13
Control drawing 100.307.971, for installation in Canada and North America
± 1 / 64
ASME Y 14.5 M
±.01
±.005
*=KISTLER-Standard
X°±2°
.XXX.XX
Tolerance
Fractions
Angle
Dimension
Standard tolerances
CODE IDENT 58679
Unless otherwise specified:
Dimensions are in inches
Finish:
Remove all burrs and break
sharp edges 0.005 Max.
NOTES:
1. THE INTRINSIC SAFETY ENTITY CONCEPT ALLOWS THE INTERCONNECTION OF THE TWO INTRINSICALLY SAFE DEVICES APPROVED
BY CSA GROUP WITH ENTITY PARAMETERS NOT SPECIFICALLY EXAMINED IN COMBINATION AS A SYSTEM WHEN:
Uo OR Voc
≤
Ui OR Vmax; Io OR Isc
≤
Ii OR Imax; Po OR Pmax
≤
Pi OR Pmax; Co OR Ca
≥
Ci; Lo OR La
≥
Li.
2. CONTROL EQUIPMENT CONNECTED TO THE ASSOCIATED APPARATUS MUST NOT USE OR GENERATE MORE THAN 250 VRMS OR VDC.
3. US INSTALLATIONS SHOULD BE IN ACCORDANCE WITH ANSI/ISA RP 12.06.01 "INSTALLATION OF INTRINSICALLY SAFE SYSTEMS
FOR HAZARDOUS (CLASSIFIED) LOCATIONS" AND THE NATIONAL ELECTRICAL CODE
®
(ANSI / NFPA70) SECTIONS 504 AND 505.
4. THE CONFIGURATION OF ASSOCIATED APPARATUS MUST BE CSA APPROVED UNDER ENTITY CONCEPT FOR THE HAZARDOUS
(CLASSIFIED) LOCATION IT SERVES.
5. ASSOCIATED APPARATUS MANUFACTURER'S INSTALLATION DRAWING MUST BE FOLLOWED WHEN INSTALLING THIS EQUIPMENT.
6. NO REVISION TO DRAWING WITHOUT PRIOR APPROVAL BY CSA GROUP.
7. FOR CANADIAN INSTALLATIONS, SENSOR CASE MUST BE BONDED TO GROUND ACCORDING TO SECTION 18-074 OF THE CEC, PART 1.
FOR US INSTALLATIONS, SENSOR CASE MUST BE BONDED TO GROUND ACCORDING TO ARTICLE 501.30f THE NEC.
8. THE PROTECTION CONCEPT FOR THE 426(X)A SERIES SENSOR IS: INTRINSIC SAFETY FOR USE IN CLASS I, DIV. 1 AND
ZONE 0/1. HAZARDOUS LOCATIONS AND; NON-INCENDIVE/ENERGY LIMITED FOR USE IN CLASS I, DIV. 2 AND ZONE 2 HAZARDOUS LOCATIONS.
9. CANADIAN INSTALLATIONS MUST BE IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE (CEC), PART 1.
10. TYPE 426(X)A-C IS A 2 WIRE LOOP POWERED TRANSMITTER. ALL OTHER TYPES ARE 3 OR 4 WIRE VOLTAGE OUTPUT TRANSDUCERS.
HAZARDOUS (CLASSIFIED) LOCATION
CLASS 1, DIVISION 1,
GROUPS A,B,C AND D.
CLASS I, DIVISION 2,
GROUPS A, B, C AND D.
CLASS 1, ZONE 0,
GROUP IIC.
CLASS 1, ZONE 2,
GROUP IIC.
DAV
TAC
KISTLER
PRESSURE SENSOR
TYPE 426(X)A SERIES
SEE NOTE 1
EARTH TO CASE
SCREEN
NON-HAZARDOUS
LOCATION
CONTROL EQUIPMENT
SEE NOTE 2
REVISIONS
ZONE
REV.
DESCRIPTION
DATE
APPROVED
a
1. REPLACES SCAN. DOC. 901-0002.
2. CHANGE 'INTERNATIONAL' TO 'GROUP' (2 PLACES) IN
'NOTES'.
3/09/2018
ENTITY PARAMETERS
COMPONENT VARIANT
(VAC)
Ui
(V max)
Ii (mA)
(I max)
Pi
(W)
Ci
(nf)
Li
(uH)
4-20mA: 426XA-C
28 180 1 40.7 32
VOLTAGE: 426(X)A-
F,I,L,O,R,U,X,3
42 180 1 29.7 34
MILLIVOLT: 426(X)A-A
15 180 1 14.7 30
Kistler-SWX-DINA2q / ANSI C / Vers. 19-Sep-2017
internal and supplier use
12-Mar-2018
siehe Tabelle
Sht
Ver
Material number
Doc.number
100.307.971
09-Mar-2018
Dav
09-Mar-2018
Dav
Dav
06-Mar-2018
Appr
Chk
Drw
09-Mar-2018
100021097
901-0002
Copy date
Replacement for
Scale
DateChange no
Raw material
First proj.-no
First used
measure. analyze. innovate.
1:1
1 / 1 a
426(X)A Series Control Drw. For CSA
Sht
C
Commercial restrictive legend - all items, assemblies, specifications
and dimensionsincluded on this drawing are proprietary to and
theproperty of Kistler Holding AG and may not be used to manufacture
or duplicate the items shown hereon. The contents of this drawing in
whole, or in part, are not to be reproduced, or disclosed to any third
party without obtaining the express written authorization of Kistler
Holding AG.
100.307.971 - a - YDI - Mat.-Zeichnung - interne und externe Fertigung - Freigegeben --- siehe Tabelle --- 24-May-2018 15:23 (CET) -
[email protected]