G&D DVI-CPU, DVI-CON, DL-DVI-CPU, DP-CPU, DP-CON, DVI-I-CPU, VGA-CPU, U2-R-CPU, U2-R-CON Installation and Operating Guide

Category
KVM switches
Type
Installation and Operating Guide
A9200138-1.20
G&D Target and User Modules
Installation and Operation
Devices with integrated USB
EN
i · Target and user modules (USB)
About this manual
This manual has been carefully compiled and examined to the state-of-the-art.
G&D neither explicitly nor implicitly takes guarantee or responsibility for the qual-
ity, efficiency and marketability of the product when used for a certain purpose that
differs from the scope of service covered by this manual.
For damages which directly or indirectly result from the use of this manual as well
as for incidental damages or consequential damages, G&D is liable only in cases of
intent or gross negligence.
Caveat Emptor
G&D will not provide warranty for devices that:
Are not used as intended.
Are repaired or modified by unauthorized personnel.
Show severe external damages that was not reported on the receipt of goods.
Have been damaged by non G&D accessories.
G&D will not be liable for any consequential damages that could occur from using
the products.
Proof of trademark
All product and company names mentioned in this manual, and other documents
you have received alongside your G&D product, are trademarks or registered trade-
marks of the holder of rights.
© Guntermann & Drunck GmbH 2022. All rights reserved.
Version 1.20 – 29/09/2022
Guntermann & Drunck GmbH
Obere Leimbach 9
57074 Siegen
Germany
Phone +49 271 23872-0
Fax +49 271 23872-120
www.gdsys.com
Target and user modules (USB) · ii
FCC Statement
The devices named in this manual comply with Part 15 of the FCC Rules. Opera-
tion is subject to the following two conditions: (1) the devices may not cause harm-
ful interference, and (2) the devices must accept any interference received, including
interference that may cause undesired operation.
NOTE:
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a resi-
dential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful inter-
ference to radio communications. However, there is no guarantee that interfer-
ence will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be deter-mined by turning the equipment off and on, the user is encour-
aged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Table of contents
iii · Target and user modules (USB)
Table of contents
Safety guidelines ............................................................................................... 1
Chapter 1: Target modules
Target module »DVI-U-CPU« .......................................................................... 4
Target module »DVI-U-CPU-UC« .................................................................... 9
Target module »DVI-U-CPU-MC2« ............................................................... 14
Target module »DVI-U-CPU-MC2-UC« ........................................................ 20
Target module »DVI-U-CPU-Fiber« ............................................................... 27
Target module »DVI-U-CPU-Fiber-UC« ........................................................ 33
Target module »DL-DVI-U-CPU« .................................................................. 39
Target module »DL-DVI-U-CPU-UC« ........................................................... 44
Target module »DL-DVI-U-CPU-Fiber« ........................................................ 49
Target module »DL-DVI-U-CPU-Fiber-UC« .................................................. 55
Target module »DP-U-CPU« .......................................................................... 61
Target module »DP-U-CPU-UC« ................................................................... 66
Target module »DVI-I-U-CPU« ...................................................................... 71
Target module »DVI-I-U-CPU-UC« ............................................................... 76
Target module »DVI-I-U-CPU-Fiber« ............................................................ 81
Target module »DVI-I-U-CPU-Fiber-UC« ..................................................... 87
Target module »VGA-U-CPU-UC« ................................................................ 93
Table of contents
Target and user modules (USB) · iv
Chapter 2: User modules
User module »DVI-U-CON« .......................................................................... 98
User module »DVI-U-CON-MC2« ................................................................ 105
User module »DVI-U-CON-MC4« ................................................................ 113
User module »DVI-U-CON-2« ...................................................................... 122
User module »DVI-U-CON-Fiber« ................................................................. 129
User module »DVI-U-CON-Fiber-MC2« ...................................................... 136
User module »DVI-U-CON-Fiber-MC4« ...................................................... 145
User module »DVI-U-CON-2-Fiber« ............................................................. 154
User module »DP-U-CON« ........................................................................... 162
User module »DP-U-CON-2« ........................................................................ 169
Chapter 3: Generic HID
Enabling/disabling the user module’s Generic HID mode ............................ 176
Enabling/disabling the target module’s Generic HID mode .......................... 177
Chapter 4: Extender mode
Opening the on-screen display in extender mode ........................................... 179
Configuration ................................................................................................ 180
Safety guidelines
1 · Target and user modules (USB)
Safety guidelines
Please read through the following safety guidelines before putting the G&D product
into operation. The guidelines help to avoid damage to the product and prevent
potential injuries.
Keep these safety guidelines ready to hand for all persons who use this product.
Observe all warnings and operating information given at the device or in this operat-
ing manual.
Disconnect all power sources
Before installation, ensure that the device has been disconnected from all power
sources. Disconnect all power plugs and all power supplies of the device.
Débranchez toutes les sources d'alimentation
Avant l'installation, assurez-vous que l'appareil a été débranché de toutes les sources
d'alimentation. Débranchez toutes les fiches d'alimentation et toutes les alimenta-
tions électrique de l'appareil.
Trennen Sie alle Spannungsversorgungen
Stellen Sie vor der Installation sicher, dass das Gerät von allen Stromquellen getrennt
ist. Ziehen Sie alle Netzstecker und alle Spannungsversorgungen am Gerät ab.
Warning: electric shock
To avoid the risk of electric shock, you should not open the device or remove any cov-
ers. If service is required, please contact our technicians.
Ensure constant access to the devices’ mains plugs
When installing the devices, ensure that the devices’ mains plugs remain accessible
at all time.
Do not cover the ventilation openings
For device variants with ventilation openings, it must always be ensured that the
ventilation openings are not covered.
CAUTION:
Shock hazard!
ATTENTION:
Risque de choc électrique!
VORSICHT:
Risiko elektrischer Schläge!
!
Safety guidelines
Target and user modules (USB) · 2
Ensure correct installation position for devices with ventilation openings
For reasons of electric safety, devices with ventilation openings must only be
installed in an upright, horizontal position.
Do not insert any objects through the device’s openings
Objects should never be inserted through the device’s openings. Dangerous voltage
could be present. Conductive foreign bodies can cause a short circuit, which can
lead to fires, electric shocks or damage to your devices.
Avoid tripping hazards
Avoid tripping hazards while laying cables.
Use earthed voltage source
Only operate this device with an earthed voltage source.
Use exclusively the G&D power pack
Only operate this device with the power packs included in delivery or listed in this
operating manual.
Do not make any mechanical or electrical alternations to the device
Do not make any mechanical or electrical alternations to this device. Guntermann &
Drunck GmbH is not responsible for compliance with regulations in the case of a
modified device.
Do not remove device cover
The cover may only be removed by a G&D service technician. Unauthorised
removal voids the guarantee. Failure to observe this precautionary measure can
result in injuries and damage to the device.
Operate the device exclusively in the intended field of application
The devices are designed for indoor use. Avoid extreme cold, heat or humidity.
!
!
!
!
!
!
Safety guidelines
3 · Target and user modules (USB)
Special advices for dealing with laser technology
The Fiber devices of the target modules and user modules use components with laser
technology which comply with laser class 1 or better.
They meet the requirements according to EN 60825-1:2014 as well as U.S. CFR 1040.10
and 1040.11.
Mind the following advices when dealing with laser beams:
Avoid direct eye exposure to beam
Never stare directly into the beam when wearing optical instruments!
Always connect optical connections or cover them with protection caps
Always cover the optical connections of the Transmission socket and the cable plugs
with a connector or a protection cap.
Only use G&D certified transmission modules
It is not permitted to use fibre optic modules, which do not meet the requirements of
laser class 1 in accordance to EN 60825-1:2014. By using such modules, the compli-
ance with regulations and advices for the safe handling of laser technology cannot
be guaranteed.
The guarantee of complying with all relevant instructions can only be given by
applying original components. Therefore, the devices have to be operated with
G&D certified transmission modules only.
Class 1 Laser Product
EN 60825-1:2014
Complies with 21 CFR
1040.10 and 1040.11
Invisible laser beam, avoid
direct eye exposure with
optical instruments
Produit laser de classe 1
EN 60825-1:2014
Est conforme à 21 CFR
1040.10 et 1040.11
Laser invisible, évitez
l'exposition directe des yeux
avec des instruments optiques
LASER KLASSE 1
EN 60825-1:2014
Complies with 21 CFR
1040.10 and 1040.11
Unsichtbare Laserstrahlung,
nicht direkt mit optischen
Instrumenten betrachten
!
!
!
4 · Target and user modules (USB)
Target module »DVI-U-CPU«
With DVI-U-CPU target modules, you can connect a computer with DVI graphics out-
put to a digital matrix switch of the ControlCenter-Compact, ControlCenter-Digital or the
DVICenter series.
Users at the consoles of the matrix switch can access the target module and operate
the connected computer.
The data stream of the USB devices connected to the active user module (DVI-U-CON
and DP-U-CON series only) is transmitted to the computer with up to 16 Mbit/s.
Package contents
1 × DVI-U-CPU target module
1 × Video cable (DVI-D-DL)
1 × USB device cable
2 × Audio cable
1 × Power pack (12V/2A, only with variants incl. PowerPack)
1 × Power cable (only with variants incl. PowerPack)
1 × EasyStart flyer
1 × »Safety instructions« flyer
Required accessories
1 × Category 5e (or better) patch cable to connect the target module to the
matrix switch
ATarget modules
Target module »DVI-U-CPU«
5 · Target and user modules (USB)
Installation
Connecting target computers
Keyb.: Use the purple plug of an optional Twin-PS/2 cable to connect the purple PS/
2 socket (keyboard) to this port.
Mouse: Use the green plug of an optional Twin-PS/2 cable to connect the green PS/
2 socket (mouse) of the computer to this port.
USB K/M: Use the USB device cable to connect one of the computer’s USB ports to this
port.
DVI-D CPU: Use the video cable to connect the digital video output of the computer to
this port.
Line In: Use an audio cable to connect the Line-Out interface of the computer to this port.
Line Out: Use an audio cable to connect the Line-In interface of the computer to this port.
Connection to the matrix switch
Trans: Use a category 5e (or better) twisted pair cable to connect this interface to one
of the Dynamic Port (RJ45) provided at the matrix switch.
NOTE:
Both keyboard and mouse signals can be transmitted to the computer using
the PS/2 or the USB ports.
ADVICE:
You can also connect the target module directly to a compatible user module.
MouseKeyb. USB K/M DVI-D CPU
DVI-U-CPU
Line In Line Out Power In
Service
Power
Trans.
Target module »DVI-U-CPU«
Target and user modules (USB) · 6
Power supply
Power In: Plug the power cable of the power pack in this interface. Then connect the
power cable to the power pack and a power outlet.
Status displays
The LED on the back panel of the target module shows the status of the external
power pack:
The blinking Transmission LEDs signal the following operating statuses:
LED Status Meaning
Power Green The external power pack is connected and the required voltage (12 Volt)
is available.
The LED to identify the device in the web application is deactivated.
Blue The external power pack is connected and the required voltage (12 Volt)
is available.
The LED to identify the device in the web application is activated.
Off The external power pack is not (properly) connected.
LED Colour Status Meaning
Left Yellow Off No user module accesses the target module.
On A user module accesses the target module.
Blinking The incoming video signal was not detected.
Flashing No voltage at PS/2 interface or USB bus.
Right Green Off The target module is turned off.
On A user module accesses the target module.
Blinking The connection to the counterpart station could not be
established.
Flashing The connection to the counterpart station is established.
No user module is accessing.
Flickering Keyboard and mouse inputs are forwarded by the accessing
user module.
The flickering is defined by the user’s entries.
Target module »DVI-U-CPU«
7 · Target and user modules (USB)
Technical data
DVI-U-CPU
Interfaces to
computer: Video: 1 × DVI-D (Single Link)
Keyboard and mouse signals: 2 × PS/2 socket
1 × USB-B
Audio: 2 × 3,5 mm jack socket
Data transmission
to matrix switch Data transmission: 1 × RJ45 socket
Transmission length Max. 140 metres
Video Resolution @ 60 Hz: Max. 1920 × 1200 pixels
Further VESA and CTA standardized
resolutions within the video
bandwidth and horizontal/vertical
frequency possible.
Colour depth: 24 bits
Pixel rate: 25 MHz to 165 MHz
Vertical frequency: 50 Hz to 180 Hz
Horizontal frequency: 30 kHz to 130 kHz
Norms: DVI 1.0, E-DDC
DDC/CI: The device supports monitors with a
DDC/CI function. The DDC information
are transparently forwarded to the moni-
tor to support a maximum number of
monitors. However, the support cannot
be guaranteed for all monitor models.
Audio Transmission type: transparent, bidirectional
Resolution: 24 Bit
Sampling rate: 96 kHz
Bandwidth: 22 kHz
USB 2.0 Specification: USB 2.0
Transmission type: transparent
Transmission rate: Max. 16 Mbit/s
Power supply Type: Power pack(12 V/2 A)
Connection: 1 × Mini-DIN 4 socket
Current consumption: Max. 500 mA @ 12 VDC
Target module »DVI-U-CPU«
Target and user modules (USB) · 8
DVI-U-CPU
Casing Material: Anodised aluminium
Dimensions (W × H × D): 105 × 26 × 124 mm
Weight: Approx. 240 g
Operating
environment Temperature: +5 °C to +45 °C
Air humidity: 20 % to 80 %, non-condensing
Storage
environment Temperature: -20 °C to +60 °C
Air humidity: 15 % to 85 %, non-condensing
Conformity CE, EAC, FCC Class B, RoHS
Target module »DVI-U-CPU-UC«
9 · Target and user modules (USB)
Target module »DVI-U-CPU-UC«
With DVI-U-CPU-UC target modules, you can connect a computer with DVI graphics
output to two different digital matrix switches of the ControlCenter-Compact, Control-
Center-Digital or the DVICenter series.
Users at the consoles of the matrix switch can access the target module and operate
the connected computer.
The data stream of the USB devices connected to the active user module (DVI-U-CON
and DP-U-CON series only) is transmitted to the computer with up to 16 Mbit/s.
Package contents
1 × DVI-U-CPU-UC target module
1 × Video cable (DVI-D-DL)
1 × USB device cable
2 × Audio cable
1 × Power pack (12V/2A, only with variants incl. PowerPack)
1 × Power cable (only with variants incl. PowerPack)
1 × EasyStart flyer
1 × »Safety instructions« flyer
Required accessories
2 × Category 5e (or better) patch cables to connect the target module to
two different matrix switches
Target module »DVI-U-CPU-UC«
Target and user modules (USB) · 10
Installation
Connecting the target computer
Keyb.: Use the purple plug of an optional Twin-PS/2 cable to connect the purple PS/
2 socket (keyboard) to this port.
Mouse: Use the green plug of an optional Twin-PS/2 cable to connect the green PS/
2 socket (mouse) of the computer to this port.
USB K/M: Use the USB device cable to connect one of the computer’s USB ports to this
port.
DVI-D CPU: Use the video cable to connect the digital video output of the computer to
this port.
Line In: Use an audio cable to connect the computer’s Line-Out interface to this port.
Line Out: Use an audio cable to connect the computer’s Line-In interface to this port.
Connections to the matrix switches
NOTE:
Both keyboard and mouse signals can be transmitted to the computer using
the PS/2 or the USB ports.
IMPORTANT:
Only connect one Trans. interface of the target module per matrix
switch.
NOTE:
Use category 5e twisted pair cables (or better) to connect the devices.
MouseKeyb. USB K/M DVI-D CPU
DVI-U-CPU-UC
Line In Line Out Power In
Service
Power
Trans. 2Trans. 1
Target module »DVI-U-CPU-UC«
11 · Target and user modules (USB)
Trans. 1: Connect this interface to a Dynamic Port (RJ45) of a matrix switch.
Trans. 2: Connect this interface to a Dynamic Port (RJ45) of another matrix switch.
Power supply
Power In: Plug the power cable of the power pack in this interface. Then connect the
power cable to the power pack and a power outlet.
Status displays
The LED on the back panel of the target module shows the status of the external
power pack:
The blinking Transmission LEDs signal the following operating statuses:
NOTE:
You can also connect the target module directly to two compatible user
modules.
LED Status Meaning
Power Green The external power pack is connected and the required voltage (12 Volt)
is available.
The LED to identify the device in the web application is deactivated.
Blue The external power pack is connected and the required voltage (12 Volt)
is available.
The LED to identify the device in the web application is activated.
Off The external power pack is not (properly) connected.
LED Colour Status Meaning
Left Yellow Off No user module accesses the target module.
On A user module accesses the target module.
Blinking The incoming video signal was not detected.
Flashing No voltage at PS/2 interface or USB bus.
Right Green Off The target module is turned off.
On A user module accesses the target module.
Blinking The connection to the counterpart station could not be
established.
Flashing The connection to the counterpart station is established.
No user module is accessing.
Flickering Keyboard and mouse inputs are forwarded by the accessing
user module.
The flickering is defined by the user’s entries.
Target module »DVI-U-CPU-UC«
Target and user modules (USB) · 12
Technical data
DVI-U-CPU-UC
Interfaces to
computer: Video: 1 × DVI-D (Single Link)
Keyboard and mouse signals: 2 × PS/2 socket
1 × USB-B
Audio: 2 × 3.5 mm jack socket
Data transmission
to matrix switches Interface: 2 × RJ45 sockets
Transmission length Max. 140 metres
Video Resolution @ 60 Hz: Max. 1920 × 1200 pixels
Further VESA and CTA standardized
resolutions within the video
bandwidth and horizontal/vertical
frequency possible.
Colour depth: 24 bits
Pixel rate: 25 MHz to 165 MHz
Vertical frequency: 50 Hz to 180 Hz
Horizontal frequency: 30 kHz to 130 kHz
Norms: DVI 1.0, E-DDC
DDC/CI: The device supports monitors with a
DDC/CI function. The DDC information
are transparently forwarded to the moni-
tor to support a maximum number of
monitors. However, the support cannot
be guaranteed for all monitor models.
Audio Transmission type: transparent, bidirectional
Resolution: 24 bits
Sampling rate: 96 kHz
Bandwidth: 22 kHz
USB 2.0 Specification: USB 2.0
Transmission type: transparent
Transmission rate: Max. 16 Mbit/s
Power supply Type: Power pack (12 V/2 A)
Connection: 1 × Mini-DIN 4 socket
Current consumption: Max. 600 mA @ 12 VDC
Target module »DVI-U-CPU-UC«
13 · Target and user modules (USB)
DVI-U-CPU-UC
Casing Material: Anodised aluminium
Dimensions (W × H × D): 105 × 26 × 124 mm
Weight: Approx. 260 g
Operating
environment Temperature: +5 °C to +45 °C
Air humidity: 20 % to 80 %, non-condensing
Storage
environment Temperature: -20 °C to +60 °C
Air humidity: 15 % to 85 %, non-condensing
Conformity CE, EAC, FCC Class B, RoHS
Target module »DVI-U-CPU-MC2«
Target and user modules (USB) · 14
Target module »DVI-U-CPU-MC2«
With DVI-U-CPU-MC2 target modules, you can connect a computer with two DVI
graphics outputs (dual-head) to a digital matrix switch of the ControlCenter-Compact,
ControlCenter-Digital or the DVICenter series.
Users at the consoles of the matrix switch can access the target module and operate
the connected computer.
The data stream of the USB devices connected to the active user module (DVI-U-CON
and DP-U-CON series only) is transmitted to the computer with up to 16 Mbit/s.
Package contents
1 × Target module DVI-U-CPU-MC2
2 × Video cable (DVI-D-DL)
1 × USB device cable
2 × Audio cable
1 × Power pack (12V/2A, only with variants incl. PowerPack)
1 × Power cable (only with variants incl. PowerPack)
1 × EasyStart flyer
1 × »Safety instructions« flyer
Required accessories
2 × Category 5e (or better) twisted pair cables to connect the target module to the
matrix switch
IMPORTANT:
Only consoles configured for multi-monitor operation via channel
grouping can show the images of both of the computer’s video outputs on separate
monitors.
At consoles with one monitor only, the image of the computer’s second video out-
put is not displayed.
Target module »DVI-U-CPU-MC2«
15 · Target and user modules (USB)
Installation
Connecting the target computer
Keyb.: Use the purple plug of an optional Twin-PS/2 cable to connect the computer’s
PS/2 keyboard interface to this interface.
Mouse: Use the green plug of an optional Twin-PS/2 cable to connect the computer’s
PS/2 mouse interface to this interface.
USB K/M: Use the USB device cable to connect one of the computer’s USB interfaces
to this interface.
DVI-D CPU 1: Use one of the supplied video cables to connect the computer’s first dig-
ital video output to this interface.
DVI-D CPU 2: Use one of the supplied video cables to connect the computer’s second
digital video output to this interface.
Line In: Use one of the supplied audio cables to connect the computer’s Line Out
interface to this interface.
Line Out: Use one of the supplied audio cables to connect the computer’s Line In inter-
face to this interface.
NOTE:
Keyboard and mouse signals can be transmitted to the computer using either
the PS/2 interfaces or the USB interface.
DVI-D CPU 2
MouseKeyb. DVI-D CPU 1USB K/M
Trans.
Line In Line Out Power In
Service
Channel 2Channel 1
Power
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200

G&D DVI-CPU, DVI-CON, DL-DVI-CPU, DP-CPU, DP-CON, DVI-I-CPU, VGA-CPU, U2-R-CPU, U2-R-CON Installation and Operating Guide