TOA Electronics Europe GmbH
4
Setting of Relay Function
The activation of the internal and the external speakers can be controlled by the control input depending on the settings of
the jumpers J51-1/2/3/4 ( ). For setting refer to following list:
Jumper Setting Control
J51-1 speaker(s) OFF
J51-2 speaker(s) ON
J51-3 switch over to external speaker
J51-4 switch OFF internal and external speaker
Set jumpers either to 1 or2, and to either 3 or 4.
The external control is made via pin 20 by making a contact to ground.
? SPECIFICATIONS
Inputs 12 channels, 1V AC or 100V AC selectable
control input ground input to switch ON/OFF internal/external speaker
speaker output 3W / 8 ohms (minimum impedance 4 ohms if internal speaker will be
switched off when external speaker is in use)
Headphone 6.3 mm phone plug
max. power: 8 ohms: 125 mW, 32 ohms: 200 mW, 100 ohms: 150 mW,
200 ohms: 100 mW, 600 ohms: 40 mW
Switch 12-step rotary switch for channel selection
Volume control speaker volume
Indicators 7-LED bar graph for level: -20 ~ +6 dB
Speaker 8 ohms / 3W internal
Power requirements 24V DC
Power consumption without speaker signal: 60 mA, max. 350 mA
Fuse 0.5A T (slow characteristics)
Connection 44-pin card-edge connector
Dimensions 80 (W) x 129 (H) x 194 (D) mm
Weight 470 g
Finish black
* Specifications are subject to change without notice
? ACCESSORIES
44-pin card-edge connector
if relay is activated
if headphone is connected