Star Manufacturing International, 10 Sunnen Drive, St. Louis, MO 63143
Part Number 2M-60902-30 (800) 807-9054 March 20007
INSTALLATION INSTRUCTIONS
ECOH/EHS 208/240VAC CORD KIT
Part Number 9Q-ECOH-CK
Inspect Kit and confirm that the following items are provided:
1 7 Foot 10/4 S. O. Cord with 15-30P Cord Cap (attached)
1 15-30R Receptacle
1 Strain Relief Cord Connector,
1 Stainless Steel Receptacle Cover
1 Conduit Lock Nut 3/4”
WALL
Install 15-30R receptacle into wall junction box per standard electrical and safety practices.
Install stainless steel receptacle cover on junction box.
OVEN
Looking at the right side of the oven, locate the rectangular inspection panel and remove this
panel. Locate the three pole terminal block and ground wire connector inside this side, attached
to the base of the oven. (Terminal block is very close to the right side of the oven.) The cord
wires will connect at this point.
Looking at the back of the oven, locate the round access hole in the lower left corner. Insert the
pre-assembled cord end with strain relief in this access. Tighten the strain relief lock-nut to
secure.
Connect S. O. Cord conductors to the white oven wires as follows:
(BLACK) (L1 Terminal)
(RED) (L2 Terminal)
(BLUE) (L3 Terminal)
(GREEN) Chassis Ground Lug
There are 6 white wires connected to the terminal block numbered 1, 2, 3, 4, 5, and 6.
Verify the wires are connected as follows:
Two wires should be connected to each terminal. (L1, L2 and L3.)
Wires 1 & 4 together, Wires 2 & 5 together and Wires 3 & 6 together. Each set of two
connected to one of the terminal blocks. (Does not matter which set goes to what terminal.)
Adjust S. O. Cord length to allow approximately 6 feet of cord between Strain Relief compression
nut and the Cord Cap. Tighten the Strain Relief compression nut to secure the S. O. Cord.
Insert Cord Cap into receptacle, energize supply circuit breaker if de-energized.
Energize oven and check for proper operation.
After verifying that operation is correct, re-install inspection panel.
/