Kistler 4260A Owner's manual

Type
Owner's manual

This manual is also suitable for

Instruction Manual
Piezoresistive Pressure
Sensors
Types 4260A…
4262A…
4264A…
Piezoresistive Pressure Sensors
Types 4260A…
4262A…
4264A
1 Description
Type 4260/62/64A series uses a piezoresistive sensing
element that changes resistance with changing pressure.
The change in resistance from a four arm Wheatstone
bridge is conditioned and an electrical signal proportional
to pressure is supplied in either mV, V or mA outputs,
depending upon model type.
2 Pressure Media
The pressure cavity for a gauge, sealed gauge or ab-
solute sensor is constructed of a hermetically sealed
assembly of 316L Stainless Steel. Fluids and gases must
be compatible with 316L Stainless Steel.
For differential sensors, the reference port material is 316
SST, Gold plated Kovar, Silicon, Pyrex and Epoxy.
3 Mounting
Type 4260/62/64A series is available with many types
of pressure ports. Please pay attention to the following:
• Ensure all sealing surfaces are clean, free of debris and
indents.
Do not exceed a tightening torque of 11.1 lbf-ft
(15 Nm).
Refer to and follow any practices specified in the
selected pressure ports standard.
Some sensors are supplied with an elastomeric seal
for customer convenience. Refer to the pressure port
standard for use or consult with the factory.
2
4 Rated Pressure
Do not exceed the stated working pressure (marked
as Max WP on sensor body). Take particular care with
applications where pressure “spikes” or “hammers”
may be present. Type 4260/62/64A series has high
overpressure and pressure transient protection but the
energy content of spikes can be particularly damaging.
Please consult the factory with questions.
5 Electrical Output
Refer to the data sheet for the electrical output options
and wiring configurations. The output and wiring
configurations are also marked on the body of the sensor
and the calibration data sheet, if this option is ordered.
6 Sensor Excitation
Refer to the data sheet for the range of power supply
voltages depending upon electrical output. The sensor
excitation is also marked on the body of the sensor.
7 Hazardous Area Installation
Some models of Type 4260/62/64A series are approved
for use in Hazardous Area locations. It is imperative that
the installation instructions for the particular Hazardous
area certification are followed.
8 General Safety
Trapped pressure is a potential safety hazard. Never
remove or install a pressure sensor from a pressurized
pipe or vessel.
The transducer working detail will include the Hazardous
area marking if it has been ordered. Refer to data sheet
for ordering code options. The relevant declaration of
conformity’s are contained within this booklet. Transducers
without Hazardous area marking are not allowed to be used
in Hazardous areas.
3
Hazardous Area Installation
Installation and Handling for Safe Use: The 426XA Series, Zone 0
Intrinsically Safe and Zone 2 Non-Incendive, pressure sensors comply
with the Essential Health and Safety requirements specified in EC
Directive 2014/34/EU. Installation must be performed in compliance
with the Electrical Safety Standards applicable in the country of
end use. The wiring terminations are marked on the sensor body.
Completed sensors will withstand a test voltage of 500 VAC applied
between all input connections and frame for 1 minute. For installation
in Canada and North America refer to control drawing 100.307.971
enclosed in this booklet.
Cleaning: The sensor may be cleaned using a clean “lint free”
cloth to remove surface debris. Ensure all electrical connections and
pressure sealing surfaces remain free from debris. Exposed parts are
Stainless Steel except for plastic plugs and cables.
Repair: The 426XA Intrinsically safe and non-incendive sensors are
sealed at the factory and are not intended for site adjustment or
repair by the end user.
Cable: Where used the cable shield is isolated from the sensor frame
and the rated temperature is 80°C (175°F).
Purpose: The sensors detailed in Table 2 are intended for use in
Zone0, Intrinsically Safe, Hazardous (Classified) Areas with a suitable
Zener barrier (e.g. Kistler Type 5252A1, 5252A2 or equivalent third
party products) matching the entity parameters detailed in Table 1,
by output version. For Zone 2 the same entity parameters apply but
use of a Zener barrier is not required. Refer to installation diagram
for layout details.
Description: The 426XA Series Pressure Sensors provide either a
pressure to voltage or pressure to current conversion. Table 1 details
the output version and entity parameters with supply voltage limits.
Output
Version
426XA
Option
Ci
(nF)
Li
(uH)
Ii
(mA)
Pmax
(W)
Vs
max
(VDC)
Max
Allowable
Capacitance
in Cable
(nF)
Max
Allowable
Inductance
in Cable
(uH)
mV A 5 0 180 1 15 9.7 30
4-20 mA C 31 2 180 1 28 9.7 30
Voltage see Table
3 and 4
20 4 180 1 42 9.7 30
Table 1: Entity parameters by version
4
5
Model No.: The full 16 character number marked on the sensor
describes the variant precisely as shown in Table 2.
426xA XXX X X X X XX X X
Absolute = 0
Gauge/Relative = 2
Differential = 4
Pressure Range Code
Pressure Units
Output Table 1
Pressure Fitting
Electrical Connector
Cable Length
Wire Code
Standard Zone 0 = A
Standard Zone 2 = B
Table 2: Sensor variants
Product Marking:
KISTLER
426XA XXX X X X X XX X A-B (A Zone 0 or B Zone 2)
S/N XXXXXXX/ 20XX (Serial Number and Date Manufactured)
Pressure XXXX
(-40°C ≤ Ta ≤ 80°C) / (-40°F ≤ Ta ≤ 175°F)
ATEX Intrinsically Safe: Baseefa08ATEX0021
Zone 0: Ex ia IIC T4 Ga 0598 II 1G
ATEX Non-incendive: Baseefa08ATEX0022
Zone 2: Ex nA IIC T4 Gc II 3G
North America/Canada:
Certificate 2053869 single seal
Class I/ Division 1 & Class I/ Zone 0 Intrinsically Safe:
Class I, Division 1, Groups A,B,C,D
Ex ia IIC T4 / AEx ia IIC T4
Class I/ Division 2 & Class I/ Zone 2 Non-incendive:
Class I, Division 2, Groups A,B,C,D
Ex nL IIC T4 / AEx nA IIC T4
NY 14228, USA
P
mV
Signal
Power
DAQ or
Sensor interface
PRT 426xA
Hazard area
(Zone 2)
Safe area
PRT 426xA with mV output
Millivolt Version: These are 4-wire sensors with no active compo-
nents, providing an output voltage of 5mV/V or 10 mV/V, depen-
dent on pressure range. The millivolt level signal is proportional to
pressure input.
The VS voltage supply limits are defined in Table 1.
6
P
mV
Signal
Power
DAQ or
Sensor interface
PRT 426xA
Hazard area
(Zone 0)
Safe area
IS
IS Protective Earth
2
1
3
4
5252A1
2
1
3
4
5252A1
2
1
3
4
5252A1
5252A1 (x3)
Zener Barriers
P
mA
Signal
DAQ or
Sensor interface
PRT 424xA
Hazard area
(Zone 2)
Safe area
R
L
PRT 426xA with mA output
4-20 mA Version: This is a 2-wire loop powered sensor providing
a pressure to current conversion. The sensor output signal may be
installed with a “load” resistor for measurement of the voltage across
the resistor or with a mA current meter in the loop.
Resistor RL selection is limited by the minimum required voltage (VS)
at the terminals of the sensor. Where: VS = (0.02 x RL) + 9 VDC.
The VS voltage supply limits are defined in Table 1.
7
P
mA
Signal
DAQ or
Sensor interface
PRT 426xA
Hazard area
(Zone 0)
Safe area
R
L
IS
IS Protective Earth
2
1
3
4
5252A2
5252A2 (x1)
Zener Barriers
P
V
Signal
Power
DAQ or
Sensor interface
PRT 426xA
Hazard area
(Zone 2)
Safe area
PRT 426xA with V output (4-wire)
Voltage Version: These are 4-wire low power sensors providing a
pressure to voltage conversion. The specific option codes are listed
in Table 3.
Code Output Type
R 0 to 10 VDC, 4-wire
U -5 to +5 VDC, 4-wire
X 0 to 5 VDC, 4-wire
Table 3: Option codes (4-wire)
The voltage across the positive output and negative output (4-wire),
can be directly measured using a high impedance voltmeter and the
signal is proportional to pressure input.
The VS supply limits are defined in Table 1.
8
P
V
Signal
Power
DAQ or
Sensor interface
PRT 426xA
Hazard area
(Zone 0)
Safe area
IS
IS Protective Earth
2
1
3
4
5252A2
2
1
3
4
5252A2
2
1
3
4
5252A2
5252A2 (x3)
Zener Barriers
9
PRT 426xA with V output (3-wire)
Voltage Version: These are 3-wire low power sensors providing a
pressure to voltage conversion. The specific option codes are listed
in Table 4.
Code Output Type
F 1 to 6 VDC, 3-wire
I 0.5 to 4.5 VDC, 3-wire
L 0.1 to 5 VDC, 3-wire
Table 4: Option codes (3-wire)
The voltage across the positive output and negative output/negative
supply (3-wire), can be directly measured using a high impedance
voltmeter and the signal is proportional to pressure input.
For 3-wire sensors the negative supply and negative output are
connected internally. The VS supply limits are defined in Table 1.
P
V
Signal
Power
DAQ or
Sensor interface
PRT 426xA
Hazard area
(Zone 2)
Safe area
P
V
Signal
Power
DAQ or
Sensor interface
PRT 426xA
Hazard area
(Zone 0)
Safe area
IS
IS Protective Earth
2
1
3
4
5252A2
2
1
3
4
5252A2
5252A2 (x2)
Zener Barriers
1 / 1 www.kistler.com
200.009.645 - d Approved: 14-Apr-2020
EU Declaration of Conformity
EU-Konformitätserklärung
Déclaration UE de conformité
The manufacturer / Der Hersteller / Le Fabricant:
Kistler Instrument Corporation, 75 John Glenn Drive, Amherst, NY 14228 USA
hereby declares that the product / erklärt hiermit, dass das Produkt / déclare que le présente produit:
Name / Name / Nom Piezoresistive Pressure Transducer
Type / Typ / Type 4260A/4262A/4264A xx x x x x xxx x 0/1/2 Series
Modules / Module / Modules none / keine / sans
Options / Optionen / Options all / alle / toutes
complies with the following provisions of directives / die folgenden Bestimmungen der Richtlinien erfüllt /
est conforme aux dispositions suivantes des directives:
2014/30/EU (EMC / EMV / EMC)
2011/65/EU (ROHS)
2014/68/EU (PED)
The following harmonised standards were applied / Folgende harmonisierte Normen wurden angewandt /
Les normes harmonisées suivantes furent appliquées:
EMC Emission / EMV Störaussendung / Emission EMC
CISPR11:2009+A1:2010/ EN55011:2009+A1:2010, Class A Group 1
EMC Immunity / EMV Störfestigkeit / Immunité EMC
EN 61326-1:2013
Pressure Equipment / Druckausrüstung / Équipement sous pression:
Module A, Category 1 Pressure Accessory / Modul A, Zubehör der Kategorie 1 / Module A, accessoire de
pression de catégorie 1
SAE J1644 (see operating instructions / siehe Betriebsanleitung / voir notice d’emploi)
Kistler Instrument Corp.
Amherst, NY August 2018
i.V. Peter C. Tack,
Engineering Di rector
10
1 / 1 www.kistler.com
200.014.716 - g Approved: 14-Apr-2020
EU Declaration of Conformity
EU-Konformitätserklärung
Déclaration UE de conformi
The manufacturer / Der Hersteller / Le Fabricant:
Kistler Instrument Corporation, 75 John Glenn Drive, Amherst, NY 14228 USA
hereby declares that the product / erklärt hiermit, dass das Produkt / déclare que le présente produit:
Name / Name / Nom Piezoresistive Pressure Transducer
Type / Typ / Type 4260A/4262A/4264A xxx x x x xxx x A Series
Modules / Module / Modules none / keine / sans
Options / Optionen / Options all / alle / toutes
complies with the following provisions of directives / die folgenden Bestimmungen der Richtlinien erfüllt /
est conforme aux dispositions suivantes des directives:
2014/30/EU (EMC / EMV / EMC)
2011/65/EU (ROHS)
2014/68/EU (PED)
2014/34/EU (ATEX), Annex II, Category 1
The following harmonised standards were applied / Folgende harmonisierte Normen wurden angewandt /
Les normes harmonisées suivantes furent appliquées:
EMC Emission / EMV Störaussendung / Emission EMC
CISPR11:2009+A1:2010/EN55011:2009+A1:2010, Class A Group 1
EMC Immunity / EMV Störfestigkeit / Immunité EMC
EN 61326-1:2013
Pressure Equipment / Druckausrüstung / Équipement sous pression:
Module A, Category 1 Pressure Accessory / Modul A, Zuber der Kategorie 1 / Module A,
accessoire de pression de catégorie 1
SAE J1644 (see operating instructions / siehe Betriebsanleitung / voir notice d’emploi)
Hazardous Area Equipment / Équipement de zone dangereuse / Gefahrenbereich:
ATEX Zone 0, Equipment Group II, Category 1G (Ex ia IIC T4 Ga)
EN 60079-0: 2012+A11: 2013, EN60079-11: 2012
Notified Body: EU Type Examination certificate Baseefa08ATEX0021 was released by:
SGS Fimko Oy, Särkiniementie 3, P.O. Box 30, FI-00211, Helsinki, Finland (EU Notified Body Number: 0598)
Kistler Instrument Corp.
Amherst, NY April 2019
i.V. Peter C. Tack,
Engineering Di rector
i.V. Peter C. Tack,
ATEX Regulatory Speciali st (Certification Engineer)
11
1 / 1 www.kistler.com
200.014.717 - g Approved: 14-Apr-2020
EU Declaration of Conformity
EU-Konformitätserklärung
Déclaration UE de conformi
The manufacturer / Der Hersteller / Le Fabricant:
Kistler Instrument Corporation, 75 John Glenn Drive, Amherst, NY 14228 USA
hereby declares that the product / erklärt hiermit, dass das Produkt / déclare que le présente produit:
Name / Name / Nom Piezoresistive Pressure Transducer
Type / Typ / Type 4260A/4262A/4264A xxx x x x xxx x B Series
Modules / Module / Modules none / keine / sans
Options / Optionen / Options all / alle / toutes
complies with the following provisions of directives / die folgenden Bestimmungen der Richtlinien erfüllt /
est conforme aux dispositions suivantes des directives:
2014/30/EU (EMC / EMV / EMC)
2011/65/EU (ROHS)
2014/68/EU (PED)
2014/34/EU (ATEX), Annex II, Category 3
The following harmonised standards were applied / Folgende harmonisierte Normen wurden angewandt /
Les normes harmonisées suivantes furent appliquées:
EMC Emission / EMV Störaussendung / Emission EMC
CISPR11:2009+A1:2010/EN55011:2009+A1:2010, Class A Group 1
EMC Immunity / EMV Störfestigkeit / Immunité EMC
EN 61326-1:2013
Pressure Equipment / Druckausrüstung / Équipement sous pression:
Module A, Category 1 Pressure Accessory / Modul A, Zuber der Kategorie 1 / Module A,
accessoire de pression de catégorie 1
SAE J1644 (see operating instructions / siehe Betriebsanleitung / voir notice d’emploi)
Hazardous Area Equipment / Équipement de zone dangereuse / Gefahrenbereich:
ATEX Zone 2, Equipment Group II, Category 3G (Ex nA IIC T4 Gc)
EN 60079-0: 2012+A11: 2013, EN60079-15: 2010
Notified Body: Type Examination certificate Baseefa08ATEX0022 was released by:
SGS Fimko Oy, Särkiniementie 3, P.O. Box 30, FI-00211, Helsinki, Finland (EU Notified Body Number: 0598)
Kistler Instrument Corp.
Amherst, NY April 2019
i.V. Peter C. Tack,
Engineering Di rector
i.V. Peter C. Tack,
ATEX Regulatory Speciali st (Certification Engineer)
12
13
Control drawing 100.307.971, for installation in Canada and North America
± 1 / 64
ASME Y 14.5 M
±.01
±.005
*=KISTLER-Standard
X°±2°
.XXX.XX
Tolerance
Fractions
Angle
Dimension
Standard tolerances
CODE IDENT 58679
Unless otherwise specified:
Dimensions are in inches
Finish:
Remove all burrs and break
sharp edges 0.005 Max.
NOTES:
1. THE INTRINSIC SAFETY ENTITY CONCEPT ALLOWS THE INTERCONNECTION OF THE TWO INTRINSICALLY SAFE DEVICES APPROVED
BY CSA GROUP WITH ENTITY PARAMETERS NOT SPECIFICALLY EXAMINED IN COMBINATION AS A SYSTEM WHEN:
Uo OR Voc
Ui OR Vmax; Io OR Isc
Ii OR Imax; Po OR Pmax
Pi OR Pmax; Co OR Ca
Ci; Lo OR La
Li.
2. CONTROL EQUIPMENT CONNECTED TO THE ASSOCIATED APPARATUS MUST NOT USE OR GENERATE MORE THAN 250 VRMS OR VDC.
3. US INSTALLATIONS SHOULD BE IN ACCORDANCE WITH ANSI/ISA RP 12.06.01 "INSTALLATION OF INTRINSICALLY SAFE SYSTEMS
FOR HAZARDOUS (CLASSIFIED) LOCATIONS" AND THE NATIONAL ELECTRICAL CODE
®
(ANSI / NFPA70) SECTIONS 504 AND 505.
4. THE CONFIGURATION OF ASSOCIATED APPARATUS MUST BE CSA APPROVED UNDER ENTITY CONCEPT FOR THE HAZARDOUS
(CLASSIFIED) LOCATION IT SERVES.
5. ASSOCIATED APPARATUS MANUFACTURER'S INSTALLATION DRAWING MUST BE FOLLOWED WHEN INSTALLING THIS EQUIPMENT.
6. NO REVISION TO DRAWING WITHOUT PRIOR APPROVAL BY CSA GROUP.
7. FOR CANADIAN INSTALLATIONS, SENSOR CASE MUST BE BONDED TO GROUND ACCORDING TO SECTION 18-074 OF THE CEC, PART 1.
FOR US INSTALLATIONS, SENSOR CASE MUST BE BONDED TO GROUND ACCORDING TO ARTICLE 501.30f THE NEC.
8. THE PROTECTION CONCEPT FOR THE 426(X)A SERIES SENSOR IS: INTRINSIC SAFETY FOR USE IN CLASS I, DIV. 1 AND
ZONE 0/1. HAZARDOUS LOCATIONS AND; NON-INCENDIVE/ENERGY LIMITED FOR USE IN CLASS I, DIV. 2 AND ZONE 2 HAZARDOUS LOCATIONS.
9. CANADIAN INSTALLATIONS MUST BE IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE (CEC), PART 1.
10. TYPE 426(X)A-C IS A 2 WIRE LOOP POWERED TRANSMITTER. ALL OTHER TYPES ARE 3 OR 4 WIRE VOLTAGE OUTPUT TRANSDUCERS.
HAZARDOUS (CLASSIFIED) LOCATION
CLASS 1, DIVISION 1,
GROUPS A,B,C AND D.
CLASS I, DIVISION 2,
GROUPS A, B, C AND D.
CLASS 1, ZONE 0,
GROUP IIC.
CLASS 1, ZONE 2,
GROUP IIC.
DAV
TAC
KISTLER
PRESSURE SENSOR
TYPE 426(X)A SERIES
SEE NOTE 1
EARTH TO CASE
SCREEN
NON-HAZARDOUS
LOCATION
CONTROL EQUIPMENT
SEE NOTE 2
REVISIONS
ZONE
REV.
DESCRIPTION
DATE
APPROVED
a
1. REPLACES SCAN. DOC. 901-0002.
2. CHANGE 'INTERNATIONAL' TO 'GROUP' (2 PLACES) IN
'NOTES'.
3/09/2018
ENTITY PARAMETERS
COMPONENT VARIANT
(VAC)
Ui
(V max)
Ii (mA)
(I max)
Pi
(W)
Ci
(nf)
Li
(uH)
4-20mA: 426XA-C
28 180 1 40.7 32
VOLTAGE: 426(X)A-
F,I,L,O,R,U,X,3
42 180 1 29.7 34
MILLIVOLT: 426(X)A-A
15 180 1 14.7 30
Kistler-SWX-DINA2q / ANSI C / Vers. 19-Sep-2017
internal and supplier use
12-Mar-2018
siehe Tabelle
Sht
Ver
Material number
Doc.number
100.307.971
09-Mar-2018
Dav
09-Mar-2018
Dav
Dav
06-Mar-2018
Appr
Chk
Drw
09-Mar-2018
100021097
901-0002
Copy date
Replacement for
Scale
DateChange no
Raw material
First proj.-no
First used
measure. analyze. innovate.
1:1
1 / 1 a
426(X)A Series Control Drw. For CSA
Sht
C
Commercial restrictive legend - all items, assemblies, specifications
and dimensionsincluded on this drawing are proprietary to and
theproperty of Kistler Holding AG and may not be used to manufacture
or duplicate the items shown hereon. The contents of this drawing in
whole, or in part, are not to be reproduced, or disclosed to any third
party without obtaining the express written authorization of Kistler
Holding AG.
100.307.971 - a - YDI - Mat.-Zeichnung - interne und externe Fertigung - Freigegeben --- siehe Tabelle --- 24-May-2018 15:23 (CET) - [email protected]
Disposal Instructions for Electrical and Electronic
Equipment
Do not discard old electronic instruments in municipal trash. For
disposal at end of life, please return this product to an authorized
local electronic waste disposal service or contact the nearest
Kistler Instrument sales office for return instructions.
14
15
002-441a-01.21 © 2017 ... 2021 Kistler Group
www.kistler.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Kistler 4260A Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI