Fahrenheat FBE User manual

Category
Space heaters
Type
User manual

This manual is also suitable for

FBE15002
Portable Electric
Baseboard Heater
WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAU-
TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE
THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO
PERSONS, INCLUDING THE FOLLOWING:
1. Read all instructions before using the heater.
2. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.
3. Always plug heaters directly into a wall outlet/receptacle.
Never use with and extension cord or relocatable power tap
(outlet/power strip).
4. Do not operate any heater with a damaged cord or plug or
after the heater malfunctions, has been dropped or dam-
aged in any manner. Discard heater or return to an author-
ized service facility for examination, and/or repair.
5. Do not run cord under carpeting. Do not cover cord with
throw rugs, runners, or similar coverings. Do not route cord
under furniture or appliances. Arrange cord away from traf-
fic area and where it will not be tripped over.
6. Always unplug heater when not in use.
7. To disconnect, rotate thermostat to the LO set point or flip
ON-OFF switch to off. Then grip plug (not cord) and pull
from outlet.
8. A heater has hot and arcing or sparking parts inside. Do not
use in areas where gasoline or flammable liquids are used
or stored.
9. This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, and cur-
tains away from heater.
10. To prevent a possible fire, do not block air intakes or
exhaust in any manner. Do not use on soft surfaces, like a
bed, where openings may become blocked.
11. Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock or
fire, or damage the heater.
12. This heater is not intended for use in bathrooms, laundry
areas and similar indoor (wet) locations. Never locate
heater where it may fall into a bathtub or other water con-
tainer.
13. Do not operate heater without support legs installed see
ASSEMBLY INSTRUCTIONS.
14. This heater is intended for floor use only. Do not place on
shelf, table, or any location except the floor.
SAVE THESE INSTRUCTIONS
!
Installation, Operation & Maintenance Instructions
WARNING
MODEL
NO.
VOLTS WATTS AMPS
1500/1000
BTU/HR
FBE15002 120V
12.5/8.3
5120/3413
GENERAL
This heater is designed to provide years of efficient, trouble free operation as a supplementary heat source for comfort heating in
residential applications. Use of this product in any manner not described herein will void the warranty and could result in injury,
damage to property, or permanent damage to heater.
IMPORTANT INSTRUCTIONS
ASSEMBLY INSTRUCTIONS
Heater Assembly
1. After removing the heater from its carton, carefully inspect
it for possible shipping damage. Return damaged units to
point of purchase.
2. Remove plastic support leg extensions from packaging.
Line up the slots and slide extension into end panels as
shown. (See Figure 1).
OPERATION INSTRUCTIONS
IMPORTANT NOTICE:
This heater is a major electrical appli-
ance and requires adequate electrical power. The outlet to
which this heater is connected must be a 120 volt (AC) circuit
protected by a 15 or 20 amp fuse or circuit breaker. No other
major electrical appliance should be operated in the same circuit
as the heater.
Care must be given in locating and using the heater to avoid
blocking the heater in any way to allow air to flow freely through
the heater. Keeping the heater clean will also help improve the
efficiency and prevent overheating.
WARNING:
The heater plug must fit tightly into outlet. A loose
fitting or worn outlet may allow for the plug connection to heat,
damage to the plug and/or outlet and may cause a fire. If outlet
is loose or worn, discontinue using heater until the outlet can be
replaced.
SPECIAL NOTE:
You may notice a new smell coming from
your heater during initial use. It should go away within the first
few hours of operation. You may also notice it does not heat up
immediately. Because of the special tubular element design, it
takes a few minutes before you can feel the warmth through the
cabinet.
1. Never place anything on top of the heater. It is recommend-
ed that a space of at least 12 inches (30 mm) be maintained
around the heater.
2. When moving heater, turn heater controls to LO or ON-OFF
switch to OFF and remove plug from outlet. Allow heater to
cool and then pick up by grasping heater cabinet along top
and back side.
3. Do not allow heater to operate in any position except as
shown in this manual.
Heater Operation
1. Heater must be properly installed before operation.
2. The FBE15002 is provided with a POSITIVE OFF thermo-
stat. In addition to the thermostat, the FBE15002 has a
LO/HI heat selection switch.
3. Operation:
a. Plug heater power supply into 120 volt outlet.
b. Move heat selection switch to the left position for LO
(1000 watts) or to the right for HI (1500 watts).
c. Rotate the thermostat knob clockwise until it stops.
4. Allow the heater to operate normally until the room tempera-
ture is comfortable to you. Then simply rotate the thermostat
knob to the left until the thermostat clicks. The thermostat
will then automatically turn your heater on and off to maintain
the room temperature.
5. To adjust the room temperature, rotation of the thermostat
knob to the right will increase the heater output while rotation
of the thermostat knob to the left will decrease the output.
The numbers on the thermostat knob are for reference only
and may help you in setting and adjusting the heater output
for your comfort.
6. To turn heater off, rotate the thermostat knob to the left until
it stops. Always unplug heater when not in use.
MAINTENANCE INSTRUCTIONS
For efficient and safe operation and to extend the life of your
heater it should be cleaned and inspected for damage at least
annually (preferably at the beginning of the heater season) or
more often in dirty environments. Other than cleaning, your
heaters require no other preventative maintenance.
1. Heater cabinet may be cleaned using a damp cloth to
remove dust that may have accumulated on surfaces. Do
not use harsh cleaners and waxes on surfaces since these
could damage the finish or discolor in use.
2. A vacuum cleaner and / or compressed air may be used to
remove dust and lint that may have accumulated inside
heater around element fins.
3. After cleaning and servicing, check units to make sure they
are operating properly.
THERMAL SAFETY SWITCH:
Your heater is provided with an
automatic-resetting thermal safety switch that will disconnect
power to the heating element should the heater be placed into
an abnormal condition (such as a blockage) to prevent a fire.
When the heater cools, the safety switch will reset allowing the
heater to return to normal operation.
FINS MAY CAUSE CUTS, DO NOT TOUCH
TO PREVENT A POSSIBLE ELECTRIC SHOCK, ALWAYS
UNPLUG HEATER FROM OUTLET BEFORE CLEANING OR
SERVICING.
ALLOW HEATER TO COOL BEFORE CLEANING TO
PREVENT A POSSIBLE BURN.
2
Correct
Incorrect
Figure 1
05/10
Part No. 5200-2307-002
ECR 38723
LIMITED WARRANTY
All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation.
This warranty does not apply to damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to
equipment improperly installed or wired or maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of
the date of installation.
The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products
to Marley Engineered Products Service Center. Within the limitations of this warranty, inoperative units should be returned to the nearest Marley authorized service cen-
ter or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that
such repair or replacement is the exclusive remedy available from Marley Engineered Products.
THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM
THIS AGREEMENT. MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE
PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state.
For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the fac-
tory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization,
include all catalog numbers shown on the products.
HOW TO OBTAIN WARRANTY SERVICE AND
WARRANTY PARTS PLUS GENERAL INFORMATION
1. Warranty Service or Parts
1-800-642-4328
2. Purchase Replacement Parts
1-800-654-3545
3. General Product Information
www.marleymep.com
Note:
When obtaining service always have the following:
1. Model number of the product
2. Date of manufacture
3. Part number or description
470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Fahrenheat FBE User manual

Category
Space heaters
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI