead of welds
for corrosion resistance. All internal surfaces are accessible for any field mainte-
nance without removing the heat exchanger.
CLEANOUT PORTS
—Allow easy cleaning of secondary heat exchanger tubes
without disassembly of the furnace or heat exchanger.
CONTROLS
—The Beckett oil burner is equipped with an electronic primary relay
for added reliability. Integrated fan timer control board with low-voltage terminal
strip and 40-va transformer make air conditioning installation easy.
HEAVY DUTY BLOWER
—Blower motors are PSC type and 3 speed. The direct-
drive blowers eliminate belt adjustments in the field. The constant low-speed
blower switch provides air circulation during “off cycles for indoor air filtration.
DURABLE CABINET
—The casing is constructed of prepainted steel for years of
attractiveness. Filter and filter rack are provided with each furnace.
SPECIFICATIONS
* Capacity and AFUE in accordance with U.S. Government DOE test procedures.
Permissible limits of the voltage range at which the unit will operate satisfactorily.
Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.
** Time-delay fuse is recommended.
ICS—Isolated Combustion System
UNIT SIZE 036075 036105 048125 060155
RATINGS AND PERFORMANCE
Firing Rate 0.50 0.76 0.90 1.12
Input (Btuh) 72,000 105,000 125,000 154,000
Heating Capacity (Btuh)* 55,000 85,000 100,000 125,000
AFUE %* ICS 80.0 80.7 81.5 80.3
Oil Pump Stages 1
Heating Temperature Rise
°
F 55—85
Recommended Heating Blower Speed Low Medium Medium High
Cooling CFM @ 0.5-in. wc Static Pressure 1255 1365 1745 1935
Heating CFM @ 0.2-in. wc Static Pressure 850 1425 1645 2170
ELECTRICAL
Unit Volts—Hertz—Phase 115—60—1
Operating Voltage Range† 104—127
Rated Load Amps 12.55 12.55 15.65 16.15
Minimum Ampacity for Wire Sizing 14 14 18 19
Minimum Wire Size AWG 14 14 12 12
Maximum Wire Length (Ft)‡ 26 26 32 30
Maximum Fuse Size (Amps)** 15 15 20 20
Control Transformer (24v) 40va
External Control Power Available Heating 35va
Cooling 35va
Burner Model (3450 RPM) Beckett AFG
BLOWER DATA
Motor HP 1/3 1/3 1/2 3/4
Blower Wheel Size (In.) 10 x 9 10 x 9 12 x 9 12 x 12
Blower Motor Speed and Type 1075 PSC Direct
Filter Quantity and Size (1) 20-1/8 x 25 x 1 (1) 20-1/8 x 30 x 1
https://manual-hub.com/
—3—
DIMENSIONS—MODEL 361AAN
A96306
DIMENSIONS (In.)
* Filter rack provides transition from duct size to opening size.
† Duct sizes are ID dimensions for slipping over filter rack.
‡ Outlet of heat exchanger and elbow shipped with furnace is 6 in. Flue pipe may be reduced to 5-in. diameter for vent sizing.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)
* Floor may be combustible.
AIR DELIVERY—CFM (Without Filters)
UNIT
SIZE SHIP.
WT (Lb)
UNIT DIMENSIONS DUCT SUPPLY
OPENING FLUE
DIAMETER SIDE RETURN
OPENING*
END (BOTTOM)
RETURN
OPENING SIDE RETURN
DUCT SIZE†
END (BOTTOM)
RETURN DUCT
SIZE†WIDTH DEPTH HEIGHT
ABCDE F GHJKLMNP
036075 215 22 30-1/2 48 20 17 6‡ 15 25-1/4 20-1/8 17-1/16 18-1/4 25-1/4 20-1/4 25-1/4
036105 228 22 30-1/2 48 20 17 6‡ 15 25-1/4 20-1/8 17-1/16 18-1/4 25-1/4 20-1/4 25-1/4
048125 254 22 35-1/2 48 20 22 6‡ 15 30-1/4 20-1/8 22-1/16 18-1/4 30-1/4 20-1/4 30-1/4
060155 265 22 35-1/2 48 20 22 615 30-1/4 20-1/8 22-1/16 18-1/4 30-1/4 20-1/4 30-1/4
UNIT APPLICATION UPFLOW HORIZONTAL
SIDES—Furnace 02
Supply Plenum and Warm-Air Duct Within 6 ft of Furnace 1 1
BACK 00
TOP—Furnace Casing or Plenum 2 2
Horizontal Warm-Air Duct Within 6 ft of Furnace 2 3
BOTTOM 0* 0*
FLUE PIPE—Horizontally or Below Pipe 4 4
Vertically Above Pipe 8 8
FRONT 824
UNIT
SIZE
BLOWER
MOTOR
HP SPEED EXTERNAL STATIC PRESSURE IN. WC
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
036075 1/3 PSC High 1530 1475 1410 1340 1255 1170 1075 970 855 705
Medium 1240 1200 1150 1110 1065 1000 920 830 705 555
Low 870 850 830 805 765 720 660 590 480 360
036105 1/3 PSC High 1635 1560 1500 1425 1365 1260 1165 1040 945 785
Medium 1470 1425 1365 1290 1220 1140 1030 935 825 695
Low 1280 1245 1205 1145 1085 1010 935 835 710 590
048125 1/2 PSC High 1965 1915 1865 1805 1745 1665 1590 1515 1445 1345
Medium 1695 1645 1615 1565 1530 1465 1410 1335 1255 1165
Low 1340 1330 1320 1290 1270 1215 1180 1125 1045 990
060155 3/4 PSC High 2240 2170 2085 1980 1935 1820 1750 1665 1590 1510
Medium 2000 1965 1890 1795 1755 1690 1625 1555 1480 1375
Low 1535 1495 1450 1420 1365 1330 1275 1205 1125 1035
J
N P
B
E
M
D
A
F
OIL INLET 7/8-IN.
DIA (2 PLACES)
BOTH SIDES
ELECTRICAL
CONNECTIONS
(TOP) 1/2-IN. DIA
BOTH SIDES
(BOTTOM) 7/8-IN.
DIA BOTH SIDES
H
B
K
G
KNOCK-OUT BOTH SIDES
FOR SIDE FLUE
C
E
21 916
13 916
2
12 116
1
1
1
3
116
2916
4
ALTERNATE
OIL INLET
THROUGH SLOTS
L
SIDE
RETURN
AIR DUCT
END RETURN
AIR DUCT
SIDE
RETURN
AIR DUCT
11 1516
CLEANOUT
PORTS
https://manual-hub.com/
—4—
MODEL 362AAN LOW-BOY OIL FURNACE
A96358
The 362AAN Furnace is designed for top performance to provide years of reli-
able, comfortable home heating.
The 362AAN is a Low-Boy style oil furnace that can be installed in limited over-
head areas for greater application coverage. The heat exchanger is backed by a
Limited Lifetime Warranty.
FEATURES
LOW-BOY CABINET STYLE
—The 362AAN allows easy installation in low over-
head areas such as crawlspaces and sub-basements.
HEAT EXCHANGER
—The stainless steel primary and aluminized steel second-
ary heat exchangers are designed for outstanding reliability backed by a Limited
Lifetime Warranty. The heat exchanger utilizes crimped seams instead of welds
for corrosion resistance. All internal surfaces are accessible for any field mainte-
nance without removing the heat exchanger.
CLEANOUT PORTS
—Allow easy cleaning of secondary heat exchanger tubes
without disassembly of the furnace or heat exchanger.
CONTROLS
—The Beckett oil burner is equipped with an electronic primary relay
for added reliability. Integrated fan timer control board with low-voltage terminal
strip and 40-va transformer make air conditioning installation easy.
HEAVY DUTY BLOWER
—Blower motors are PSC type and 3 speed. The direct-
drive blowers eliminate belt adjustments in the field. The constant low-speed
blower switch provides air circulation during “off cycles for indoor air filtration.
DURABLE CABINET
—The casing is constructed of prepainted steel for years of
attractiveness. Filter provided with each furnace.
* Capacity and AFUE in accordance with U.S. Government DOE test procedures.
Permissible limits of the voltage range at which the unit will operate satisfactorily.
Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.
** Time-delay fuse is recommended.
ICS—Isolated Combustion System
UNIT SIZE 036105 048125 060155
RATINGS AND PERFORMANCE
Firing Rate 0.76 0.90 1.12
Input (Btuh) 105,000 125,000 154,000
Heating Capacity (Btuh)* 85,000 100,000 125,000
AFUE %* ICS 80.3 82.5 81.0
Oil Pump Stages 1
Heating Temperature Rise
°
F 55—85
Recommended Heating Blower Speed Medium Medium High
Cooling CFM @ 0.5-in. wc Static Pressure 1550 1630 1800
Heating CFM @ 0.2-in. wc Static Pressure 1335 1675 1960
ELECTRICAL
Unit Volts—Hertz—Phase 115—60—1
Operating Voltage Range† 104—127
Rated Load Amps 12.55 15.65 16.15
Minimum Ampacity for Wire Sizing 14 18 19
Minimum Wire Size AWG 14 12 12
Maximum Wire Length (Ft)‡ 26 32 30
Maximum Fuse Size (Amps)** 15 20 20
Control Transformer (24v) 40va
External Control Power Available Heating 35va
Cooling 35va
Burner Model (3450 RPM) Beckett AFG
BLOWER DATA
Motor HP 1/3 1/2 3/4
Blower Wheel Size (In.) 12 x 9 12 x 9 12 x 12
Blower Motor Speed and Type 1075 PSC Direct
Filter Quantity and Size (1) 21-1/4 x 21-1/4 x 1
https://manual-hub.com/
—5—
DIMENSIONS—MODEL 362AAN
A96309
DIMENSIONS (In.)
*Flue pipe may be reduced to 5-in. diameter on 105 and 125 sizes for vent sizing.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)
* Floor may be combustible.
AIR DELIVERY—CFM (Without Filters)
UNIT
SIZE SHIP.
WT (Lb)
UNIT DIMENSIONS DUCT SUPPLY OPENING FLUE
DIAMETER RETURN DUCTWIDTH DEPTH HEIGHT
ABCDEF GH
036105 248 22 52 33 20 17-1/4 6* 20 18
048125 269 22 57 33 20 22-1/4 6* 20 18
060155 278 22 57 33 20 22-1/4 6*20 18
UNIT APPLICATION LOW-BOY
SIDES—Furnace 0
Supply Plenum and Warm-Air Duct Within 6 ft of Furnace 1
BACK 0
TOP—Furnace Casing or Plenum 2
Horizontal Warm-Air Duct Within 6 ft of Furnace 2
BOTTOM 0*
FLUE PIPE—Horizontally or Below Pipe 4
Vertically Above Pipe 8
FRONT 8
UNIT
SIZE
BLOWER
MOTOR
HP SPEED EXTERNAL STATIC PRESSURE IN. WC
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
036105 1/3 PSC High 1795 1735 1675 1605 1550 1485 1425 1350 1275 1220
Medium 1365 1335 1305 1275 1255 1215 1155 1105 1050 985
Low 995 965 945 925 900 870 825 775 725 670
048125 1/2 PSC High 1905 1845 1770 1695 1630 1565 1490 1425 1325 1220
Medium 1750 1675 1620 1560 1500 1440 1370 1305 1235 1130
Low 1390 1350 1305 1260 1220 1180 1120 1060 985 880
060155 3/4 PSC High 2025 1960 1905 1850 1800 1655 1575 1500 1415 1315
Medium 1885 1825 1760 1705 1640 1565 1500 1430 1350 1265
Low 1555 1490 1445 1410 1350 1280 1230 1155 1085 1005
INSULATION
INTERMEDIATE
PANEL
FILTER
B
A
G
D
ELECTRICAL
CONNECTIONS
OIL INLET
F
12 116EH
1
INSULATION
PARTITION
PANEL
SUPPLY
DUCT
CLEAN-OUT PORTS
RETURN
DUCT
1
3
C
https://manual-hub.com/
—6—
MODEL 363AAP UPFLOW/HORIZONTAL OIL FURNACE
A93213
The 363AAP Furnace is designed for top performance to provide years of reli-
able, comfortable home heating. This furnace is also designed to meet the need
for large residential and light commercial markets.
The 363AAP is a large capacity upflow/horizontal oil furnace that can be installed
upflow, horizontal right, or horizontal left for greater application coverage. The flue
exits the rear of the furnace. The heat exchanger is backed by a Limited Lifetime
Warranty.
FEATURES
INSTALLATION FLEXIBILITY
—The 363AAP installs in either upflow, horizontal
right, or horizontal left orientation for greater application coverage and installation
flexibility.
HEAT EXCHANGER
—The stainless steel primary and aluminized steel second-
ary heat exchangers are designed for outstanding reliability backed by a Limited
Lifetime Warranty. The heat exchanger utilizes crimped seams instead of welds
for corrosion resistance. All internal surfaces are accessible for any field mainte-
nance without removing the heat exchanger.
CONTROLS
—The Beckett oil burner is equipped with an electronic primary relay
for added reliability. Integrated fan timer control board with low-voltage terminal
strip and 40-va transformer make air conditioning installation easy.
HEAVY DUTY BLOWER
—Blower motors are PSC type and 3 speed. The direct-
drive blowers eliminate belt adjustments in the field. The constant low-speed
blower switch provides air circulation during “off cycles for indoor air filtration.
DURABLE CABINET
—The casing is constructed of prepainted steel for years of
attractiveness. Filter and frame are provided with each furnace.
* Capacity and AFUE in accordance with U.S. Government DOE test procedures.
Permissible limits of the voltage range at which the unit will operate satisfactorily.
Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.
** Time-delay fuse is recommended.
ICS—Isolated Combustion System
UNIT SIZE 060210
RATINGS AND PERFORMANCE
Firing Rate 1.50
Input (Btuh) 210,000
Heating Capacity (Btuh)* 170,000
AFUE %* ICS 81.2
Oil Pump Stages 2
Heating Temp Rise
°
F 70—100
Recommended Heating Blower Speed Medium
Cooling CFM @ 0.5-in. wc Static Pressure 2145
Heating CFM @ 0.2-in. wc Static Pressure 2125
ELECTRICAL
Unit Volts—Hertz—Phase 115—60—1
Operating Voltage Range† 104—127
Rated Load Amps 16.15
Minimum Ampacity for Wire Sizing 19
Minimum Wire Size AWG 12
Maximum Wire Length (Ft)‡ 30
Maximum Fuse Size (Amps)** 20
Control Transformer (24v) 40va
External Control Power Available Heating 35va
Cooling 35va
Burner Model (3450 RPM) Beckett AFG
BLOWER DATA
Motor HP 3/4
Blower Wheel Size (In.) 12 x 12
Blower Motor Speed and Type 1075 PSC Direct
Filter Quantity and Size (1) 24-1/2 x 38-1/4 x 1
https://manual-hub.com/
—7—
DIMENSIONS—MODEL 363AAP
A96336
DIMENSIONS (In.)
*Filter rack provides transition from duct to opening size.
† Duct sizes are ID dimensions for slipping over filter rack.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)
* Floor may be combustible.
AIR DELIVERY—CFM (Without Filters)
UNIT
SIZE
SHIP
WT
(Lb)
UNIT DIMENSIONS DUCT SUPPLY
OPENING FLUE
DIAMETER SIDE RETURN
OPENING*
END (BOTTOM)
RETURN
OPENING SIDE RETURN
DUCT SIZE†
END (BOTTOM)
RETURN
DUCT SIZE†WIDTH DEPTH HEIGHT
ABCDE F GHJKLMNP
060210 385 26 42-1/2 54-3/4 24 29 7 17-3/4 37-1/4 24-1/8 29-1/16 20-1/4 38-1/4 24-1/4 38-1/4
UNIT APPLICATION UPFLOW HORIZONTAL
SIDES—Furnace 22
Supply Plenum and Warm-Air Duct Within 6 ft of Furnace 1 1
BACK 22
TOP—Furnace Casing or Plenum 2 2
Horizontal Warm-Air Duct Within 6 ft of Furnace 2 3
BOTTOM 0* 0*
FLUE PIPE—Horizontally or Below Pipe 9 9
Vertically Above Pipe 9 9
FRONT 24 24
UNIT
SIZE
BLOWER
MOTOR
HP SPEED EXTERNAL STATIC PRESSURE IN. WC
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
060210 3/4 PSC High 2485 2395 2305 2250 2145 2075 1975 1885 1780 1675
Medium 2195 2125 2060 1990 1915 1860 1785 1700 1620 1525
Low 1640 1590 1540 1515 1460 1410 1350 1275 1190 1075
OIL INLET
3
/
8
IN. DIA
(2 PLCS) BOTH SIDES
ELECTRICAL CONNECTIONS
(TOP)
1
/
2
IN. DIA BOTH SIDES
(BOTTOM)
7
/
8
IN. DIA BOTH SIDES
11
15
/
16
12
1
/
16
1
1
2
FLUE
DIAMETER
F
B
EM
AD
J
N
C
B
G
K
H
E
L
P
ALTERNATE OIL INLET
THROUGH SLOTS
REAR VIEW
CLEANOUT
PORTS
END
RETURN
AIR DUCT
CONTROL
BOX
SIDE RETURN
AIR DUCT
CLEANOUT PORTS
CLEANOUT PORTS
https://manual-hub.com/
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
Cancels: PDS 361A.75.1B
© 1997 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 PRINTED IN U.S.A. Catalog No. 5236-100 8-97
—8—
A94328
SERVICE TRAINING
Packaged Service Training programs are an excellent way to increase your
knowledge of the equipment discussed in this manual, including:
 • Unit Familiarization • Maintenance
 • Installation Overview • Operating Sequence
A large selection of product, theory, and skills programs is available, using popular
video-based formats and materials. All include video and/or slides, plus companion
book.
Classroom Service Training plus "hands-on" the products in our labs can mean
increased confidence that really pays dividends in faster troubleshooting, fewer
callbacks. Course descriptions and schedules are in our catalog.
CALL FOR FREE CATALOG 1-800-962-9212
[ ] Packaged Service Training [ ] Classroom Service Training
https://manual-hub.com/
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Bryant 361AAN User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI