3.5 GAS CONNECTION (if provided for)
Install a pressure reducer upstream from the gas system. When operating on
gas, the machine emits combustion fumes directly into the surroundings where
it is being used. Therefore, gas-powered machines must not be installed in
rooms with a volume of less than 12 m
3
, as described in standards UNI 7129
and UNI 7131.
On the pipe works upstream from the machine, a cut-off cock must be installed.
If flexible hoses rather than stiff pipes are used for connections, they must be
compliant with standard UNI 7140. These hoses must not be more than one
metre long, and they must be firmly attached to the hose connection with a safety
clamp (UNI 7141). They must not be placed near potential heat sources, they
must not reach a temperature greater than 50°C, they must not be subjected
to traction or twisting stress, and they must not have any kinks in them. It must
be possible to inspect them along their entire length, and they must not come
into contact with sharp objects or sharp corners.
The machine is assembled with the methane gas nozzle already installed.
The nozzle for city gas or gas cylinders is provided. Check that the nozzle
is appropriate to the type of gas being used before lighting the burner. The
incoming gas pipe must be equipped with a cut-off cock near the machine (see
the provided gas diagram).
At the cock outlet there will as necessary be installed a flexible hose or a stiff
copper pipe. Pipe connections to the machine must be made in accordance with
current standards in the country of installation. If connection is made with a
flexible hose, first of all insert the hose into the gas safety hose connection.
If instead you would like to make a stiff connection, you can use a soft copper
pipe Ø6x8, equipped with a 1/4 gas nipple at the gas safety (remove the hose
connection first).
1. Hose connection tube
2. Gas ignition push button
3. Gas self-regulator
4. Gas safety
5. Nozzle
6. Burner
NOTE
To adjust the gas system, refer to chapter12.
The water in the boiler can be heated in various ways: only electrically (ma-
chines without gas system), only with gas (version ALE), with a combined
system of gas and electricity (machines with gas system).
6
5
3
2
4
1
WARNING
Always connect the motor pump cable before the machine power supply cable, in accordance with the diagram provided.
Failure to comply with the instructions given above may cause serious damage to the machine an/or to the motor pump
and will invalidate any guarantee. Carry out all electrical connections with the power supply disconnected.
3.4 ELECTRICAL CONNECTION
On the electrical mains, it is advisable to install a main protection switch (A)
Machine with INTERNAL MOTOR PUMP
Connect the power cable as set forth in the chapter “Electrical diagrams” (the cable has a
cross-section and number of wires based on the power and voltage of the machine).
Machine with EXTERNAL MOTOR PUMP
1) Connect the cable to the motor pump (with lesser cross section) to the connector
as shown in the diagram shown alongside.
2) Connect the machine power cable (with greater cross section) as set forth in the
chapter “Electrical diagrams”.
C
B
M
GV
B
M
GV
MP
C Motor pump power cable
MP Motor pump terminal
B Blue
M Brown
GV Yellow-green