Marantec EM 111 Owner's manual

Type
Owner's manual

Marantec EM 111 is an expansion module compatible with Control x.plus control units that extends their functionality. It adds features like door position indication, signal light activation, and remote programming via radio. The module's functions can be customized through programming, allowing for various use cases.

Marantec EM 111 is an expansion module compatible with Control x.plus control units that extends their functionality. It adds features like door position indication, signal light activation, and remote programming via radio. The module's functions can be customized through programming, allowing for various use cases.

Expansion modul EM 111
Typ E20/F20/Jxx
Manual for installation and operation
GB
2 Manual for installation and operation, Expansion module EM 111 GB (#90225)
2. Table of contents
Caution!
Danger of personal injury!
The following safety advice must be
observed at all times so as to avoid
personal injury!
Attention!
Danger of material damage!
The following safety advice must be
observed at all times so as to avoid
material damage!
Advice / Tip
Check
Reference
i
Advice
1. Meaning of symbols . . . . . . . . . .2
2. Table of contents . . . . . . . . . . . .2
3. General safety advice . . . . . . . . .3
4. Product overview . . . . . . . . . . . .5
5. Installation . . . . . . . . . . . . . . . . .5
5.1 Install expansion module . . . . .5
5.2 Wiring of the expansion
module . . . . . . . . . . . . . . . . . .6
6. Programming . . . . . . . . . . . . . . .9
6.1 Functions of the module . . . . .9
6.2 Extended levels of the
Control x.plus control unit . . .10
7. Attachment . . . . . . . . . . . . . . . .11
EC Declaration of Conformity . . . . . . .11
1. Meaning of symbols
Manual for installation and operation, Expansion module EM 111 GB (#90225) 3
3. General safety advice
Target group
This product may only be installed, connected and put into operation by qualified and trained professionals!
Qualified and trained specialist personnel are persons
- who have knowledge of the general and special safety regulations,
- who have knowledge of the relevant electro-technical regulations,
- with training in the use and maintenance of suitable safety equipment,
- who are sufficiently trained and supervised by qualified electricians,
- who are able to recognise the particular hazards involved when working with electricity,
- with knowledge regarding applications of the EN 12635 standard (installation and usage requirements).
Warranty
For an operations and safety warranty, the advice in this instruction manual has to be observed.
Disregarding these warnings may lead to personal injury or material damage. If this advice is disregarded,
the manufacturer will not be liable for damages that might occur.
To avoid installation errors and damage to the device, it is imperative that the installation instructions are
followed. The product may only be operated after reading these installation and operating instructions.
The installation and operating instructions are to be given to the door system user, who must keep them
safe. They contain important advice for operation, checks and maintenance.
This item is produced according to the directives and standards mentioned in the Manufacturer's
Declaration and in the Declaration of Conformity. The product has left the factory in perfect condition with
regard to safety.
Power-operated windows, doors and gates must be checked by an expert (and this must be documented)
before they are put into operation and thereafter as required, but at least once a year.
Correct use
The expansion module expands the Control x.plus control unit.
Beside the advice in these instructions, please observe the general safety and accident
prevention regulations!
Our sales and supply terms and conditions are effective.
Please read carefully!
3. General safety advice
Installation tips
• Ensure that the devices to be connected (doors etc.) are in a mechanically faultless state.
• Before commencing cabling works it is very important to disconnect the system from the electricity supply.
Ensure that the electricity supply remains disconnected throughout the cabling works.
• Adhere to the local protection regulations.
• Lay the electricity supply cables and control cables; these MUST be laid separately.
The operating voltage is 24 V.
Information on cleaning the operator system
Never use water jets, high pressure cleaners, acids or bases for cleaning.
Please read carefully!
4 Manual for installation and operation, Expansion module EM 111 GB (#90225)
Manual for installation and operation, Expansion module EM 111 GB (#90225) 5
5. Installation
Supply package
Dimensions
1 Expansion module
2 Cable harness for module connection
1
4.1 / 1
2
4.1 / 2
126
46
48
4. Product overview
5.1 Install expansion module
• Fit the expansion module (B) in the type 4 /
type 5 (A) expansion housing type.
5.1 / 1
A
B
A
6 Manual for installation and operation, Expansion module EM 111 GB (#90225)
Designation
Type / function
A Operating indicator
B Display for output XH19B
C Display for output XH19A
D
Display for control element
activated
XB59 Control element connections
XB41A
Connection of Control x.plus
control unit
XB41B Connection of further module
XH19A Connection of signalling device
XH19B Connection of signalling device
5.2 Wiring of the expansion
module
5. Installation
5.2.1 Overview of the module connections 5.2.2 Connection of the modules
XB41A
• Connect the Control x.plus control unit to the
connecting socket XB41A.
• Connect another module to socket XB41B as
required.
5.2.2 / 1
5.2.1 / 1
B
D
C
XB59
XB41A
XH19A
XH19B
XB41B
XB41B
Connection of the control unit and a further
module
Manual for installation and operation, Expansion module EM 111 GB (#90225) 7
5. Installation
Advice:
To activate the module, a single
command must be given via the
connection XB59 (impulse to B5-8).
As a result further menus in the
Control x.plus control unit will be ac-
tivated.
Reference:
The activated menus are described in
section 6.2.
i
-XB59
-SB8
13 14
-SB4
13 14
-SB47
13 14
-SB6
13 14
B5 8 4 47 6
5.2.2 / 2
Designation
Type / function
SB8 Operating button for IMPULSE*
SB4
Operating button
intermediate CLOSE position*
SB47 Master button CLOSE
SB6 Operating button for OPEN**
Connection of control element (XB59)
M08E002
* The function sequence is programmable in
level 8 / menu 6 of the Control x.plus control
unit.
** The function “active without stop” is not
modifiable through level 8 / menu 5.
8 Manual for installation and operation, Expansion module EM 111 GB (#90225)
-XH19A
-HH94
H1 92 94
L1
N
Connection for signal light (XH19B)
Connection for signal light (XH19A)
-XH19B
-HH94
H1 92 94
L1
N
5.2.2 / 4
M08E002
Designation
Type / function
HH94 Signal light supplied by custome
XH19A Connection of signalling device
Designation
Type / function
HH94 Signal light supplied by custome
XH19B Connection of signalling device
92
94
H1
5.2.2 / 3
M08E002
92
94
H1
5. Installation
Attention!
To avoid damage being caused to the
circuit board, the contact loading
(max. 230 V / 0.5 A) must be
observed.
Manual for installation and operation, Expansion module EM 111 GB (#90225) 9
6. Programming
6.1 Functions of the module
Function table
Function active inactive
E20 Door in OPEN position ON OFF
F20 Door in CLOSED door position ON OFF
Jxx Signal light Level 3 / Menu 7 Level 3 / Menu 7
Advice:
The module function is printed on the identification plate.
10 Manual for installation and operation, Expansion module EM 111 GB (#90225)
6. Programming
Level 4 – Remote programming
Menu 8: Potential-free contact
LED 7 flashes slowly -> press the hand transmitter button -> LED 7 flashes quickly
Level 5 – Special function
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 4: Lighting duration (in seconds)
OFF 5 10 15 20 25 30 35 40 50 80 100 120 150 180 255
Advice:
Potential-free contact by radio is only available if the module has the identification code LOX
or L1X on the corresponding connection.
Advice:
The lighting duration is only available if the module has the identification code KXX on the
corresponding connection.
6.2 Extended levels of the Control x.plus control unit
An activated module results in the menus which follow in the Control x.plus control unit being activated.
Manual for installation and operation, Expansion module EM 111 GB (#90225) 11
EC Declaration of Conformity
We hereby declare that the product sold by us
and mentioned below corresponds in its design,
construction and version to the relevant and basic
health and safety requirements of the following
EC regulations: EMC Directive, Machinery Directive
and Low Voltage Directive.
Product changes made without our consent will
render this Declaration void.
Product:
Relevant EC Regulations:
- EC EMC Directive
(89/336/EEC),
- Machinery Directive
(98/37/EEC) and
- Low Voltage Directive
(73/23/EEC and 93/68/EEC).
Applied harmonised standards, in particular:
EN 292-1 / EN 61000-6-2 / EN 61000-6-3 /
EN 55014 / EN 61000-3-2 / EN 61000-3-3 /
EN 60335-1 / EN 60335-2-95 / EN 12445 /
EN 12453 / EN 300220-1 / EN 301489-3 /
ETS 300683
Date / Signature
7. Attachment
English Copyright.
No part of this manual may be reproduced without our prior consent.
Subject to changes which are in the interest of technical improvements..
Version: 09.2009
#90225
1 - GB/KD 36-0307 - M - 0.5 - 0909
90225
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Marantec EM 111 Owner's manual

Type
Owner's manual

Marantec EM 111 is an expansion module compatible with Control x.plus control units that extends their functionality. It adds features like door position indication, signal light activation, and remote programming via radio. The module's functions can be customized through programming, allowing for various use cases.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI