SIIG B5350 User manual

Type
User manual

This manual is also suitable for

Transport GX21
B5350
Users Manual
WARNING!
This product should be serviced only by qualified service
engineers. Do not remove the chassis cover or attempt to
service this product unless you are qualified to do so. Once
the chassis cover is removed, there is a risk of electric
shock that could lead to serious injury or death.
Preface
Copyright
This publication, including all photographs, illustrations, and soft-
ware, is protected under international copyright laws, with all rights
reserved. Neither this manual, nor any material contained herein,
may be reproduced without written consent of the manufacturer-.
Copyright 2003-4
Version 1.00
Disclaimer
Information contained in this document is furnished by TYAN com-
puter Corporation and has been reviewed for accuracy and reliability
prior to printing. TYAN assumes no liability whatsoever, and dis-
claims any express or implied warranty, relating to sale and/or use of
TYAN products including liability or warranties relating to fitness for
a particular purpose or merchantability. TYAN retains the right to
make changes to product descriptions and/or specifications at any
time, without notice. In no event will TYAN be held liable for any
direct or indirect, incidental or consequential damage, loss of use,
loss of data or other malady resulting from errors or inaccuracies of
information contained in this document.
Trademark recognition
All registered and unregistered trademarks and company names
contained in this manual are property of their respective owners
including, but not limited to the following.
TYAN, TYAN Tiger i7501R (5350), and Transport GX21 are trade-
marks of TYAN Computer Corporation.
Intel, Xeon, and combinations thereof are trademarks of Intel Corpo-
ration.
Phoenix, PhoenixBIOS, and combinations thereof are trademarks of
Phoenix Technologies Ltd.
Microsoft Windows is a trademark of Microsoft Corporation.
IBM, PC, AT and PS/2 are trademarks of IBM Corporation.
Winbond is a trademark of Winbond Electronics Corporation.
Portable Document Format (PDF) is a trademark of Adobe Corpora-
tion.
ii
Federal Communications Commission
Notice for the USA Compliance Information State-
ment (Declaration of Conformity Procedure) DoC
FCC Part 15: This device complies with part 15 of the
FCC Rules
Operation is subject to the following conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received including inter-
ference that may cause undesired operation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the
receiver.
Plug the equipment into an outlet on a circuit different from
that of the receiver.
Consult the dealer on an experienced radio/television technician for
help.
Notice for Canada
This apparatus complies with the Class B limits for radio interference
as specified in the Canadian Department of Communications Radio
Interference Regulations. (Cet appareil est conforme aux norms de
Classe B d’interference radio tel que specifie par le Ministere Cana-
dien des Communications dans les reglements d’ineteference
radio.)
Notice for Europe (CE Mark) This product is in conformity
with the Council Directive 89/336/EEC, 92/31/EEC
(EMC).
CAUTION: Lithium battery included with this board. Do not puncture,
mutilate, or dispose of battery in fire. Danger of explosion if battery
is incorrectly replaced. Replace only with the same or equivalent
type recommended by manufacturer. Dispose of used battery
according to manufacturer instructions and in accordance with your
local regulations.
iii
About this manual
This manual provides you with instructions on installing your Trans-
port GX21 (B5350), and consists of the following sections
Chapter 1:
Provides an introduction to the Transport GX21 (B5350) bare bones,
packing list, describes the external components, gives tables of key
components, and provides block diagrams of the system.
Chapter 2:
Covers procedures on installing the CPUs, memory modules,
optional PCI card, and hard drives.
Chapter 3:
Covers removal and replacement procedures for pre-installed com-
ponents.
Appendix:
Provides detailed specifications, maintenance and troubleshooting
procedures, an explanation of BIOS and technical diagrams.
iv
Safety information
Before installing and using the Transport GX21 , take note of the fol-
lowing precautions:
Read all instructions carefully.
Do not place the unit on an unstable surface, cart or stand.
Do not block the slots or openings on the unit which are
provided for ventilation.
Only use the power source indicated on the marking label.
If you are not sure, contact the power company.
The unit uses a three-wire grounded cable, which is sup-
plied with a third pin to ground the unit and prevent electric
shock. Do not defeat the purpose of this pin. If your outlet
does not support this type of plug, contact an electrician to
replace the obsolete outlet.
Do not place anything on the power cord. Place the power
cord where it will not be stepped on.
Follow all warnings and cautions in this manual and on the
unit case.
Do not push objects in the ventilation slots as they may
touch high voltage components and result in shock and
damage to the components.
When replacing parts, ensure that you use parts specified
by the manufacturer.
When service or repairs have been carried out, perform
routine safety checks to verify that the system is operating
correctly.
Avoid using the system near water, in direct sunlight, or
near a heating device.
Cover the unit when not in use.
Contents
Overview
About the Transport GX21 (B5350) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Product models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
B5350G21S2H specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Box contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Opening the box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
About the product. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
System front view and front panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
System rear view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
System internal views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Setting up
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Work area. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Installing motherboard components. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Removing the chassis cover. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installing CPUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Installing memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installing a PCI card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Installing a hard drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Installing an external S-ATA hard drive . . . . . . . . . . . . . . . . . . . . . . 20
Rack mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Replacing installed components
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Replacing motherboard components . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Disconnecting all motherboard cables. . . . . . . . . . . . . . . . . . . . . . . . 27
Replacing the motherboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Replacing the CD-ROM drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Replacing the LED control board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Replacing the storage backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Replacing the power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Replacing the cooling fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Appendix
BIOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Technical support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
1.1 About the Transport GX21 (B5350)
Chapter 1: Overview 1
Chapter 1: Overview
1.1 About the Transport GX21 (B5350)
Congratulations on your purchase of the Transport GX21
(B5350), rack mountable, barebone system for Intel® Xeon™
processor. The Transport GX21 (B5350) uses an advanced
Intel chipset for optimum performance and reliability. The
add-on S-ATA storage controller provides great flexibility and
is combined with Gigabit Ethernet ports to provide powerful
computing capacity and optimal I/O bandwidth for the most
demanding of enterprises.
The rugged, industry standard 19-inch, rack mountable
design contains up to 2 HDD bays, 1 slim CD-ROM bay
option, making it both flexible and practical.
1.2 Product models
Model HDD
Hot Swap
Support
HDD
Back-
plane
SKU Type
B5350G21S2H 2 removable
HDD bays
Yes 2 port S-
ATA
Standard SKU
1.3 Features
2 Chapter 1: Overview
1.3 Features
1.3.1 B5350G21S2H specifications
Enclosure
Industry standard, 19” rack mount-
able, 1U chassis
2 hot swappable HDDs
1 slim CD-ROM bay
21.5 x 17 x 1.73 inch (546 x 432 x 44
mm)
Storage
Dual channel IDE (CD-ROM)
Integrated Serial ATA (6300ESB),
support for 2 SATA ports, RAID 0,1
Support for up to 2 hot-swappable
SATA 1.0 HDD
Processors
Dual mPGA604pin ZIF sockets
Single or dual Intel® Xeon™
(Nacona) processor
800 MHz FSB
Cooling
4 cooling fans (40 x 40 x 56 mm)
1 cooling fans (40 x 40 x 28 mm)
2 passive CPU heatsinks
Chipset
Intel® Lindhurst-VS (E7320) MCH
Intel Hance Rapids (6300ESB)
Southbridge
SMSC DME1737 LPC I/O chip
Analog Devices ADM1027 hardware
monitoring IC
Motherboard
Tyan Tiger i7510 S5350 mother-
board
ATX form factor
Phoenix BIOS on 8 Mb LPC flash
ROM
Memory
Dual channels, (8) DIMM sockets
Support for up to (6) DDR333 or (8)
DDR266
Up to 16 GB of registered DDR
Support for ECC type memory mod-
ules
Networking
2 Gigabit Ethernet ports (Broadcom
BCM5721PCI-E GbE LAN control-
ler connected MCH), with teaming
feature support
Expansion slots
(1) 64-bit, 66 MHz PCI-X slot on
riser card
Power supply
EPS 12V, 1U, 500W with PFC
Back I/O ports
Stacked PS/2 mouse and keyboard
ports
2 USB 2.0 ports
1 9-pin UART serial port
2 RJ-45 LAN ports
1 VGA port
Video
ATI® Rage™ XL PCI Graphics con-
troller
8 MB frame buffer video memory
Front panel
2 USB 2.0 ports
HDD activity, Warning/Fail, LAN
activity, and power LEDs
Power and reset switches
Regulatory
FCC class B (declaration of
conformity)
CE (declaration of conformity)
1.3 Features
Chapter 1: Overview 3
1.3.2 Box contents
Diagram Component
1U chassis, 2 external HDD bays
Tyan S5350 system board (pre-
installed)
Slim CD-ROM adapter
24x slim CD-ROM drive (pre-
installed)
Slim FDD adapter
S-ATA backplane and holding
bracket (pre-installed)
LED control board (pre-installed)
64-bit riser card (pre-installed)
EPS 12V 500W PSU (pre-installed)
15,500 rpm cooling fan (4 pcs -
40 x 40 x 56 mm)
15,000 rpm cooling fan (1 pcs -
40 x 40 x 28 mm)
Fan holding bar
40
41
1
J4
J3
J1
2
1
39
CORER1.PCB MADE TAIWAN
40 94V-0
41
1
J4
J3
J1
2
1
39
1.3 Features
4 Chapter 1: Overview
1.3.3 Accessories
Power cords (US/German)
2 x CPU heatsinks
P/N 343734800001
2 x S-ATA cables, motherboard to
backplane
2 x Sliding rails
P/N 341730200001
2 x mounting ears
1 x 40 pin IDE cable for CD-ROM
(B5350G21S2H only)
S-ATA power riser cable
Tyan and Intel 6300 ESB S-ATA
RAID driver disk and CD
Motherboard quick reference guide
and user’s manual
Transport GX21 (B5350) hardware
installation guide
h
ttp://w
w
w
.t
y
a
n
.c
o
m
B5350G21S2H
B5350
GX21
High Performance Motherboard
User's Manual
FDD J37 LPT1
1
1
CPU
1
1
1
1
1
1
1
1
1
11
11
1
111
CPU
J16 Force 400MHz FSB instead
of 533MHz FSB Header
Close: Force 400 MHz FSB
(4x 100MHz)
Open: 533MHz FSB
(4x 133MHz)
J21 PCI-X A (PCI1) Speed
1-2 Close: 100MHz
2-3 Close: 133MHz (Default)
J22 10/100 Ethernet LAN1 LED
(82551) Header
Pin1: Yellow+
Pin2: Yellow-
Pin3: Green+; Pin4: Green-
J23 Gigabit Ethernet LAN2 (J15)
LED Header
Pin1: Yellow+
Pin2: Yellow-
Pin3: Green+; Pin4: Green-
J24 Gigabit Ethernet LAN3 (J14)
LED Header
Pin1: Yellow+
Pin2: Yellow-
Pin3: Green+; Pin4: Green-
J25 Buzzer (System Speaker)
Pin1: Vcc, Pin2 & 3: NC
Pin4: Speak
J26 SO-DIMM (Compatible with
Tyan M7902 SCSI RAID Card)
J29 SMDC (System Management
Daughter Card) Connector
J31 Hard Disk Activity LED
External Input
J33 CMOS Clear
Pin 1-2 Close: Normal (Default)
Pin 2-3 Close: Clear CMOS
J34 Front USB Header (USB2)
(via an optional cable)
J36 COM2 port (via a cable)
J43 PCI-X B (PC12) Speed
1-2 Close: 100MHz (Default)
2-3 Close: 133MHz
18
17
2
1
J39 Front Panel Connector
1
3
5
7
9
11
13
15
2 4 6 8 10 1214 16 18
17
PWR_LED PWRER SLEEP INTRU
PWR_LED+
PWR_LED+
HD_LED-
HD_LED+
PWR+
GND
SLEEP+
GND
NC
NC
INTRU-
INTRU+
IRTX
GND
GND
IRRX
+5V
RESET+
HD-LED RESET INFRARED INTRU
FAN1
FAN4
FAN2 / FAN3 / FAN5 / FAN6 /
FAN7 / FAN8 / FAN9
CPU1_FAN
CPU2_FAN
Chassis FAN
J26 SO_DIMM
PCI1
PCI2
Intel
82551
J43
J21
1
J36
J32
FAN6
COM2
PCI4
PCI3
J31
1
Intel
E7501
Intel
ICH5R
Winbond
W83627HF
P64H2
ATI
RAGE XL
Intel
82546EB
J15
LAN2
J14
LAN3
J11
(VGA)
J7
(COM1)
J4
KB / MS
J4J3
KB(Bottom)
Mouse(Top)
USB (Bottom)
LAN1 (Top) Optional
J5
USB1
BT1
CPU
CPU2
DIMMA_DIMM3
DIMMA_DIMM2
DIMMA_DIMM1
DIMMB_DIMM3
DIMMB_DIMM3
DIMMB_DIMM1
CPU1
S2735
SATA2
SATA1
MMOS J33
FAN2
FAN8
FAN7
USB2
J34
J39
BIOS
FRONT PANEL
SEC-IDE J13
SMDC J29
J24
J23
J25
JP1
J16
J22
FAN9
FAN5
FAN4
CPU2_FAN
PRI-IDE J15
FAN3
FAN1
CPU1_FAN
Power Supply
The Tiger i7501R S2735 is EPS12V
compatible.
2 power connectors: EPS12V
(24-pin) + EPS12V (8-pin)
power connectors
Check User's Manual for details
OSE P/N:12-0012-355C
http://www.TYAN.COM #D1562-100 Rev.1.00
Tiger i7501R S2735 Board Parts and Jumpers
1U 2-Way Server Platform
B2880T1S
Transport GX28
ID : 1540 - 100
Revision 1.0
Hardware
Installation Guide
1.3 Features
Chapter 1: Overview 5
1.3.4 Opening the box
Open the box carefully and ensure that all components are
present and undamaged. The product should arrive pack-
aged as illustrated below.
htt
p
:
/
/
w
w
w
.
t
ya
n
.
c
o
m
h
t
t
p
://ww
w
.tya
n
.com
Box contents as packaged
Accessory pack Accessories as packaged
1.4 About the product
6 Chapter 1: Overview
1.4 About the product
1.4.1 System front view and front panel
1.4.2 System rear view
Power supply status
A single bi-colored LED indicating power supply status as described below.
LED Power Supply Condition
Off No AC power to all power supplies
Amber Power supply critical event causing a shutdown; failure, OCP,
OVP, Fan Fail.
Blinking
Amber
Power supply warning events where the power supply continues
to operate: high temp, high power, high current, slow fan.
Blinking
Green
AC present/Only 5VSB on (PS off)
Green Output ON and OK
disc
Power indicator
Power switch
USB ports
LAN activity
indicator
Reset switch
HDD1/HDD2
activity
Warning
HDD activity
indicator
EPS 12V 500W PSU
Stacked PS/2 mouse and keyboard ports
VGA port
RJ-45 LAN ports
Serial port (COM 1)
USB ports
PCI Expansion slot
Power Supply Status
1.4 About the product
Chapter 1: Overview 7
1.4.3 System internal views
1 Floppy disk drive bay 8 FDD connector
2 LED control board 9 Power connector (located
underneath the cabling)
3 Slim CD-ROM drive 10 Memory slots
4 Fan bracket 11 EPS 12V 500W power supply
5 IDE connector (located under-
neath the fan bracket)
12 Processor sockets
6 Fan connectors 13 1-port S-ATA backplane
board x 2pcs
7 Riser card 14 Front panel cables
7
6
12 3
4
5
6
8
9
6
10
11
12
6
13
14
1.4 About the product
8 Chapter 1: Overview
Block diagram
PRINTER
HEADER
SERIAL
HEADER
SERIAL
PORT
KBD
PORT
FLOPPY
CONN
SUPER-I/O
DME 1737
Hance Rapids
LINDENHURST
VS
MCH
NOCONA
NOCONA
ADM1027
BIOS
8Mb
ATI
RAGE XL
BCM5721 GLAN
BCM5721 GLAN
CPU1 VRD
CPU0 VRD
2.5V VRD
DDR PWR
1.25V VRD
DDR TERM
SO-DIMM 200
CK409B
CLOCK
SYNTH
DRVR
DB800
BUFFER
FANx
CPU_FAN1
CPU_FAN2
CHASSIS_FAN
LPC BUS
LPC BUS
PCI 32/33MHz
8MB DISPLAY
MEMORY
CRT CONN
PCI 32/33MHz SLOTs
PCI-X SLOT
DDR 266/333 ECC REGISTERED DIMMs A
DDR 266/333 ECC REGISTERED DIMMs B
MEM CNTRL AND DATA
MEM CNTRL AND DATA
HOST BUS 800
PCI-EX 1
PCI-EX 1
PRIMARY
IDE CONN
SECONDARY
IDE CONN
SATA
CONNx2
USB REAR
CONNx2
USB FRONT
CONNx2
HI 1.5
SERVER
MGMT
CONN
FIRMWARE
HUB
2.1 Before you begin
Chapter 2: Setting up 9
Chapter 2: Setting up
2.1 Before you begin
This chapter explains how to install motherboard components
including CPUs, memory modules, and PCI cards. There are
also instructions in this section for installing S-ATA and IDE
hard drives.
Careful attention should be given to the precautions men-
tioned in this section when setting up your system.
2.1.1 Work area
Make sure you have a stable, clean working environment.
Dust and dirt can get into components and cause malfunc-
tions. Use containers to keep small components separated.
Putting all small components in separate containers prevents
them from becoming lost. Adequate lighting and proper tools
can prevent you from accidentally damaging the internal
components.
2.1.2 Tools
The following tools will be required to complete the installa-
tions described in this chapter.
A cross head (Phillips) screwdriver
A grounding strap and/or anti static pad
Most of the electrical and mechanical connectors in your sys-
tem can be disconnected using your fingers. It is recom-
mended that you do not use needle-nosed pliers to remove
connectors as these can damage the soft metal or plastic
parts of the connectors.
2.1 Before you begin
10 Chapter 2: Setting up
2.1.3 Precautions
Components and electronic circuit boards can be damaged
by static electricity. Working on a system that is connected to
a power supply can be extremely dangerous. Follow the
guidelines below to avoid damage to the Transport GX21 or
injury to yourself.
Ground yourself properly before removing the top
cover of the system. Unplug the power from the
power supply and then touch a safely grounded
object to release static charge (i.e. power supply
case). If available, wear a grounded wrist strap. Alter-
natively, discharge any static electricity by touching
the bare metal chassis of the unit case, or the bare
metal body of any other grounded appliance.
Avoid touching motherboard components, IC chips,
connectors, memory modules, and leads.
The motherboard is pre-installed in the system.
When removing the motherboard, always place it on
a grounded anti-static surface until you are ready to
reinstall it.
Hold electronic circuit boards by the edges only. Do
not touch the components on the board unless it is
necessary to do so. Do not flex or stress circuit
boards.
Leave all components inside the static-proof packag-
ing that they ship with until they are ready for installa-
tion.
After replacing optional devices, make sure all
screws, springs, or other small parts are in place and
are not left loose inside the case. Metallic parts or
metal flakes can cause electrical shorts.
Always use the correct size screws and fixings when
installing or replacing components.
Note: All connectors are designed to fit
one way only, no force should required to
make a connection.
2.2 Installing motherboard components
Chapter 2: Setting up 11
2.2 Installing motherboard components
This section describes how to install CPUs, memory modules
and PCI card.
2.2.1 Removing the chassis cover
Follow these instructions to remove the Transport GX21
(B5350) chassis cover. This step is required before any other
procedures in this chapter can be undertaken.
1. Remove the four screws that secure the chassis cover.
2. Slide the cover in the direction of the arrow (A) and then
lift the cover off (B).
A
B
2.2 Installing motherboard components
12 Chapter 2: Setting up
2.2.2 Installing CPUs
This section describes how to install Intel® Xeon processors
and heatsinks in your Transport GX21 (B5350) system. This
section applies to all models.
1. Remove the chassis cover as described in section 2.2.1
Removing the chassis cover.
2. Locate the CPU sockets on the motherboard as shown
below.
3. Turn the motherboard upside down to install the heat sink
springs, in the order shown. See 3.2.2 Replacing the
motherboard for instructions on how to remove the moth-
erboard.
A
2.2 Installing motherboard components
Chapter 2: Setting up 13
4. Lift the CPU locking lever as shown below.
5. Place the CPU in the CPU socket, ensuring that pin 1 is
located as shown in the following illustration.
6. Press the CPU locking lever back down to secure the
CPU in the socket.
7. Repeat steps three to six for the second CPU.
8. Apply thermal grease to the top of the CPUs and place
the CPU heatsinks on the CPUs.
pin 1
2.2 Installing motherboard components
14 Chapter 2: Setting up
9. Tighten the four screws to secure the heatsinks in place
as shown below.
Note: CPU heatsinks must be removed to
install or remove memory modules.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70

SIIG B5350 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI