Comtech EF Data CSAT-5060 Operating instructions

Type
Operating instructions
Part Number MN/CSAT506050.IOM Revision 0
CSAT
-
506
0
50 Wat
t
C-Band Transceive
r
Installation and Operation Manual
Filename: T_ERRATA 1
Errata A
Comtech EF Data Documentation Update
Subject:
Revised format for Redundant Kits descriptions
Date:
September 17, 2002
Document:
CSAT5060 50Watt, C-Band Transceiver, Installation and
Operation Manual, Rev. 0, dated April 23, 2002
Part Number:
MN/C506050.EA0
Collating Instructions:
Attach this page to page 2-12
Comments:
Revised format for Redundant Kits descriptions
Change Specifics:
2.6 REDUNDANCY CONFIGURATION
2.6.1 MOUNTING KIT
Table 2-1. Final 1:1, C-Band Assembly (Switching), AS/0458
Part No. Description QTY
AS/0438 Kit, LNA Switching 1
AS/0440 Kit, Cable 1:1 1
AS/0460 Kit, Waveguide CRP137G 1
AS/0461 Kit, Waveguide CRP229 1
AS/0462 Switch, Waveguide, TX 1:1 1
AS/0490 Assy, Remote Switch Box 1
Table 2-2. 1:1 Mounting Assembly, AS/0597
Part No. Description QTY
*AS/0414 Redundancy Kit, Pole Mount 2
*AS/0415 Single-Thread Mounting Kit 2
AS/0437 Switch, Mount Kit TX 1
IMPORTANT
*Refer to Single-Thread Configuration.
Filename: T_ERRATA 2
Filename: T_ERRATA 1
Errata B
Comtech EF Data Documentation Update
Subject:
Delete C-Band Filter from Mounting Kit AS/0438
Date:
September 17, 2002
Document:
CSAT5060 50Watt, C-Band Transceiver, Installation and
Operation Manual, Rev. 0, dated April 23, 2002
Part Number:
MN/C506050.EB0
Collating Instructions:
Attach this page to page 2-14
Comments:
Deleted C-Band Filter P/N RF/TRF-CBND-WG from Mounting Kit
AS/0438. Filter to be ordered separately.
Change Specifics:
Item Part No. Nomenclature QTY
1 15D1002 Cover 2
2 FP/BR0076 Bracket, Switch 1
3 28P1084 Adapter 1
4 Not Used
5 SW/WG2AGSM Switch, CPR229 +24V, Sealed 1
6 Not Used
7 HW/M6X1X15MMHEX Bolt, Hex head 36
8 HW/M6LOCK Washer, Lock 36
9 HW/M6X1X15MMFLATSS Screw, Flat 4
10 CN/CX50NMALE
CN – 5Ω, N Male Termination
1
11 GA/GSKTCPR229FULL Gasket, CPR229 4
12 HW/M6FLAT Washer, Flat 36
AS-0502 TX/RX Filter Support Bracket 1
Figure 2-1. Mounting LNA Switch Kit, AS/0438
Filename: T_ERRATA 2
Filename: T_ERRATA 1
Errata C
Comtech EF Data Documentation Update
Subject:
Revised Assembly Procedures for TRF Filter
Date:
September 17, 2002
Document:
CSAT5060 50Watt, C-Band Transceiver, Installation and
Operation Manual, Rev. 0, dated April 23, 2002
Part Number:
MN/C506050.EC0
Collating Instructions:
Attach this page to page 2-23
Comments:
Revised Important Note and step 7 to read:
IMPORTANT
Ensure that the OUTPUT flange of the filter is against switch (5).
TRF Filter is Customer-Selectable at time of ordering.
7. Position TRF Filter (customer-selectable), gasket (Table 2-7, Item 11), and
Support Bracket (Table 2-8, Figure 2-12, AS/0502) on Port 4 of switch (Table 2-
7, Item 5) and secure with 8 bolts (Table 2-8, Item 3), lockwashers (Table 2-8,
Item 2), and flat washers (Table 2-8, Item 1) from AS/0502 kit, and use 2 bolts
(Table 2-7, Item 7, Figure 2-11), lockwashers (Table 2-7, Item 8), and flat
washers (Table 2-7, Item 12) from AS/438 kit.
Filename: T_ERRATA 2
Filename: T_ERRATA 1
Errata D
Comtech EF Data Documentation Update
Subject:
Change Specification Temperatiures
Date:
December 16, 2002
Document:
CSAT5060 50Watt, C-Band Transceiver, Installation and
Operation Manual, Rev. 0, dated April 23, 2002
Part Number:
MN/C506050.ED0
Collating Instructions:
Attach this page following page 3
Comments:
Revised temperatures as specified in the Specification list. This information will be incorporatedf into the
next revision.
Change Specifics:
Revise temperatures as follows:
-50°C = -58°F
75°C = 167°F
55°C = 131°F
Filename: T_ERRATA 2
s:\tpubs\manuals\released_word\transceivers\csat5060 50w rev0\errata\mn-c506050.ee0.doc
1
Errata E
Comtech EF Data Documentation Update
Subject:
Changes to Appendix B (Supported Communications)
Date:
June 18, 2003
Document:
CSAT-5060 50 Watt C-Band Transceiver Installation and
Operation Manual, Rev. 0, dated April 23, 2002
Part Number:
MN/C506050.EE0
Collating Instructions:
Attach this page to page B-1
Comments:
The following changes provide updated information for Appendix B. This information will be
incorporated into the next revision.
Change Specifics:
Appendix B.REDUNDANT SYSTEMS
B.1 Redundant System
B-1
B.2 RSU-5060 Operation
B-6
B.3 Configuring A Redundant System
B-9
The CSAT-5060, 50 Watt C-Band Transceiver is capable of operating in both stand-alone
and redundant configurations. The CSAT fully redundant system provides automatic
detection, switching, and status for both its configuration and health. The system is
designed such that stand-alone operation is a functional sub-set of the fully redundant
CSAT system. This provides the user with transparent functionality regardless of the
mode or complexity the system has been setup to operate in.
IMPORTANT
Due to the parallel nature of the M&C interface, only EIA-485 and EIA-422
communications are supported through this device.
Errata F
Comtech EF Data Documentation Update
Subject:
Add Installation Guidelines
Date:
July 2, 2003
Document:
CSAT-5060 50 Watt C-Band Transceiver Installation and
Operation Manual, Rev. 0, dated April 23, 2002
Part Number:
MN/C506050.EF0
Collating Instructions:
Attach this page to Preface, page ix
Comments:
The following changes provide updated information for Preface. This information will be
incorporated into the next revision.
s:\tpubs\manuals\released_word\transceivers\csat5060 50w rev0\errata\mn-c506050.ef0.doc
1
s:\tpubs\manuals\released_word\transceivers\csat5060 50w rev0\errata\mn-c506050.ef0.doc
2
Change Specifics:
Installation guidelines regarding power line quality
As a company with many years of experience selling and servicing equipment installed around
the world, Comtech EF Data has become familiar with the varying quality of the AC power grid
around the world. The following offers some installation guidelines that should help ensure a
reliable installation.
• Surge suppression: High voltage surges can cause failure of the power supply. These
surges are typically caused by circuit switching on the main AC power grid, erratic
generator operation, and also by lightning strikes. While the transceiver does have built
in surge suppression, if the unit will be installed in a location with questionable power
grid quality, Comtech EF Data recommends installation of additional power
conditioning/surge suppression at the power junction box.
• Grounding: The transceiver provides a grounding terminal. This is provided to allow
the user to ground the transceiver to the antenna’s grounding network. All components
installed at the antenna should be grounded to a common grounding point at the
antenna.
• Electrical welding: If welding needs to take place at the antenna, disconnect all cables
from the transceiver except for the ground wire. Cap all RF connections with
terminations. This will prevent damage to the input/output circuitry of the transceiver.
• Lightning: Lightning strikes on or around the antenna will generate extremely high
voltages on all cables connected to the transceiver. Depending on the severity of the
strike, the transceivers internal surge protection combined with the recommended
external suppression may protect the transceivers power supply. However, if the
installation will be in an area with a high probability of lightning strikes, Comtech EF Data
recommends the installation of surge suppression on the RF and IF cables. One source
of these suppressors is PolyPhaser (
www.polyphaser.com
)
For further information, please contact Comtech EF Data, Customer Support Department.
Errata F
Comtech EF Data Documentation Update
Subject:
Add Installation Guidelines
Date:
July 2, 2003
Document:
CSAT-5060 50 Watt C-Band Transceiver Installation and
Operation Manual, Rev. 0, dated April 23, 2002
Part Number:
MN/C506050.EF0
Collating Instructions:
Attach this page to Preface, page ix
Comments:
The following changes provide updated information for Preface. This information will be
incorporated into the next revision.
s:\tpubs\manuals\released_word\transceivers\csat5060 50w rev0\errata\mn-c506050.ef0.doc
1
s:\tpubs\manuals\released_word\transceivers\csat5060 50w rev0\errata\mn-c506050.ef0.doc
2
Change Specifics:
Installation guidelines regarding power line quality
As a company with many years of experience selling and servicing equipment installed around
the world, Comtech EF Data has become familiar with the varying quality of the AC power grid
around the world. The following offers some installation guidelines that should help ensure a
reliable installation.
• Surge suppression: High voltage surges can cause failure of the power supply. These
surges are typically caused by circuit switching on the main AC power grid, erratic
generator operation, and also by lightning strikes. While the transceiver does have built
in surge suppression, if the unit will be installed in a location with questionable power
grid quality, Comtech EF Data recommends installation of additional power
conditioning/surge suppression at the power junction box.
• Grounding: The transceiver provides a grounding terminal. This is provided to allow
the user to ground the transceiver to the antenna’s grounding network. All components
installed at the antenna should be grounded to a common grounding point at the
antenna.
• Electrical welding: If welding needs to take place at the antenna, disconnect all cables
from the transceiver except for the ground wire. Cap all RF connections with
terminations. This will prevent damage to the input/output circuitry of the transceiver.
• Lightning: Lightning strikes on or around the antenna will generate extremely high
voltages on all cables connected to the transceiver. Depending on the severity of the
strike, the transceivers internal surge protection combined with the recommended
external suppression may protect the transceivers power supply. However, if the
installation will be in an area with a high probability of lightning strikes, Comtech EF Data
recommends the installation of surge suppression on the RF and IF cables. One source
of these suppressors is PolyPhaser (
www.polyphaser.com
)
For further information, please contact Comtech EF Data, Customer Support Department.
Copyright © Comtech EF Data, 2002. All rights reserved. Printed in the USA.
Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, (480) 333-2200, FAX: (480) 333-2161.
CSAT-5060
50 Watt
C-Band Transceiver
Installation and Operation Manual
Part Number MN/CSAT506050.IOM
Revision 0
April 23,2002
Comtech EF Data is an ISO
9001 Registered Company.
ii
Customer Support
Contact the Comtech EF Data Customer Support Department for:
• Product support or training
• Information on upgrading or returning a product
• Reporting comments or suggestions concerning manuals
A Customer Support representative may be reached at:
Comtech EF Data
Attention: Customer Support Department
2114 West 7th Street
Tempe, Arizona 85281 USA
480.333.2200 (Main Comtech EF Data Number)
480.333.4357 (Customer Support Desk)
480.333.2161 FAX
or, E-Mail can be sent to the Customer Support Department at:
Contact us via the web at www.comtechefdata.com
.
1. To return a Comtech EF Data product (in-warranty and out-of-warranty) for
repair or replacement:
2. Request a Return Material Authorization (RMA) number from the Comtech EF
Data Customer Support Department.
3. Be prepared to supply the Customer Support representative with the model
number, serial number, and a description of the problem.
4. To ensure that the product is not damaged during shipping, pack the product in
its original shipping carton/packaging.
5. Ship the product back to Comtech EF Data. (Shipping charges should be
prepaid.)
For more information regarding the warranty policies, see Warranty Policy, p. x.
iii
Table of Contents
Customer Support.......................................................................................................................................ii
About this Manual ...................................................................................................................................viii
Conventions and References..................................................................................................................viii
Reporting Comments or Suggestions Concerning this Manual.............................................................viii
Safety Notice...............................................................................................................................................ix
Warranty Policy..........................................................................................................................................x
CHAPTER 1.
INTRODUCTION.............................................................................................1–1
1.1 Functional Description .....................................................................................................................1–1
CHAPTER 2. INSTALLATION ..............................................................................................2–1
2.1 Unpacking and Inspection................................................................................................................2–1
2.2 Personnel............................................................................................................................................2–2
2.3 Tools Required..................................................................................................................................2–2
2.4 Single-Thread Configuration...........................................................................................................2–3
2.4.1 Mounting Kits..............................................................................................................................2–3
2.4.2 Single-Thread Installation............................................................................................................2–6
2.4.3 LNA Installation ........................................................................................................................2–10
2.5 Cable Installation............................................................................................................................2–11
2.6 Redudancy Configuration..............................................................................................................2–12
2.6.1 Mounting Kit..............................................................................................................................2–12
2.6.2 Redundancy Installation.............................................................................................................2–20
CSAT5060 50W C-Band Transceiver Revision 0
Preface MN/CSAT506050.IOM
iv
2.7 LNA Assembly.................................................................................................................................2–28
2.8 Cable Installation............................................................................................................................2–29
CHAPTER 3. SYSTEM OPERATION....................................................................................3–1
3.1 Pin-outs..............................................................................................................................................3–1
3.1.1 Connector J3: AC Power, Mains, 100 to 125 VAC, or 205 to 240 VAC.................................3–1
3.1.2 Connector J5: COMM, Remote communications port.............................................................3–2
3.2 Turning On the CSAT......................................................................................................................3–3
3.3 Configuring the CSAT......................................................................................................................3–3
3.3.1 Frequency.....................................................................................................................................3–3
3.3.2 Attenuation...................................................................................................................................3–3
3.3.3 Gain Offset...................................................................................................................................3–4
3.3.4 Mute Mode...................................................................................................................................3–4
3.3.5 Mute.............................................................................................................................................3–5
3.3.6 Tx Amplifier ................................................................................................................................3–5
3.3.7 Channel Slope Adjust Mode........................................................................................................3–5
3.3.8 Channel Slope Adjust...................................................................................................................3–6
3.3.9 Reference Frequency Adjust........................................................................................................3–6
3.3.10 External Reference Fault Logic .................................................................................................3–6
3.3.11 Cold Start Function....................................................................................................................3–7
3.3.12 Auto Fault Recovery..................................................................................................................3–7
3.3.13 LNA Current Source..................................................................................................................3–8
3.3.14 LNA Current Calibration and Current Window.........................................................................3–8
3.3.15 LNA Fault Logic........................................................................................................................3–8
3.3.16 Redundancy Controller Auto/Manual........................................................................................3–9
3.3.17 Redundancy Controller Toggle..................................................................................................3–9
3.3.18 Set Physical Address..................................................................................................................3–9
3.3.19 Set Baud Rate...........................................................................................................................3–10
3.3.20 Set Date....................................................................................................................................3–10
3.3.21 Set Time...................................................................................................................................3–10
APPENDIX A. REMOTE CONTROL.........................................................................................1
A.1 Introduction..........................................................................................................................................1
A.1.1 EIA-485...........................................................................................................................................1
A.1.2 EIA-232...........................................................................................................................................1
A.2 Basic Protocol.......................................................................................................................................2
A.2.1 Packet Structure ..............................................................................................................................3
A.3 Commands or Responses.....................................................................................................................6
APPENDIX B. REDUNDANT SYSTEMS..................................................................................1
B.1 Redundant System................................................................................................................................1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115

Comtech EF Data CSAT-5060 Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI