Briggs & Stratton 1893 Owner's manual

Category
Power generators
Type
Owner's manual

This manual is also suitable for

TABLE OF CONTENTS
SafetyRules.................................... 2-4
Assembly...................................... 5-7
Operation .................................... 8- II
Maintenance.................................... 12
Storage........................................ 13
Troubleshooting ................................. 14
Warranty ...................................... 15
EQUIPMENT
DESCRIPTION
_Read this manual carefully and become
familiar with your generator. Know its
applications, its limitations and any hazards
involved.
The generators are anengine-driven, revolving field,
alternating current (AC) generator. It was designedto supply
electrical power for operating compatible electrical lighting,
appliances,tools and motor loads.Thegenerator's revolving
field is driven at about 3,600rpm by a single-cylinder engine.
CAUTION! DO NOT exceed the generator's
wattage/amperagecapacity.See"Don't Overload
Generator" on page I I.
Everyeffort hasbeen madeto ensurethat informationin this
manualisaccurateand current. However,we reserve the
right to change,alter or otherwise improvethe product and
this document at anytime without prior notice.
The EmissionControl Systemfor this generator iswarranted
for standardsset by the EnvironmentalProtection Agency.For
warranty informationrefer to the engineowner's manual.
In the State of California a spark arrester isrequired by lawI
(Section 4442 of the California PublicResources Code).
Other statesmay havesimilar laws.Federallawsapplyon
federal lands.If you equip the muffler with a spark arrester,
it must be maintained in effective working order.
SAFETY RULES
This is the safety alert symbol. It is used to
alert you to potential personal injury hazards.
Obey all safety messages that follow this
symbol to avoid possible injury or death.
The safety alert symbol (_.) isusedwith a signalword
(DANGER, CAUTION,WARNING), a pictorial and/or a
safety messageto alert you to hazards.DANGER indicates
a hazardwhich, ifnot avoided,will result in death or serious
injury.WARNING indicatesa hazardwhich,if not avoided,
couldresult in death or serious injury.CAUTION
indicatesa hazardwhich, ifnot avoided,might result in
minor or moderate injury.CAUTION, when used
without the alert symbol, indicatesa situation that could
result in equipment damage.Follow safety messagesto
avoid or reduce the risk of injuryor death.
WARNING
The engine e_duct contains
chemicals known to the State of California to cause
cancer, b rth defects, or other reproduct ve harm.
Hazard Symbols and Meanings
Electrocution Electrical Shock Electrical Shock
Toxic Fumes
'0
Explosive Pressure
Explosion Fire
Chemical Burn Hot Surface
DANGER
Operate generator ONLY outdoors.
Keep at least 2 feet of clearance on all sides of generator for
adequateventilation.
DO NOT operate generator insideanybuildingor enclosure,
includingthe generator compartment ofa recreationalvehicle(RV).
DANGER
When usinggenerator for backup power, notify utility
company.Use approved transfer equipment to isolate
generator from electric utility.
Use a ground circuit fault interrupter (GFCi) in any damp or
highly conductive area, suchas metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT usegenerator with electrical cords which are worn
frayed, bare or otherwise damaged.
DO NOT operate generator inthe rain.
DO NOT handle generator or electrical cords while standing
in water, while barefoot, or while handsor feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
DANGER
DO NOT allow anyopen flame,spark,heat, or lit cigarette
during andfor several minutes after charginga battery.
Wear protective goggles,rubber apron, and rubber gloves.
, WARNING
WHEN ADDING FUEL
Turngenerator OFF and let it cool at [east2 minutes before
removing gascap.Loosen capslowly to relieve pressure in tanlc
Fill fuel tank outdoors.
DO NOT overfill tank.Allow spacefor fuel expansion.
Keepfuel awayfrom sparks,open flames,pilot lights,heat, and
other ignitionsources.
DO NOT light a cigarette or smoke.
fVHEN OPERATING EQUIPMENT
DO NOT tip engine or equipment at anglewhich causesfuel
to spill.
Thisgenerator is not for use in mobile equipment or marine
applications.
'HEN TRANSPORTING OR REPAIRING EQUIPMENT
Transportlrepair with fuel tank EMPTY or with fuel shutoff
valve OFE
Disconnect spark plug wire.
VHEN STORING FUEL OR EQUIPMENT WITH FUEL
IN TANK
Store awayfrom furnaces, stoves,water heaters,clothes
dryers or other appliances that have pilot light or other
ignition source becausethey can ignite fuel vapors.
, WARNING
Thisgenerator does not meet U. S.Coast Guard Regulation
33CFR-183 andshould not be usedon marine applications.
Failureto use the appropriate U. S.Coast Guard approved
generator could result in bodily injury and/or property
damage.
;ENERATOR
WARNING
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
, WARNING
DO NOT touch hot surfaces.
Allow equipment to cool before touching.
CAUTION
DO NOT tamper with governed speed.Generator supplies
correct rated frequency and voltage when running at governed
speed.
DO NOT modify generator in any way.
CAUTION
See"Don't Overload Generator" on page I I.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF anddisconnect from generator
before stopping generator.
CAUTION
Use generator onlyfor intended uses.
tfyou havequestions about intended use,ask dealer or call
1-800-743-4115.
Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
DO NOT insertany objects through cooling slots.
If connected devices overheat, turn them offand disconnect
them from generatoc
Shutoff generator if.'
-electrical output is lost;
-equipment sparks,smokes,or emits flames;
-unit vibrates excessively.
ASSEMBLY
Your generator requires some assemblyand isready for
useafter it hasbeen properly serviced with the
recommended oil and fuel.
If you haveanyproblems with the assemblyof your
generator,pleasecallthe generator helplineat
1-800-743-4115. If callingfor assistance,pleasehavethe
model, revision,andserial number from the datatag available.
INSTALL WHEEL KIT
NOTE: If your unit issupplied with a 10"wheel kit use
the following instructions.If your unit issupplied with an
8" wheel kit usethe instructionson page6.
NOTE:While the wheel kit is designedto greatly improve
the portability of your generator, it isnot intendedfor
over-the-road use.
You will need a socket wrench with I/2" or 13mm sockets
and a needle-nose pliers to install this kit.
Install the 10" Wheel Kit as Follows
I. Placethe bottom of the generator cradle on a fiat,
evensurface.Temporarily place unit on blocks to ease
assembly.
2. Slide axle through both axle mounting brackets on
cradle frame, asshown in Figure I.
3. Slide a wheel over the axle.
NOTE: Be sure to install both wheels with the air
pressure valve on the outboard side.
4. Placethe e-ring onto the groove inthe axle.You may
add the fiat washer if desired.
NOTE: Use retaining pins insteadof e-clip,if applicable.
5. Placeone end of the needle nose pliers on the bottom
of the axle and the other end of the pliers on top of
the e-ring.Seatthe e-ring by pressing the pliers closed.
6. Repeat step 3 through 5 to secure second wheel.
7. Removethe temporary blocks.
8. Attach the vibration mounts to the support leg with
30mm capscrewsand lock nuts.
9. To aid support leg assembly,rest generator on cradle,
engine end down. Removethe existing hardware from
the left unit vibration mount with 13ramwrench. Use
the samehardware to attach the support leg.
10. Attach the other side of the support leg with a 20mm
cap screw and lock nut Restgenerator on wheels and
support leg.
FlatWasher
support leg to unit
Axle
Cap Screw
1_ Hex Nut
Cap Screw
E-Ring
II. Ifequipped,centerthehandlebracketongenerator
frameatsupportlegendofcradle,asshown.
12.AttachhandlebracketwithtwoM8x45mmcap
screwsand two lockinghexnuts.
13.Checkthatallfastenersaretightandthetiresareinflated
tothevaluemarkedon thetireorwithin15and40psi.
Install the 8"Wheel Kit as Follows
I. Placebottom of generator cradle on afiat surface.
2. Placeaxle stud through wheel retainer on cradle frame,
asshown in Figure2.
3. Use 15/16" wrench to secure the axle stud to frame
with 5/8-18 jam nut.
4. Install the other axle stud in the same manner.
NOTE: Be sure to install wheel with raised hub inboard.
5. Tip unit and installthe wheel. Placefiat washer over
axle stud.
6. Retain wheel on axle stud with retaining pin. Install
other wheel on remaining axle shaft the same way.
7. Attach the vibration mount to the mounting leg with a
capscrew and lock nut.
8. Remove two front nuts from vibration mount on unit
with 13ram wrench. Use these nuts to retain the
mounting leg.
9. Center the lifting handle on generator end of cradle.
Attach handle using two 13mm wrenches with two
capscrews and two hex nuts.
Capscrew
Handle
Grip
Axle Stud
Nut "
Vibration
Nut
Jam Nut
Washer
ExistingFasteners
to SecureLeg RetainingPin
ELECTRIC START
Your unit may be equipped with electric start capability but
can be started manually.Ifyou choose not to use the
electric start feature,you do not need to install the battery.
If your unit does not haveelectric start, ignore this section.
Check Battery / Attach Negative
Battery Wire
The sealedbattery on the generator is fully charged and
pre-lnstalled except for the negative (black) battery cable.
To install:
I. Cut off tie wrap securing loose end of negative (black)
cable.
2. Remove nut and washer on negative battery terminal.
3. Slide negative battery cable over screw on negative
terminal (Figure 3).
Negative
battery
cable
Screw \
Positive battery cable
4. Reattach washer and nut and tighten.
5. Verify that connections to battery and generator are
tight and secure.
BEFORE STARTING THE
ENGINE
Add Engine Oil and Fuel
• Place generator on a level surface.
CAUTION
• Refer to engine manual for oil and fuel fill information.
• Damage to equipment resulting from failure to follow this
instruction will void warranty.
• Refer to engine owner's manual and follow oil and fuel
recommendations and instructions.
NOTE: Check oil often during engine break-in. Refer to
engine owner's manual for recommendations.
NOTE: The generator assembly rotates on a prelubricated
and sealed ball bearing that requires no additional
lubrication for the life of the bearing.
USING THE GENERATOR
System Ground
The generator hasa system ground that connects the
generator frame components to the ground terminals on
the AC output receptacles.The system ground is connected
to theAC neutral wire (the neutral is bonded to the
generator frame).
_'.-ma.U_i
Special Requirements
There may be Federalor State Occupational Safetyand
Health Administration (OSHA) regulations,localcodes,or
ordinances that applyto the intendeduse of the generator.
Pleaseconsult a qualified electrician, electrical inspector,or
the localagencyhavingjurisdiction.
• In some areas,generators are required to be registered
with localutility companies.
• If the generator isused at a construction site, there may
be additional regulations which must be observed.
Connecting to a Building's Electrical
System
Connections for standby power to a buitding'selectrical
system must be made by a qualified electrician.The
connection must isolatethe generator power from utility
power, and must comply with all applicable lawsand
electrical codes.
DANGER
When usinggenerator for backup power, notify utility
company.Use approved transfer equipment to isolate
generator from electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, suchas metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT usegenerator with electrical cords which are worn
frayed, bare or otherwise damaged.
DO NOT operate generator inthe rain.
DO NOT handle generator or electrical cords while standing
in water, while barefoot, or while handsor feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
BATTERY CHARGER
If equipped, usebattery float charger jackto keep the
starting battery charged and ready for use.Battery charging
should be done in a dry location,such as insidea garage.
I. Plugcharger into unit's"Battery Float Charger" jack,
which islocatedon the starter switch (Figure 4). Plug
battery charger intoa 120Volt AC wall receptacle.
2. Unplug charger from unitand wall outlet when
generator isbeing started and whileit isin operation.
3. Keep this charger plugged in when generator isnot in
use to prolong battery life.Thecharger hasa built in
float equalizer and will not overcharge the battery,
even when plugged in for an extended period of time.
IMPORTANT: See+'Battery Maintenance" on page 12for
additional information.
OPERATING THE
G EN ERATO R
CAUTION
See"Don't Overload Generator" on page I I.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF anddisconnect from generator
before stopping generator.
IMPORTANT: Always unplugthe battery float charger
before starting the generator.
Starting the Engine
Disconnect all electrical loadsfrom the generator. Use the
following start instructions:
I. Make sure unit ison a levelsurface.
IMPORTANT: Failureto start and operate unit on a level
surface will cause the unit not to start or shut clown during
operation.
2A. For models with the fuel valve built into the engine,
turn the fuel valve to the "On" position (Figure5).
FuelValve is
On position
f
2B. For models with an overhead fuel tank, turn the fuel
valve to the "On" position (Figure6).The fuel valve
handle should be vertical (pointing toward the ground)
for fuel to flow.
FuelValve is shown
in the On position
3. Start engine according to instructions given in the
engine owner's manual.
NOTE: If engine starts after 3 pulls but fails to run,or if
unit shuts down during operation, make sure unit is on a
level surface and check for proper oil level in crankcase.
This unit may be equipped with a low oil protection device.
Seeengine manual.
Connecting Electrical Loads
• Let engine stabilize and warm up for a few minutes after
starting.
• Plug in and turn on the desired 120 and/or 240 VottAC,
singlephase,60 Hz electrical loads.
• DO NOT connect 240Vott loads to the 120Volt duplex
receptacles.
• DO NOT connect 3-phase loadsto the generator.
• DO NOT connect 50 Hz loads to the generator.
• DO NOT OVERLOADTHE GENERATOR. See
"Don't Overload the Generator" on page I I.
Stopping the Engine
I. Unplugall electrical loads from generator panel
receptacles.Never start or stop engine with electrical
devicesplugged in and turned ON.
2. Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and generator.
3. Turn engine off according to instructions given in the
engine owner's manual.
4. Move fuel valve to "Off" position.
RECEPTACLES
The generator wilt be equippedwith one or more of the
following receptacles:
CAUTION
NEVERattempt to power a device requiring more
amperagethan generator or receptacle can supply.
DO NOT overload the generator. See"Don't Overload
Generator".
120/240 Volt AC, 30 Amp, Locking
Receptacle
Use a NEMA LI4-30 plug with this receptacle.Connect a
4-wire cord set rated for 250Volt AC loads at 30 Amps (or
greater) (Figure 7).You can usethe same4-wire cord if you
plan to run a 120Volt load.
r (Neutral)
Y (Hot) | X (Hot)
I
NEMA L14-30 /_ Ground(Green)
This receptacle powers 120/240Volt AC, 60 Hz,single
phaseloads requiring up to 6,000watts of power (6.0 kW)
at 30 Amps for 120Volts or 240Volts.The outlet is
protected by a push-to-reset circuit breaker.
120 Volt AC, 30 Amp Locking
Receptacle
Use a NEMA L5-30 plug with this receptacle.Connect a
3-wire cord set rated for 125Volts AC at 30 Amps to the
plug (Figure 8).
3-WireCord Set
NEMA L5-30
_ Neutral
_d (Green)
i
Usethis receptacle to operate 120VoltAC, 60 Hz, single
phaseloads requiring up to 3,600 watts (3.6 kW) of power
at 30Amps.The outlet is protected by a push-to-reset
circuit breaker.
120 Volt AC, 20 Amp, Duplex
Receptacles
Each duplex receptacle (Figure 9) is protected against
overload by a push-to-reset circuit breaker.
Use each receptacleto operate 120Volt AC, single-phase,
60 Hz electrical loadsrequiring up to 2,400 watts (2.4 kW)
at 20Amps of current. Use cord sets that are rated for
125Volt AC loads at 20Amps (or greater).
COLD WEATH ER
OPERATION
Under certain weather conditions (temperatures below
40°F [4°C] and a high dew point), your generator may
experience icingof the carburetor and/or the crankcase
breather system.
Build a structure that wilt enclose three sides and the top
of the generator:
I. Make sure entire muffler-side of generator is exposed.
Note that your generator may appear different from
that shown in Figure 10.
2. Ensure a minimum of two feet clearance between open
side of box and nearest object
3. Face exposed end away from wind and elements.
4. Enclosure should hold enough heat created by the
generator to prevent problems.
DANGER
Operate generator ONLY outdoors.
Keep at least 2 feet of clearance on all sides of generator for
adequateventilation.
DO NOToperategeneratorinsideanybuilding or enclosure,
includingthegenerator compartment ofa recreationalvehicle(RV).
Removegeneratorfrom shelterwhentemperatureisabove
40oF[4oc].
DON'T OVERLOAD
G EN ERATO R
Capacity
You must make sure your generator cansupply enough
rated (running) and surge (starting) watts for the itemsyou
will power at the sametime. Follow these simple steps:
I. Select the itemsyou wilt power at the sametime.
2. Total the rated (running) watts of these items.Thisis
the amount of power your generator must produce to
keep your itemsrunning.See Figure I I.
3. Estimate how many surge (starting) watts you wilt
need.Surgewattage isthe short burst of power
needed to start electric motor-driven tools or
appliancessuch asa circular saw or refrigerator.
Becausenot all motors start at the sametime, total
surgewatts canbe estimated by adding only the
item(s)with the highest additional surge watts to the
total rated watts from step 2.
Example:
Tool or Appliance
Window Air
Conditioner
Refrigerator
Deep Freezer
Television
Light (75 Watts)
Rated(Running)
Watts
1200
800
500
500
75
3075 Total
RunningWatts
Total Rated (Running)Watts = 3075
Highest Additional SurgeWatts = 1800
Total Generator Output Required = 4875
Additional Surge
(Starting)Watts
1800
1600
500
1800 Highest
Surge Watts
Power Management
To prolong the life of your generator andattached devices,
it is important to take care when adding electrical loadsto
your generator.There should be nothing connected to the
generator outlets before starting it's engine.The correct
and safe way to managegenerator power isto sequentially
add loadsasfollows:
I. With nothingconnected to the generator, start the
engine asdescribed in this manual.
2. Plug in and turn on the first load,preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly.
4. Plugin and turn on the next load.
5. Again,permit the generator to stabilize.
6. Repeat steps4 and 5 for eachadditional load.
NEVERadd more loadsthan the generator capacity.Take
special care to consider surge loads in generator capacity,
as described above.
Tool or Appliance
Rated*
(Running)
Watts
Additional
Surge
(Starting)
Watts
Essentials
Light Bulb - 75 watt 75
Deep Freezer S00 S00
Sump Pump 800 1200
Refrigerator/Freezer - 18Cu. Ft. 800 1600
Water Well Pump - I/3 HP 1000 2000
Heating/Cooling
Window AC - I0,000 BTU 1200 1800
Window Fan 300 600
FurnaceFanBlower - 1/2 HP 800 1300
Kitchen
Microwave Oven - 1000Watt 1000
Coffee Maker 1500
Electric Stove - SingleElement 1500
Hot Plate 2500
Family Room
DVD/CD Player 100
VCR 100
Stereo Receiver 450
Color Television - 27" S00
Personal Computer w/I 7" monitor 800
Other
SecuritySystem 180
AM/FM Clock Radio 300
Garage Door Opener - 1/2 HP 480 520
Electric Water Heater - 40 Gallon 4000
DIY/Job Site
Quartz Halogen Work Light 1000
Airless Sprayer - I/3 HP 600 1200
Reciprocating Saw 960 960
Electric Drill - 1/2 HP 1000 1000
Circular Saw- 7 I/4" 1500 1500
Miter Saw- 10" 1800 1800
Table Planer - 6" 1800 1800
Table Saw/RadialArm Saw- 10" 2000 2000
Air Compressor - I-I/2 HP 2500 2500
*Wattages listed are approximate only. Check toot or
appliance for actual wattage.
I|1
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator isresponsible for making sure that
all periodic maintenancetasks are completed on a timely
basis;that all discrepanciesare corrected; and that the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.
Engine Maintenance
Seeengine owner's manualfor instructions.
CAUTION
Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
Thoroughly wash exposed areaswith soap and water.
KEEPOUT OF REACH OF CHILDREN. DON'T
POLLUTE.CONSERVE RESOURCES.RETURN
USED OIL TO COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a dean dry
environment where it wl{{ not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
SlOtS in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: DO NOT use agarden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
WARNING
Disconnectthe spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
Battery Maintenance
Other than float charging,described elsewhere, no
maintenance isrequired for the starting battery. Keep the
battery and terminals clean and dry.
IMPORTANT: Battery chargingshould be performed in a
dry location, such asinsidea garage.
Generator Cleaning
• Use a damp cloth to wipe exterior surfaces clean.
CAUTION
DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
DO NOT insert any objects through cooling slots.
• Use a soft bristle brush to loosen caked on dirt or oil.
• Use a vacuum cleaner to pick up loose dirt and debris.
• Use low pressure air (not to exceed 25 psi) to blow
away dirt. Inspect cooling air slots and opening on
generator.These openingsmust be kept cleanand
unobstructed.
STO RAG E
The generator should be started at least once every seven
daysand allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than
30 days,use the following guidelines to prepare it for
storage.
Generator Storage
• Clean the generator as outlined in"Generator Cleaning".
• Check that cooling air slots and openings on generator
are open and unobstructed.
WARNING
DO NOT place a storage cover over a hot generator.
Let equipment cool for a sufficient time before placing the
cover on the equipment.
Engine Storage
See engine owner's manualfor instructions.
Other Storage Tips
• To prevent gum from forming in fuel system or on
essential carburetor parts, add fuel stabilizer into fuel
tank and fill with fresh fuel. Run the unit for several
minutes to circulate the additive through the carburetor.
The unit and fuel can then be stored for up to
24 months. Fuel stabilizer can be purchased locally.
• Do Not store fuel from one season to another unless it
has been treated as described above.
• Replace fuel container if it starts to rust. Rust and/or dirt
in fuel can cause problems if it's used with this unit.
• Store unit in a clean and dry area.
TROUBLESHOOTING
Problem
No AC output is available, but
generator is running.
Cause
I. One of the circuit breakers is
open.
2. Fault in generator.
3. Poor connection or defective
cord set.
4. Connected device is bad.
Correction
I. Reset circuitbreaker.
2. Contact Authorized service
facility.
3. Check and repair.
4. Connect another device that is in
good condition.
I. Short circuit in a connected load. I. Disconnect shorted electrical
Generator runs good at no-load load.
but "bogs" down" when loads are 2. Generator is overloaded. 2. See "Don't Overload Generator".
connected. 3. Shorted generator circuit. 3. Contact Authorized service
facility.
I. Failed battery. I. Replace battery.
Generator will not start; or starts 2. Low oil level. 2. Fill crankcase to proper level or
and runs rough, place generator on level surface.
I. Out of gasoline. I. Fill fuel tank.
Generator shuts down during
operation. 2. Low oil level. 2. Fill crankcase to proper level or
place generator on level surface.
Generator lacks power. Load is too high. See "Don't Overload Generator".
Effective January 1, 2003 replaces all undated Warranties and all Warranties dated before January 1, 2003
LIMITED WARRANTY
Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s), of the equipment that is defective in material
or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne by
purchaser. This warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest
Authorized Service Dealer in our dealer Iocator map at www.briggspowerproducts.com.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW ANY
AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED
TO THE EXTENT EXCLUSION ]S PERMITTED BY LAW. Some states or countries do not allow limitations on how long an implied warranty
lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation
and exclusion may not apply to you. This warranty gives you specific legal dghts and you may also have other rights which vary from state
to state or country to country.
Consumer Use
CommerciaJ Use
The engine and starting batteries are warranted soIely by the manufacturers of those products.
2 years for alI consumer products in the European Union Parts onIy on 2nd year for consumer use of Portable Generator and
Home Generator System - Less than 10 KW, outside of European Union
The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time
stated in the table above. "Consumer use" means personal residential household use by a retail consumer. "Commercial use" means all other
uses, including use for commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter
be considered as commercial use for purposes of this warranty. Equipment used for Prime Power in place of utility are not applicable to
this warranty. Electric Powered Pressure Washers used for commercial purposes are not warranted.
NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR
PROOF OF PURCHASE RECEIPT. iF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY
SERVICE IS REQUESTED, THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY
PERIOD.
We welcome warranty repair and apologize to you for being inconvenienced. Any Authodzed Service Dealer may perform warranty repairs. Most
warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not
apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation.
Similarly, the warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered
or modified. During the warranty pedod, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to
be defective under normal use and service. This warranty will not cover the following repairs and equipment:
Normal Wear: Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not
cover repair when normal use has exhausted the life of a part or the equipment.
Installation and Maintenance: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized
installation or alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as,
in our judgment, to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as adjustments,
fuel system cleaning and obstruction (due to chemical, dirt, carbon, lime, etc.).
Other Exclusions: This warranty excludes wear items such as quick couplers, oil gauges, belts, o-rings, filters, pump packing, etc., pumps that
have been run without water supplied or damage or malfunctions resulting from accidents, abuse, modifications, alterations, or improper servicing
or freezing or chemical deterioration. Accessory parts such as guns, hoses, wands and nozzles are excluded from the product warranty. Also
excluded is used, reconditioned, and demonstration equipment; equipment used for prime power in place of utility power and equipment used in
life support applications.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON, WI, USA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Briggs & Stratton 1893 Owner's manual

Category
Power generators
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI