10
HARD MAX
P14 AIR TEMP °C -20 15 -15
P15 Chill Time MINUTES 5 480 90
P16 CHILL TEMP °C -15 15 3
P17 HOLD TEMP °C -15 15 3
SHOCK FREEZE
P18 AIR TEMP °C -35 15 -30
P19 CHILL TIME MINUTES 5 480 240
P20 CHILL TEMP °C -35 15 -21
P21 HOLD TEMP °C -35 15 -21
PROFFESSIONAL 1
P22 Air Temp. Std. °C -20 15 -15
P23 Chill Time Std. Minutes P24 P25 90
P24 Chill Time Minimum Minutes 5 60 5
P25 Chill Time Maximum Minutes 60 480 240
P26 Chill Temp. Std. °C P27 P28 3
P27 Chill Temp. Minimum °C -20 -5 -10
P28 Chill Temp. Maximum °C -5 15 5
P29 Hold Temp. Std. °C P30 P31 3
P30 Hold Temp. Minimum °C -10 0 0
P31 Hold Temp. Maximum °C 0 10 10
P32 Change Time % 5 95 80
P33 Change Temp. % 5 95 80
PROFFESSIONAL 2
P34 Air Temp. Std. °C -20 15 -15
P35 Chill Time Std. Minutes P36 P37 90
P36 Chill Time Minimum Minutes 5 60 5
P37 Chill Time Maximum Minutes 60 480 240
P38 Chill Temp. Std °C P39 P40 3
P39 Chill Temp. Minimum °C -20 -5 -10
P40 Chill temp. Maximum °C -5 15 5
P41 Hold Temp. Std. °C P42 P43 3
P42 Hold Temp. Minimum °C -10 0 0
P43 Hold Temp. Maximum °C 0 10 10
P44 Change Time % 5 95 80
P45 Change Temp. % 5 95 80
PROFESSIONAL 3
P46 Air Temp. Std. °C -20 15 -15
P47 Chill Time Std. Minutes P48 P49 90
P48 Chill Time Minimum Minutes 5 60 5
P49 Chill Time Maximum Minutes 60 480 240
P50 Chill Temp. Std. °C P51 P52 3
P51 Chill Temp. Minimum °C -20 -5 -10
P52 Chill Temp. Maximum °C -5 15 5
P53 Hold Temp. Std. °C P54 P55 3
P54 Hold Temp. Minimum °C -10 0 0
P55 Hold Temp. Maximum °C 0 10 10
P56 Change Time % 5 95 80
P57 Change Temp. % 5 95 80
SYSTEM
P58 UV Light Enable Minutes 0 120 0
P59 HACCP Enable Function NO YES NO
P60 Shock Chill Temp. Function NO YES NO
P61 Chill Hysteresis °K 2 20 4
P62 Hold Hysteresis °K 2 20 4
P63 APM Time Minutes 0 30 2
P64 APM Differential °K 0 20 10
P65 FAN 1 Hold Operation Function OFF/ CYCLE/ AUTO/ ON AUTO
P66 FAN 2 Hold Operation Function OFF/ CYCLE/ AUTO/ ON AUTO
P67 Capacity Enable Function OFF/ AUTO/ ON ON
P68 Capacity Hysteresis °K 2 20 5
P69 Defrost Type Function OFF/ ELE/ GAS OFF
P70 Smart Defrost Inc Integer 0 240 30
P71 Defrost End Time Minutes 1 60 20
P72 Defrost End Temp. °C 0 50 20
P73 Drain Time. Minutes 0 30 1
P74 Fan Delay Temp. °C -15 15 5
P75 Duty Cycle % 0 100 60
P76 Comp. Rest Time Minutes 0 30 3
P77 HP Switch Function NO YES YES
P78 Door Switch 2 Function NO YES NO
P79 Door Switch 1 Function NO YES YES
P80 Door Stop Minutes 0 30 1
P81 Door Alarm Delay Minutes 0 30 5
P82 High Alarm Temp. °K 0 50 10
P83 High Alarm Delay Minutes 0 120 30
P84 Alarm Time Minutes 0 120 1
P85 Alarm Repeat Interval Minutes 0 480 0