300VA 500VA
Gneral Sku ULT33061 ULT33062
Backup Time 4-6 minutes (a PC with 15” CRT monitor)
8-12 minutes
(
a PC with 15” LCD monitor
)
7-9 minutes (a PC with 15” CRT monitor)
14-16 minutes
(
a PC with 15” LCD monitor
)
Net Weight Kg (lbs) 1.9
(
4.2
)
2.58
(
5.67
)
Digital Display No No
Output Watts 150 250
UPS Capacity 300VA 500VA
No. of Sockets St
y
le A UPSx3
,
B
yp
assx3 St
y
le A UPSx3
,
B
yp
assx3
Voltage (Battery) Simulated sine wave at 120V +/- 5% Simulated sine wave at 120V +/- 5%
Frequency (Battery) 50 or 60Hz +/- 0.3Hz 50 or 60Hz +/- 0.3Hz
Transfer Time 2-4 milliseconds
,
includin
g
detection time 2-4 milliseconds
,
includin
g
detection time
Input Voltage (Single Phase) 120V +15%/-20% at line in
p
ut 120V +15%/-20% at line in
p
ut
Frequency 50 or 60Hz +/- 10%
(
auto sensin
g)
50 or 60Hz +/- 10%
(
auto sensin
g)
Protection Unit Input Circuit breaker for overload & short circuit
p
rotection Circuit breaker for overload & short circuit
p
rotection
Overload Protection AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously.
Backup Mode: If load exceeds 110% of nominal for 1
second, UPS shuts down automatically.
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automaticall
y
.
Short Circuit UPS out
p
ut shuts off immediatel
y
UPS out
p
ut shuts off immediatel
y
Surge Protection 1140 Joules
,
2ms 1140 Joules
,
2ms
Battery Type Sealed, maintenance-free lead acid battery, with 3-6
y
ears t
yp
ical lifetime
Sealed, maintenance-free lead acid battery, with 3-6
y
ears t
yp
ical lifetime
Typical Recharge Time 4 hours
(
to 90% of full ca
p
acit
y)
6 hours
(
to 90% of full ca
p
acit
y)
Protection Automatic self-test, Over discharge protection, short
circuit
p
rotection b
y
fuse
Automatic self-test, Over discharge protection, short
circuit
p
rotection b
y
fuse
Interface USB Battery low detecting, UPS on/off scheduling AC
in
p
ut/out
p
ut
p
ower status dis
p
la
y
.
Battery low detecting, UPS on/off scheduling AC
in
p
ut/out
p
ut
p
ower status dis
p
la
y
.
Alarm Battery Backup Slow bee
p
in
g
sound ever
y
4 seconds Slow bee
p
in
g
sound ever
y
4 seconds
Battery Low Ra
p
id bee
p
in
g
sound ever
y
second Ra
p
id bee
p
in
g
sound ever
y
second
Abnormal Charge AC Mode: Ra
p
id bee
p
in
g
sound ever
y
0.5 second AC Mode: Ra
p
id bee
p
in
g
sound ever
y
0.5 second
Overload Continuous bee
p
in
g
sound Continuous bee
p
in
g
sound
Environment Ambient Operation 3,500 meters max. elevation, 0-95% humidity non-
condensin
g,
0-40?
3,500 meters max. elevation, 0-95% humidity non-
condensin
g,
0-40?
Audible Noise <40dBA
(
1 meter from surface
)
<40dBA
(
1 meter from surface
)
700VA 850VA
ULT33063 ULT33064
9-11 minutes (a PC with 15” CRT monitor)
17-19 minutes
(
a PC with 15” LCD monitor
)
16-20 minutes (a PC with 15” CRT monitor)
36-40 minutes
(
a PC with 15” LCD monitor
)
2.58(5.67) 4.1(9.1)
No No
350 425
700VA 850VA
St
y
le A UPSx3
,
B
yp
assx3 St
y
le A UPSx4
,
B
yp
assx4
Simulated sine wave at 120V +/- 5% Simulated sine wave at 120V +/- 5%
50 or 60Hz +/- 0.3Hz 50 or 60Hz +/- 0.3Hz
2-4 milliseconds
,
includin
g
detection time 2-4 milliseconds
,
includin
g
detection time
120V +15%/-20% at line in
p
ut 120V +15%/-20% at line in
p
ut
50 or 60Hz +/- 10%
(
auto sensin
g)
50 or 60Hz +/- 10%
(
auto sensin
g)
Circuit breaker for overload & short circuit
p
rotection Circuit breaker for overload & short circuit
p
rotection
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automaticall
y
.
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automaticall
y
.
UPS out
p
ut shuts off immediatel
y
UPS out
p
ut shuts off immediatel
y
1140 Joules, 2ms 1520 Joules, 2ms
Sealed, maintenance-free lead acid battery, with 3-6
y
ears t
yp
ical lifetime
Sealed, maintenance-free lead acid battery, with 3-6
y
ears t
yp
ical lifetime
6 hours (to 90% of full capacity) 6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit
p
rotection b
y
fuse
Automatic self-test, Over discharge protection, short
circuit
p
rotection b
y
fuse
Battery low detecting, UPS on/off scheduling AC
in
p
ut/out
p
ut
p
ower status dis
p
la
y
.
Battery low detecting, UPS on/off scheduling AC
in
p
ut/out
p
ut
p
ower status dis
p
la
y
.
Slow bee
p
in
g
sound ever
y
4 seconds Slow bee
p
in
g
sound ever
y
4 seconds
Ra
p
id bee
p
in
g
sound ever
y
second Ra
p
id bee
p
in
g
sound ever
y
second
AC Mode: Ra
p
id bee
p
in
g
sound ever
y
0.5 second AC Mode: Ra
p
id bee
p
in
g
sound ever
y
0.5 second
Continuous bee
p
in
g
sound Continuous bee
p
in
g
sound
3,500 meters max. elevation, 0-95% humidity non-
condensin
g,
0-40?
3,500 meters max. elevation, 0-95% humidity non-
condensin
g,
0-40?
<40dBA
(
1 meter from surface
)
<40dBA
(
1 meter from surface
)
Features
- AVR (Automatic Voltage Regulation)
- Fully Digitized Microprocessor Controlled
- Protects up to 4 Devices at Once
- Energy Saving Function (UPS Green Mode)
- 50/60Hz Frequency Auto Sensing and Selection
- USB Communication Port
- Advanced Battery Management (ABM Technology)
Includes
UPS Monitoring
Software
1-800-830-0051
www.ultraproducts.com
  • Page 1 1

Ultra Products ULT33062 User manual

Category
Power supply units
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI