TOTALINE HUMCCLFP1218 Owner's manual

Category
Humidifiers
Type
Owner's manual

This manual is also suitable for

Part Number P110-LFP1025A, P110-WTR2019A,
P110-LBP2018A, P110-SFP1016A,
P110-SBP2017A
GENERAL
Congratulations on your excellent choice in this addition
to your home comfort system.
Your humidifier represents both the latest in engineering
development and the culmination of many years of experi-
ence from one of the most reputable manufacturers of com-
fort systems.
Your new unit is among the most energy-efficient and
reliable home humidifiers available today. To assure its
dependability, spend a few minutes now with this booklet.
Learn about the operation of your humidifier and the small
amount of maintenance it takes to keep it operating at peak
efficiency.
During the heating season, your home can become un-
comfortably dry. This is because cold winter air holds very
little moisture. When outdoor air is warmed to average room
temperature, its relative humidity falls to even lower levels.
Proper humidity control can alleviate problems caused by
excessive dryness. The additional moisture supplied by your
humidifier may enable you to reduce the temperature setting
on your thermostat without any loss of indoor comfort.
Your humidifier adds water to the air inside your home.
Although the rate of humidification is variable, it may ex-
ceed one-half gallon of water per hour. The typical process
of humidification begins when water flows through the hu-
midifier valve and soaks the large evaporator pad. Hot, dry
air from the furnace passes through the pad and absorbs the
water. Then, this moisture-laden air is distributed through-
out the house via the ductwork. See Fig. 1. Typical humidi-
fier installations are shown in Fig. 2.
OPERATING YOUR HUMIDIFIER
Your new humidifier is designed to operate as part of your
home heating system. For performance at maximum effi-
ciency, follow these recommendations:
The humidifier is controlled by a humidistat. Adjust the
humidistat setting according to the outside temperature. Re-
fer to Table 1 as a general guide. If after several days, the
air in your home is too moist, lower the humidistat setting.
Condensation on single-pane windows indicates exces-
sive moisture. If the air is too dry, increase the setting.
Continuous blower operation provides for constant hu-
midification. Continuous blower operation also minimizes
temperature differences throughout the home. Further-
more, a system equipped with an electronic air cleaner of-
fers the added benefit of full-time air filtration.
Supply- and return-air grilles should not be blocked by drapes,
furniture, or other objects. Restricted airflow reduces the
efficiency of the humidifier, as well as that of the whole
comfort system.
The humidifier unit must be properly maintained on a regu-
lar basis.
Table 1 Humidistat Settings
OUTSIDE
TEMPERATURE
(°F)
RECOMMENDED
HUMIDISTAT SETTING
(% RELATIVE HUMIDITY)
−20 15
−10 20 (LOW)
−0 25
10 30
20 35
30 40 (MED)
OWNER’S
MANUAL
Residential
Humidifier
DRY
AIR
EVAPORATOR
PAD
HUMIDIFIED
AIR
DRAIN
Fig. 1 Humidifier Operation
Fig.2—Typical Humidifier Installations
Manufacturer reserves the right to discontinue, or
change at any time, specifications or designs
without notice and without incurring obligations.
REPLACEMENT COMPONENTS DIVISION LITERATURE NUMBER HUM-50SO
R CARRIER CORPORATION 1/99 REPLACES 2-05930
PRINTED IN U.S.A.
Start-Up Procedures
1. Open the saddle valve on the water supply line. (See
Fig. 3.) Set humidistat to the desired relative humidity.
(See Fig. 4 and Table 1.)
2. Turn the furnace on and adjust the thermostat to a high
temperature setting. Be sure that the furnace blower is
operating.
3. Check to see if water is flowing into the humidifier.
On P110-L8P2018A or P110-LFP1025A humidifiers,
loosen the thumbscrew that holds the distributor cover
to the top of the cabinet. Lift up the distributor cover
slightly to make certain that water is flowing from the
solenoid valve into the distributor pan. Do not lift the
cover off the cabinet more than 1 in. when water is flow-
ing. (See Fig. 5 or 6.)
On a P110-SBP2017Ahumidifier, gently pull the latch
that secures the access door. Remove the door. Check
to see if water is flowing from the solenoid valve into
the evaporator pad. (See Fig. 7.)
On a P110-SFP1016A humidifier, open the side door
or the front cover. If the front cover is opened, hold the
pad assembly in place. Check to see if water is flowing
from the solenoid valve into the distributor pan. (See
Fig. 8.)
On a P110-WTR2019Ahumidifier, look through the win-
dow on front of the unit to see that the evaporator pad
is rotating and water is flowing. (See Fig. 9.)
The P110-WTR2019Ahumidifier is controlled by a float
valve. Turning off the furnace will not affect the water
flow until float level is achieved.
4. Turn off the furnace. When the blower stops, look into
the humidifier to make sure the water is not flowing into
the unit.
5. Replace the cover assembly and fasten securely.
6. Now, turn the furnace on and set the thermostat for de-
sired room temperature.
Fig. 3 Saddle Valve
HUMIDISTAT
Fig. 4 Humidistat
DISTRIBUTOR COVER
SOLENOID VALVE
DISTRIBUTOR PAN
EVAPORATOR PAD
CABINET
BOTTOM ACCESS
PANEL
Fig. 5 Humidifier Details P110-LBP2018A
SOLENOID VALVE
DISTRIBUTOR COVER
DISTRIBUTOR PAN
EVAPORATOR PAD
CABINET
BOTTOM ACCESS PANEL
Fig. 6 Humidifier Details P110-LFP1025A
CABINET
RECTIFIER
DRAIN
INLET
DISTRIBUTOR
PAN
EVAPORATOR
PAD
DUCT
HOUSING
SIDE
ACCESS
DOOR
SOLENOID
VALVE
Fig. 7 Humidifier Details P110-SBP2017A
2
Shutdown Procedures To shut down your humidi-
fier, close the saddle valve on the water line. Then turn off
the humidistat. When set to the OFF position, the humidistat
shuts off the electrical power to the solenoid valve on the
humidifier.
NOTE: If your home comfort system includes cooling, be
sure the water supply to your humidifier is turned off during
the cooling season. Close the damper located in the bypass
duct if one is installed. If your humidifier is a part no. P110-
WTR2019A, drain and clean the water pan as described in
cleaning procedures.
PERFORMING ROUTINE MAINTENANCE
With the proper maintenance and care, your humidifier will
operate economically and dependably. Maintenance can be
accomplished easily by referring to the following directions.
However, before performing any maintenance, consider these
important safety precautions:
Disconnect all electrical power to the humidifier and fur-
nace before performing any service or maintenance to
avoid personal injury or death.
NOTE: There may be more than one electrical disconnect
switch.
Although special care has been taken to minimize sharp
edges in the construction of your humidifier, be ex-
tremely careful when handling parts or reaching into the
unit to avoid personal injury.
Your humidifier has been designed for easy disassembly
to simplify cleaning and servicing. Your unit must be kept
clean to maintain its efficiency.
Regular inspection allows you to determine the cleaning
schedule best suited to your humidifiers operating condi-
tions. The frequency for required maintenance will depend
most upon the available water supply. In areas where hard
water and high mineral content are prevalent, more frequent
cleaning and servicing may be required.
At minimum, the humidifier will need to be cleaned at the
beginning of every heating season.
Cleaning Procedures
P110-LBP2018A, P110-SBP2017A, P110-LFP1025A, AND
P110-SFP1016A HUMIDIFIERS
1. Turn off all electrical power to the humidifier and furnace
or fan coil.
2. Turn off the humidifiers water supply. (See Fig. 3.)
3. Disassemble the humidifier.
To disassemble a P110-SBP2017A humidifier, gently
pull the latch that secures the access panel. Remove the
door and slide the evaporator pad assembly out of the
unit. (See Fig. 7.)
To disassemble either a P110-LBP2018A or P110-
LFP1025Ahumidifier, first remove the water supply con-
nection to the solenoid valve. Next, remove the screw
that holds the distributor cover to the cabinet, and lift
off the cover. Disconnect the drain line from the sump
and loosen the thumbscrews(s) holding the sump to the
cabinet. Remove the sump. Remove evaporator pad as-
sembly. (See Fig. 5 or 6.)
To disassemble a P110-SFP1016A humidifier, the pad
assembly can be removed from the side access door or
the front cover. When removing the side door, lift the
pad assembly up by holding the tabs and slide the as-
sembly out. When removing the front cover, discon-
nect the quick connects to the solenoid valve, unscrew
the 4 screws to the front cover, snap loose the top and
bottom catches, and lay the front cover aside. Once the
front cover is off, lift the pad assembly up and twist it
out. The pad assembly consists of 4 parts; the distribu-
tor pan, frame, sump, and the evaporator pad. Pull the
distributor pan apart from the frame and the evaporator
pad can be removed. Do not force the evaporator pad
in or out without removing the distributor pan as this
will distort the pad. See Fig. 8.
4. Clean the humidifiers external components.
If your humidifier is a P110-SBP2017Ahumidifier, wash
the access door and outlet drain portion of the cabinet.
Make sure the drain is open.
If your humidifier is a P110-LBP2018A, P110-SFP-
1016A, or P110-LFP1025A unit, wash the distributor
cover, sump cover, and cabinet. Be sure the inlet ports
are open and clean. Then, clean the sump with a so-
lution of detergent and water.
5. Clean the internal components of your humidifier. Wash
the distributor pan with a mild detergent and warm water.
Be sure holes and slots in the pan are clean and unob-
structed. Wash the evaporator pad assembly in a deter-
gent solution. If there are scale deposits on the pad, soak
CABINET
FRONT COVER
SCREWS (4)
SIDE ACCESS DOOR
PAD ASSEMBLY
SOLENOID VALVE
DISTRIBUTOR PAN
(HIDDEN)
Fig. 8 Humidifier Details P110-SFP1016A
BEARING RETAINER
CABINET
PAD
PAN
Fig. 9 Humidifier Details P110-WTR2019A
3
it in ordinary household vinegar. If the pad is covered by
a heavy deposit of scale, or if the local water supply has
high sulfate or calcium content, replace the pad with a
new one. Contact your dealer for replacement part.
6. Reassemble your humidifier.
7. Turn on the electrical power and water supplies. Refer to
the start-up procedures.
P110-WTR2019A HUMIDIFIERS
1. Turn off all electrical power to the humidifier and furnace
or fan coil.
2. Turn off the humidifiers water supply. (See Fig. 3.)
3. Drain water from the unit. Place a pail underneath the
drain plug located on the bottom of the humidifier cabi-
net. Lift the tab on the drain plug and remove the plug.
Allow all water to drain from the unit. (See Fig. 10.)
4. Remove the front door from the humidifier. Rotate the
latches one-half turn, then pull the door forward.
5. Remove and inspect the evaporator pad assembly. Lift
the bearing from its retainer. (See Fig. 9.) Pull the as-
sembly away from the motor to disengage the assembly
shaft from the motor coupling. Remove assembly through
the access opening.
Inspect the evaporator pad. If the pad is heavily loaded
with scale, or if the local water has a high sulfate content,
replace the pad. Contact your dealer for replacement part.
NOTE: For best performance, the evaporator pad should
be replaced before each heating season.
6. Inspect the float assembly. Remove the float arm from
the valve body by sliding out the pin and lifting off the
float arm. (See Fig. 11.) Inspect the rubber valve seat lo-
cated inside the float arm. If the seat appears to be nicked
or worn, invert the seat or replace it with the spare valve
seat located on the float arm. Inspect the water opening
in the valve body. If the opening is clogged, use a pin to
remove the obstruction. Remove any accumulated de-
posits from the valve body and float arm.
7. Clean the water pan and unit cabinet. Tilt the water pan
and lift it from the unit. Wash the pan with warm, soapy
water. Flex the pan to loosen accumulated scale. Wash
the unit interior, removing any accumulated deposits. In-
spect the drain line to ensure that no blockage has oc-
curred. Clean as required. (See Fig. 10.)
8. Reassemble your humidifier. Reinsert the water pan and
drain plug. Ensure that the overflow tube is inserted into
the hole at the bottom of the cabinet. Attach the float arm
to the valve body by aligning the holes on both parts and
reinserting the pin. Do not force or bend the pin. The float
arm should have free up-and-down movement. Install the
evaporator pad assembly. Ensure that the square shaft en-
gages the motor coupling and that the bearing washer is
located inside the bearing retainer. Turn the water on. Ad-
just float by rotating until water covers inside of foam
drum. Attach the access door and turn the latches.
9. Turn on electrical power supplies. Refer to start-up pro-
cedures listed on page 2.
BEFORE YOU REQUEST A SERVICE CALL
Before You Call For Service, Check For These Eas-
ily Solved Problems:
Check the main power disconnect switch. Verify that the
circuit beakers are on and that fuses have not blown. If
you must reset breakers or replace fuses, do so only once.
Contact your servicing dealer for assistance if the break-
ers trip or the fuses blow a second time.
If the humidity level is too low, check the humidistat set-
ting. Confirm that the saddle valve is turned on. Check the
evaporator pad, and clean or replace the pad as necessary.
Check water level in P110-WTR2019A humidifier.
Check for sufficient airflow. Check the furnace filter or elec-
tronic air cleaner for excessive accumulations of dirt. Check
for blocked return- or supply-air grilles. Be sure grilles are
open and unobstructed.
If water drips from the humidifier, check the drain hose
for kinks or obstructions. On P110-WTR2019A humidi-
fiers, dripping may indicate that the float valve requires
adjustment.
If your comfort system still fails to operate properly, con-
tact your servicing dealer for troubleshooting and repairs.
Specify your apparent problem, and state the model and
serial numbers of your equipment. (You should have them
recorded where noted in this booklet.) With this informa-
tion, your dealer may be able to offer helpful suggestions
over the phone, or safe valuable time through knowledge-
able preparation for the service call.
Regular Dealer Maintenance In addition to the rou-
tine maintenance that you perform, your humidifier should
be inspected regularly by a properly trained service techni-
cian. The inspection (preferably each year, but at least every
other year) should include the following:
Routine inspection of the humidifier. Cleaning, if nec-
essary. Cleaning or replacement of the evaporator pad
as required.
A check of all electrical wiring and connections.
A check of water connections to the unit.
Operational check of the complete comfort system to
determine actual working condition. Necessary repair
and/or adjustment should be performed at this time.
Your servicing dealer may offer an economical service
contract that covers seasonal inspections. Ask for further
details.
HUMIDIFIER HOUSING
WATER PAN
OVERFLOW TUBE
DRAIN PLUG
Fig. 10 Cleaning Water Pan and Unit Cabinet
P110-WTR2019A
FLOAT ARM
PIN
VALVE SEAT
VALVE
BODY
HIGHER
LOWER
Fig. 11 Float Arm Removal P110-WTR2019A
4
SERVICE INFORMATION
Record the model and serial numbers of your new humidifier in the following spaces.
This information, along with the other ready-reference facts requested below, may be
required if you should ever need information or service.
Model No.
Serial No.
Date Installed
Dealer Name
Address
City
State Zip
Telephone
5
6
Your Assurance of Quality
ALL Totaline products are backed with a one-year
warranty by Carrier Corporation, the world’s
largestmanufacturer ofair conditioning,heating, and
refrigeration products.
Manufacturer reserves the right to discontinue, or
change at any time, specifications or designs
without notice and without incurring obligations.
REPLACEMENT COMPONENTS DIVISION LITERATURE NUMBER HUM-50SO
R CARRIER CORPORATION 1/99 REPLACES 2-05930
PRINTED IN U.S.A.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

TOTALINE HUMCCLFP1218 Owner's manual

Category
Humidifiers
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI