Rohde&Schwarz SGT100A User manual

  • Hello! I'm your chat assistant. I've reviewed the user manual for the Rohde & Schwarz SGT100A signal generator. This document provides detailed instructions on operating the instrument, focusing on features such as generating IQ-modulated signals, using the ARB baseband generator and playbacking external modulation signals. I'm ready to answer your questions about the SGT100A and its capabilities.
  • What is the intended use of the R&S SGT100A?
    What kind of signals can the R&S SGT100A generate?
    What are some key options for the R&S SGT100A?
R&S®SGT100A
SGMA Vector RF Source
User Manual
1176867402
Version 12
(;ÚäØ2)
This manual describes the following R&S®SGT100A, stock no. 1419.4501.02 and its options.
R&S®SGT-B1, Reference Oscillator OCXO (1419.5608.02)
R&S®SGT-B88, Extension Unit (1419.8207.02)
R&S®SGT-KB106, Frequency extension to 6 GHz (1419.5708.02)
R&S®SGT-K16, Diff. analog I/Q outputs
R&S®SGT-K18, Digital baseband connectivity (1419.6240.02)
R&S®SGT-K22, Pulse modulation (1416.6279.02)
R&S®SGT-K62, Additive White Gaussian Noise (AWGN) (1419.6304.02)
R&S®SGT-K90, Phase Coherent Input/Output (1419.6333.02)
R&S®SGT-K510, ARB baseband generator (1419.7500.02)
R&S®SGT-K511/512, ARB memory extension (1419.6362.02/1419.6391.02)
R&S®SGT-K521/522, ARB bandwidth extension (1419.6247.02/1419.6456.02)
R&S®SGT-K523, Baseband Extension to 240 MHz (1419.7952.02)
R&S®SGT-K540, Envelope Tracking (1419.7800.02)
R&S®SGT-K541, AM/AM AM/PM Predistortion (1419.7852.02)
R&S®SGT-K543, Envelope ARB (1419.7900.02)
R&S®SGT-K548, Crest Factor Reduction (1419.8471.02)
R&S®SGT-K200, Waveform package for signals from R&S®WinIQSIM2TM (1419.5850.71/72/75)
R&S®SGT-K110/-K111/-K112-/K113/-K114/-K115-/K116/-K117/-K118/-K119/-K120/-K121/-K122/-K151,
Waveform Libraries for ARB Generator
This manual describes firmware version FW 5.00.232.xx and later of the R&S®SGT100A.
© 2023 Rohde & Schwarz GmbH & Co. KG
Muehldorfstr. 15, 81671 Muenchen, Germany
Phone: +49 89 41 29 - 0
Internet: www.rohde-schwarz.com
Subject to change – data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
CDMA2000® is a registered trademark of the Telecommunications Industry Association (TIA-USA).
MIPI® marks and logos are service marks owned by MIPI Alliance, Inc. and any use of such marks by Rohde & Schwarz is under
license.
All other trademarks are the properties of their respective owners.
1176.8674.02 | Version 12 | R&S®SGT100A
Throughout this manual, products from Rohde & Schwarz are indicated without the ® symbol , e.g. R&S®SGT is indicated as
R&S SGT.
Contents
R&S®SGT100A
3User Manual 1176.8674.02 ─ 12
Contents
1 Safety and regulatory information......................................................11
1.1 Safety instructions...................................................................................................... 11
1.2 Labels on R&S SGT.................................................................................................... 13
1.3 Warning messages in the documentation................................................................ 14
1.4 Korea certification class A......................................................................................... 14
2 Welcome............................................................................................... 15
2.1 Key features.................................................................................................................15
2.2 What's new...................................................................................................................15
2.3 Documentation overview............................................................................................16
2.3.1 User manual and help................................................................................................... 16
2.3.2 Data sheets and brochures........................................................................................... 16
2.3.3 Release notes and open source acknowledgment (OSA)............................................ 16
2.3.4 Application notes, application cards, white papers, etc.................................................16
2.4 Typographical conventions........................................................................................17
2.5 Notes on screenshots.................................................................................................17
3 Getting started......................................................................................18
3.1 Preparing for use........................................................................................................ 18
3.1.1 Lifting and carrying........................................................................................................18
3.1.2 Unpacking and checking............................................................................................... 18
3.1.3 Choosing the operating site.......................................................................................... 18
3.1.4 Setting up the R&S SGT............................................................................................... 19
3.1.5 Considerations for test setup........................................................................................ 20
3.1.6 Connecting to power..................................................................................................... 21
3.1.7 Connecting to LAN........................................................................................................ 22
3.1.8 Connecting to RF 50Ω...................................................................................................22
3.1.9 Connecting to non-screwable connectors..................................................................... 23
3.1.10 Switching on or off.........................................................................................................24
3.1.11 Checking default settings.............................................................................................. 26
3.1.12 Working with Linux operating system............................................................................26
3.1.13 Connecting an external PC and devices....................................................................... 26
3.2 Instrument tour............................................................................................................32
Contents
R&S®SGT100A
4User Manual 1176.8674.02 ─ 12
3.2.1 Front panel tour.............................................................................................................33
3.2.2 Rear panel tour............................................................................................................. 35
3.2.3 Connector extension unit (R&S SGT-B88)....................................................................37
3.3 Trying out the instrument...........................................................................................39
3.3.1 How to generate a CW signal....................................................................................... 39
3.3.2 How to create and load a waveform file........................................................................ 41
3.4 Instrument control...................................................................................................... 45
3.4.1 Manual operation via R&S SGMA-GUI......................................................................... 45
4 System overview..................................................................................49
4.1 Setups for instrument control....................................................................................49
4.1.1 Manual operation from the R&S SGMA-GUI.................................................................49
4.1.2 Remote control from a controller...................................................................................49
4.2 Managing files on the R&S SGT................................................................................ 50
5 Understanding R&S SGMA-GUI..........................................................53
5.1 Operating menu and toolbar...................................................................................... 53
5.1.1 File menu...................................................................................................................... 54
5.1.2 Setup menu...................................................................................................................55
5.1.3 Help menu.....................................................................................................................64
5.2 Info dialog and messages in the info bar................................................................. 64
5.2.1 Info dialog......................................................................................................................64
5.2.2 Understanding the messages in the info bar.................................................................65
5.3 Main panel....................................................................................................................66
5.4 Block diagram............................................................................................................. 69
5.4.1 Function blocks in the block diagram............................................................................ 69
5.4.2 Signal flow and input/output symbols in the block diagram...........................................70
5.5 Working with R&S SGMA-GUI....................................................................................70
5.5.1 Saving and loading settings.......................................................................................... 70
5.5.2 Managing instruments with R&S SGMA-GUI................................................................71
5.5.3 Finding out the default hostname of the instrument...................................................... 74
5.5.4 Bidirectional instrument identification............................................................................74
5.5.5 Managing messages in the info dialog..........................................................................75
5.6 Remote control of R&S SGMA-GUI........................................................................... 76
5.6.1 Programming examples................................................................................................ 77
Contents
R&S®SGT100A
5User Manual 1176.8674.02 ─ 12
5.6.2 R&S SGMA-GUI commands......................................................................................... 79
5.6.3 List of R&S SGMA-GUI commands.............................................................................. 84
6 Signal generator settings....................................................................85
6.1 Baseband..................................................................................................................... 85
6.1.1 System configuration.....................................................................................................85
6.1.2 ARB...............................................................................................................................87
6.1.3 Trigger, marker and clock settings.............................................................................. 121
6.1.4 ARB offsets................................................................................................................. 135
6.1.5 Crest factor reduction..................................................................................................135
6.2 Additive white Gaussian noise (AWGN) - noise generator................................... 141
6.2.1 About the AWGN generator........................................................................................ 141
6.2.2 AWGN settings............................................................................................................143
6.3 I/Q modulation and impairment settings................................................................ 150
6.3.1 I/Q modulation.............................................................................................................150
6.3.2 Impairments................................................................................................................ 151
6.3.3 I/Q modulator settings................................................................................................. 153
6.4 I/Q analog output settings........................................................................................160
6.4.1 General analog I/Q output settings............................................................................. 161
6.5 Generation of envelope tracking signals................................................................165
6.5.1 Required options......................................................................................................... 165
6.5.2 About the envelope tracking........................................................................................165
6.5.3 General RF envelope settings.....................................................................................176
6.5.4 Envelope settings........................................................................................................184
6.5.5 Shaping settings..........................................................................................................186
6.5.6 Edit I/Q envelope shape settings................................................................................ 194
6.5.7 Polynomial coefficients settings.................................................................................. 196
6.6 Applying digital predistortion.................................................................................. 198
6.6.1 Required options......................................................................................................... 198
6.6.2 About digital predistortion............................................................................................198
6.6.3 Digital predistortions AM/AM and AM/PM settings......................................................203
6.7 RF settings.................................................................................................................216
6.7.1 Overview of RF signal................................................................................................. 216
6.7.2 Operation mode.......................................................................................................... 217
Contents
R&S®SGT100A
6User Manual 1176.8674.02 ─ 12
6.7.3 Frequency / phase...................................................................................................... 217
6.7.4 Local oscillator (LO) coupling......................................................................................219
6.7.5 Reference oscillator.................................................................................................... 221
6.7.6 RF level settings..........................................................................................................224
6.7.7 Using power sensors...................................................................................................242
6.7.8 Pulse modulation.........................................................................................................255
6.8 Connectors................................................................................................................ 260
6.9 External baseband signal - baseband input........................................................... 262
6.9.1 Important signal parameters....................................................................................... 263
6.9.2 BB input block............................................................................................................. 264
7 General instrument settings and instrument setup........................270
7.1 Internal adjustments................................................................................................. 271
7.2 Hardware configuration............................................................................................273
7.3 Software and hardware options...............................................................................275
7.4 Manage license keys.................................................................................................276
7.5 Protection.................................................................................................................. 281
7.6 Security...................................................................................................................... 282
7.7 Network settings....................................................................................................... 286
7.8 Remote channels...................................................................................................... 289
7.9 LXI status................................................................................................................... 290
7.10 Emulations.................................................................................................................292
7.11 Date and time.............................................................................................................293
7.12 Factory preset........................................................................................................... 294
7.13 Standby and restart.................................................................................................. 295
7.14 Diagnostic and tests................................................................................................. 295
7.14.1 Selftest........................................................................................................................ 296
7.14.2 Connector test.............................................................................................................297
7.14.3 Keyboard tests............................................................................................................ 297
7.14.4 Power servoing test.....................................................................................................298
7.14.5 Simulation................................................................................................................... 299
7.15 External adjustments................................................................................................300
8 Performing configuration tasks........................................................302
8.1 How to configure the reference oscillator source................................................. 302
Contents
R&S®SGT100A
7User Manual 1176.8674.02 ─ 12
8.2 How to configure the local oscillator coupling source......................................... 303
8.3 How to define the signal at the REF/LO OUT connector....................................... 304
8.4 How to create and save ARB test signals...............................................................304
8.5 How to load and play waveform files...................................................................... 305
8.6 How to restore the LAN connection........................................................................ 306
8.7 How to switch between operating states................................................................306
8.8 How to use computer names................................................................................... 308
8.9 How to install a new firmware version on the instrument.....................................308
8.10 How to activate options............................................................................................ 311
9 Network operation and remote control............................................ 312
9.1 Remote control interfaces and protocols............................................................... 312
9.1.1 Remote control programs and libraries....................................................................... 313
9.1.2 LAN interface.............................................................................................................. 316
9.1.3 USB interface.............................................................................................................. 319
9.1.4 PCI Express interface................................................................................................. 319
9.1.5 GPIB interface (IEC/IEEE bus interface).....................................................................320
9.2 Starting a remote control session........................................................................... 321
9.2.1 How to find the VISA resource string.......................................................................... 321
9.2.2 Remote control over LAN using socket communication..............................................321
9.3 Advanced remote control using PCIe..................................................................... 322
9.3.1 Setting up a remote control connection via PCIe........................................................ 323
9.3.2 Downloading the drivers..............................................................................................323
9.3.3 Configuring the controller............................................................................................ 324
9.3.4 Connecting the controller and the instrument............................................................. 326
9.3.5 Enabling fast settings.................................................................................................. 327
9.4 Advanced remote control using fast socket.......................................................... 327
9.4.1 Setting up a remote control connection via fast socket...............................................328
9.4.2 Installing the protocol driver........................................................................................ 328
9.4.3 Enabling fast settings.................................................................................................. 329
9.5 Status reporting system........................................................................................... 329
9.5.1 Hierarchy of the status registers................................................................................. 329
9.5.2 Structure of a SCPI status register..............................................................................331
9.5.3 Status byte (STB) and service request enable register (SRE)....................................333
Contents
R&S®SGT100A
8User Manual 1176.8674.02 ─ 12
9.5.4 Event status register (ESR) and event status enable register (ESE)..........................334
9.5.5 Questionable status register (STATus:QUEStionable)................................................334
9.5.6 Operation status register (STATus:OPERation).......................................................... 335
9.5.7 Application of the status reporting system.................................................................. 335
9.5.8 Reset values of the status reporting system............................................................... 337
9.6 LXI configuration.......................................................................................................337
9.6.1 Default network settings..............................................................................................338
9.6.2 LXI browser settings....................................................................................................338
9.6.3 LAN configuration........................................................................................................339
9.6.4 How to record SCPI commands and messages via LXI............................................. 344
9.7 Monitoring remote control operation with R&S SGMA-GUI..................................345
10 Remote control commands...............................................................347
10.1 Common commands.................................................................................................348
10.2 General commands...................................................................................................353
10.3 Preset commands..................................................................................................... 354
10.4 CALibration subsystem............................................................................................354
10.5 CLOCk subsystem.................................................................................................... 357
10.6 CONNector subsystem............................................................................................. 358
10.7 DIAGnostic subsystem.............................................................................................360
10.8 FORMat Subsystem.................................................................................................. 361
10.9 MMEMory subsystem............................................................................................... 363
10.9.1 File naming conventions............................................................................................. 363
10.9.2 Extensions for user files.............................................................................................. 364
10.9.3 Examples.................................................................................................................... 364
10.9.4 Remote control commands......................................................................................... 365
10.10 Fast speed commands............................................................................................. 372
10.11 OUTPut subsystem................................................................................................... 373
10.12 SCONfiguration subsystem..................................................................................... 374
10.13 SENSe, READ, INITiate and SLISt subsystems......................................................375
10.14 SOURce subsystem.................................................................................................. 389
10.14.1 SOURce general commands...................................................................................... 390
10.14.2 SOURce:AWGN subsystem........................................................................................392
10.14.3 SOURce:BB subsystem general commands.............................................................. 400
Contents
R&S®SGT100A
9User Manual 1176.8674.02 ─ 12
10.14.4 SOURce:BB:ARB subsystem......................................................................................401
10.14.5 SOURce:BB:ARBitrary:CFR subsystem..................................................................... 449
10.14.6 SOURce:BBIN subsystem.......................................................................................... 455
10.14.7 SOURce:BB:IMPairment subsystem...........................................................................462
10.14.8 SOURce:BB:PROGress subsystem general commands............................................ 467
10.14.9 SOURce:BB:POWer subsystem................................................................................. 468
10.14.10 SOURce:CORRection subsystem...............................................................................469
10.14.11 SOURce:IQ subsystem............................................................................................... 478
10.14.12 SOURce:IQ:OUTPut subsystem................................................................................. 481
10.14.13 SOURce:IQ:OUTPut:ENVelope commands................................................................485
10.14.14 SOURce:IQ:DPD subsystem...................................................................................... 500
10.14.15 SOURce:PHASe subsystem....................................................................................... 515
10.14.16 SOURce:PULM Subsystem........................................................................................ 515
10.14.17 SOURce:POWer subsystem....................................................................................... 520
10.14.18 SOURce:ROSCillator subsystem................................................................................527
10.15 STATus subsystem....................................................................................................529
10.16 SYSTem subsystem.................................................................................................. 533
10.17 TEST subsystem....................................................................................................... 551
10.18 UNIT subsystem........................................................................................................ 552
10.19 List of R&S SGT commands.................................................................................... 553
11 Waveform and list format.................................................................. 565
11.1 Tag description..........................................................................................................565
11.2 How to manually create a waveform using tag file format....................................575
11.3 Editing waveform files.............................................................................................. 580
12 Error messages and troubleshooting.............................................. 581
12.1 Status information.................................................................................................... 581
12.2 Error messages......................................................................................................... 581
12.2.1 Volatile messages....................................................................................................... 581
12.2.2 Permanent messages................................................................................................. 582
12.3 SCPI-Error messages............................................................................................... 582
12.4 Device-Specific error messages..............................................................................582
12.5 Contacting customer support..................................................................................584
Contents
R&S®SGT100A
10User Manual 1176.8674.02 ─ 12
13 Transporting....................................................................................... 585
14 Maintenance, storage and disposal................................................. 586
14.1 Cleaning..................................................................................................................... 586
14.2 Storage.......................................................................................................................586
14.3 Disposal..................................................................................................................... 586
Annex.................................................................................................. 587
A Telnet program examples..................................................................587
Glossary: References........................................................................ 593
Index....................................................................................................594
Safety and regulatory information
R&S®SGT100A
11User Manual 1176.8674.02 ─ 12
1 Safety and regulatory information
The product documentation helps you use the product safely and efficiently. Follow the
instructions provided here and in the following chapters.
Intended use
The product is intended for the development, production and verification of electronic
components and devices in industrial, administrative, and laboratory environments.
Use the product only for its designated purpose. Observe the operating conditions and
performance limits stated in the data sheet.
Where do I find safety information?
Safety information is part of the product documentation. It warns you of potential dan-
gers and gives instructions on how to prevent personal injury or damage caused by
dangerous situations. Safety information is provided as follows:
In Chapter 1.1, "Safety instructions", on page 11. The same information is provi-
ded in many languages as printed "Safety Instructions". The printed "Safety
Instructions" are delivered with the product.
Throughout the documentation, safety instructions are provided when you need to
take care during setup or operation.
1.1 Safety instructions
Products from the Rohde & Schwarz group of companies are manufactured according
to the highest technical standards. To use the products safely, follow the instructions
provided here and in the product documentation. Keep the product documentation
nearby and offer it to other users.
Use the product only for its intended use and within its performance limits. Intended
use and limits are described in the product documentation such as the data sheet,
manuals and the printed "Safety Instructions". If you are unsure about the appropriate
use, contact Rohde & Schwarz customer service.
Using the product requires specialists or specially trained personnel. These users also
need sound knowledge of at least one of the languages in which the user interfaces
and the product documentation are available.
Reconfigure or adjust the product only as described in the product documentation or
the data sheet. Any other modifications can affect safety and are not permitted.
Never open the casing of the product. Only service personnel authorized by
Rohde & Schwarz are allowed to repair the product. If any part of the product is dam-
aged or broken, stop using the product. Contact Rohde & Schwarz customer service at
https://www.rohde-schwarz.com/support.
Safety instructions
Safety and regulatory information
R&S®SGT100A
12User Manual 1176.8674.02 ─ 12
Lifting and carrying the product
The maximum weight of the product is provided in the data sheet. You can lift or carry
the product by yourself, if you can manage the weight on your own. Alternatively, you
can use lifting or transporting equipment. Follow the instructions provided by the equip-
ment manufacturer.
Choosing the operating site
Only use the product indoors. The product casing is not waterproof. Water that enters
can electrically connect the casing with live parts, which can lead to electric shock,
serious personal injury or death if you touch the casing. If Rohde & Schwarz provides
accessories designed for your product, e.g. a carrying bag, you can use the product
outdoors.
Unless otherwise specified, you can operate the product up to an altitude of 2000 m
above sea level. The product is suitable for pollution degree 2 environments where
nonconductive contamination can occur. For more information on environmental condi-
tions such as ambient temperature and humidity, see the data sheet.
Setting up the product
Always place the product on a stable, flat and level surface with the bottom of the prod-
uct facing down. If the product is designed for different positions, secure the product so
that it cannot fall over.
If the product has foldable feet, always fold the feet completely in or out to ensure sta-
bility. The feet can collapse if they are not folded out completely or if the product is
moved without lifting it. The foldable feet are designed to carry the weight of the prod-
uct, but not an extra load.
If stacking is possible, keep in mind that a stack of products can fall over and cause
injury.
If you mount products in a rack, ensure that the rack has sufficient load capacity and
stability. Observe the specifications of the rack manufacturer. Always install the prod-
ucts from the bottom shelf to the top shelf so that the rack stands securely. Secure the
product so that it cannot fall off the rack.
Connecting to power
The product is an overvoltage category II product. Connect the product to a fixed
installation used to supply energy-consuming equipment such as household applian-
ces and similar loads. Keep in mind that electrically powered products have risks, such
as electric shock, fire, personal injury or even death. Replace parts that are relevant to
safety only by original parts, e.g. power cables or fuses.
Take the following measures for your safety:
Before switching on the product, ensure that the voltage and frequency indicated
on the product match the available power source. If the power adapter does not
adjust automatically, set the correct value and check the rating of the fuse.
Only use the power cable delivered with the product. It complies with country-spe-
cific safety requirements. Only insert the plug into an outlet with protective conduc-
tor terminal.
Safety instructions
Safety and regulatory information
R&S®SGT100A
13User Manual 1176.8674.02 ─ 12
Only use intact cables and route them carefully so that they cannot be damaged.
Check the power cables regularly to ensure that they are undamaged. Also ensure
that nobody can trip over loose cables.
If you connect the product to an external power supply, use the one delivered with
the product or recommended in the product documentation. The external power
supply must conform to the country-specific regulations.
Only connect the product to a power source with a fuse protection of maximum
20 A.
Ensure that you can disconnect the product from the power source at any time.
Pull the power plug to disconnect the product. The power plug must be easily
accessible. If the product is integrated into a system that does not meet these
requirements, provide an easily accessible circuit breaker at the system level.
Cleaning the product
Use a dry, lint-free cloth to clean the product. When cleaning, keep in mind that the
casing is not waterproof. Do not use liquid cleaning agents.
Meaning of safety labels
Safety labels on the product warn against potential hazards.
Potential hazard
Read the product documentation to avoid personal injury or product damage.
Electrical hazard
Indicates live parts. Risk of electric shock, fire, personal injury or even death.
Hot surface
Do not touch. Risk of skin burns. Risk of fire.
Protective conductor terminal
Connect this terminal to a grounded external conductor or to protective ground. This connec-
tion protects you against electric shock if an electric problem occurs.
1.2 Labels on R&S SGT
Labels on the casing inform about:
Personal safety, see "Connecting to power" on page 12.
Product and environment safety, see Table 1-1.
Identification of the product, see the serial number on the rear panel.
Table 1-1: Labels regarding R&S
SGT and environment safety
Labeling in line with EN 50419 for disposal of electrical and electronic equipment after the prod-
uct has come to the end of its service life. For more information, see Chapter 14, "Maintenance,
storage and disposal", on page 586.
Labels on R&S SGT
Safety and regulatory information
R&S®SGT100A
14User Manual 1176.8674.02 ─ 12
1.3 Warning messages in the documentation
A warning message points out a risk or danger that you need to be aware of. The sig-
nal word indicates the severity of the safety hazard and how likely it will occur if you do
not follow the safety precautions.
WARNING
Potentially hazardous situation. Could result in death or serious injury if not avoided.
CAUTION
Potentially hazardous situation. Could result in minor or moderate injury if not avoided.
NOTICE
Potential risks of damage. Could result in damage to the supported product or to other
property.
1.4 Korea certification class A
기기는 업무용(A) 전자파 적합기기로서 판매자 또는 사용자는 점을 주의하시기
바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다.
Korea certification class A
Welcome
R&S®SGT100A
15User Manual 1176.8674.02 ─ 12
2 Welcome
The R&S SGT is a signal generator intended for the generation of IQ-modulated sig-
nals and the playback and output of externally calculated modulation signals in the
form of waveforms.
Optimized for use in automated test equipment (ATE), the instrument offers fast settling
times in an exceptionally small form factor and low power consumption. The R&S SGT
is equipped with an active electronic step attenuator and can be equipped optionally
with a high stability reference oscillator.
2.1 Key features
The key features of the R&S SGT include the following:
Compact size and low power consumption
Remote connection via PCI Express, minimizing the setup time
Alternatively, LAN or USB connections available
Coherent LO input and output connectors, also usable as MIMO input/output and
phase coherent I/Q demodulation
Linux operating system
Graphical user interface R&S SGMA-GUI to set up and control one or more
R&S SGT instruments simultaneously from one remote computer, available for
Windows and Linux systems
2.2 What's new
This manual describes firmware version FW 5.00.232.xx and later of the
R&S®SGT100A.
Compared to the previous version, it provides the new features listed below:
Peak cancelation algorithm added for crest factor reduction (R&S SGT-K548):
Background information on the algorithm, see "Peak cancellation algorithm"
on page 136.
Algorithm settings, see "Algorithm" on page 138, "Cancellation Pulse Band-
width" on page 141 and "Transition Bandwidth" on page 141.
Instrument security settings for LAN interface and LAN services added:
LAN interface added, see "LAN Interface" on page 285.
Remote commands for LAN service states added, see Chapter 10.16, "SYS-
Tem subsystem", on page 533.
Editorial changes
What's new
Welcome
R&S®SGT100A
16User Manual 1176.8674.02 ─ 12
2.3 Documentation overview
This section provides an overview of the R&S SGT user documentation. Unless speci-
fied otherwise, you find the documents at:
www.rohde-schwarz.com/manual/sgt100a
2.3.1 User manual and help
Separate manuals for the base unit and the software options are provided for down-
load:
Base unit manual
Contains the description of all instrument modes and functions. It also provides an
introduction to remote control, a complete description of the remote control com-
mands with programming examples, and information on maintenance, instrument
interfaces and error messages. Includes the contents of the getting started manual.
Software option manual
Contains the description of the specific functions of an option. Basic information on
operating the R&S SGT is not included.
The contents of the user manuals are available as help in the R&S SGT. The help
offers quick, context-sensitive access to the complete information for the base unit and
the software options.
2.3.2 Data sheets and brochures
The data sheet contains the technical specifications of the R&S SGT. It also lists the
options and their order numbers and optional accessories.
The brochure provides an overview of the instrument and deals with the specific char-
acteristics.
See www.rohde-schwarz.com/brochure-datasheet/sgt100a
2.3.3 Release notes and open source acknowledgment (OSA)
The release notes list new features, improvements and known issues of the current
firmware version, and describe the firmware installation.
The open source acknowledgment document provides verbatim license texts of the
used open source software.
See www.rohde-schwarz.com/firmware/sgt100a
2.3.4 Application notes, application cards, white papers, etc.
These documents deal with special applications or background information on particu-
lar topics.
Documentation overview
Welcome
R&S®SGT100A
17User Manual 1176.8674.02 ─ 12
See www.rohde-schwarz.com/application/sgt100a.
2.4 Typographical conventions
The following text markers are used throughout this documentation:
Convention Description
"Graphical user interface ele-
ments"
All names of graphical user interface elements on the screen, such as
dialog boxes, menus, options, buttons, and softkeys are enclosed by
quotation marks.
[Keys] Key and knob names are enclosed by square brackets.
Filenames, commands,
program code
Filenames, commands, coding samples and screen output are distin-
guished by their font.
Input Input to be entered by the user is displayed in italics.
Links Links that you can click are displayed in blue font.
"References" References to other parts of the documentation are enclosed by quota-
tion marks.
2.5 Notes on screenshots
When describing the functions of the product, we use sample screenshots. These
screenshots are meant to illustrate as many as possible of the provided functions and
possible interdependencies between parameters. The shown values may not represent
realistic usage scenarios.
The screenshots usually show a fully equipped product, that is: with all options instal-
led. Thus, some functions shown in the screenshots may not be available in your par-
ticular product configuration.
Notes on screenshots
Getting started
R&S®SGT100A
18User Manual 1176.8674.02 ─ 12
3 Getting started
3.1 Preparing for use
Here, you can find basic information about setting up the product for the first time.
3.1.1 Lifting and carrying
See also "Lifting and carrying the product" on page 12.
Use the carrying handles at the side for lifting and carrying the R&S SGT.
The handles at the front are only for pushing and pulling the instrument when
mounting in a rack, see Chapter 3.1.4.2, "Mounting the R&S SGT in a rack",
on page 20.
3.1.2 Unpacking and checking
1. Unpack the R&S SGT carefully.
2. Retain the original packing material. Use it to protect the control elements and con-
nectors when transporting or shipping the R&S SGT later.
See also Chapter 13, "Transporting", on page 585.
3. Using the delivery notes, check the equipment for completeness.
4. Check the equipment for damage.
If the delivery is incomplete or equipment is damaged, contact Rohde & Schwarz.
3.1.3 Choosing the operating site
Specific operating conditions ensure proper operation and avoid damage to the prod-
uct and connected devices. For information on environmental conditions such as ambi-
ent temperature and humidity, see the data sheet.
For safety information, see "Choosing the operating site" on page 12.
Electromagnetic compatibility classes
The electromagnetic compatibility (EMC) class indicates where you can operate the
product. The EMC class of the product is given in the data sheet.
Class B equipment is suitable for use in:
Residential environments
Preparing for use
Getting started
R&S®SGT100A
19User Manual 1176.8674.02 ─ 12
Environments that are directly connected to a low-voltage supply network that
supplies residential buildings
Class A equipment is intended for use in industrial environments. It can cause
radio disturbances in residential environments due to possible conducted and radi-
ated disturbances. It is therefore not suitable for class B environments.
If class A equipment causes radio disturbances, take appropriate measures to
eliminate them.
3.1.4 Setting up the R&S SGT
See also:
"Setting up the product" on page 12
"Intended use" on page 11
3.1.4.1 Placing the R&S SGT on a bench top
To place the product on a bench top
1. Place the product on a stable, flat and level surface. Ensure that the surface can
support the weight of the product. For information on the weight, see the data
sheet.
2. WARNING! A stack of products can fall over and cause injury. Never stack more
than three products on top of each other. Instead, mount them in a rack.
Stack as follows:
If the products have foldable feet, fold them in completely.
It is best if all products have the same dimensions (width and length). If the
products have different dimensions, stack according to size and place the
smallest product on top.
Do not exceed the permissible total load placed on the product at the bottom of
the stack:
– 50 kg when stacking products of identical dimensions (left figure).
– 25 kg when stacking smaller products on top (middle figure).
Preparing for use
Getting started
R&S®SGT100A
20User Manual 1176.8674.02 ─ 12
Left = Stacked correctly, same dimensions
Middle = Stacked correctly, different dimensions
Right = Stacked incorrectly, too many products
3. NOTICE! Overheating can damage the product.
Prevent overheating as follows:
Keep a minimum distance of 10 cm between the fan openings of the product
and any object in the vicinity.
Do not place the product next to heat-generating equipment such as radiators
or other products.
3.1.4.2 Mounting the R&S SGT in a rack
To prepare the rack
1. Observe the requirements and instructions in "Setting up the product" on page 12.
2. NOTICE! Insufficient airflow can cause overheating and damage the product.
Design and implement an efficient ventilation concept for the rack.
To mount the R&S SGT in a rack
1. Use an adapter kit that fits the dimensions of the R&S SGT to prepare the instru-
ment for rack mounting.
a) Order the rack adapter kit designed for the R&S SGT. For the order number,
see data sheet.
b) Mount the adapter kit. Follow the assembly instructions provided with the
adapter kit.
2. Push the R&S SGT onto the shelf until the rack brackets fit closely to the rack.
3. Tighten all screws at the rack brackets with a tightening torque of 1.2 Nm to secure
the R&S SGT in the rack.
To unmount the R&S SGT from a rack
1. Loosen the screws at the rack brackets.
2. Remove the R&S SGT from the rack.
3. If placing the R&S SGT on a bench top again, unmount the adapter kit from the
R&S SGT. Follow the instructions provided with the adapter kit.
3.1.5 Considerations for test setup
Cable selection and electromagnetic interference (EMI)
Electromagnetic interference (EMI) can affect the measurement results.
Preparing for use
/