Delfield Heated Individually Controlled Food Wells Product information

Type
Product information
Diagram
DELFIELD
980 SOUTH ISABELLA ROAD, MOUNT PLEASANT, MI 48858
844-724-CARE
WWW.DELFIELD.COM
Models with Energy Savings Power (ESP)/Low Watt Heating Elements
240V
Service Notes
The temperature probes are mounted directly to the heat pad and can only be tested with a meter that can read type J
thermocouples. When testing the probe read the temperature of the hot food well.
When replacing the well not to apply pressure directly to the pad.
Heater Resistance: 240 Volt Heaters Min 109.20 ~ Max 120.80
Individually Controlled Heated Food Wells
CART & KIOSK MODELS: SH Heated Serving Carts Without Heated Understorage & SHC Hot & Ice Cooled Serving Carts
CONCEPT MODELS: DC-H Heated Serving Counters & DCRU-H Radial Heated Serving Counters
DROPIN MODELS: N8700D, N8700DESP, N8700-R & N8700N Series Individually Controlled Heated Food Wells
ECHEF™ MODELS: EHEI Hot Food Tables
F14 SERIES MODELS: F14EI Electric Hot Food Tables With Individual Wells
SHELLEYBASIC® MODELS: SE(S)-H Heated Counters
SHELLEYGLAS® MODELS: KH Heated Serving Counters Without Heated Understorage & KHC Hot & Ice Cooled Serving Counters
SHELLEYSTEEL® MODELS: SLT4 & SH Heated Serving Counters Without Heated Understorage & SHC Hot & Ice Cooled Serving Counters
1 of 4
WDHtd IndWells 07/15
2 of 4
WDHtd IndWells 07/15
Individually Controlled Heated Food Wells
Models with 120, 208-230, or 120/208-230 Voltage, 60 Cycle, 1 Phase
(excluding energy savings power (ESP)/low watt heating element models)
Neutral
L2
Neutral Wire For 120 Volt Options
L1
GND
(DPST Switch) Master On/O Switch 1
Units With 1, 2, 3 Or 4 Food Wells Have 1 Master On/o Switch
Switches Are Standard On Some, Optional On Others
Pilot Light
Pilot Light
Pilot Light
Pilot Light
Pilot Light
Pilot Light
L2
L1
P
H2
Hl
Innite Control
Heater
Limit Switch
L2
L1
P
H2
H1
Innite Control
Heater
Limit Switch
Food Well
Food Well
L2
L1
P
H2
H1
Innite Control
Heater
Limit Switch
Food Well
L2
L1
P
H2
H1
Innite Control
Heater
Limit Switch
L2
L1
P
H2
H1
Innite Control
Heater
Limit Switch
Food Well
L2
L1
P
H2
H1
Innite Control
Heater
Limit Switch
Food Well
(DPST Switch) Master On/O Switch 2
Units With 5 Or 6 Food Wells Have 2 Master On/o Switches
Switches Are Standard On Some, Optional On Others
O
Hi
Lo
6
1
5
2
4
3
Amperes In Line Wires
# of Food
Wells
120V
1 Phase
208V
1 Phase
230V
1 Phase
1 10.0 5.0 5.5
2 20.0 10.0 11.0
3 30.0 15.0 16.0
4 40.0 20.0 22.0
5 24.0 27.0
6 29.0 32.0
3 of 4
WDHtd IndWells 07/15
Individually Controlled Heated Food Wells
Models with 208-230 Voltage, 60 Cycle, 3 Phase
Amperes In Line Wires
# of Food
Wells
208-230V, 3 Phase
Line1 Line2 Line3
2 6.0/7.3 3.0/3.6 3.0/3.6
3 9.0/11.0 9.0/11.0 9.0/11.0
4 9.0/11.0 9.0/11.0 6.0/7.3
5 17.0/20.0 9.0/11.0 9.0/11.0
6 17.0/20.0 17.0/20.0 17.0/20.0
4 of 4
WDHtd IndWells 07/15
Individually Controlled Heated Food Wells
Models with 240 Volt, 50 Cycle, 1 Phase
Control BoxUnit
GRN W/ YLW 16GA - #MCP00195
GRN W/ YLW 16GA - #MCP00195
Innite
Control
Heating Element
Thermostat
Pilot Light
Pilot
Innite
Control
Pilot Light
Pilot
H1
L1
H2
L2
Thermostat
Heating Element
Innite
Control
Pilot Light
Pilot
Thermostat
Heating Element
Innite
Control
Pilot Light
Pilot
Thermostat
Heating Element
Innite
Control
Pilot Light
Pilot
Thermostat
Heating Element
Innite
Control
Pilot Light
Pilot
Thermostat
Heating Element
H1
H2
L1
L2
H1
L1
H2
L2
H1
H2
L1
L2
H1
H2
L1
L2
H1
H2
L1
L2
Or Breaker
Wires From Cord