  • Hello! I am an AI chatbot trained to assist you with the Gibraltar Building Products 13194 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
These installation guidelines are for use with typical or standard applications. It is always recommended to seek advice from a licensed professional, and to
check with your local building inspector or building permit office for approvals and possible variations that may apply.
FURRING CHANNEL
Furring Channel, also known as Hat Channel, is a corrosion-resistant framing component used to to level uneven surfaces
prior to applying drywall sheets to walls and ceilings.
In typical wood frame wall applications Furring Channel is
attached perpendicular to framing, with #9 x 1-1/2 in.
screws or 10d nails. Space the channels 16" or 24" O.C.
In ceiling applications, furring channels can be attached
directly to the underside of the building structure using tie
wire, screws or nails.
Where Furring Channel needs to be spliced, a minimum 6"
overlap is required. The splice is secured with 2 sheet
metal screws.
When "furring out" a concrete wall, Furring Channel should
be attached vertically with concrete nails or power
actuated fasteners.
6"
MINIMUM
OVERLAP
8"
24" 24"
48"
24"
Staggered
Nailing
Pattern
FURRING CHANNEL
INSTALLATION GUIDELINES
/