KMH-2000SRH

Hoshizaki KMH-2000SRH, KMH-2000SRH3, KMH-2000SWH, KMH-2000SWH3 User manual

  • Hello! I am an AI chatbot trained to assist you with the Hoshizaki KMH-2000SRH User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Issued: 4-28-2015
Hoshizaki
“A Superior Degree
of Reliability”
www.hoshizaki.com
Models
KMH-2000SWH/3
KMH-2000SRH/3
Stackable Crescent Cuber
Hoshizaki America, Inc.
INSTRUCTION MANUAL
2
IMPORTANT
Only qualied service technicians should install, service, and maintain the
icemaker. No installation, service, or maintenance should be undertaken until
the technician has thoroughly read this Instruction Manual. Likewise, the owner/
manager should not proceed to operate the icemaker until the installer has
instructed them on its proper operation. Failure to install, operate, and maintain
the equipment in accordance with this manual may adversely affect safety,
performance, component life, and warranty coverage.
Hoshizaki provides this manual primarily to assist qualied service technicians in the
installation, maintenance, and service of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily
addressed, please call, write, or send an e-mail message to the Hoshizaki Technical
Support Department for assistance.
HOSHIZAKI AMERICA, INC.
618 Highway 74 South
Peachtree City, GA 30269
Attn: Hoshizaki Technical Support Department
Phone: 1-800-233-1940 Technical Support
(770) 487-2331
Fax: 1-800-843-1056
(770) 487-3360
E-mail: techsuppor[email protected]
Web Site: www.hoshizaki.com
NOTE: To expedite assistance, all correspondence/communication MUST include the
following information:
• Model Number
• Serial Number
• Complete and detailed explanation of the problem.
3
CONTENTS
Important Safety Information ................................................................................................. 4
I. Specications ...................................................................................................................... 5
A. Nameplate Rating ......................................................................................................... 5
1. KMH-2000SWH (water-cooled) ................................................................................ 5
2. KMH-2000SWH3 (water-cooled) ............................................................................. 6
3. KMH-2000SRH (remote air-cooled) ......................................................................... 7
4. KMH-2000SRH3 (remote air-cooled) ....................................................................... 8
B. Dimensions/Connections .............................................................................................. 9
II. Installation and Operating Instructions .............................................................................11
A. Checks Before Installation ............................................................................................11
B. How to Remove Panels ................................................................................................11
C. Location ...................................................................................................................... 12
D. Setup ........................................................................................................................... 12
E. Installation of Upper Unit ............................................................................................. 14
F. Electrical Connection ................................................................................................... 16
G. Installation of Remote Condenser Unit ....................................................................... 18
1. Checks Before Installation ...................................................................................... 18
2. Location ................................................................................................................. 18
3. Setup ..................................................................................................................... 19
4. Line Set ................................................................................................................. 19
5. Refrigerant Charge (Line Set Exceeding 66 Feet) ................................................. 22
6. Electrical Connection ............................................................................................. 22
7. Stacking Remote Condenser Units ........................................................................ 23
H. Water Supply and Drain Connections ......................................................................... 24
1. Icemaker ................................................................................................................ 25
2. Water-Cooled Condenser....................................................................................... 26
a) Connection to an Open Drain System ................................................................ 26
b) Connection to a Closed Loop System ................................................................ 27
I. Final Checklist .............................................................................................................. 28
J. Startup ......................................................................................................................... 29
III. Maintenance ................................................................................................................... 30
A. Maintenance Schedule ................................................................................................ 30
B. Cleaning and Sanitizing Instructions ........................................................................... 31
IV. Preparing the Icemaker for Periods of Non-Use ............................................................. 34
V. Disposal ........................................................................................................................... 36
IMPORTANT
This manual should be read carefully before the icemaker is installed and
operated. Only qualied service technicians should install, service, and
maintain the icemaker. Read the warnings contained in this booklet carefully as
they give important information regarding safety. Please retain this booklet for
any further reference that may be necessary.
4
Important Safety Information
Throughout this manual, notices appear to bring your attention to situations which could
result in death, serious injury, or damage to the unit.
WARNING Indicates a hazardous situation which could result in death or
serious injury.
CAUTION Indicates a situation which could result in damage to the unit.
IMPORTANT Indicates important information about the use and care of the
unit.
WARNING
This icemaker should be destined only to the use for which it has been
expressly conceived. Any other use should be considered improper and
therefore dangerous. The manufacturer cannot be held responsible for eventual
damage caused by improper, incorrect, and unreasonable use.
To reduce the risk of death, electric shock, serious injury, or re, follow
basic precautions including the following:
• Electrical connection must be hard-wired and must meet national, state, and
local electrical code requirements. Failure to meet these code requirements
could result in death, electric shock, serious injury, re, or severe damage to
equipment.
This unit requires an independent power supply. See the nameplate for proper
voltage and breaker/fuse size. Failure to use a proper breaker or fuse can
result in a tripped breaker, blown fuse, or damage to existing wiring. This
could lead to heat generation or re.
THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit could
result in death or serious injury.
This unit should be disassembled or repaired only by qualied service
personnel to reduce the risk of electric shock, injury, or re.
• Do not make any alterations to the unit. Alterations could result in electric
shock, injury, re, or damage to the unit.
5
MOTOR-COMPRESSOR THERMALLY PROTECTED,
NOT INTENDED FOR OUTDOOR USE!
Hoshizaki America, Inc.
Peachtree City, GA
www.hoshizaki.com
ICE MAKER WITHOUT
STORAGE MEANS
946Z
COMPONENT
See the nameplate for electrical and refrigeration specications. This nameplate is located
on the rear panel.
Since this nameplate is located on the rear panel of the icemaker, it cannot be read when
the back of the icemaker is against a wall or against another piece of kitchen equipment.
Therefore, the necessary electrical and refrigeration information is also on the rating label,
which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specications and design without prior notice.
I. Specications
A. Nameplate Rating
1. KMH-2000SWH (water-cooled)
HOSHIZAKI ICE MAKER
MODEL NUMBER KMH-2000SWH
SERIAL NUMBER
AC SUPPLY VOLTAGE
208-230/60/1 (3 WIRE
WITH NEUTRAL FOR
115V)
COMPRESSOR 230V 11.1RLA 73LRA
PUMP 120V 1.2FLA 60W
FAN - - -
OTHER 115V 0.3A
MAXIMUM FUSE SIZE 30 AMPS
MAX. HACR BREAKER(USA ONLY) 30 AMPS
MAX. CIRC. BREAKER (CANADA ONLY) 30 AMPS
MINIMUM CIRCUIT AMPACITY 30 AMPS
DESIGN PRESSURE HI-427PSI LO-230PSI
REFRIGERANT 404A 3 LB. 1.4 OZ.
6
MOTOR-COMPRESSOR THERMALLY PROTECTED,
NOT INTENDED FOR OUTDOOR USE!
Hoshizaki America, Inc.
Peachtree City, GA
www.hoshizaki.com
ICE MAKER WITHOUT
STORAGE MEANS
946Z
COMPONENT
2. KMH-2000SWH3 (water-cooled)
HOSHIZAKI ICE MAKER
MODEL NUMBER KMH-2000SWH3
SERIAL NUMBER
AC SUPPLY VOLTAGE
208-230/60/3
COMPRESSOR 230V 7.8RLA 66LRA
PUMP 120V 1.2FLA 60W
FAN - - -
OTHER 115V 0.3A
MAXIMUM FUSE SIZE 20 AMPS
MAX. HACR BREAKER(USA ONLY) 20 AMPS
MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS
MINIMUM CIRCUIT AMPACITY 20 AMPS
DESIGN PRESSURE HI-427PSI LO-230PSI
REFRIGERANT 404A 3 LB. 1.4 OZ.
See the nameplate for electrical and refrigeration specications. This nameplate is located
on the rear panel.
Since this nameplate is located on the rear panel of the icemaker, it cannot be read when
the back of the icemaker is against a wall or against another piece of kitchen equipment.
Therefore, the necessary electrical and refrigeration information is also on the rating label,
which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specications and design without prior notice.
7
MOTOR-COMPRESSOR THERMALLY PROTECTED,
NOT INTENDED FOR OUTDOOR USE!
Hoshizaki America, Inc.
Peachtree City, GA
www.hoshizaki.com
ICE MAKER WITHOUT
STORAGE MEANS
946Z
COMPONENT
3. KMH-2000SRH (remote air-cooled)
See the nameplate for electrical and refrigeration specications. This nameplate is located
on the rear panel.
Since this nameplate is located on the rear panel of the icemaker, it cannot be read when
the back of the icemaker is against a wall or against another piece of kitchen equipment.
Therefore, the necessary electrical and refrigeration information is also on the rating label,
which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specications and design without prior notice.
HOSHIZAKI ICE MAKER
MODEL NUMBER KMH-2000SRH
SERIAL NUMBER
AC SUPPLY VOLTAGE
208-230/60/1 (3 WIRE
WITH NEUTRAL FOR
115V)
COMPRESSOR 230V 10.9RLA 73LRA
PUMP 120V 1.2FLA 60W
FAN REMOTE 3A MAX
OTHER 115V 0.3A
MAXIMUM FUSE SIZE 30 AMPS
MAX. HACR BREAKER(USA ONLY) 30 AMPS
MAX. CIRC. BREAKER (CANADA ONLY) 30 AMPS
MINIMUM CIRCUIT AMPACITY 30 AMPS
DESIGN PRESSURE HI-467PSI LO-230PSI
REFRIGERANT 404A
8
MOTOR-COMPRESSOR THERMALLY PROTECTED,
NOT INTENDED FOR OUTDOOR USE!
Hoshizaki America, Inc.
Peachtree City, GA
www.hoshizaki.com
ICE MAKER WITHOUT
STORAGE MEANS
946Z
COMPONENT
4. KMH-2000SRH3 (remote air-cooled)
See the nameplate for electrical and refrigeration specications. This nameplate is located
on the rear panel.
Since this nameplate is located on the rear panel of the icemaker, it cannot be read when
the back of the icemaker is against a wall or against another piece of kitchen equipment.
Therefore, the necessary electrical and refrigeration information is also on the rating label,
which can be easily seen by removing only the front panel of the icemaker.
We reserve the right to make changes in specications and design without prior notice.
HOSHIZAKI ICE MAKER
MODEL NUMBER KMH-2000SRH3
SERIAL NUMBER
AC SUPPLY VOLTAGE
208-230/60/3
COMPRESSOR 230V 7.9RLA 66LRA
PUMP 120V 1.2FLA 60W
FAN REMOTE 3A MAX
OTHER 115V 0.3A
MAXIMUM FUSE SIZE 20 AMPS
MAX. HACR BREAKER(USA ONLY) 20 AMPS
MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS
MINIMUM CIRCUIT AMPACITY 20 AMPS
DESIGN PRESSURE HI-467PSI LO-230PSI
REFRIGERANT 404A
9
Note: The storage bin opening must match the bottom opening as in the illustration.
B. Dimensions/Connections
1. KMH-2000SWH/3 (water-cooled)
Unit: mm [in.]
10
2. KMH-2000SRH/3 (remote air-cooled)
Note: The storage bin opening must match the bottom opening as in the illustration.
Unit: mm [in.]
11
II. Installation and Operating Instructions
WARNING
1. This icemaker must be installed in accordance with applicable national, state,
and local regulations.
2. CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews
are securely in place after installation. Make sure that none have fallen into
the storage bin.
A. Checks Before Installation
Visually inspect the exterior of the shipping container and immediately report any
damage to the carrier. Upon opening the container, any concealed damage should also
be immediately reported to the carrier.
• Remove the shipping carton, tape, and packing material. If any are left in the icemaker,
it will not work properly.
• Remove the panels to prevent damage when installing the icemaker. See "II.B. How to
Remove Panels."
• Remove the package containing the accessories.
• Remove the protective plastic lm from the panels. If the icemaker is exposed to the sun
or to heat, remove the lm after the icemaker cools.
• Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the
fan blade (if applicable) turns freely.
• Check that the compressor is snug on all mounting pads.
• See the nameplate on the rear panel, and check that your voltage supplied corresponds
with the voltage specied on the nameplate.
This icemaker can be installed on a storage bin 30" wide or wider with a depth of 40" or
greater.
• On remote air-cooled model, a remote condenser unit is needed. Hoshizaki Remote
Condenser Unit, Model URC-22F is recommended.
B. How to Remove Panels
See Fig. 1
• Front Panel: Remove the 2 screws. Lift up
and towards you.
Top Panel: Remove the 2 screws, and lift off.
• Side Panel (R): Remove the screw. Slide
forward slightly and lift off.
• Side Panel (L): Remove the 6 screws, and
lift off.
• Rear Panel: Remove the 6 screws, and lift
off.
• Insulation Panel: Remove the
thumbscrew. Lift up slightly and pull
towards you.
Fig. 1
Top Panel
Insulation
Panel
Front Panel
Side Panel (R)
Side Panel (L)
Top
Insulation
Rear
Panel
12
C. Location
CAUTION
1. This icemaker is not intended for outdoor use. Normal operating ambient
temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating
water temperature should be within 45°F to 90°F (7°C to 32°C). Operation
of the icemaker, for extended periods, outside of these normal temperature
ranges may affect icemaker performance.
2. This icemaker will not work at sub-freezing temperatures. To prevent damage
to the water supply line, drain the icemaker if the air temperature is going to
go below 32°F (0°C). See "III.C. Preparing the Icemaker for Long Storage."
For best operating results:
The icemaker should not be located next to ovens, grills, or other high heat producing
equipment.
The location should provide a rm and level foundation for the equipment.
Allow 6" (15 cm) clearance at exposed side(s), rear, and top for proper air circulation and
ease of maintenance and/or service should they be required.
D. Setup
CAUTION
Before operating the icemaker, the bin control thermostat assembly must be
installed correctly. Failure to properly install the assembly could result in ice
backup and unit damage.
1) Assemble the storage bin according
to the manufacturer's instructions.
2) Position the storage bin in the
selected permanent location.
3) Level the storage bin in both
the left-to-right and front-to-rear
directions according to the
manufacturer's instructions.
4) Place the icemaker on top of the
storage bin.
5) Secure the icemaker to the storage
bin using the 2 mounting brackets
and the bolts provided. See Fig. 2.
5) Install the bin control thermostat as follows:
a. Remove the baffle from the bin (if applicable).
Fig. 2
Mounting Brackets
Bolts
Icemaker
Ice
Storage
Bin
13
b. Remove the tie securing the bin control thermostat assembly. Remove the
2 thumbscrews and the "Z" bracket. See Fig. 3.
c. Remove the bin control thermostat assembly from the shipping hook. Lower the
thermostat extension bracket (stainless) with the thermostat bulb attachment and
thermostat bulb through the hole located at the bottom of the icemaker. Next, lower
the thermostat bracket (plastic) through the hole.
d. Slide the left side of the upper part of the assembly towards you and make sure it
is hooked on the wall. Make sure the left side and bottom of the assembly are ush
against the wall and base panel.
e. Secure the assembly in place with the thumbscrews (unless you are installing an
upper unit).
f. Insert the plug into the receptacle on the assembly until it locks into place.
Note: Icemaker will not run if the plug is not in the receptacle.
g. Remove the 2 screws securing the thermostat bulb attachment (plastic) to the
thermostat extension bracket (stainless). See Fig. 4. Use the 2 screws to attach the
"Z" bracket (plastic) to the thermostat extension bracket (stainless).
h. Use the two 4×10 stainless steel screws
in the accessory bag to attach the
thermostat bulb attachment (with attached
thermostat bulb) to the "Z" bracket.
i. Remove the 2 screws from the lower part
of the thermostat bracket (plastic) and use
them to attach the thermostat extension
bracket (stainless) to the thermostat
bracket (plastic).
j. Make sure the silicone hose is in place to
prevent ice from striking the capillary tube.
Fig. 4
Fig. 3
Bin Control
Thermostat
Assembly
Shipping Hook
Thermostat Bracket
(plastic)
Tie
"Z" Bracket
Thermostat Bulb
Attachment (plastic)
and Thermostat Bulb
Thumbscrews
Thermostat Extension
Bracket (stainless)
Hole
Plug
Receptacle
Thumbscrews
Hook
Bushing
Thermostat Bracket
(plastic)
Thermostat Bulb
Attachment (plastic)
"Z" Bracket (plastic)
Thermostat Extension
Bracket (stainless)
Silicone Hose
14
6) Conrm that the icemaker and storage bin are level in both the left-to-right and
front-to-rear directions. If necessary, level the storage bin in both the left-to-right and
front-to-rear directions according to the storage bin manufacturer's instructions.
7) Replace the panels and baffle (if applicable) in their correct positions (unless you are
installing an upper unit). See "II.E. Installation of Upper Unit."
E. Installation of Upper Unit
1) See "II.D. Setup" for the lower unit installation.
2) Remove the top panel and the top insulation of the lower unit. The top panel and the top
insulation of the lower unit are not required when installing an upper unit.
3) Unpack the upper unit, and remove the shipping carton, tape, and packing material.
4) Remove the panels of the upper unit.
5) Stack the upper unit on top of the lower unit.
6) Secure the upper unit to the lower unit using the 2 mounting brackets and the bolts
provided. See Fig. 5.
Ice
Storage
Bin
Icemaker
(Upper
Unit)
Icemaker
(Lower
Unit)
Fig. 5
Mounting Brackets
Bolts
15
7) Install the bin control thermostat as follows:
a. Remove the thermostat bulb attachment (plastic) of the upper unit from the
thermostat extension bracket (stainless). See Fig. 6.
b. Carefully remove the thermostat bulb from the thermostat bulb attachment (plastic) of
the upper unit, then remove the silicone hose from the capillary tube.
c. Carefully route the thermostat bulb and capillary tubing of the upper unit through
the bottom hole of the upper unit. Remove the bushing from the lower bin control
thermostat assembly. Route the bulb and tubing through the hole in the assembly
and down into the bin. Reattach the bushing.
d. Secure the lower bin control thermostat assembly in place with the thumbscrews.
e. Slide the silicone hose onto the capillary tube, then carefully insert the thermostat
bulb back into the thermostat bulb attachment (plastic).
f. Secure the thermostat bulb attachment (plastic) of the upper unit to the thermostat
bulb attachment (plastic) of the lower unit with the screws of the upper unit.
g. Make sure the silicone hose is in place to prevent ice from striking the capillary tube.
h. Insert the plug of the upper unit into the receptacle of the upper unit's bin control
thermostat assembly until it locks into place.
Note: Icemaker will not run if the plug is not in the receptacle.
8) Replace the panels and baffle in their correct positions.
Thermostat
Capillary
Tubing
Fig. 6
Thermostat Extension
Bracket (stainless)
Thermostat
Bulb Attachment
Removed from
Upper Unit
Thermostat Bulb
Attachment of
Lower Unit
Thermostat Bulb
"Z" Bracket
(plastic)
Silicone Hose
16
F. Electrical Connection
WARNING
For All Models
1. Electrical connection must be hard-wired and must meet national, state, and
local electrical code requirements. Failure to meet these code requirements
could result in death, electric shock, serious injury, re, or extensive damage
to equipment.
2. This unit requires an independent power supply. See the nameplate for proper
voltage and breaker/fuse size. Failure to use a proper breaker or fuse can
result in a tripped breaker, blown fuses, or damage to existing wiring. This
could lead to heat generation or re.
3. THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit could
result in death or serious injury.
4. Electrical connection must be made in accordance with the instructions on
the "WARNING" tag, provided with the pig tail leads in the junction box. See
Fig. 7a and 7b.
Additional Warnings for Remote Air-Cooled Model
5. THE REMOTE CONDENSER UNIT MUST BE GROUNDED. The power
supply and ground wire to the remote condenser unit are supplied from the
icemaker. See "II.G.6. Electrical Connection."
6. To reduce the risk of electric shock, make all remote condenser unit
connections before connecting the icemaker power supply.
7. On remote air-cooled model, the icemaker should have power for a minimum
of 4 hours prior to startup to prevent compressor damage.
• Usually an electrical permit and services of a licensed electrician are required.
The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• On single phase models, the white lead must be connected to the neutral conductor of the
power source. CAUTION! Miswiring may result in severe damage to the icemaker.
KMH-2000SWH
KMH-2000SRH
Fig. 7a
WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage
to the icemaker. The white lead
must be connected to the neutral
conductor of the power source.
See diagram below.
4A4801-010
208-230/60/1
(3 wire with neutral for 115V)
JUNCTION BOX
208-230
V
BROWN
BLACK
L1
L2
WHITE
N
1
15-
120V
17
Fig. 7b
KMH-2000SWH3
KMH-2000SRH3
WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage to
the icemaker.
This unit must be connected to a
three-phase power source.
The transformer’s voltage tap switch
must be positioned to match incoming
voltage at startup.
See diagram below.
208-230/60/3
4A4807-010
JUNCTION BOX
208-230
V
BROWN
BLACK
L1
L3
RED
L2
208-
230V
208-
230V
• On three phase models, the transformer's voltage tap switch must be positioned to match
incoming voltage at startup.
CAUTION! On three phase models, connect the highest incoming voltage supply
("stinger leg") to the red power supply wire (red common wire to the compressor).
The opening for the power supply connection is 7/8" DIA to t a 1/2" trade size conduit.
18
G. Installation of Remote Condenser Unit
WARNING
1. Installation of remote condenser unit must be performed by properly trained
and EPA-certied service personnel.
2. Failure to install the equipment within these guidelines may adversely affect
safety, performance, component life, and warranty coverage.
1. Checks Before Installation
1) Remove the shipping carton, tape, and packing material.
2) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the
fan blades move freely.
2. Location
CAUTION
The remote condenser unit is intended for outdoor use. Normal operating
ambient temperature should be within -20°F to +122°F (-29°C to +50°C).
Operation of the remote condenser unit, for extended periods, outside of this
normal temperature range may affect icemaker performance.
The remote condenser unit must be positioned in a permanent site under the following
guidelines:
A rm and at site.
A dry and well ventilated area with 24" (61 cm) clearance in both front and rear for
proper air circulation and ease of maintenance and/or service should they be required.
See Fig. 8.
The maximum line length for the standard refrigerant charge is 66 feet. With additional
refrigerant, the maximum line length is 100 feet. For details, see "II.G.5. Refrigerant
Charge (Line Set Exceeding 66 Feet)."
The maximum vertical distance between the remote condenser unit and the icemaker
is 33 feet above or 10 feet below the icemaker. These distances are measured tting to
tting. See Fig. 9.
Fig. 8
Air
Min. 24" (61 cm) Clearance
Air
Fig. 9
Icemaker
Remote
Condenser
Unit
Service Loop
Max. 33 Feet
Ice
Storage
Bin
19
3. Setup
1) Secure the legs to the remote
condenser unit with the 8 bolts and
nuts provided. See Fig. 10.
2) The legs have 8 mounting holes.
Secure the legs with 8 bolts (not
included).
4. Line Set
CAUTION
The icemaker, line set, and remote condenser unit must contain the same
type of refrigerant. Mixing of refrigerants will result in improper operation and
possible damage to the refrigeration system.
• Precharged factory line sets, available as optional equipment from Hoshizaki America, are
recommended. For details, see "II.G.4.a) Factory Line Set Installation." Field fabricated
line sets are allowed. For details, see "II.G.4.b) Field Fabricated Line Set Installation."
The maximum line length for the standard refrigerant charge is 66 feet. With additional
refrigerant, the maximum line length is 100 feet. For details, see "II.G.5. Refrigerant
Charge (Line Set Exceeding 66 Feet)."
a) Factory Line Set Installation
1) Route the factory line set (5/8" OD discharge line and 3/8" OD liquid line) from the
remote condenser unit to the icemaker. Leave a service loop behind the icemaker to
allow the icemaker to be pulled out for service. See Fig. 11. Factory fabricated line sets
are precharged and do not need to be evacuated. If the line set is too long or too short,
see "II.G.4.a)(1) Factory Line Set Modication."
CAUTION
1. Ensure that there are no traps and no kinks in the line set.
2. Do not coil extra line set.
2) Connect the refrigerant lines to the appropriate male ttings on the remote condenser
unit rst and then at the icemaker. Make a proper connection as follows:
a. Remove the protective covers from the male tting and female coupling.
b. Apply Polyol Ester (POE) refrigerant oil or Parker Super O Lube to the entire male
tting, including O-ring, diaphragm, and threads before making the connection. See
Fig. 12.
CAUTION
Do not use thread sealant on the ttings. Use POE refrigerant oil or Parker
Super O Lube only.
Fig. 10
Bolts with Split
Lock Washer
and Flat Washer
Nuts
Mounting Holes
20
c. Make sure the male tting and female coupling are properly aligned, then start the
connection by hand to ensure that it is not cross threaded.
d. Tighten the connection with a wrench until it is tight. At this point, the nut has covered
most of the threads on the male tting.
e. Mark a reference line on the female coupling and the remote condenser unit or
icemaker panel. Using a backup wrench on the back of the female coupling, tighten
the six-sided nut of the female coupling an additional 1/6 turn. See Fig. 13.
3) If you lengthened the line set as outlined in "II.G.4.a)(1) Factory Line Set Modication"
and it exceeds 66 feet, see "II.G.5 Refrigerant Charge (Line Set Exceeding 66 Feet)" for
proper charging of the unit.
(1) Factory Line Set Modication
1) Recover the line set charge through the Schrader access ports on the Parker quick
connect couplings and store it in an approved container. Do not discharge the refrigerant
into the atmosphere. Remove the extra line set length or add extra tubing. When adding
extra tubing, insulate the additional copper tubes separately. Braze the connections.
2) Use an electronic leak detector or soap bubbles to check for leaks. Add a trace
of refrigerant to the lines through the Schrader access ports on the Parker quick
connect couplings (if using an electronic leak detector), and then raise the pressure
using nitrogen gas (140 PSIG). WARNING! DO NOT use R-404A as a mixture with
pressurized air for leak testing.
3) Evacuate through the Schrader access ports on the Parker quick connect couplings and
charge with R-404A refrigerant vapor to a pressure of 15 to 30 PSIG. Go to step 2 in
"II.G.4.a) Factory Line Set Installation."
b) Field Fabricated Line Set Installation
1) Route a 5/8" OD copper tube discharge line and a 3/8" OD copper tube liquid line
between the remote condenser unit and the icemaker. Leave a service loop behind the
icemaker to allow the icemaker to be pulled out for service. See Fig. 11.
CAUTION
1. Ensure that there are no traps and no kinks in the line set.
2. Do not coil extra line set. Fabricate the line set to the proper length.
2) Insulate the two copper tubes separately.
3) Install Parker quick connect couplings on each end. OS-QUICK (HS-2150), a universal
quick connect coupling kit available as optional equipment from Hoshizaki America, is
recommended. CAUTION! Before brazing, remove the Schrader valve core from the
access port. When brazing, protect the coupling by using a wet cloth to prevent
the coupling from overheating.
4) Allow the coupling to cool, then replace the Schrader valve core.
5) Use an electronic leak detector or soap bubbles to check for leaks. Add a trace
of refrigerant to the lines through the Schrader access ports on the Parker quick
connect couplings (if using an electronic leak detector), and then raise the pressure
using nitrogen gas (140 PSIG). WARNING! DO NOT use R-404A as a mixture with
pressurized air for leak testing.
/