Comtech EF Data DMD-2050E Operating instructions

Category
Networking
Type
Operating instructions
MN-DMD2050E Revision 2
Comtech EF Data is an
AS9100 Rev B / ISO9001:2000 Registered Company
DMD-2050E
Universal Satellite Modem
Installation and Operation Manual
IMPORTANT NOTE: The information contained in this document supersedes all previously published information
regarding this product. Product specifications are subject to change without prior notice.
ER-DMD2050E-EA2 Rev - PLM C-0028800
Errata A for MN-DMD2050E Rev 2
Comtech EF Data Documentation Update
Subject:
Chapter 3, Theory of Operation
Errata Part Number:
ER-DMD2050E-EA2 (Errata documents are not subject to revision.)
PLM CO Number:
C-0028800
Comments:
The new information will be included in the next released revision of the manual.
IMPORTANT
Set the modem to Loop Timing mode for these Loopback operations:
Tx/Rx Terrestrial Loopback
Tx/Rx Baseband Loopback
Rx Baseband Loopback
ER-DMD2050E-EA2 Rev - PLM C-0028800
Blank Page
ER-DMD2050E-EB2 Rev - PLM C-0028804
Errata B for MN-DMD2050E Rev 2
Comtech EF Data Documentation Update
Subject:
Chapter 3 and Chapter 4 references to MN-DMDREMOTEOP manual
Errata Part Number:
ER-DMD2050E-EB2 (Errata documents are not subject to revision.)
PLM CO Number:
C-0028804
Comments:
The new information will be included in the next released revision of the manual. See
the following pages.
DMD2050E Universal Satellite Modem User Interfaces
MN-DMD2050E Revision 2 4–31
4.4.6.6 SNMP (menu)
A description of OID organization is provided in the MN-DMDREMOTEOP manual.
SNMP MENU
SNMP VERSION {V1 & V2, V3} This selection controls the SNMP Version that will be used in
messaging between the equipment and it’s host.
When V1 & V2 is used, RD COMMUNITY and RDWR
COMMUNITY are used to determine the authorization of an
incoming message.
When V3 is used, three contexts are supported:
public
,
mib2
, and
dev
. Context, Authentication and Privacy are a portion of each
SNMPV3 message.
The
public
context will only allow the user to see the sysoid of the
unit. This is the most restricted access possible and only allows
the unit to be identified by a host SNMP Station.
The
mib2
context allows a user with appropriate authentication to
access the mib2 OIDs and the SNMP OIDs. These are of interest
primarily to network operators not controlling the satellite link.
The
dev
context allows a user with appropriate authentication to
access the device control portion of the MIB. These OIDs are
used to control the devices satellite link and operation.
TRAP VERSION {V1, V2} This controls the type of message format used when a message
trap is generated by the equipment and bound for a SNMP Host.
Messages will only be sent if the unit has been authorized to do
so.
AUTHORIZATION {TRAPS OFF, TRAPS
ON}
This controls the type of message format used when a message
trap is generated by the equipment and bound for a SNMP host.
Messages will only be sent if the unit has been authorized to do
so.
RD COMMUNITY {16 characters of
name}
This menu is only displayed when SNMP VERSION is set to V1 &
V2. This is the community that a host must be acting within when
an OID variable is requested by a V1/V2 SNMP message.
RDWR COMMUNITY {16 characters of
name}
This menu is only displayed when SNMP VERSION is set to V1 &
V2. This is the community that a host must be acting within when
an OID variable is being changed by a V1/V2 SNMP message.
TRAP AGENT {XXX.XXX.XXX.XXX}
Hexadecimal Mask
{ddd.ddd.ddd.ddd}
Decimal Mask
IP address of the device receiving SNMP Traps
DMD2050E Universal Satellite Modem Theory of Operation
MN-DMD2050E Revision 2 3–8
Modem Status, Alarms & Contact Closures (Section 3.2.9)
3.2.6 Terminal Port
This port supports an asynchronous control protocol as described in Chapter 4. It is configured to
support RS-232 signal levels. This port is intended for use in computer-based remote M&C. All
functions of the modem may be monitored and controlled from this port via a common terminal
connected to the Terminal Port. This function is front panel selectable.
The Terminal Mode Control allows the use of an external terminal or computer to monitor and
control the modem from a full screen interactive presentation operated by the modem itself. No
external software is required other than VT-100 Terminal Emulation Software (e.g. “Procomm”
for a computer when used as a terminal. The Control Port is normally used as an RS–232
Connection to the terminal device. The RS-232 operating parameters can be set using the
modem Front Panel and stored in Non-volatile memory for future use.
IMPORTANT
Refer to the Remote Protocol Manual (MN-DMDREMOTEOP) for the Terminal, Remote
and SNMP screens and protocols.
3.2.7 Modem Remote Communications (RLLP)
The Remote Port located on J20 allows for control and monitoring of parameters and functions
via an RS-232 Serial Interface, or RS-485 for RLLP Protocol. ‘Equipment Remote Mode’ setup
can be entered from the front panel or the Web Browser interface under the “System” menu. This
requires the user to first set the Remote Port Control to “Remote” then set the Multidrop Address
as needed followed by setting the Remote Interface to RS232 or RS485.
Control and status messages are conveyed between the modem and all subsidiary modems and
the host computer using packetized message blocks in accordance with a proprietary
communications specification. This communication is handled by the Radyne Link Level Protocol
(RLLP), which serves as a protocol ‘wrapper’ for the remote M&C data. See the MN-
DMDREMOTEOP manual for more information.
ER-DMD2050E-EB2 Rev - PLM C-0028804
Blank Page
Copyright © Comtech EF Data, 2013. All rights reserved. Printed in the USA.
Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.2200, FAX: 480.333.2161
Comtech EF Data is an
AS9100 Rev B / ISO9001:2000 Registered Company
DMD2050E
Universal Satellite Modem
Installation and Operation Manual
Part Number MN-DMD2050E
Revision 2
BLANK PAGE
DMD-2050E Universal Satellite Modem Revision 2
Table of Contents MN-DMD2050E
iii
Table of Contents
PREFACE ................................................................................................................................. XIX
About this Manual .................................................................................................................................. xix
Cautions and Warnings .......................................................................................................................... xix
Patents and Trademarks ......................................................................................................................... xix
Related Documents ................................................................................................................................ xix
Electrical Safety ...................................................................................................................................... xx
Battery ..................................................................................................................................................... xx
Grounding ............................................................................................................................................... xx
Fuses ....................................................................................................................................................... xx
Telecommunications Terminal Equipment Directive ............................................................................. xx
Environmental ........................................................................................................................................ xxi
Low Voltage Directive (LVD) ............................................................................................................... xxi
EMC (Electromagnetic Compatibility) .................................................................................................. xxi
CE Mark ................................................................................................................................................ xxii
RoHS ..................................................................................................................................................... xxii
Product support ..................................................................................................................................... xxiii
On the web ........................................................................................................................................... xxiii
Return material authorization ............................................................................................................... xxiii
Support business hours ........................................................................................................................ xxiii
After hours and weekends .................................................................................................................... xxiii
Comtech EF Data and Radyne support contacts .................................................................................. xxiii
Warranty Policy ..................................................................................................................................... xxiv
Limitations of Warranty ....................................................................................................................... xxiv
Exclusive Remedies ............................................................................................................................. xxiv
CHAPTER 1. INTRODUCTION ............................................................................................. 1–1
1.1 Overview ...................................................................................................................................... 1–1
1.2 DMD2050E Configurations ........................................................................................................ 1–2
1.2.1 Features ................................................................................................................................. 1–2
1.2.2 Advanced Forward Error Correction and Modulation .......................................................... 1–3
1.2.3 Bandwidth Compression ....................................................................................................... 1–3
1.2.4 Interfaces ............................................................................................................................... 1–4
1.2.5 Remote Control and Monitoring ........................................................................................... 1–4
1.2.6 Compatibility ........................................................................................................................ 1–4
1.2.7 Physical Description ............................................................................................................. 1–4
1.2.7.1 Dimensional Envelope ...................................................................................................... 1–5
1.3 Configurations and Options ....................................................................................................... 1–6
DMD-2050E Universal Satellite Modem Revision 2
Table of Contents MN-DMD2050E
iv
CHAPTER 2. INSTALLATION .............................................................................................. 2–1
2.1 Unpacking and Inspection .......................................................................................................... 2–1
2.2 Installation Safety ....................................................................................................................... 2–2
2.3 Installation Considerations ........................................................................................................ 2–2
2.3.1 Location ................................................................................................................................ 2–3
2.3.2 Airflow .................................................................................................................................. 2–3
2.3.3 Temperature .......................................................................................................................... 2–3
2.3.4 Electrical Power .................................................................................................................... 2–3
2.3.5 Cables .................................................................................................................................... 2–4
2.4 Initial Configuration Check ....................................................................................................... 2–4
2.4.1 Standard Factory Configuration ............................................................................................ 2–4
2.5 Modulator Checkout ................................................................................................................... 2–5
2.5.1 Initial Start Up ....................................................................................................................... 2–5
2.5.2 Factory Terminal Settings ..................................................................................................... 2–5
CHAPTER 3. THEORY OF OPERATION ............................................................................. 3–1
3.1 DMD2050E Hardware ................................................................................................................ 3–1
3.1.1 DMD2050E L-Band/IF Printed Circuit Card ........................................................................ 3–2
3.1.2 DMD2050E Baseband Processing Printed Circuit Card ....................................................... 3–3
3.1.3 Enhanced Interface Printed Circuit Card .............................................................................. 3–5
3.2 DMD2050E Functional Block Diagram .................................................................................... 3–5
3.2.1 Front Panel ............................................................................................................................ 3–5
3.2.2 Baseband Processing ............................................................................................................. 3–5
3.2.3 Tx Baseband Processing ....................................................................................................... 3–6
3.2.4 Rx Baseband Processing ....................................................................................................... 3–7
3.2.5 Monitor & Control (M&C) Subsystem ................................................................................. 3–7
3.2.6 Terminal Port ........................................................................................................................ 3–8
3.2.7 Modem Remote Communications (RLLP) ........................................................................... 3–8
3.2.8 Ethernet M&C Port ............................................................................................................... 3–9
3.2.9 Modem Monitor Status ......................................................................................................... 3–9
3.3 Internal Clock ............................................................................................................................ 3–10
3.4 Loopback Features (Terrestrial & IF) .................................................................................... 3–10
3.5 DMD2050E
Clocking Options .................................................................................................. 3–13
3.5.1 Clock Selection ................................................................................................................... 3–13
3.5.2 TX Clock Options ............................................................................................................... 3–14
3.5.2.1 SCTE: Serial Clock Transmit External ........................................................................... 3–15
3.5.2.2 SCT: Serial Clock Transmit ............................................................................................ 3–15
3.5.3 RX Buffer Clock Options ................................................................................................... 3–16
3.5.3.1 RX SAT Clock ................................................................................................................ 3–16
3.5.3.2 SCTE: Serial Clock Transmit External ........................................................................... 3–16
DMD-2050E Universal Satellite Modem Revision 2
Table of Contents MN-DMD2050E
v
3.5.3.3 SCT: Serial Clock Transmit ............................................................................................ 3–17
3.5.3.4 EXT CLK/EXT BNC: External Clock, J16 .................................................................... 3–17
3.5.3.5 EXT IDI: Insert Data In .................................................................................................. 3–17
3.5.4 EXT REF: External Reference, Top BNC Port, J10 ........................................................... 317
3.6 Transmit Timing Options ......................................................................................................... 3–18
3.6.1 MIL-188-114A, RS-422 (TX Clock Source - SCT or SCTE) ............................................ 3–18
3.6.2 G.703 Interface ................................................................................................................... 3–18
3.6.3 HSSI Interface ..................................................................................................................... 3–18
3.6.4 Ethernet Data Interface (Optional) ...................................................................................... 3–19
3.7 Receive Timing Options............................................................................................................ 3–19
3.7.1 Loop Timing ....................................................................................................................... 3–19
3.7.2 Transmit (MIL-188-114A, RS-422) ................................................................................... 3–19
3.7.3 G.703 Interface or Asymmetrical Data Rates ..................................................................... 3–19
3.7.4 Receive ................................................................................................................................ 3–19
3.8 Ebem Framing Unit .................................................................................................................. 3–20
3.8.1 DMD2050E Information Throughput Adpatation (ITA) .................................................... 3–20
3.8.2 Embedded Channel ............................................................................................................. 3–20
3.9 STANAG Turbo Coding ........................................................................................................... 3–20
3.10 FIPs TRANSEC Module .......................................................................................................... 3–21
3.10.1 Traffic Encryption and Decryption Keys and Key Generation ........................................... 3–21
3.10.1.1 Key Agreement ........................................................................................................... 3–21
3.10.1.2 Key Agreement Algorithm .......................................................................................... 3–24
3.10.1.2.1 Key Derivation ........................................................................................................ 3–24
3.10.1.3 Accessing Encryption/Decryption Features ................................................................ 3–24
3.10.1.4 Enabling Encryption from the Front Panel ................................................................. 3–24
3.11 DoubleTalk Carrier-in-Carrier Option .................................................................................. 3–26
3.11.1 What is DoubleTalk Carrier-in-Carrier? ............................................................................. 327
3.11.2 Application Requirements ................................................................................................... 3–27
3.11.3 Operational Guidelines ....................................................................................................... 3–29
3.11.4 System Functionality and Operational Considerations ....................................................... 3–30
3.11.5 DoubleTalk Carrier-in-Carrier Cancellation Process
.......................................................... 3–33
3.11.6 Margin Requirements .......................................................................................................... 3–35
3.11.7 Carrier-in-Carrier Latency .................................................................................................. 3–35
3.11.8 Carrier-in-Carrier and Adaptive Coding and Modulation ................................................... 3–35
3.11.9 Carrier-in-Carrier Link Design ........................................................................................... 3–35
3.11.9.1 Symmetric Data Rate Link .......................................................................................... 336
3.11.9.2 Asymmetric Data Rate Link ....................................................................................... 3–39
3.11.9.3 Power Limited Links ................................................................................................... 3–41
3.11.10 Carrier-in-Carrier Commissioning and Deployment....................................................... 3–42
3.11.11 Validating Carrier-in-Carrier Performance ..................................................................... 3–44
3.11.12 Operational References ................................................................................................... 3–45
3.11.12.1 Carrier-in-Carrier Link Budget Calculation ................................................................ 3–45
3.11.12.2 Estimating PSD Ratio ................................................................................................. 3–46
3.11.12.3 Estimating PSD Ratio from LST................................................................................. 3–46
DMD-2050E Universal Satellite Modem Revision 2
Table of Contents MN-DMD2050E
vi
3.11.12.4 Estimating PSD Ratio from Satmaster ........................................................................ 3–47
3.11.12.5 Estimating PSD Ratio Using Spectrum Analyzer ....................................................... 3–47
3.11.13 DoubleTalk Carrier-in-Carrier Specifications ................................................................. 3–48
3.11.14 Carrier-in-Carrier Summary ............................................................................................ 3–49
3.11.15 Glossary .......................................................................................................................... 3–49
3.12 TPC and Low Density Parity Check (LDPC) Coding ........................................................... 3–51
3.12.1 LDPC versus TPC ............................................................................................................... 3–52
3.12.2 TPC and LDPC Summary ................................................................................................... 3–56
3.13 Reed-Solomon Codec ................................................................................................................ 356
3.13.1 Reed-Solomon Operation in the DMD2050E ..................................................................... 3–56
3.13.2 Reed-Solomon Code Rate ................................................................................................... 3–57
3.13.3 Interleaving ......................................................................................................................... 3–57
3.14 DMD2050E Automatic Uplink Power Control (AUPC Operation) ..................................... 3–58
3.15 Asynchronous Overhead Operation (Async Port / ES-ES Communications) ..................... 358
3.16 Standard IBS Mode .................................................................................................................. 3–60
3.17 Asynchronous Multiplexer Mode ........................................................................................... 3–61
3.18 ESC Backward Alarms ............................................................................................................. 3–61
3.18.1 To Disable the ESC Backward Alarms ............................................................................... 3–62
3.19 Satellite Control Channel (SCC) ............................................................................................. 362
3.19.1 SCC Framing Structure ....................................................................................................... 3–62
3.19.2 Aggregate Data Rate ........................................................................................................... 3–64
3.19.3 Overhead Rate Comparison ................................................................................................ 3–65
3.19.4 Actual Overhead Rate Calculation ...................................................................................... 3–66
3.20 SCC OVERHEAD CHANNEL SETUP .................................................................................. 3–67
3.21 Locating the DMD2050E ID Code Operational Procedure .................................................. 369
CHAPTER 4. USER INTERFACES ....................................................................................... 4–1
4.1 User Interfaces ............................................................................................................................ 4–1
4.2 Front Panel Interface .................................................................................................................. 4–1
4.2.1 VFD - Vacuum Fluorescent Display ..................................................................................... 4–2
4.2.2 Arrow Keys ........................................................................................................................... 4–2
4.2.3 Numeric Keys ....................................................................................................................... 4
–2
4.2.4 LED Lights ............................................................................................................................ 4–3
4.3 Parameter Setup .......................................................................................................................... 4–4
4.3.1 Select a Parameter ................................................................................................................. 4–4
4.3.2 Enter and Save a New Parameter .......................................................................................... 4–4
4.3.3 Change a New Parameter Before Saving .............................................................................. 4–4
DMD-2050E Universal Satellite Modem Revision 2
Table of Contents MN-DMD2050E
vii
4.4 Front Panel Main Menus ............................................................................................................ 4–4
4.4.1 MODULATOR Main Menu and Parameters ........................................................................ 4–5
4.4.1.1 NETWORK SPEC (menu) ................................................................................................ 4–5
4.4.1.2 STRAP CODE .................................................................................................................. 4–6
4.4.1.3 IF (menu) .......................................................................................................................... 4–6
4.4.1.4 DATA (menu) ................................................................................................................... 4–6
4.4.1.4.1 EBEM NETWORK SPEC Parameters ....................................................................... 4–8
4.4.1.4.2 SCC FRAMING Parameters ....................................................................................... 4–8
4.4.1.5 REED-SOLOMON (menu) ............................................................................................... 4–9
4.4.1.6 AUPC (menu) ................................................................................................................... 4–9
4.4.1.7 LOCAL AUPC (menu) ................................................................................................... 4–10
4.4.1.8 REMOTE AUPC (menu) ................................................................................................ 4–13
4.4.1.9 ITA (menu) ..................................................................................................................... 4–13
4.4.2 DEMODULATOR Main Menu and Parameters ................................................................. 4–14
4.4.2.1 NETWORK SPEC (menu) .............................................................................................. 4–14
4.4.2.2 STRAP CODE ................................................................................................................ 4–15
4.4.2.3 IF (menu) ........................................................................................................................ 4–15
4.4.2.4 DATA (menu) ................................................................................................................. 4–16
4.4.2.5 REED-SOLOMON (menu) ............................................................................................. 4–17
4.4.2.6 CNC (menu) .................................................................................................................... 4–18
4.4.2.7 ITA (menu) ..................................................................................................................... 4–18
4.4.3 INTERFACE Main Menu and Parameters ......................................................................... 4–19
4.4.3.1 TX SETUP (menu) .......................................................................................................... 4–19
4.4.3.1.1 DROP & INSERT (menu) ........................................................................................ 4–21
4.4.3.1.2 TX ASYNC MODE (menu) ..................................................................................... 4–21
4.4.3.2 RX SETUP (menu) ......................................................................................................... 4–22
4.4.3.2.1 DROP & INSERT (menu) ........................................................................................ 4–23
4.4.3.2.2 RX ASYNC MODE (menu) ..................................................................................... 4–23
4.4.3.3 GENERAL (menu) ......................................................................................................... 424
4.4.4 MONITOR Main Menu and Parameters ............................................................................. 4–24
4.4.4.1 LINK STATUS (menu) .................................................................................................. 4–25
4.4.4.2 VOLTAGES (menu) ................................................................................................
....... 4–27
4.4.4.3 CnC (menu) ..................................................................................................................... 4–27
4.4.4.4 ITA (menu) ..................................................................................................................... 4–27
4.4.5 ALARMS Main Menu and Parameters ............................................................................... 4–28
4.4.6 SYSTEM Main Menu and Parameters ................................................................................ 4–28
4.4.6.1 FRONT PANEL (menu) ................................................................................................. 4–28
4.4.6.2 REMOTE CONTROL .................................................................................................... 4–28
4.4.6.3 TERMINAL (menu) ....................................................................................................... 4–29
4.4.6.4 REMOTE PORT (menu) ................................................................................................ 4–29
4.4.6.5 TCP/IP (menu) ................................................................................................................ 4–29
4.4.6.6 SNMP (menu) ................................................................................................................. 431
4.4.6.7 FTP (menu) ..................................................................................................................... 4–32
4.4.6.8 WEB (menu) ................................................................................................................... 4–32
4.4.6.9 TRANSEC (menu) .......................................................................................................... 4–33
4.4.6.10 HW/FW CONFIG (menu) .......................................................................................... 4–33
4.4.6.10.1 MAIN BOARD (menu) .......................................................................................... 4–34
4.4.6.10.2 FEATURES (menu) ................................................................................................ 4–35
4.4.6.10.3 UPGRADE LIST (menu) ........................................................................................ 4–35
4.4.7 TEST Main Menu and Parameters ...................................................................................... 4–36
DMD-2050E Universal Satellite Modem Revision 2
Table of Contents MN-DMD2050E
viii
4.5 Terminal Mode Control............................................................................................................ 4–38
4.5.1 Terminal Mode Screens ...................................................................................................... 4–38
4.5.2 Terminal Mode Operations ................................................................................................. 4–38
4.5.3 Setup for Terminal Mode .................................................................................................... 439
CHAPTER 5. EXTERNAL CONNECTIONS .......................................................................... 5–1
5.1 Power Connectors, Ground and Switches ................................................................................ 5–2
5.1.1 Ground Connector ................................................................................................................. 5–2
5.1.2 Power Switch ........................................................................................................................ 5–2
5.2 Front Panel Connections ............................................................................................................ 5–3
5.2.1 Key Loader Interface ............................................................................................................ 5–3
5.3 Rear Panel Connectors ............................................................................................................... 5–4
5.3.1 HSSI / Ethernet Connectors .................................................................................................. 5–4
5.3.2 EXT REF (J10) ..................................................................................................................... 5–5
5.3.3 IF Connectors (Transmit and Receive) J11, J12, J13, J14 .................................................... 5–5
5.3.4 ALARM (J15) ....................................................................................................................... 5–6
5.3.4.1 IBS Network Alarms Configuration ................................................................................. 5–7
5.3.4.2 Closed Net Alarms Configuration ..................................................................................... 5–7
5.3.4.3 RTS Carrier Alarms Configuration ................................................................................... 5–7
5.3.5 EXT CLK (J16) ..................................................................................................................... 5–7
5.3.6 ASYNC (J17) ........................................................................................................................ 5–8
5.3.7 ANT. HANDOVER (J18) (Future Option) ........................................................................... 5–8
5.3.8 MIL-188-114A (J19)............................................................................................................. 5–9
5.3.9 Monitor and Control Connectors J20, J21 .......................................................................... 5–10
CHAPTER 6. MAINTENANCE AND TROUBLESHOOTING ................................................ 6–1
6.1 Periodic Maintenance ................................................................................................................. 6–1
6.1.1 Battery Replacement ............................................................................................................. 6–1
6.1.2 Clock Adjustment ................................................................................................................. 6–1
6.1.3 Fuse Replacement ................................................................................................................. 6–1
6.2 Troubleshooting .......................................................................................................................... 6–2
6.2.1 Basic Troubleshooting Procedures ........................................................................................ 6–2
6.2.2 Troubleshooting Symptoms and Causes ............................................................................... 6–2
6.2.2.1 Symptom: The modem does not acquire the incoming carrier. .......................................
6–2
6.2.2.2 Symptom: The ASYNC port is not configured correctly. ................................................ 6–2
6.3 Alarms .......................................................................................................................................... 6–3
6.3.1 Major Transmit Alarms ......................................................................................................... 6–3
6.3.2 Major Rx Alarms .................................................................................................................. 6–3
6.3.3 Minor Tx Alarms .................................................................................................................. 6–4
6.3.3.1 Minor Rx Alarms .............................................................................................................. 6–5
6.3.3.2 Drop and Insert Alarms ..................................................................................................... 6–6
6.3.3.3 Common Major Alarms .................................................................................................... 6–6
DMD-2050E Universal Satellite Modem Revision 2
Table of Contents MN-DMD2050E
ix
6.4 Alarm Masks ............................................................................................................................... 6–8
6.4.1 Active Alarms ....................................................................................................................... 6–8
6.4.1.1 Major Alarms .................................................................................................................... 6–8
6.4.1.2 Minor Alarms .................................................................................................................... 6–8
6.4.2 Common Equipment Alarms ................................................................................................ 6–9
6.4.3 Latched Alarms ..................................................................................................................... 6–9
6.4.4 Backward Alarms ................................................................................................................ 6–11
6.5 IBS Alarms and Actions ........................................................................................................... 6–12
CHAPTER 7. TECHNICAL SPECIFICATIONS ..................................................................... 7–1
7.1 Modulator .................................................................................................................................... 7–1
7.2 Demodulator ................................................................................................................................ 7–2
7.3 Plesiochronous Buffer ................................................................................................................. 7–3
7.4 Monitor and Control ................................................................................................................... 7–3
7.5 Terrestrial Interfaces .................................................................................................................. 7–4
7.6 IBS/Synchronous Interface (Standard) ..................................................................................... 7–4
7.7 High-Speed Serial Interface (HSSI) & Gigi Ethernet Data Interface .................................... 7–4
7.8 Key loader interface .................................................................................................................... 7–4
7.9 Environmental ............................................................................................................................. 7–4
7.10 Physical ........................................................................................................................................ 7–4
7.11 Data Rate Limits ......................................................................................................................... 7–5
7.11.1 Non-DVB .............................................................................................................................. 7–5
7.11.2 DVB ...................................................................................................................................... 7–7
7.12 BER Specifications ...................................................................................................................... 7–9
7.12.1 BER Performance (Viterbi) .................................................................................................. 7–9
7.12.2 BER Performance (Sequential) ........................................................................................... 7–10
7.12.3 BER Performance (Viterbi with Reed-Solomon) ............................................................... 7–11
7.12.4 BER Performance (Turbo) .................................................................................................. 7–12
7.12.5 BER Performance (8PSK Trellis) ....................................................................................... 7–13
7.12.6 BER Performance (8PSK Turbo) ........................................................................................ 7–14
7.12.7 BER Performance (16QAM Viterbi) .................................................................................. 7–15
7.12.8 BER Performance (16QAM Viterbi with Reed-Solomon) ................................................. 7
16
7.12.9 BER Performance (16QAM Turbo) .................................................................................... 7–17
7.12.10 BER Performance (OQPSK Turbo) ................................................................................ 7–18
7.12.11 BER Performance (BPSK Turbo) ................................................................................... 7–19
7.12.12 BER Performance (8PSK Turbo) .................................................................................... 7–20
7.12.13 BER Performance (16QAM Turbo) ................................................................................ 7–21
DMD-2050E Universal Satellite Modem Revision 2
Table of Contents MN-DMD2050E
x
7.12.14 B/O/QPSK BER Performance (LDPC) ........................................................................... 7–22
7.12.15 8PSK / 8QAM BER Performance (LDPC) ..................................................................... 7–23
7.12.16 16QAM BER Performance (LDPC) ............................................................................... 7–24
7.12.17 BER Performance B/O/QPSK (MILSTD 188-165B or STANAG) Turbo ..................... 7–25
7.12.18 BER Performance 8-PSK (MILSTD 188-165B or STANAG) Turbo ............................ 7–26
7.12.19 BER Performance 16APSK (MILSTD 188-165B or STANAG) Turbo ......................... 7–27
7.13 AGC Output Voltage ................................................................................................................ 7–34
APPENDIX A. PRODUCT OPTIONS .................................................................................... A–1
A.1 Hardware Options ..................................................................................................................... A–1
A.2 Custom Options .......................................................................................................................... A–1
APPENDIX B. FRONT PANEL UPGRADES AND DEMONSTRATION MODE .................. B–1
B.1 Introduction ................................................................................................................................ B–1
B.2 Required Equipment ................................................................................................................. B–1
B.3 Procedures .................................................................................................................................. B–1
B.3.1 Record the Features and Options ......................................................................................... B–2
B.3.2 Record the Unit ID ............................................................................................................... B–3
B.3.3 Order the Demonstration or the Upgrade ............................................................................. B–3
B.3.4 Install the Code .................................................................................................................... B–4
B.3.5 Demonstration Mode Considerations ................................................................................... B–5
B.3.6 Cancel the Demonstration Mode .......................................................................................... B–6
APPENDIX C. CARRIER CONTROL ................................................................................... C–1
C.1 Carrier Control and Alarms ..................................................................................................... C–1
C.2 Carrier States and Changes to Programming ......................................................................... C–1
C.3 Carrier States ............................................................................................................................. C–2
C.3.1 Carrier OFF .......................................................................................................................... C–2
C.3.2 Carrier ON ........................................................................................................................... C–2
C.3.3 Carrier AUTO ...................................................................................................................... C–2
C.3.4 Carrier VSAT ....................................................................................................................... C–3
C.3.5 CARRIER RTS .................................................................................................................... C–3
APPENDIX D. WEB INTERFACE SETUP GUIDE .............................................................. D–1
D.1 Introduction ................................................................................................................................ D–1
D.2 Setup
............................................................................................................................................ D–1
D.2.1 TCP-IP Menus ..................................................................................................................... D–1
DMD-2050E Universal Satellite Modem Revision 2
Table of Contents MN-DMD2050E
xi
D.2.2 IP Address ............................................................................................................................ D–2
D.3 Web Interface Security .............................................................................................................. D–2
D.3.1 Default User Accounts ......................................................................................................... D–2
D.3.2 User Account Data ............................................................................................................... D–3
D.1 User Account Setup ................................................................................................................. D–3
D.1.1 Edit the User ID. .................................................................................................................. D–4
D.1.2 Edit the Access Group.......................................................................................................... D–4
D.1.3 Edit the Authentication Password. ....................................................................................... D–4
D.2 Reset a User Account ................................................................................................................. D–5
D.3 Confirmation .............................................................................................................................. D–5
D.4 Equipment Website .................................................................................................................... D–6
D.4.1 Log in to the Equipment Website ........................................................................................ D–7
D.5 Web Page Appearance ............................................................................................................... D–8
D.6 Configure Web Browsers for the Radyne WEB Interface ..................................................... D–9
D.6.1 Configure Internet Explorer 9 for the Radyne WEB Interface ............................................ D–9
D.6.2 Configure Firefox for the Radyne WEB Interface ............................................................... D–9
D.6.2.1 Change the encoding: ..................................................................................................... D–10
D.6.2.2 Install the Internet Explorer Tab V2 add-on .................................................................. D–11
D.6.3 Configure Chrome for the Radyne WEB Browser ............................................................ D–12
D.6.3.1 Change the encoding ...................................................................................................... D–13
D.6.3.2 Install the Internet Explorer Tab for Chrome ................................................................. D–14
D.6.4 Configure Safari for the Radyne WEB Browser ................................................................ D–15
D.6.4.1 Empty the browser cache ............................................................................................... D–15
D.6.4.2 Reset the Ethernet M&C port ......................................................................................... D–16
D.6.4.3 Re-enter the Modem IP address ..................................................................................... D–16
D.6.4.4 Change the encoding ...................................................................................................... D–18
D.6.5 Configure Maxthon for the Radyne WEB Browser ........................................................... D–19
D.6.5.1 Change the browser mode .............................................................................................. D–20
D.6.5.2 Change the encoding ...................................................................................................... D–21
APPENDIX E. DROP AND INSERT (STANDARD AND EFFICIENT OPTIONS) ............. E–1
E.1 Introduction ................................................................................................................................ E–1
E.2 System Requirements ................................................................................................................ E–
1
E.3 Configuration Examples ............................................................................................................ E–2
E.4 Functional Descriptions ............................................................................................................. E–4
E.4.1 Drop Only ............................................................................................................................. E–4
E.4.2 Insert Only ............................................................................................................................ E–4
E.4.3 Data Formats ......................................................................................................................... E–6
E.4.3.1 PCM-30 ............................................................................................................................. E–6
E.4.3.2 PCM-30C .......................................................................................................................... E–6
DMD-2050E Universal Satellite Modem Revision 2
Table of Contents MN-DMD2050E
xii
E.4.3.3 PCM-31 ............................................................................................................................. E–6
E.4.3.4 PCM-31C .......................................................................................................................... E–7
E.4.3.5 T1-D4/T1-D4-S ................................................................................................................. E–7
E.4.3.6 T1-ESF/T1-ESF-S ............................................................................................................. E–7
E.4.4 Systems with Multiple Destinations ..................................................................................... E–7
E.4.5 Drop and Insert Mapping ...................................................................................................... E–7
E.5 Configuring the Modem for Drop and Insert ........................................................................ E–10
E.5.1 Data Rate ............................................................................................................................. E–11
E.5.2 Operational Network Specification ..................................................................................... E–12
E.5.3 Terrestrial Framing - Drop Mode/Insert Mode ................................................................... E–12
E.5.3.1 Insert Terrestrial Frame Source ....................................................................................... E–13
E.5.4 D&I Sample Configurations and D&I Clock Setup Options .............................................. E–13
E.5.4.1 D&I Clock Setup Examples ............................................................................................ E–17
E.6 D&I Maps and Map Editing ................................................................................................... E–19
E.7 Efficient Drop and Insert Introduction .................................................................................. E–23
E.8 Prerequisite ............................................................................................................................... E–24
E.9 Efficient Drop and Insert Mode .............................................................................................. E–25
E.9.1 Calculating the Required Satellite Bandwidth .................................................................... E–26
E.9.2 Calculating the Basic Efficient D&I Rate ........................................................................... E–26
E.9.3 Calculating the Efficient D&I Rate with E1 Signaling ....................................................... E–26
E.9.4 Calculating the Efficient D&I Rate with Enhanced Asynchronous Overhead ................... E–27
APPENDIX F. TCP/IP ETHERNET SETUP ........................................................................... F–1
F.1 Introduction ................................................................................................................................. F–1
F.2 TCP/IP Network Configuration ................................................................................................ F–1
F.3 Network Configuration Summary ............................................................................................. F–3
F.4 Ethernet Test ............................................................................................................................... F–4
F.4.1 Connecting the Modem Ethernet Cable to a Network Link .................................................. F–4
F.4.2 Connecting the Modem Ethernet Cable Directly to a Computer (without a Network) ......... F–4
F.5 Testing the Ethernet Connection using the Ping Program (Optional) ................................... F–7
APPENDIX G. AUPC OPERATION ...................................................................................... G–1
G.1 Automatic Uplink Power Control (AUPC Operation) ........................................................... G–1
G.1.1
Radyne AUPC ...................................................................................................................... G–1
G.1.2 EF AUPC ............................................................................................................................. G–2
G.1.3 Near Side AUPC .................................................................................................................. G–2
G.1.4 EBEM AUPC ....................................................................................................................... G–3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342