DYNACORD PMX-15EC User manual

  • Hello! I am an AI chatbot trained to assist you with the DYNACORD PMX-15EC User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PROMATRIX 6000 Call Stations
PVA‑15CST | PVA‑15ECS
en Operation manual
PROMATRIX 6000 Call
Stations
Table of contents | en 3
DYNACORD 2019.10 | 05 | F01U306897
Table of contents
1
Safety 4
2
Short information 11
3
System overview 12
3.1 Top 12
3.2 Bottom 16
4
Parts included 17
5
Installation 18
5.1 Delivery condition 18
5.2 Button labeling 20
5.3 Retrofit options 21
5.3.1 Alarm button 21
5.3.2 Key switch 23
6
Connection 26
6.1 CST BUS 26
6.1.1 Interface description 26
6.2 LINE port 28
6.3 MIC interface 28
6.4 EXT interface 29
7
Configuration 30
7.1 Main menu 31
7.2 Setup menu 34
8
Operation 36
8.1 Indicators 36
8.2 Functions 40
9
Maintenance 47
10
Technical data 48
10.1 Circuit diagram 52
10.2 Dimensions 53
11
Appendices 54
11.1 Call station extension 54
4 en | Safety
PROMATRIX 6000 Call
Stations
2019.10 | 05 | F01U306897 DYNACORD
1 Safety
Danger!
High risk: This symbol indicates an imminently hazardous
situation such as "Dangerous Voltage" inside the product.
If not avoided, this will result in an electrical shock, serious
bodily injury, or death.
!
Warning!
Medium risk: Indicates a potentially hazardous situation.
If not avoided, this could result in minor or moderate bodily
injury.
!
Caution!
Low risk: Indicates a potentially hazardous situation.
If not avoided, this could result in property damage or risk of
damage to the unit.
1. Read these instructions. – All the safety and operating
instructions should be read before the apparatus or system
is operated.
2. Keep these instructions. – The important safety
instructions and operating instructions should be retained
for future reference.
3. Heed all warnings. – All warnings on the apparatus and in
the operating instructions should be adhered to.
4. Follow all instructions. – All instructions for installation or
use/operating should be followed.
5. Do no use this apparatus near water. – Do not use this
apparatus near water or a moist environment - for example,
near a bath tub, wash bowl, kitchen sink, or laundry tub, in
a wet basement, near a swimming pool, in an unprotected
outdoor installation, or any area which is classified as a wet
location.
PROMATRIX 6000 Call
Stations
Safety | en 5
DYNACORD 2019.10 | 05 | F01U306897
6. Clean only with dry cloth. – Unplug the apparatus from the
outlet before cleaning. Do not use liquid cleaners or aerosol
cleaners.
7. Do not block any ventilation openings. Install in
accordance with the manufacturer’s instructions. –
Openings in the enclosure, if any, are provided for
ventilation and to ensure reliable operation of the
apparatus and to protect it from overheating. These
openings must not be blocked or covered. This apparatus
should not be placed in a built-in installation unless proper
ventilation is provided or the manufacturer’s instructions
have been adhered to.
8. Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including
amplifiers) that produce heat or in direct sunlight.
9. No naked flame sources, such as lighted candles, should
be placed on the apparatus.
10. Do not defeat the safety purpose of the polarized or
ground-type plug. – A polarized plug has two blades with
one wider than the other. A grounding type plug has two
blades and a third grounding prong. The wider blade or the
third prong are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
11. Protect the power cord from being walked on or pinched
particularly at plug, convenience receptacles, and the
point where they exit from the apparatus.
12. Only use attachments/accessories specified by the
manufacturer. – Any mounting of the apparatus should
follow the manufacturer’s instructions, and should use a
mounting accessory recommended by the manufacturer.
13. Use only with the cart, stand, tripod, bracket or table
specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/
6 en | Safety
PROMATRIX 6000 Call
Stations
2019.10 | 05 | F01U306897 DYNACORD
apparatus combination to avoid injury from tip-over. Quick
stops, excessive force, and uneven surfaces may cause the
appliance and cart combination to overturn.
14. Unplug this apparatus during lighting storms or when
unused for long periods of time. – Not applicable when
special functions are to be maintained, such as evacuation
systems.
15. Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into
the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
16. The apparatus shall not be exposed to dripping or
splashing and that no objects filled with liquid, such as
vases, shall be placed on the apparatus.
17. Batteries (battery pack or batteries installed) shall not be
exposed to excessive heat such as sunshine, fire or the
like.
!
Caution!
Danger of explosion if battery is incorrectly replaced. Replace
only with the same or equivalent type. Dispose of used
batteries according to the environmental law and procedures.
18. Professional installation only – Do not use this equipment
in residential applications.
19. Condensation – In order to avoid condensation; wait a few
hours before turning on the equipment when it is
transported from a cold to a warm space.
20. Hearing damage – For apparatus with audio output, to
prevent possible hearing damage, do not listen at high
volume levels for long periods.
21. Replacement parts – When replacement parts are required,
be sure the service technician has used replacement parts
specified by the manufacturer or having the same
PROMATRIX 6000 Call
Stations
Safety | en 7
DYNACORD 2019.10 | 05 | F01U306897
characteristics as the original part. Unauthorized
substitutions may result in fire, electric shock or other
hazards.
22. Safety check – Upon completion of any service or repairs
to this apparatus, ask the service technician to perform
safety checks to determine that the apparatus is in proper
operating condition.
Danger!
Overloading – Do not overload outlets and extension cords as
this can result in a risk of fire or electric shock.
23. Power sources – This apparatus should be operated only
from the type of power source indicated on the marking
label. If you are not sure of the type of power supply you
plan to use, consult your appliance dealer or local power
company. For apparatuses intended to operate from battery
power, or other sources, refer to the operating instructions.
24. Power lines – An outdoor system should not be located in
the vicinity of overhead power lines or other electric light or
power circuits, or where it can fall into such power lines or
circuits. When installing an outdoor system, extreme care
should be taken to keep from touching such power lines or
circuits, as contact with them might be fatal. U.S.A. models
only – refer to the National Electrical Code Article 820
regarding installation of CATV systems.
Danger!
Object and Liquid entry – Never push objects of any kind into
this apparatus through openings as they may touch dangerous
voltage points or short-out parts that could result in a fire or
electric shock. Never spill liquid of any kind on the apparatus.
25. Coax grounding – If an outside cable system is connected
to the apparatus, be sure the cable system is grounded.
U.S.A. models only: Section 810 of the National Electrical
8 en | Safety
PROMATRIX 6000 Call
Stations
2019.10 | 05 | F01U306897 DYNACORD
Code, ANSI/NFPA No.70-1981, provides information with
respect to proper grounding of the mount and supporting
structure, grounding of the coax to a discharge apparatus,
size of grounding conductors, location of discharge unit,
connection to grounding electrodes, and requirements for
the grounding electrode.
26. Protective grounding – An apparatus with class I
construction shall be connected to a power outlet socket
with a protective grounding connection.
Protective earthing – An apparatus with class I
construction shall be connected to a mains socket outlet
with a protective earthing connection.
Note for power connections
For permanently connected equipment, a readily operable
mains plug or all-pole mains switch shall be external to the
equipment and in accordance with all applicable
installation rules.
For pluggable equipment, the socket-outlet shall be
installed near the equipment and shall be easily accessible.
This label may appear on the bottom of the apparatus due to
space limitations.
!
Caution!
To reduce the risk of electrical shock, DO NOT open covers.
Refer servicing to qualified service personnel only.
PROMATRIX 6000 Call
Stations
Safety | en 9
DYNACORD 2019.10 | 05 | F01U306897
!
Warning!
To prevent fire or shock hazard, do not expose units to rain or
moisture.
!
Warning!
Installation should be performed by qualified service personnel
only in accordance with the National Electrical Code or
applicable local codes.
!
Warning!
Power disconnect: If the apparatus is mains powered and a
power supply cord set is provided, the disconnect device is the
mains plug of the power cord set.
If an AC‑DC adapter is provided and the mains plug that is part
of the direct plug‑in device, the AC‑DC adapter is the
disconnect device.
The socket outlet shall be near the apparatus and shall be
easily accessible.
!
Warning!
To avoid electric shock, do not connect safety extra-low voltage
(SELV) circuits to telephone-network voltage (TNV) circuits.
LAN ports contain SELV circuits, and WAN ports contain TNV
circuits. Some LAN and WAN ports both use RJ‑45 connectors.
Use caution when connecting cables.
Old electrical and electronic appliances
Electrical or electronic devices that are no longer serviceable
must be collected separately and sent for environmentally
compatible recycling (in accordance with the European Waste
Electrical and Electronic Equipment Directive).
To dispose of old electrical or electronic devices, you should use
the return and collection systems put in place in the country
concerned.
10 en | Safety
PROMATRIX 6000 Call
Stations
2019.10 | 05 | F01U306897 DYNACORD
Only used at
altitude not
exceeding 2000m.
Only used in non-
tropical climate
regions.
PROMATRIX 6000 Call
Stations
Short information | en 11
DYNACORD 2019.10 | 05 | F01U306897
2 Short information
The PMX-15CST and PMX-15ECS are call stations for the
PROMATRIX 6000 system:
The PMX-15CST call station is delivered without key
switches or alarm buttons, but these optional components
can be built in as described in Retrofit options, page 21.
The PMX-15ECS call station has a factory-fitted key switch
and two alarm buttons.
Both call stations have a gooseneck microphone with pop shield
and permanent monitoring, a total of 20 buttons, an illuminated
LC display, and an integrated loudspeaker.
The call stations can be extended to suit the user’s
requirements by connecting up to five PMX-20CSE call station
extensions, each with 20 customizable selection buttons.
Other properties:
Five menu/function keys (pre-programmed) - one green or
one yellow indicator light per button
15 selection buttons (customizable) - two indicator lights
(green/red) per button
Numeric zone selection (can be activated during IRIS-Net
configuration)
Label with transparent covering - the label can be changed
at any time
Can be used as a standing or desk/rack flush-mounted
device
Internal monitoring with error logging - complies with all
relevant national and international standards
Easy configuration - use of the Configuration Wizard or IRIS-
Net software
12 en | System overview
PROMATRIX 6000 Call
Stations
2019.10 | 05 | F01U306897 DYNACORD
3 System overview
3.1 Top
See the table on the following pages for an explanation of the
numbers in the top view figures.
Figure3.1: Top view PMX-15CST call station
PROMATRIX 6000 Call
Stations
System overview | en 13
DYNACORD 2019.10 | 05 | F01U306897
Figure3.2: Top view PMX-15ECS call station
14 en | System overview
PROMATRIX 6000 Call
Stations
2019.10 | 05 | F01U306897 DYNACORD
Nr. Icon Element Description (default
configuration)
1 Selection buttons/
numeric keypad
User programmable zone/
group selection buttons with
two indicator lights.
2 Area for key
switch and alarm
buttons:
The key
switch
prevents
unauthorized
use of the call
station.
The alarm
buttons are
used to
broadcast an
alarm signal.
They have a
transparent
cover to
prevent
unintentional
actuation.
PMX-15CST call station:
has provision for
installing an optional
key switch and alarm
buttons.
PMX-15ECS call station:
is factory-fitted with a
key switch and two
alarm buttons.
3 Voice alarm
indicator light
Illuminates red if the system
is in the voice alarm
condition state.
4 Combined fault
warning indicator
light
Illuminates yellow if a fault
occurs.
5 Power indicator
light
Illuminates green if the
power supply is on.
PROMATRIX 6000 Call
Stations
System overview | en 15
DYNACORD 2019.10 | 05 | F01U306897
Nr. Icon Element Description (default
configuration)
6 Microphone Monitored goose neck
microphone.
7 Loudspeaker Audible fault or VAC
warning.
8 Display Status/error displays for the
call station or the entire
system.
9 ESC button Acknowledges and advances
to next error message, with
indicator light.
10 button Switches the system on/off
(standby), with indicator
light.
11 DEL button - (no default configuration).
12 button Stops a live audio signal,
with indicator light.
13 button For announcements to
selected zones, with
indicator light.
See also
Retrofit options, page 21
16 en | System overview
PROMATRIX 6000 Call
Stations
2019.10 | 05 | F01U306897 DYNACORD
3.2 Bottom
21 3 4
Figure3.3: Bottom view PMX-15CST and PMX-15ECS call stations
Nr. Element Description
1 EXT OUT
port
Connection for call station extension
2 CST BUS
port
Connection to controller
3 LINE port Connection for external audio devices or a
PTT button
4 MIC port Connection for external microphone
PROMATRIX 6000 Call
Stations
Parts included | en 17
DYNACORD 2019.10 | 05 | F01U306897
4 Parts included
Quantity Component
1 PMX-15CST or PMX-15ECS call station
1 Patch cable (3 meters)
7 Blank paper strips
1 Strain relief (bracket)
2 Screws for strain relief
1 Cover release tool
1 Operation manual
1 Important safety instructions
Warranty
For information regarding the warranty, see www.dynacord.com
18 en | Installation
PROMATRIX 6000 Call
Stations
2019.10 | 05 | F01U306897 DYNACORD
5 Installation
5.1 Delivery condition
The call stations are programmed with the following factory
functions and properties settings:
Parameters Setting/description
CAN address 0 (disconnected)
CAN baud rate 10 kbit/s
CAN termination off
Name PMX-15CST / PMX-15ECS
Password Setup menu password-protected,
password: 2222
Prechime Off
Buzzer On (acoustic warning signal)
Compressor Off
Options Alarm buttons Not configured
Key switch Not configured
External
microphone
Not configured
Button
assignme
nt
Selection
buttons 1-n
Selection of zone 1 through n
(button 1 = zone 1, button 2 =
zone 2 etc.)
Call in selected zones/groups,
default priority 50
Switches system on/off, default
priority 40
Stops an active audio signal,
default priority 69
PROMATRIX 6000 Call
Stations
Installation | en 19
DYNACORD 2019.10 | 05 | F01U306897
Parameters Setting/description
ESC Acknowledges and advances to
next error message
DEL - (no default configuration)
Special functions Not configured
!
Warning!
If several call stations need to operate with a single controller,
each call station must be assigned a unique CAN address
(1-16). Subsequently, if the CAN address changes, the
configuration has to be changed as well.
20 en | Installation
PROMATRIX 6000 Call
Stations
2019.10 | 05 | F01U306897 DYNACORD
5.2 Button labeling
The call station buttons are labeled using labeling strips, which
are inserted from above. Execute following steps to label the
buttons:
1. Carefully loosen the transparent cover on the top using the
included release tool. A provision for releasing the cover is
made at the top of the cover on the right side of the
microphone.
2. Insert the release tool into the provision for release and
move the tool to the right side.
3. The top snaps will release from the housing.
4. Insert the tool at the left side of the microphone and move
to the left.
5. Now the cover can be removed.
6. Insert the labeled paper strips into the label fields.
7. Reattach the transparent cover: Align the bottom cover
snaps with the holes in the call station housing, then push
the top cover snaps gently and equally into the holes.
/