Contec IPC-POA200/12-01 Owner's manual

Type
Owner's manual
IPCシリーズ
電源ユニット
Power Supply Unit
IPC-POA200/12-01
取扱説明書
User’s Guide
CONTEC CO., LTD. - 1 -
Power Supply Unit
IPC-POA200/12-01 User’s Guide
Thank you for purchasing the IPC-POA200/12-01 power supply unit.
The IPC-POA200/12-01 is the dedicated power supply unit for the following CONTEC Flat Panel
displays and Flat Panel Computer.
Flat Panel Display: IPC-DT/M20V(PC)T, IPC-DT/L20S(PC)T, IPC-DT/H20X(PC)T
Flat Panel Computer: IPC-PT/MSH3VV Series
Warning
Indicates dos and don'ts that are assumed to result in possible death or serious injury if they are
inappropriately handled ignoring this icon.
- Do not use the product in locations exposed to a flammable or corrosive gas. It may cause explosion,
fire, electrical shock, or malfunction.
- If you sense abnormality (smoke, odor, or noise), immediately unplug the power cord from the wall
outlet and contact the CONTEC sales representative or sales office.
- To avoid electrocution do not use the product with a wet hand.
- Prevent foreign matters (such as metal pieces, combustibles, and liquids) from penetrating into the
product through ventilation holes, for example, to prevent a fire or electrical shock.
- Be sure to connect the product to the stipulated power supply voltage. Connecting to a different
voltage might cause a fire or electrical shock.
- Be sure to ground the product.
- Never disassemble or modify the product or replace its parts in order to prevent electrical shock,
fire, or malfunction. CONTEC reserves the right to refuse servicing the product modified by the
user. When any part of the product needs to be replaced at the expiration of its life or due to
breakdown, please contact the CONTEC sales representative or sales office.
IPC-POA200/12-01
- 2 - CONTEC CO., LTD.
Caution
Indicates dos and don'ts that are assumed to result in possible injury or property damage if they are
inappropriately handled ignoring this icon.
- Use the product in the stipulated operating environment (temperature and humidity).
- When installing the product, be sure to disconnect the power cable.
- Do not use or store the product in a location exposed to extremely high or low temperature or
susceptible to a rapid temperature change. Example:
- Exposure to direct sun
- In the vicinity of a heat source
- To clean the product wipe it gently with soft cloth damp with either water or mild detergent.
Do not use chemicals or a volatile solvent, such as benzene and thinner, to prevent peeling or
discoloration of the paint.
- Avoid installation that blocks ventilation holes. Blocking contains heat inside the product causing it
to malfunction or break down.
- CONTEC is not liable for the product that has been modified by the user.
- When transporting the product, provide adequate measures to protect it from vibration or shock.
-
Estimated life is about 10 years based on continual operation at 40°C (Vertical installation).
However, (higher) operating temperatures will result in shorter life.
Features
- No extra installation work is necessary since the unit can be installed directly.
- A broad continuous input voltage range of 100-240VAC.
Package Contents
The product you have purchased consists of the following items. Be sure that you have them all. If you
find any item either missing or damaged, please contact the sales representative you purchased the
product from.
- Power supply unit…1
- AC power cable…1 *
- 3-piece screws (M3 x 6)…2
- User’s Guide (this document)…1
- Warranty Certificate …1
- Serial number label …1
* This AC power cable is for the voltage of the 125VAC or less. In the case that the voltage that this
cable uses do not match you need to prepare other cable particularly.
IPC-POA200/12-01
CONTEC CO., LTD. - 3 -
External Dimensions and Component Identification
204
37
648.5
[mm]
AC inlet
DC cable
Screw holes
(for M3 screws)
Power switch
Installation Procedure
First be sure that the power switch of the power supply unit is set to off and then connect the power
supply unit DC cable to the connector of Flat Panel Display or Flat Panel Computer.
DC Cable
IPC-POA200/12-01
- 4 - CONTEC CO., LTD.
Power Connection
Specifications
Power supply specs
Rated input voltage 100VAC to 240VAC (continuous input), 50/60Hz
Rated input current
0.8A (Max.) (AC IN 100V)
0.4A (Max.) (AC IN 200V)
Rated output voltage +12VDC
Rated output current 2.5A (Max.)
Permissible momentary blackout 20ms (AC IN 100V, Io=100%, (Typ.))
2.0kVAC for one minute
Greater than 50M
Ω
(500VDC)
Environmental specs
Operating temperature 0 to 50
°
C
Storage temperature -20 to 75
°
C
Humidity 20 to 85%RH (No condensation)
Floating dust particles Not to be excessive
Corrosive gases None
Line-noise AC line/2kV, Signal line/1kV (IEC1000-4-4Level 3, EN61000-4-4Level 3)
Contact discharge/4kV (IEC1000-4-2Level 2, EN61000-4-2Level 2)
Atmospheric discharge/8kV (IEC1000-4-2Level 3, EN61000-4-2Level 3)
10 to 50Hz/semi-amplitude 0.15mm, 57 to 150Hz/2.0G
23 minutes each in X, Y, and Z directions
(JIS C0040-compliant, IEC68-2-6-compliant)
Fixed vibration
resistance
16.7Hz/2G, 30 minutes each in X, Y, and Z directions
(JIS C0040- and IEC68-2-6-compliant)
Impact resistance
10G, half-sine shock for 11ms in X, Y, and Z directions
(JIS C0041-compliant, IEC68-2-27-compliant)
Construction
External dimensions (mm) 205(W)×72.5(D)×37(H)
Weight 530g(Cable not included)
Dielectric strength
(between Input and FG)
Insulation resistance
(between input and FG)
Vibration
resistance
Static electricity
resistance
Line-Noise
resistance
Requirement Description
Sweep resistance
IPC-POA200/12-01
CONTEC CO., LTD. - 5 -
Copyright
Copyright 2012 CONTEC Co., LTD. ALL RIGHTS RESERVED
No part of this document may be copied or reproduced in any form by any means
without prior written consent of CONTEC Co., LTD.
CONTEC Co., LTD. makes no commitment to update or keep current the information
contained in this document. The information in this document is subject to change
without notice.
All relevant issues have been considered in the preparation of this document. Should
you notice an omission or any questionable item in this document, please feel free to
notify CONTEC Co., LTD.
Regardless of the foregoing statement, CONTEC assumes no responsibility for any
errors that may appear in this document nor for results obtained by the user as a result
of using this product.
Limited One-Year Warranty
CONTEC IPC Series are warranted by CONTEC Co., LTD to be free from defects in
material and workmanship for up to one year from the date of purchase by the original
purchaser.
Repair will be free of charge only when this device is returned freight prepaid with a
copy of the original invoice and a Return Merchandise Authorization to the distributor
or the CONTEC group office, from which it was purchased.
This warranty is not applicable for scratches or normal wear, but only for the electronic
circuitry and original boards. The warranty is not applicable if the device has been
tampered with or damaged through abuse, mistreatment, neglect, or unreasonable use,
or if the original invoice is not included, in which case repairs will be considered
beyond the warranty policy.
How to Obtain Service
For replacement or repair, return the device freight prepaid, with a copy of the original
invoice. Please obtain a Return Merchandise Authorization Number (RMA) from the
CONTEC group office where you purchased before returning any product.
* No product will be accepted by CONTEC group without the RMA number.
Liability
The obligation of the warrantor is solely to repair or replace the product. In no event
will the warrantor be liable for any incidental or consequential damages due to such
defect or consequences that arise from inexperienced usage, misuse, or malfunction of
this device.
IPC-POA200/12-01
- 6 - CONTEC CO., LTD.
A-46-556
LYAH612
130215 [011212]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7