Features
§ No moving parts and no contact with the
liquid
§ No maintenance
§ Highest reliability
§ Easy installation
§ High accuracy
§ Handles difficult process conditions due to
ultra-high sensitivity and unique signal
processing features
§ High flexibility with interchangeable
Transmitter Heads and antennas
§ A wide array of antennas and versions for
best performance in all applications
§ Interactive setup with Windows based PC
software or via local display with keyboard
§ Analog 4-20 mA superimposed with
HART
®
, and digital Profibus DP or TRL2
field bus outputs
Measurement principle
The level of the liquid (or solid) is measured
by radar signals transmitted from the antenna
at the tank top. After the radar signal is
reflected by the liquid surface the echo is
picked up by the antenna. As the signal is
varying in frequency the echo has a slightly
different frequency compared to the signal
transmitted at that moment. The difference in
frequency is proportional to the distance to the
liquid, and can be accurately calculated. This
method is called FMCW (Frequency Modula-
ted Continuous Wave) and is used in all high
performance radar gauges.
Saab TankRadar
®
Pro uses the 10 GHz fre-
quency band to get optimum balance between
beam width and sensitivity to antenna con-
tamination.
Saab TankRadar
®
Pro
with its flexible con-
figuration is suitable for
both stand-alone appli-
cations and large-scale
plant installations with
various tank types.
The FMCW method is
based on a radar sweep
with continuous
changes in frequency.
Frequency (GHz)
f
f
f
f
max
f
min
1
f
1
f
0
f
0
t
0
t
t
td
d
1
Time
Transmitted
Reflected
4
Technical Description
Applications
Saab TankRadar Pro uses state-of-the art
microwave technology to get highest reliability
and precision. It measures the level of liquids,
slurries as well as many solids. The gauge
operates in a wide range of temperatures,
pressures, vapor gas mixtures and various pro-
cess conditions.
The applications include:
§ Chemical & petrochemical storage and
process tanks
§ Pharmaceutical reactors
§ Food and beverage manufacturing
§ Refinery process vessels
§ Water and sewage treatment
§ Hydroelectric power generation and dams
§ Cement, powder, wood chips and other
solid material applications
Applications in process
vessels with agitators
require a radar gauge
with TankRadar Pro’s
high sensitivity and
advanced signal pro-
cessing to separate the
measuring signal from
noise created by dis-
turbances.
Still-pipe or bridle
mounting is recommen-
ded for LPG applica-
tions, where the surface
sometimes is boiling,
and for some extremely
turbulent conditions.
The pipe reduces foam
and turbulence and also
increases surface re-
flection.
The rod antenna is
suitable for small nozzle
openings on tanks with
calm surfaces and short
measuring ranges.
Solid materials, like
cement, often give
extremely small radar
reflections, requiring the
most sensitive antenna,
the 20” parabolic.
5
Technical Description
Select the right Pro gauge
A TankRadar Pro gauge consists of a Transmit-
ter Head (TH) and a tank connection including
antenna. The TH, as well as the electronics in-
side, is interchangeable without opening the
tank.
The Transmitter Head is available in three
basic versions:
§ Lite
Intended for applications in non-hazardous
areas only. Suitable for tanks without
internal structures and agitators, e.g. certain
storage tanks, water, dam applications etc.
The Lite version has only FFT calculations
enabled providing an instrument accuracy
of ±10 mm (±0.4"). Echofixer, FHAST and
MET are available as options.
§ Standard
For hazardous applications, suitable for
most tanks, also with internal structures,
spherical and bullet tanks. The Standard
version includes the Echofixer software
which more accurately than standard FFT
maps all microwave interference sources.
Standard instrument accuracy is ±10 mm
(±0.4") which can be improved to ±5 mm
(±0.2") using the optional software
modules.
§ Gold
Gold is the most advanced version for
difficult applications in tanks with agitators,
heating coils and other disturbances. It
includes the Echofixer software, FHAST™
software for increased accuracy plus
MET™ software for further increased
disturbance echo handling. Instrument
accuracy is ±5 mm (±0.2").
Volume calculation for symmetrical tanks is
included in all versions. Strapping table for
non-symmetrical tanks is available as an op-
tion.
Various options make it possible to optimize the
gauge for different applications:
§ Fast Fourier Transformation (FFT)
Fast Fourier Transformation is a signal
processing technique used to map the
echo structure of the tank.
§ Echofixer
A software module that makes it
possible to measure on the surface in
spite of strong disturbance echoes from
mechanical structures such as agitators
and baffles.
§ Fast High Accuracy Signal
Technology (FHAST™)
A module that improves the efficiency of
the signal processing by limiting the
region to be analyzed around the surface.
This results in an improved accuracy of
±5 mm (±0.2").
§ Multiple Echo Tracking (MET™)
Improves the resolution and accuracy in
echo disturbed regions and close to the
tank bottom. Continuous measurement
on multiple disturbing echoes facilitates
identification of the actual surface echo.
All software options are possible to upgrade in
the field without any changes in electronics.
Upgrades are made by entering a new start
code in the gauge and can be done on a
temporary basis for trial purposes.
Software modules
Software modules in available Pro versions
Increased Accuracy
Disturbance echo
handling
Improved resolution
x Option Option Option
xxOptionxOption
x x x x x
6
Technical Description
Antenna versions
Saab TankRadar
®
Pro can be equipped with
different antennas to fulfill various
requirements. The antenna is the only part
exposed to the tank atmosphere. The most
common antenna used is the cone type. When
selecting antenna dimension, it is generally
recommended to use as large antenna diame-
ter as possible.
Cone antenna
The cone antenna is suitable for a large range
of applications, both for free propagation and
still-pipe mounted installations. Thanks to the
unique flange clamp solution the existing tank
flange can be used as tank connection. The
gauge can also be delivered with flange
included.
§ 3", 4", 6" and 8" diameter tank openings.
The 3", 4" and 6" cones can be extended to
fit long tank nozzles. See page 17 for
standard flange options.
§ A 1" and a 2" version is available together
with a still-pipe solution.
§ Materials exposed to the tank atmosphere:
PTFE or quartz sealing, antenna in steel or
other metals, o-ring in Viton or Kalrez.
§ Special material such as Hastelloy C 22,
Titanium gr. 2, Monel 400 and Tantalum.
§ Accuracy up to ± 5 mm (0.4") using the
FHAST software option.
§ EEx IIC, Zone 0.
§ PTB Zone 0 approved.
See page 13 for description of still-pipe
installations.
The relation between
temperature and
maximum pressure.
70 (2.76) [2"cone]
95 (3.74) [3"cone]
56 (2.20) [2"cone]
70 (2.76) [3"cone]
93 (3.66) [4"cone]
141 (5.55) [6"cone]
189 (7.44) [8"cone]
150 (5.91) [4"cone]
260 (10.24) [6"cone]
370 (14. 57) [8"cone]
200 (7.87)
mm (inch)
400
(15.75)
Temperature (˚C)
Pressure (bar)
4002001000 300-40
60
55
50
40
30
20
10
-1
0
798
-15
145
73
0
Pressure (psig)
Temperature (˚F)
75239221232 570-40
1
2
Cone, Quartz
Cone, PTFE
1
2
The thin antenna plate
prevents the flange
from exposure to the
tank environment.
7
Technical Description
The relation between
temperature and
maximum pressure.
200 (7.87)
440
(17.32)
162
(6.4)
mm (inch)
445 (17.52)
Parabolic
The parabolic antenna is suitable for both
liquid and solid applications. As it has the
largest diameter it has the most narrow radar
beam and can be used for extremely long
measuring distances.
The parabolic is also the antenna type most
insensitive to contamination. It can be used in
applications with severe antenna condensation
like asphalt and liquid sulphur. Two versions
are available: the very easily installed version
with clamped mounting of flanges with a ø 96
mm (3.78 in.) hole in flange (low pressures) and
a welded version (high pressures).
§ Suitable in all tanks with 450 mm (18") or
larger openings.
§ Exposed parts in tank: Stainless steel and
PTFE.
§ Highest antenna gain.
§ Withstands heavy contamination.
§ Flexible PFTE radome available for dusty
applications.
§ Eex IIC.
§ PTB zone 0 approved.
Parabolic antenna
welded to tank
opening
Temperature (
˚
C)
Pressure (bar)
230
20050
100 150
0
-40
445
392122
212 302
32
-40
10
+0.2
0.5
0.5
-0.2
145
0
+2.9
-2.9
0
Pressure (psig)
Temperature (
˚
F)
573
1
1
2
Welded
Clamped
1
2
8
Technical Description
Rod Antenna
The small dimensions and the fact that only
PTFE is exposed to the tank atmosphere, makes
the rod antenna suitable for small tanks with
hygienic requirements or aggressive chemicals.
It is for 2" and 2 ½" nozzle connections only. If a
larger nozzle is used, a 2" insertion pipe is to be
installed. The Maximum nozzle height is 150
mm (6").
Accuracy is ±10 mm (±0.4") also with the
FHAST software option included. [The Pro
gauges with cone, parabolic and process seal
antennas gets ±5 mm (±0.2") accuracy with the
FHAST software.]
§ Withstands high pressures
§ 2" or 2.5" tank connections
§ Only PTFE exposed to tank atmosphere
§ Hygienic design
§ Accuracy ± 10 mm
§ EEx IIB, Zone 0
The relation between
temperature and
maximum pressure.
Min 49 (1.93)
Max 66 (2.60)
395
(15.55)
355
(13.98)
200 (7.87)
mm (inch)
Temperature (˚ C)
Pressure (bar)
4002001000 300-40
40
-0,5
0
-7
0
Pressure (psig)
Temperature (˚ F)
75239221232 570-40
30
20
10
25 362
35 507
9
Technical Description
Process seal
The dish made of PTFE or ceramics seals off
the cone shaped antenna from the tank
atmosphere. This combines the benefits of
using a cone antenna with the advantage of
only exposing material suitable for hygienic or
corrosive applications.
§ Suitable in hygienic or aggressive tank
atmospheres
§ Cone antenna protected from the tank
atmosphere by a ceramic or PTFE sealing
§ Ceramic seal withstands high pressures and
temperatures
§ 4" and 6" versions
§ 4" version for hazardous applications
(Ex IIB, Zone 0)
Tank connections
Flanges for all antenna types are available in
DIN, ANSI, ASME or JIS standards. Standard
flange material is hotdip galvanized carbon
steel. For complete listing of available stan-
dard flanges, see Antenna information, pages
17-19.
The relation between
temperature and
maximum pressure.
Temperature (˚ C)
Pressure (bar)
400200100 1500 300-40
20
-1
0
-15
0
Pressure (psig)
Temperature (˚ F)
75239221232 570-40
15
10
5
686
16 230
2
4" Process Seal, Ceramic
6" Process Seal, Ceramic
1
1
2
3
4
2
4" Process Seal, PTFE
3
6" Process Seal, PTFE
4
200 (7.87)
160 (6.30) [4" process seal]
218 (8.58) [6" process seal]
550 (21.65) [4" process seal]
650 (25.59) [6" process seal]
mm (inch)
10
Technical Description
Categories of liquids:
a: Oil, gasoline and other hydrocarbons,
petrochemicals
(dielectric constant, e
r
=1.9-4.0).
b: Alcohols, concentrated acids, organic
solvents, oil/water mixtures and acetone
(e
r
=4.0-10).
c: Conductive liquids, e.g. water based
solutions, dilute acids and alkalis
(e
r
> 10).
For liquids with e
r
smaller than 1.9 such as
liquefied gases, an 8" or bigger diameter antenna
is recommended if measurement is done with free
propagation. In this case the measuring range in
calm surface tanks is in typical cases 15 m (50 ft).
Measuring range
The diagrams below show how the measuring
range is influenced by the antenna type,
dielectric constant of the liquid (e
r
) and the
process conditions. For optimum performance
the maximum measuring distance should be
kept within the range indicated with darker
colour in the diagrams. Values are valid for
free propagation measurement without still-
pipes (bridles).
To increase the measuring range further in tur-
bulent tanks, a still-pipe can be used. For still-
pipe mounted Pro gauges the typical
measuring range is 35-50 m (115-160 ft) also in
turbulent tanks with liquids having e
r
less than
1.9.
Measuring range in
tanks with calm
surfaces.
Measuring range in
gently stirred tanks.
Measuring range in
agitated process tanks.
Rod/3" Cone(m) 4" Cone 6" Cone 8" Cone Parabolic
0
10
20
30
40
50
60
0
10
20
30
40
50
60
0
10
20
30
40
50
60
0
10
20
30
40
50
60
0
10
20
30
40
50
60
abc abc abc abc abc
4" Cone 6" Cone 8" Cone Parabolic
0
10
20
30
40
50
60
0
10
20
30
40
50
60
0
10
20
30
40
50
60
0
10
20
30
40
50
60
0
10
20
30
40
50
60
Rod/3" Cone(m)
abc abc abc abc abc
4" Cone 6" Cone 8" Cone Parabolic
0
10
20
30
40
50
60
0
10
20
30
40
50
60
0
10
20
30
40
50
60
0
10
20
30
40
50
60
0
10
20
30
40
50
60
Rod/3" Cone(m)
abc abc abc abc abc
11
Technical Description
Control System
Modem
4-20 mA/HART (Profibus DP or TRL2 bus communication)
Alarm
Relay
Unit
Remote
display
Hand Held HART
communicator
PC with Pro Setup/
TankMaster software
Temp
sensor
System integration
Level values are transmitted from the gauge as
analog 4-20 mA signals superimposed with
HART
®®
or digital signals (Profibus DP or
Saab’s Modbus based TRL2 field bus). The
analog outputs are either passive for
connection to powered cables or active provi-
ding signal power for display units etc. Analog
outputs can also be specified to be intrinsically
safe.
When using the digital TRL2 field bus outputs,
up to 12-15 gauges can be connected to each
two-wire field bus, maintaining a high data
updating speed. Each field bus is connected to
a Field Communication Unit (FCU) that hand-
les up to four field buses with data from a
maximum of 32 tanks. Several FCUs can be
installed to handle a large number of tanks.
From the FCU, data can be transmitted on
RS232/485 or TRL2 bus formats to host
computers (DCS, PC or PLC). Pro gauges with
TRL2 bus outputs can also be connected to the
TankMaster operator software providing an
OPC server that can be linked to the plant
network.
Data are displayed on the optional RDU40 dis-
play mounted on the gauge or separately. Via
the display, up to six temperature sensors can
be connected, if the display is mounted
separately. Configuration is easily done on the
4-key display keyboard.
Configuration can also be done on a HART
®®
communicator or on a PC using the Windows
based Pro Setup software package. Pro Setup
includes advanced graphics software tools,
including FFT disturbance echo tracking.
Temperature
Input
Hazardous Area
Safe Area
PC with Pro Setup/
TankMaster software
TankRadar Rex TankRadar Pro
Group
Buses
Field
Buses
Field
Communication
Unit
The intrinsically safe
Remote Display shows
level (m or ft) and
temperature (ºC or ºF)
and can be used for
gauge configuration.
12
Technical Description
Mechanical mounting
The TankRadar Pro gauge is easily carried to
the tank top and mounted on a suitable nozzle
or pipe.
The gauge should be installed as follows:
§ Antenna oriented perpendicular to a
horizontal surface.
§ The gauge should be mounted with as few
fittings as possible within the beam angle.
§ Filling inlets creating turbulence should
preferably be kept at a distance.
§ Choose as large antenna diameter as
possible. A larger receiving area
concentrates the radar beam and ensures
maximum antenna gain. Increased antenna
gain offers greater margin for weak surface
echoes.
Beam angle
Distance
5m
10m
15m
20m
The flat tank wall can be located within the
antenna beam angle, as long as there is a mini-
mum distance from the gauge to the tank wall,
see picture above.
An extended cone can be used for long
nozzles. The standard length of the extended
cone is 500 mm (20") for 3", 4" or 6" cone
antennas. Longer cones are available on
request.
For best measurement
performance the nozzle
height should be
shorter than the
antenna
Minimum distance m (ft):
-Cone antenna: 0.6 (2.0)
-Rod antenna: 0.3 (1.0)
-Process Seal antenna: 0.6 (2.0)
-Parabolic antenna: 0.6 (2.0)
10 mm (0.4")
or more
Half power
beam width
Diameter of radiated area
Distance, m (ft) Diameter, m (ft)
25° 21° 18° 15° 10°
2.2 (7.2) 1.9 (6.2) 1.6 (5.2) 1.3 (4.3) 0.9 (3.0)
4.4 (14) 3.7 (12) 3.1 (10) 2.6 (8.5) 1.7 (5.6)
6.7 (22) 5.6 (18) 4.7 (15) 3.9 (13) 2.6 (8.5)
8.9 (29) 7.4 (24) 6.3 (21) 5.3 (17) 3.5 (11)
13
Technical Description
Intrinsically Safe (EEx i)
IS Gnd
Display Panel
Secondary output
DPS
DP+
4-20 mA-
4-20 mA+
4-20 mA HART-
4-20 mA HART+
Primary output
Non Intrinsically Safe (EEx e)
Alternative 2
Secondary output
Alternative 1
Not used
4-20 mA-
4-20 mA+
N/L2/-
Not used
Not used
Non Intrinsically Safe (EEx e)
Power supply
L/L1/+
4-20 mA HART+ /Profibus DP/TRL2 bus
4-20 mA HART- /Profibus DP/TRL2 bus
Primary
output
Pipe installation
Pro gauges with cone antennas can be
mounted in still-pipes. This type of installation
is particularly suitable for applications with
highly turbulent liquids, or liquids with very
low e
r
giving weak radar reflections, such as
LPG. Suitable still-pipe dimensions are 2", 3",
4" and 6". Also 1" pipes can be used in which
case no antenna at all is used. The 1" and 2"
still-pipe gauges are suitable för clean liquids
only and can be delivered complete with still-
pipe, deflection plate and fittings without any
need for welding. Installation can be made in-
side larger stand-pipes.
Used pipes must generally be clean inside,
without irregularities, rust or excessive holes.
Consult Saab or an authorized distributor for
installation advice.
Electrical connections
The Transmitter Head has two separate
junction boxes. One is for a non-intrinsically
safe primary signal output and power supply
cables. The other is normally used for
intrinsically safe (IS) HART/analog outputs or
optionally for a non-IS analog output.
Outputs can be either active or passive
depending on required options. Cables are
twisted and shielded pairs minimum 0.5 mm
2
(AWG 20). Cable entries are ½" NPT for Ex
approved cable glands (CENELEC) or ½" NPT
male conduit fittings (FM/CSA).
For complete installation instructions,
see User’s Guide.
Deflection
plate
14
Technical Description
Specifications
General
Saab TankRadar Pro: Lite, Standard or Gold
10 GHz FMCW radar
See page 12.
Max 1.0 mW.
Integrated reference cable for automatic temperature compensation of radar sweep.
Digital signal processing using FFT, FHAST, MET and Echofixer
1-3 spot elements, PT100 or CU100, or 6 spot elements with common return.
Input accuracy ±0.5°C ( ±0.9°F) .
Display / Configuration
Protection class IP67.
With weather/dirt protection cover.
Graphical LCD display 128 x 64 pixels with 4 control soft-keys and text 7 lines with 16
characters/line for display and configuration
Same as above, mounted in separate enclosure, Protection class IP67
Max cable length, display - radar gauge: 100 m (330 ft)
Cable type: 4 wire shielded instrument cable, min 0.5mm², (AWG 20)
Optional: Temperature measurement 1-3 spot elements PT100 or CU100 (see above)
Rosemount Hand-held communicator RS275.
Rosemount AMS software (in preparation).
Siemens PDM software (in preparation).
ProSetup, Powerful Windows based configuration software.
Electric
100–240 VAC 50/60 Hz or 24–48 VDC
Maximum 10 W
Primary output
(for level, volume etc)
Alt. 1: HART + 4–20 mA current loop (IS option),
Alt. 2: Saab TRL/2 Bus (FSK with Modbus protocol),
Alt. 3: Profibus DP
Secondary output (Optional, for
level, volume, signal quality,
temperature etc.)
Analog 4–20 mA current loop, active or passive.
Optional: IS version.
Type Analog 4–20 mA Current Loop, active (with) or
passive (without loop supply).
Galvanic isolation > 1500 V RMS or DC
Intrinsic safety (Optional) EEx de[ib] IIC T6.
Range 4-20 mA
Alarm level 3.8 mA, 22 mA or freeze; software selectable
Resolution 0.5 µA (0.003%)
Linearity ± 0.01%
Temperature drift ± 50 ppm/°C (± 28 ppm/°F)
Output impedance > 10 M
Voltage compliance 7-30 V (passive output)
External loop resistance < 700 (passive output with 24 V external supply)
< 300 (active output)
Twisted and shielded pair, min. 0.5 mm² (AWG 20)
3 x ½" NPT, for cable glands or conduit entries.
Optional: Cable gland kit, incl 3 x EEx e approved (CENELEC) ½" NPTcable glands.
Optional: 3 x EEx e approved (CENELEC) adapters ½" NPT/M20
Optional equipment, Mounted in separate enclosure
Potential free contacts, Normally open or normally closed, selectable.
Switching capacity: 100-260 VAC 3 A or 24-48 VDC 3 A
Function: Alarm limits and hysteresis set at Radar gauge.
15
Technical Description
Mechanical
Cone, Parabolic, Rod and Process Seal
Cone (PTFE sealing) Antenna Material, alt 1: Stainless Steel 316L, alt 2:
Hastelloy C22, alt 3: Tantalum, alt 4: Monel 400
O-rings: Viton or Kalrez
Sealing: PTFE
Cone (quartz sealing) Antenna Material, alt 1: Stainless Steel 316L, alt 2:
Hastelloy C22, alt 3: Tantalum, alt 4: Monel 400
O-rings: Viton or Kalrez
Sealing: Quartz
Parabolic Stainless Steel 316L, PTFE
Rod PTFE
Process Seal PTFE or AlO
3
(Aluminium oxide)
See pages 6-9
Dimensions See page 12
Material Extended cone antennas available in Stainless steel
316L
Permanent mould cast aluminium, chromed and 120um powder painted.
DIN, ANSI and JIS standard,
Material: Hot-galvanized carbon steel, Fe/Zn Class A 553589.
Optional: Stainless steel flange welded to cone antenna
8 kg (18 lbs)
400 mm (15")
Environment
See diagrams on pages 6-9
-40–70 ºC (-40–158 ºF)
-40-400 ºC (-40–752 ºF)
See pages 6-9
FCC, K8CPRO,
BZT, G750818J
BAKOM, 99.0224.Y.P
IEC 60068-2-3
IEC 68-2-1, IEC 60068-2-52 test KB severity 2
IP66, NEMA 4
IEC 721-3-4 class 4M4
ISO 4892-2
Immunity EN 50081-2, Emission EN50081-1
EN61000-4-5, IEC801-5, level 2 kV
IEC 92 Part 504 sec 3.5
Measuring performance
± 5 mm (± 0.2") or ± 10 mm (± 0.4") depending on model
1mm (0.04")
± 1 mm (± 0.04")
0-99m (0-325')
200mS
Dual processor design, 32-bit DSP, 50 Mflops
Saab's Echofixer and MET Multiple Echo Tracking
CENELEC:
FM:
CSA:
FTZU:
GOST:
SEV:
EEx de [ib] IIC T6
Explosion proof Class I, Div. 1 & 2, Groups A, B, C
and D.
Ex de IIC T6
Ex de ib IIC T6
Ex de ib IIC T4
EEx de [ib] IIC T6
TÜV approval, BPG-US 99/6001
16
Technical Description
Ordering information
RTG 40 G C-0
A
1B P B V
00 0-4
2
0-0
VP
S
Secondary output
None
4-20 mA, active output
4-20 mA, active output, IS (intrinsically safe)
4-20 mA, passive output
4-20 mA, passive output, IS (intrinsically safe)
Antenna information
see pages 17-19
Optional software
Echofixer (only with Lite version)
FHAST (only with Lite or Standard version)
FHAST + Echofixer (only with Lite version)
FHAST + MET (only with Lite or Standard version)
FHAST + MET + Echofixer (only with Lite version)
Display panel
Display panel factory mounted on gauge
Display panel remotely mounted
Display remotely mounted with temp inputs
Special information
None
½" NPT cable gland kit included
FCC approval included
Special information attached to order
Ex certificate
None No Ex approval
Cenelec EEx de [ib] IIC T6, without display
EEx de [ib] IIC T4, including display
FM Class I, Div 1&2 Groups A, B, C, and D
CSA Ex de IIC T6
PTB Zone 0 approval for antenna parts
Primary output
None
4-20 mA HART, active output
4-20 mA HART, active output, IS (intrinsically safe circuit)
4-20 mA HART, passive output
4-20 mA HART, passive output, IS (intrinsically safe circuit)
TRL2 Bus, ModBus Protocol
Profibus DP
Version
GOLD Ex approved, incl. Echofixer, FHAST, MET, ±5mm(0.2") accuracy
STANDARD Ex approved, incl. Echofixer, ±10mm (0.4") accuracy
LITE Non Ex, ±10mm (0.4") accuracy
Power supply
AC 100-240 VAC 50/60 Hz, nominal voltage
DC 24-48 VDC, nominal voltage
Volume calculation
Three pre-configured tank shapes included (vertical and horizontal cylinder plus sphere)
Table of up to 100 points included
Measuring range
0-10 m (0-33 ft)
10-20 m (33-66 ft)
>20 m (>66 ft)
17
Technical Description
Clamped mounting (Low pressure) 5
Cone antenna
Parabolic antenna
Antenna information
Rod and Process Seal antennas,
see page 18
1" and 2" still-pipe antennas,
see page 19
-2-
Tank sealing
PFTE
Quartz
O-ring material
Viton
Kalrez
Flange type (option)
Welded flange, type specified in order
DN100 PN16/JIS150 10K
DN150 PN16/JIS150 10K
DN200 PN16/JIS200 10K
ANSI 3" 300lb
ANSI 4" 150lb
ANSI 6" 150lb
ANSI 8" 150lb
Antenna material
Stainless steel (EN 1.4404) (AISI 316L)
Hastelloy C22 (antenna type 2)
Monel 400 (antenna type 2)
Tantalum (antenna type 2)
Nozzle size
To fit 3" (DN80) nozzles
To fit 4" (DN100) nozzles
To fit 6" (DN150) nozzles
To fit 8" (DN200) nozzles, not antenna type 7
0-
4
0-S
Antenna type
Parabolic antenna
Special
Special information attached to order
None
O-ring material
Viton
Kalrez
Tank sealing
PFTE
Ceramic, AlO
3
Antenna type
Cone antenna with plate and optional flange
Extended cone antenna, standard length 500 mm (20")
Cone antenna with welded flange
Special
None
Length 1000 mm (39") (antenna type 7)
Length 1500 mm (59") (antenna type 7)
Length 2000 mm (79") (antenna type 7)
Special information attached to order
Welded (High pressure) 6
Antenna size
18
Technical Description
Process seal
antenna
Rod antenna
-
1
1-
0P
0
Nozzle size
To fit 2" (DN50) nozzles
To fit 2,5" (DN65) nozzles
Special
Special information attached to order
None
Antenna type
Rod antenna
Flange type
DN50 PN6
DN50 PN10/16/25/40
DN65 PN6
DN65 PN10/16/25/40
ANSI 2" 150lb
ANSI 2" 300/400/600lb
ANSI 2.5" 150lb
ANSI 2.5" 300/400/600lb
-
3
3-
0
0
Nozzle size
To fit 4" (DN100) nozzles
To fit 6" (DN150) nozzles
Antenna type
Process seal antenna
Special
Special information attached to order
None
Flange type
DN100 PN6
DN100 PN10/16
DN100 PN25/40
DN150 PN6
DN150 PN10/16
ANSI 4" 150lb
ANSI 4" 300lb
ANSI 6" 150lb
ANSI 6" 300lb
Tank sealing
PFTE
Ceramic, AlO
3
1" Still-pipe antenna
2" Still-pipe antenna
-2-S
-
5
2-S
56
Antenna material
Stainless steel (EN 1.4404) (AISI 316L)
Flange type (option)
Welded flange, type specified in order
DN100 PN16/JIS150 10K
ANSI 3" 300lb
ANSI 4" 150lb
Nozzle size
To fit 2½" (DN65) nozzles
To fit 2" (DN50) nozzles
To fit 3" (DN80) nozzles
To fit 4" (DN100) nozzles
O-ring material
Viton
Kalrez
Special
None
Special information attached to order
Tank sealing
PFTE
Quartz
Antenna material
Stainless steel (EN 1.4404) (AISI 316L)
Flange type (option)
Welded flange, type specified in order
DN100 PN16/JIS150 10K
DN150 PN16/JIS150 10K
DN200 PN16/JIS200 10K
ANSI 3" 300lb
ANSI 4" 150lb
ANSI 6" 150lb
ANSI 8" 150lb
Nozzle size
To fit 3" (DN80) nozzles
To fit 4" (DN100) nozzles
To fit 6" (DN150) nozzles
To fit 8" (DN200) nozzles
O-ring material
Viton
Kalrez
Special
Excluding still-pipe
Still-pipe length 3 m (9.84")
Still-pipe length 6 m (19.69")
Still-pipe length 9 m (29.53")
Still-pipe length 12 m (39.37")
Special information attached to order
Tank sealing
PFTE
Quartz
Antenna type
1" Still-pipe antenna, max 3 m (9.84")
Antenna type
2" Still-pipe antenna, max 10 m (33 ft)
Technical Description
Saab Tank Control
Box 13045
S-402 51 Göteborg
SWEDEN
Phone: +46 31 337 00 00
Fax: +46 31 25 30 22
Internet: www.saab.tankradar.com
Saab Tank Control Local Representative:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Saab TankRadar Pro Technical Description

Type
Technical Description

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI