C
© ,©
mm ml
0
Disconnect powersupply to outlet.
lm
Desooneoteel suministro el_otrico del tomacorriente de
pared.
Put on gioves and safety glasses= 2o POngaseIos guantesy Ios anteojos protectores=
Disconnectand move freestanding rangeto provide easier 3. Desconectey muevaia cocina autoestabieparatener f_cil
accessor put a protective cover over a cooktop= accesoo ponga una cubierta protectora en la encimera=Saque
Removeall contents from upper cabinet, todos ios objetos dei gabinetesuperior=
Using measuringtape, find and ctearIymarkthe verticat
centeriine ® of the cabinet opening on the wall direcey
under the upper cabinet=
m
Con unacinta de medir, iocaticey marque con claridad ia linen
central verticai @ deIaabertura deIgabineteenla pared
directamente debajo dei gabinetesuperior.
Line up paper waii template centerline with centerline on
wali=Tapeor tack watl tempiate to waft=Top of template
must be located a minimum of 66" from floor.
Note:
o If front edge of cabinet is iower than back edge,adjust
top of wall template to be levelwith front edge.
m
rear wall--
pared trasera
J
Tapof wall template must align with
front edge of cabieet.
La parts superior de la piantHia de
pared debe a_ieearse con el bards
delantero del gabinete.
Alinee IaIineacentral de Iaplantiiia de paredcon IaIinea
central de ia pared. Fijecon cinta o clave contachueias ia
ptantiiia de pareda ia pared. La partesuperior de la ptantilla
debe quedara un minima de 66" desdeetpiso.
12
Nora:
oSi el bards delanterode!gabineteestAmAs bajo que et bards
posterior, ajuste ia parts superior de ia piantilla de pared para
que quede niveiadacon ei bards deiantero=
Findand mark the location of alI waii studs on wafttemplate=
If there are no waft studs in the opening area, DONOTinstall
microwave hood. Consult your building inspector.
m
Locaiicey marque Ia ubicaci6n de todos los montantes de
pared en ia piantiiia de pared=
Si no hay montantes de pareden el _rea de Iaabertura, NO
instaie ia campanadel homo=Consults con su inspector de
construcci6n=
Piacethe Uppercabinet template against the bottom of the
upper cabinet. The "rear wall" arrows must be against the
rear wall so that the homescutin the cannot bottom and
the holes in the top of the microwave cabinet will align.
1
ColoqueIapiantiila de pared dei gabinetesuperior contra ia
basedei gabinetesuperior. Lasfleohas de la "Pared Trasera"
deben estar contra la pared trasera de manera que los
orificioshechos en Jabase del gabinete y losorificies en la
If the cabinet bottom has a frame around it, trim the
template edgesso that the template fits inside the frame
againstthe cabinet bottom. Thetempiate hastrim iinesto
useas guides, important: The t8-7/16" dimension from the
rear wall to holes "J" and 'I(" must be maintained.
0
wall template
Plantilla de pared
parts superior del gabinete del homo microondas queden
alineados.
Si ia basedel gabinetetiene un marco, carte ios bordes de ia
plantiiia para que ia piantiiia encajedentro dot marco,contra ia
basedetgabinete. La piantiiia tiene linens de carte que deben
usarse coma guias, tmportante: se debe mantener la
distanoia de 18o7/16"de Japared trasera a Josorificios
"J" y "K".
Checkif points "D" and"E", or "F" and "G"on walitemptateare
overa waftstud ®: if pointsareovera waftstud,drill 3/16"
hoies=if pointsareoverdrywall,driii 3/4"holes.
If thereisnota watistud at points"D" and "E", or"F" and"G"
or at onlyoneset of points,find within shadedareas"H" and"I"
thescrew pointsclosestto thecenterofwaftstud(s). Driii3,/16"
holes® into wailstud(s).Twoor preferablyfour lagscrews
mustbe usedto securemountingpintoto waii.
Note:the mountingpmatetViUSTbe scouredtothe wall atthe
fourcorner points "[1" and "E", or "F" and "G", usingeither
1/4o28x3"bolts and toggleheadsor 1/4 x 2"Jagscrews.
(Referto Section Cpage 15.)
Thelocation of your wall stud(s) may differ from what is
shown,
m
Verifique que ios puntos "D" y "E', o "F" y "G" deiapiantiiia
de pared est6n sabre un montante de pared®: siios puntos
est_n sabre un montantede pared,haga orificios de 3/16"=Si
los puntos est_n sabre un muro interior sin mortero, haga
orificios de 3/4".
Si no hay ning_n montante de pared en ios puntos "D" y "E",
o "F" y "G", o s6Io en un par de puntos, iocaiice dentro de Ins
_reassombreadas"H" e "I" los puntos para torniiios m_s
cercanosal centro dei montante oios montantes de pared=
Hagaorificios de 3/16" ® en ei montanteo en ios montantes
de pared. Debenusarsedos o, preferiblemente,cuatro
tornilIos de cabezacuadrada para maderaparafijar la placade
montaje de pared=
Nora: ia placa de montaje DEBEfijarse a la pared en los
puntos de ins coatro esquinas "g" y "E" o "F" _'"G",
usando ya sea pernos de cabeza redonda o acodillada de
t/4-28 x 3" o tornillos con cabezacuadrada para madera de
1/4 x 2" (Consults la Seaside Cen map_gina t5).
Sus montantes de pared podrian edar en lugaresdiferentes de
los que se muestranen la ilustracien=
continued onpage I4 continElaen ia pdgina t4 :1.3