Intermatic ET1100 Series Installation and User Instructions

  • Hello! I am an AI chatbot trained to assist you with the Intermatic ET1100 Series Installation and User Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Electronic 24-Hour
Time Switch
Time Switch
Input Voltage: 120/208/240/277 VAC, 50/60 Hz•
Power Consumption: 6.0 watts max.•
ContactConguration:SPST(ET1105C),DPST(ET1125C),and•
SPDT(ET1115C).Seewiringdiagramsonnextpage.
Switch Ratings—ET1105C, ET1125C (per pole)
30AInductive/Resistive:24/120/208/240/277VAC,60Hz•
20A Ballast: 120-277 VAC, 60 Hz•
20AResistive:28VDC•
5ATungsten:120/240VAC,60Hz•
1 HP: 120 VAC, 60 Hz•
2 HP: 240 VAC, 60 Hz•
Switch Ratings—ET1115C (NO/NC) Normally Open/Normally Closed Contact
20A/10AInductive/Resistive:120/208/240/277VAC,60Hz•
20A/10AResistive:28VDC•
6A/3A Ballast: 120-277 VAC, 60 Hz•
5A/3A:120/240VACTungsten•
1 HP / ¼ HP: 120 VAC, 60 Hz•
2 HP / ½ HP: 240 VAC, 60 Hz•
Set Points (Events)—EachloadoutputoftheTimeSwitchcansupport
upto14timedONand14timedOFFeventsperday.
Battery-Powered Clock Operation—2yearsminimum(uses2AAA
industrialgradealkalinebatteries,supplied)
Minimum ON or OFF time—1 minute
Maximum ON or OFF time—23hours,59minutes
Shipping Weight—2.5lb.(1.1kg)
Enclosures—Threeenclosureoptionsareavailable.
ET11x5C–NEMA1indoormetalenclosure•
ET11x5CR–NEMA3Rindoor/outdoorlockablemetalenclosure•
ET11x5CPD82–NEMA3Rindoor/outdoorlockableimpactresis-•
tantpolycarbonateenclosurewithclearcover
Knockouts—Combination1/2-3/4inchsize,1onbackandeachside,
2onbottom
Wire Size—AWG#10through#18
Installation and User Instructions
MODEL ET1100 Series
TheIntermaticET1100SeriesElectronic24-HourTimeSwitch
automaticallyswitchesloadstoapresetdailyschedulewithto-the-
minuteaccuracy.
UsetheET1100seriesasanON/OFFtimerinapplicationsrequir-
ing24-hourloadcontrolsuchaslighting,airconditioningsystems,
pumps,etc.EachloadoutputoftheTimeSwitchcansupportupto
14timedONand14timedOFFeventsperday.Theprogramcanbe
overriddenbypushingtheON/OFFloadoverridebutton(s).
TheET1100SeriesTimeSwitchisdesignedtodirectlyswitchtung-
stenorballastloadsuptoitsrating,andinductiveorresistiveloads
up to 30A at 120, 208, 240, or 277 VAC.
Specifications
With Battery
Carryover
Description
WARNING: Disconnect the
power to the Time Switch
and the loads before instal-
lation.
Removethemecha-1.
nismfromthecaseby
depressingthecatchat
thetopofthecaseand
pullingout,asshown.
CAUTION: Do not
touch circuit board
components since
static discharge could damage the microprocessor.
Setvoltageselectorfordesiredinputvoltage.2.
Thetimerisshippedwithvoltagesetfor120
VAC.Tooperateat208,240or277VAC,move
theselectorswitchtothedesiredsettingas
markedonthecircuitboard.SeelocationA in
Rear Viewaboveanddetailattheright.
ThetimerisshippedwithDST(DaylightSav-3.
ingTime)enabled.TodisableDST,insertajumperatlocation
markedDST.SeelocationB in Rear Viewabove
anddetailattheright.
ET1125C ONLY4. —Decidewhetheryouwant
tocontrolmultipleloadssimultaneously(SIM),
independently(IND),orwitha2-secondpulse
(PUL)(e.g.,forusewithmechanicallyheldcon-
tactorsorbellringingapplications),andmakesurethejumperis
positionedaccordingly.SeelocationB in Rear Viewaboveand
detailattheright.(TheunitisshippedwiththeloadssetforIND.)
Installation Instructions
Slide down
to remove
battery case
Snap out catch
Tilt top forward
Front View
Rear View
B
A
Electrical shock hazard. To avoid fire, shock, or death, disconnect all •
power before installing or servicing time switch or connected loads.
Follow local electrical and safety codes, National Electric Code (NEC) •
and Occupational Safety and Health Act Codes (OSHA).
If the power disconnect point is out of sight, lock it in the OFF position •
and tag it to prevent unexpected application of power.
This time switch must be grounded.•
Do not exceed maximum current carrying capacity.•
Always replace the plastic insulator covering the terminal before •
powering ON.
WARNING–Risk of Fire or Electric Shock
Mounttheenclosureinthedesiredlocationusingthe3mount-5.
ingholesprovided.
Position at eye level if possible, providing space to the left of
the enclosure for the cover to swing open fully, as shown.
Replacethemechanismintheenclosure.6.
Lifttheleftsideoftheplasticinsulatorofftheretainingpostand7.
pivotitupandawaytoexposetheterminalstrip.
Stripthesupplyandloadwiresto1/2”.8.
Use AWG#10-#18 copper conductors only.
Knockouts
Mounting holes
1
Neutral
120VAC
Input
Hot
2 3 4
Timer Power
Load
Install jumper
only if timer input
and load voltage
are the same
ET1105 configured for SPST, 120 VAC load
1
Line 2
120/208/240/277
VAC Input
Line 1
2 3 4 5 6
Load
1
Load
2
Timer Power
ET1115 configured for SPDT load switching
1
Line 2
240VAC Input
Line 1
2 3 4 5 6
Line 1
Line 2
Install jumper only if timer input
and load voltage are the same
Timer Power
Load
ET1125 configured for 240VAC DPST load
with jumper set to SIM
1
Line 2
120/208/240/277
VAC Input
Line 1
2 3 4 5 6
ON
Install jumper only if timer input
and load voltage are the same
OFF
Timer Power
ET1125 configured for pulse SPST load
with jumper set to PUL
1
Line 2
120/208/240/277
VAC Input
Line 1
2 3 4 5 6
Load
1
Timer Power
Load
2
ET1125 configured for 2 SPST loads
with jumper set to IND
1
Line 2
120/208/240/277
VAC Input
Line 1
2 3 4 5 6
Load
1
Timer Power
Load
2
ET1125 configured for DPST loads
with jumper set to SIM
Mounting
hole
Knockouts
Mounting
hole
Insertthewireendsundertheproperterminalplates(seewir-9.
ingdiagramselsewhereonthispage)andtightenthescrews
rmly.
Connectgroundwiretogroundingterminalatbottomofenclosure.10.
Replacetheplasticinsulatorontheretainingpost.11.
Removethebatterycasebyslidingitdownasshownbythe12.
arrows,theninstall2AAAalkalinebatteries.Makesurethe
batteriesarepointinginthedirectionshown.
Verifythatthedisplayis13. ONtomakesurethebatteriesareOK.
If the display shows scrambled information, press the RESET
button to clear it up.
ApplypowertotheTimeSwitch.14.
IMPORTANT: 15. PressandholdtheENTERbutton,thenpressthe
RESETbutton.Thescreenwillash12:00AM,andtimerstatusis
ManualMode.
NOTE: You must reset the time switch using this procedure
whenever you change the jumpers.
The Time Switch is now ready for programming.
Programming Overview
BypressingtheMODEbutton,theTimeSwitchwillcyclethroughthe
menusnecessaryforprogrammingthecurrenttime,date,andtimed
events.
ThebasicprocedureistousetheMODEbuttontomovefromone
menutothenext(e.g.,DATE,TIME,etc.),the+ or buttonsforthe
rstpartofasetting(e.g.,MONTH),theENTERbuttontomoveto
thenextpartofthesetting(e.g.,YEAR),thenMODEtoexitandmove
tothenextmenu.Toskipamenu,pressMODEtomoveahead.
If you make a mistake, press the MODE button repeatedly to cycle
back around to the error, then make the correct entry.
NOTE: DATE and TIME must be set before you can access any
other programming menus.
1 – Setting Date
Pressthe1. MODEbuttonrepeatedlyuntilthewordsSETand
DATEappearintheupperareaofthedisplay.
Pressthe2. + or buttonstoenterthecurrentMonth.
Pressthe3. ENTERbuttonwhentheMonthiscorrecttosavethe
setting.ThescreenadvancestocurrentDate.
Againpressthe4. + or buttonstoenterthecurrentDate,fol-
lowedbytheENTERbutton.
RepeattosetthecorrectYear.5.
Pressthe6. MODEbuttontoexitandadvancetosettingthetime.
2 – Setting Time
Ifnecessary,pressthe1. MODEbuttonrepeatedlyuntilthewords
SETandCLOCKappearintheupperareaofthedisplay.
Pressthe2. + or buttonstoenterthecurrenttime.
NOTE: To go from AM to PM, keep pressing the + or but-
tons to cycle through the day. You can hold the + or but-
tons down for 3 seconds to make the time scroll quickly.
Pressthe3. MODEbuttontoexitandadvancetosettingevents.
Ifnecessary,pressthe1. MODEbuttonrepeatedlyuntilthewords
SET,FIXED,ON/OFFEVENTandEVENT1appearonthe
display.
Ifnecessary,pressthe2. ENTERbuttontodisplayON@orOFF@
(dependingonwhatyouwanttoset).
Pressthe3. + or buttonstoenterthetimeyouwanttoset.
NOTE: To go from AM to PM, keep pressing the + or but-
tons to cycle through the day. You can hold the + or but-
tons down for 3 seconds to make the time scroll quickly.
ET1125C ONLY4. —Foramulti-circuitdevicewithloadsset
independently,youcanchoosetheloadyouwanttheeventto
control.Thedefaultsettingisforbothloads,asyoucanseeon
thedisplay.PresstheON/OFFbuttonunderaloadtoremovethe
loadfromtheevent.
Whenyouhavesettheeventcorrectly,youhavetwochoices:5.
Pressthe - ENTERbuttontosetthenextxedtimeevent(upto
28events).
Pressthe - MODEbuttontoexit.
3 – Setting Fixed Timed Events
PresstheMODEbuttonrepeatedlytoselectthedesiredoperating
modeonthedisplay.Thereare2options:
AUTO• —wheretheTimeSwitchfollowstheeventsyouhavepro-
grammed,turningthecircuitsONandOFFatthetime(s)set.
NOTE: You can override programmed events and force the
Time Switch ON or OFF by pressing theON/OFF button.
MANUAL• —whereanyeventssetaredisabledandtheTime
SwitchcontrolsallcircuitsthroughtheON/OFFbutton.
NOTE: You can review or edit any programmed events at any time
by pressing the MODE button repeatedly to return to the appropriate
menu, then following programming instruction provided on this sheet.
Operating the Time Switch
Usethisproceduretoclearthesettingsprogrammedforanevent.
Ifnecessary,pressthe1. MODEbuttonrepeatedlyuntilthewords
SET,FIXED,andON/OFFEVENTSareshownonthedisplay.
Pressthe2. ENTERbuttonasnecessarytocyclethroughevents
thathavebeensetuntilyouseetheeventyouwanttodelete.
Pressthe3. + or buttonsATTHESAMETIMEtodisplay--:----.
Pressthe4. MODEbuttontoexit.
OPTIONAL – Deleting (Clearing) an Event
LIMITED ONE-YEAR WARRANTY
If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole op-
tion, free of charge. This warranty is extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused
by accident, dropping or abuse in handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise
modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LED’s and batteries; (f) the
finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal
costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS
OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD
STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of purchase,
postage prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove, Illinois 60081-
9698/815-675-7000 http://www.intermatic.com Please be sure to wrap the product securely to avoid shipping damage.
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
158--00xxx
BatteriescanbeeasilyreplacedwithoutremovingtheTime•
Switchmechanismoreldwiring.
Pressinanddownward(inthedirectionofthearrows)onthe•
batterycover.
Itisrecommendedtoreplacethebatteriesevery2-3yearswith•
2AAAindustrialgradealkalinecellsaspartofnormalmainte-
nanceontheTimeSwitch.
Besuretoobservebatterypolaritymarkingswheninstalling•
batteries.
Nootherbatterymaintenanceisrequired.•
Battery Maintenance
/