Premier Mounts PCM-100 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Premier Mounts PCM-100 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PCM-100
Installation Instructions
Step 1
Invert the display and place it on a soft and flat surface. Locate the mounting points on the back of the plasma display.
Identify the correct plasma bracket mounting hardware for your plasma display from the chart shown on the back of the
assembly manual and secure the (L) Left and (R) Right hand side mounting brackets to the plasma using the
corresponding hardware (supplied). Note: Make sure the upper “clevis” hook mounting screw, nut and reference arrow
are facing to the left and right outside edges of the display.
Step 2
Determine the desired height for the bottom edge of the display on the wall.
Temporarily slide the round steel rod portion of one of the universal (WP) wall plates fully into the bottom receiving slots
of the installed plasma mounting brackets. Measure the distance between the bottom outside edge of the plasma
display and the bottom outside edge of the lower wall mounting plate. Add the desired bottom edge height of the
display to the distance between the bottom edge of the wall plate and the bottom edge of the display to determine the
correct mounting height of the lower wall plate. Example: Overall desired height for the bottom outside of the display is
60". Difference between the bottom edge of the display and the bottom edge of the lower wall plate fully installed in the
lower receiving slots of the brackets is 4" means the lower wall plate bottom outside edge should be placed at 64" from
the floor (60" + 4" = 64"). Determine the desired wall location and its ability to properly support the weight of the display.
Locate and mark the dual 16" or 24" wood stud centers closest to the desired plasma placement area. Measure up
from the floor the proper distance to the bottom edge of the lower wall plate and mark a level reference line on the wall.
Place the lower wall plate bottom edge on the reference line and mark the best four (4) each wall plate lag bolt
mounting points through the wall plate slots on the wall. Install on a level the bottom wall plate with the wall plate
reference arrow pointing up to the wall using the (4) four 5/16" Lag bolts and flat washers (supplied).
Note: The wall plate provides you with three (3) 16" stud center patterns and one (1) 24" stud center pattern to assist
you in your installation.
Step 3
With the lower wall plate securely installed and level with the floor place the “supplied” upper wall plate cardboard
placement template over the top and outside edges of the lower wall plate. Place bottom and outside edges of the
upper wall plate into the top portion of the template and mark the duplicate set of mounting points for the upper wall
plate to the wall. Secure the upper wall plate to the wall in the same manner as the lower plate using the four (4) 5/16"
lag bolts and flat washers. With the two wall plates properly secured to the wall the separation template should be used
to recheck the proper separation between the upper and lower plates.
Step 4
With the upper “clevis” tilt hooks on the plasma brackets in the flat on wall position raise the plasma display with
brackets attached (2 people minimum recommended) and place the plasma display flat against wall with the upper and
lower plasma bracket attaching slots slightly higher than the steel receiving rods of the upper and lower wall plates.
With the plasma reasonably level lower the display until the display brackets receiving slots are fully installed into the
upper and lower wall plate steel rods. Gently pull the left and right upper edges of the display to extend the mount to its
maximum 10° tilt and install finger tight the two upper “clevis” arm 6 (mm) safety knobs one on each mounting bracket.
Step 5
Once the display on wall installation is complete you still can move the display from left to right or right to left to optimize
the final position of the display on the wall by gently sliding the unit on the steel rods of the wall plate. This adjustment
distance will vary depending on the display model being installed.
NOTE: Do not over tighten the bracket mounting screws as damage to the display internal mounting threads
could occur.
Note: To remove the display from the wall simply extend the display to its maximum tilt range, remove the two
6 (mm) safety knobs push the display back to its flat wall position and lift the unit up and out from the wall.
N
OTE: Some of the hardware may be left out if all the assign mounting points on the bracket are used.
Note: The 8 (mm) nuts for your coarse tension adjustment and the 5 (mm) screws for your fine tension
adjustment.
www.touchboards.com 205 Westwood Ave.Long Branch, NJ 07740 1-866-942-6273 [email protected]
A PCM Mount Brackets L/R
B Hardware See Chart
C Nylon Spacers (SP) See Chart
D Wall Brackets 2
E Template 1
F 5/16" Lag Bolts 8
G 5/16" Flat Washers 8
H 6 mm x 12 mm Securing Knobs 2
PCM-100
Note: When the display brackets receiving slots are fully installed into the upper and lower wall plate steel rods
and the plasma is on its flat position, there is a 7/8" gap from the top of the rod to the end of the hook. This
feature is to com
p
ensate for tiltin
g
.
Note: Arrows on the wall brackets must
be facing up prior to installation. Secure
the lag bolts into the center of the wood
stud.
BRAND MODEL # MP HARDW ARE PACK
Dwin HD50 3,9 (4) 8 (m m ) x 30 (m m ) (SP) PK 2
Fujitsu 4211, 4212, 4221, 4222, 4208, 4209, 4213, 4214,
4229, 4241, 4242 2,6 (4) 5 (m m ) x 16 (m m ) PK 1
Fujitsu P42HH A10 3,9 (6) 8 (m m ) x 20 (m m ) PK 4
Fujitsu P50X H A10 3.A,11.1 (6) 8 (m m ) x 30 (m m ) PK 7
Fujitsu 5001, 5002 3,9 (4 ) 8 (m m ) x 3 0 (m m ) (S P ) P K 2
Fujitsu PD S6101 4.1,12 (4 ) 8 (m m ) x 3 0 (m m ) (S P ) P K 2
Hitachi C M P500W X U 3,5,8 (6) 8 (m m ) x 20 (m m) PK 4
JVC G D V 500PZ U 3,9 (4 ) 8 (m m ) x 3 0 (m m ) (S P ) P K 2
LG M U40PA10 4,7,10 (6) 5 (m m ) x 20 (m m) (SP) PK 3
LG M U50P241 4,6.2,10 (6) 5 (m m ) x 16 (m m ) PK 1
LG M N42PZ10, M N 42PZ11, M U42PZ10 3.1,6.1,7.1 (6 ) 5 (m m ) X 1 6 (m m ) (S P ) N o te :
Use spacers from pack 3 PK 1
LG M U60P Z10 1,5,11 (6 ) 8 (m m ) x 2 0 (m m ) (S P ) P K 4
Panasonic
TH 37PW D4UZ,PT42P1, TC42P1F, 42PD2,
PT42PD3P, PT42PD1P, TH42PW D3U, PT37P1,
TC42P1, TH42PW D3, TH42PWD4UY,
TH42PW D4EX, TH50PHD3U, PT50PD3P,
TH50PHD3E
3,9 (4) 8 (m m ) x 30 (m m ) (SP) PK 2
Eizo P 5070, P5071 3,5,8 (6) 8 (m m ) x 30 (m m ) P K 7
Pioneer PDP4330HD,PDP501X, V502MX, V502X, V505,
PDP505HD,1000HD,PDP503CMX, PDP5030HD 3,5,8 (6) 8 (m m ) x 20 (m m ) PK 4
Runco PL42cx 3,9 (4 ) 8 (m m ) x 3 0 (m m ) (S P ) P K 2
Runco PL43HDX 3,5,8 (6) 8 (m m ) x 20 (m m) PK 4
Runco PL50c 3,5,8 (6 ) 8 (m m ) x 2 0 (m m ) P K 4
Sharp P Z43HV2U ,PD50,P Z50H V2U ,PZ43H V2U 3,5,8 (6 ) 8 (m m ) x 2 0 (m m ) P K 4
Toshiba PD42W , PD42W 1 3,9 (4 ) 8 (m m ) x 3 0 (m m ) (S P ) P K 2
Toshiba 50HP81 3,9 (4 ) 8 (m m ) x 3 0 (m m ) (S P ) P K 2
Viewsonic VPW 420 3,9 (4 ) 8 (m m ) x 3 0 (m m ) (S P ) P K 2
Viewsonic VPW 500 3,5,8 (6 ) 8 (m m ) x 2 0 (m m ) P K 4
Zenith DPDP40W ,P40V22,DPDP40V 4,7,10 (6) 5 (m m ) x 2 0 (m m ) (S P ) P K 3
Zenith P 50W 26 3.2,6.2,10 (6) 5 (m m ) x 16 (m m ) PK 1
Zenith P 42W 22 3.1,6.1,7.1 (6 ) 5 (m m ) X 1 6 (m m ) (S P ) N o te :
Use spacers from pack 3 PK 1
Zenith D PD P 60W , P60W 26 1,5,11 (6 ) 8 (m m ) x 2 0 (m m ) (S P ) P K 4
AKIRA SV-4201 1,9 (4) 8 (m m ) x 30 (m m ) (SP) PK 2
Yamaha PDM1 1,9 (4) 8 (m m ) x 30 (m m ) (SP) PK 2
#/LR DESCRIPTION QTY
R.08
R
LISTED
E176225
The wall should be capable of supporting a weight of 160 Lbs at least four (4) times the weight of the plasma display. More than 160 Lbs, the wall must be reinforced. Proper
installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could result in serious personal injury.
NOTE: During installation, the cardboard template (Item E) is required for proper separation of the wall plates. Do not discard cardboard template before using.
N E W H A R D W A R E
CAUTION!
The nylon sleeves and ½” nylon spacers must ALWAYS be used in order to install plasma bracket on to
the plasma. Failure to do so will result in damaging the plasma internally. This application is required by
the plasma manufacture.
Nylon sleeves
½" Nylon spacers
ASSEMBLED
NEW HARDWARE APPLIES TO
PLASMA MODELS:
Fujitsu 50" & 61"
5001, 5002, PDS6101, PDS6001,
PDS6002,P50XCA11UH
P50XCA10WH, P50XCA10HA
P50XCA10UH,P50XCA11WH
P50XCA11AH, P50XCA12WH
P50XCA12EH, P50XCA12AH
P50XCA12UH
Panasonic 42", 50"
TC42P1, PT42PD3P, PT42PD1P,
TC42P1F, PT37P1, TH42PWD3,
TH37PWD4UZ, TH42PWD4UY,
TH42PWD4EX, PT42P1, 42PD2,
TH42PWD3U, TH50PHD3U,
PT50PD3P, TH50PHD3E,
TH50PHW3
Runco 42"
PL42cx,
Toshiba 42", 50"
50HP81, PD42W, PD42W1
ViewSonic 42"
VPW420,
Dwin 50"
HD50
JVC 50"
GDV500PZU
NOTICE APPLIES TO PCM (REV 8)
CTM (REV 8) / PSM / PRM MOUNTS.
/