Omega CT89 Series Owner's manual

Type
Owner's manual
omega.com
For latest product manuals:
omegamanual.info
Users Guide
CT89 SERIES
Temperature Recorder
Extended Warranty
Program
SM
MADE IN
Shop online at
Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
ISO 9001 Certified
Stamford, CT 06907-0047
Toll-Free: 1-800-826-6342 Tel: (203) 359-1660
FAX: (203) 359-7700 e-mail: [email protected]
Canada: 976 Bergar
Laval (Quebec), H7L 5A1 Canada
Toll-Free: 1-800-826-6342 TEL: (514) 856-6928
FAX: (514) 856-6886 e-mail: [email protected]
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico En Español: 001 (203) 359-7803 FAX: 001 (203) 359-7807
Servicing Europe:
Benelux: Managed by the United Kingdom Office
Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21
FAX: +31 20 643 46 43 e-mail: [email protected]
Czech Republic: Frystatska 184
733 01 Karviná, Czech Republic
Toll-Free: 0800-1-66342 TEL: +420-59-6311899
FAX: +420-59-6311114 e-mail: [email protected]
France: Managed by the United Kingdom Office
Toll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00
FAX: +33 (0) 130 57 54 27 e-mail: [email protected]
Germany/Austria: Daimlerstrasse 26
D-75392 Deckenpfronn, Germany
Toll-Free: 0800 6397678 TEL: +49 (0) 7056 9398-0
FAX: +49 (0) 7056 9398-29 e-mail: [email protected]
United Kingdom: OMEGA Engineering Ltd.
ISO 9001 Certified
One Omega Drive, River Bend Technology Centre, Northbank
Irlam, Manchester M44 5BD United Kingdom
Toll-Free: 0800-488-488 TEL: +44 (0) 161 777-6611
FAX: +44 (0) 161 777-6622 e-mail: [email protected]
OMEGAnet
®
Online Service Internet e-mail
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI
regulations that apply. OMEGA is constantly pursuing certification of its products to the European New
Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any
errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, human applications.
1
I
NTRODUCTION
The CT89 is a precision instrument used to monitor and record temperature on a 6”
circular paper chart. The CT89 may be carried as a portable instrument or mounted
in a fixed location.
The CT89 offers a variety of features to meet any temperature recording require-
ments. A combination of three temperature ranges and four chart speeds provide
a high degree of flexibility. In addition, the chart rotation may be set for single or
continuous turn operation as required by a particular application. To protect the data
being recorded the CT89 uses an automatic battery backup to maintain operation
during a power outage.
CHANGING PENS
BATTERY HOLDER
PLUG-IN AC
ADAPTER
17
FIG. 1
LATCH
TWO REAR KEYWAY SLOTS
FOR WALL MOUNTING
16
19
13
12
2
3
4
6
5
7
10
9
8
1
2
11
15
12
14
13
16
18
19
5a
CT89 FEATURES AND CONTROLS
1. The 3 DIGIT TEMPERATURE DISPLAY shows temperature of the environment
being monitored. When the batteries are nearly discharged, the display will
alternate the display reading and “LO” to advise the operator that the batteries are
discharged and the CT89 will shortly cease operation.
NOTE: The battery backup feature of the CT89 is primarily intended for use in
situations where primary power is lost for short periods of up to 48 hours. The
CT89 is not intended to be used as a battery powered instrument. If the CT89 is to
be stored for an extended period, it is strongly advised to disconnect the battery
pack and remove the batteries to avoid damage to the instrument from battery
leakage.
2. The TEMPERATURE RANGE SELECTOR allows the user to choose the desired
temperature range for measurement and recording.
3. The CHART SPEED SELECTOR allows the user to select the time of one full
chart revolution. The corresponding chart has to be chosen according to the
desired chart speed. Chart part numbers are listed in this manual.
4. The PEN POSITION ADJUSTMENT KNOB allows the user to adjust the position
of the chart pen.
5. The CHART ADVANCE BUTTON allows the operator to set the chart to the cor-
rect time. Press and hold the chart advance button until the desired time lines
up with the Time Pointer. The chart is rotated counterclockwise only. CAUTION:
Movement of the Chart Spindle (Item 9) by hand may cause permanent dam-
age to the chart mechanism.
5a. The TIME POINTER
6. TEMPERATURE ADJUSTMENT feature allows the user to adjust the reading of
the digital display during periodic calibration. The CT89 has been factory calibrat-
ed and requires no adjustment to meet all published specifications.
7. The POWER ON/OFF / CONTINUOUS / SINGLE CHART SELECTOR allows the
user to apply power to the CT89 and to select Continuous or Single Turn for the
chart rotation. When power is first applied to the CT89, the display will show “888”
to test each segment of the display, and the pen will move to the edge of the
chart. The pen will then move to the correct position on the chart. In the Continu-
ous switch position, the chart will rotate until power is removed. In the Single Turn
switch position, the chart will make one complete revolution and stop. A blinking
dot on the display (Item 1) will indicate that the chart has made one complete
revolution and stopped. To reset the chart for another revolution place the
switch in the Continuous switch position until the blinking dot goes out and then
slide the switch back to the Single Turn position. The chart will make one com-
plete revolution and stop.
DO NOT move the pen by hand or interrupt the pen movement. Failure to observe
this will cause the pen to read incorrectly and may result in damage to the pen
mechanism.
8. The RECORDING PEN contains special ink. The pen has a wrap-around arm
latch which makes the pen replacement “A SNAP!” To replace the pen, gently lift
up the PEN ARM, (do not over bend pen arm) release the pen latch by pushing it
3
4
down, and remove the pen; place a new pen on top of the pen arm, align the
notches on the pen arm with the notches on the pen latch and close the latch
by wrapping it around the pen holder until it is secured. Replace cap on the
pen tip when the CT89 is not used to insure long pen life. For pen installation see
Fig. 1.
9. The CHART SPINDLE holds and rotates the chart during the recording opera-
tion. DO NOT ROTATE THE SPINDLE BY HAND AS IT MAY DAMAGE THE
INTERNAL MECHANISM.
10. The PAPER CHART is 6 inches in diameter. in a box of 60 charts each. The
chart part numbers are listed on the following page.
TO INSTALL A NEW CHART disconnect power from the CT89 by selecting
OFF with the Power / Single/ Continuous Chart Selector. Place pen cap on pen
point. Gently lift the pen arm and while holding it remove the old chart. Slide a
new chart under the pen holder and the chart holding tabs. Align the chart with
the chart spindle. Apply power to the CT89 and rotate the chart by depressing
the chart advance button until the time pointer is aligned with the line on the
chart representing the right time or day. Remove the pen cap. If desired, adjust
the pen position according to the scale you wish to record.
11. The ROTATION POINTER indicates direction of chart rotation.
12. The HANDLE for carrying folds towards the back of the case to be out of the
way when CT89 is mounted on the panel or on the wall.
13. The KEYHOLE SLOTS located on the back of the case are provided for wall or
panel mounting.
14. The FRONT COMPARTMENT under chart was designed to store the battery
holder for battery backup as well as the connection for the adapter box.
15. The REMOTE TEMPERATURE SENSOR is interchangeable. The furnished
4" stainless steel sensor has 15 feet of cable. The temperature sensor is an
electronic digital proprietary design for precision and very high interference im-
munity. It utilizes the standard RCA connector.
Note:
The 4 inch metal probe tip may be immersed in fluids compatible with 304
stanless steel. The black platic probe sheathing is moisture resistant, but
should not be submersed. If moisture is present the sheathing should be
protected or probe failure will occur.
5
16. The BATTERY HOLDER is stored in the front compartment for backup batteries.
Use of 8 alkaline “AA” batteries is required for proper operation.
17. The 12VDC PLUG IN WALL ADAPTER provides primary power for the CT89.
Alternate sources of 12 Volt power may also be used. This allows use of the CT89
in automotive, marine or other mobile applications.
18. The POWER CONNECTOR is a connection point for the 12VDC wall adapter or
alternate source of 12VDC power.
19. Back Brace for counter top use.
L
OW TEMPERATURE (CT89) CHART PART NUMBERS
CT87C- -40-30F / 24H CT87 - -40-0C / 24H
CT87C- -40-30F / 6H CT87C- -40-0C / 6H
CT87C- -40-30F / 7D CT87C- - 40-0C / 7D
CT87C- -20-50F / 24H CT87C- -30-10C / 24H
CT87C- -20-50F / 6H CT87C- -30-10C / 6H
CT87C- -20-50F / 7D CT87C- -30-10C / 7D
CT87C-50-120F / 24H CT87C-10-50C / 24H
CT87C-50-120F / 6H CT87C-10-50C / 6H
CT87C-50-120F / 7D CT87C-10-50C / 7D
CT87C-LF-MIX CT87C-LC-MIX
SPECIFICATIONS
Temperature Scale Selectable -40°F to +30°F, -20°F to +50°F,
(Fahrenheit Model) +50°F to +120°F
Temperature Scale Selectable -40°C to 0°C, -30°C to +10°C,
(Celsius Model) +10°C to +50°C
Chart Speed Selectable 6 Hours, 24 Hours, 7 Days, 31 Day
Chart Speed Accuracy +/-1%
Chart Diameter 6 Inches
Temperature Display 3 Digit LED 0.5"
Temperature Accuracy +/-2°F (+/-1°C)
Temperature Sensor Stainless steel tip submersible with 15 ft. of
cable
Recording Pen Ink Type
Power Supply 120 VAC, 50/60 Hz. or 220/240 VAC, 50Hz.
Battery Backup 8 Alkaline “AA” cells (Not included)
Battery Life 48 Hours
Operating Ambient
Temperature Range +32°F to +120°F (0°C to +49°C)
Relative Humidity 96% maximum
Dimensions 9 ¼” x 7 ¼” x 2 ¾”
Weight 4 lbs., 7 oz.
CAUTION: The Temperature Recorder should be placed outside the chamber being
monitored. DO NOT PLACE THE RECORDER DIRECTLY IN AREAS OF EXTREME
TEMPERATURES, HIGH HUMIDITY OR HEAVY CHEMICAL CONTENT.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and
workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds
an additional one (1) month grace period to the normal one (1) year product warranty to
cover handling and shipping time. This ensures that OMEGA’s customers receive maximum
coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer
Service Department will issue an Authorized Return (AR) number immediately upon phone or
written request. Upon examination by OMEGA, if the unit is found to be defective, it will be
repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting
from any action of the purchaser, including but not limited to mishandling, improper
interfacing, operation outside of design limits, improper repair, or unauthorized modification.
This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows
evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture
or vibration; improper specification; misapplication; misuse or other operating conditions
outside of OMEGA’s control. Components in which wear is not warranted, include but are not
limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes
liability for any damages that result from the use of its products in accordance with
information provided by OMEGA, either verbal or written. OMEGA warrants only
that the parts manufactured by the company will be as specified and free of
defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY
KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL
IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total
liability of OMEGA with respect to this order, whether based on contract, warranty,
negligence, indemnification, strict liability or otherwise, shall not exceed the
purchase price of the component upon which liability is based. In no event shall
OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1)
as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or
activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or
with any nuclear installation or activity, medical application, used on humans, or misused in
any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER
language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from
any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN
AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT
(IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be
marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to
prevent breakage in transit.
FOR WARRANTY
RETURNS, please have
the following information available BEFORE
contacting OMEGA:
1. Purchase Order number under which
the product was PURCHASED,
2. Model and serial number of the product
under warranty, and
3. Repair instructions and/or specific
problems relative to the product.
FOR NON-WARRANTY REPAIRS,
consult
OMEGA for current repair charges. Have the
following information available BEFORE
contacting OMEGA:
1. Purchase Order number to cover the
COST of the repair,
2. Model and serial number of theproduct, and
3. Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible.
This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2011 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without
the prior written consent of OMEGA ENGINEERING, INC.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
SM
TEMPERATURE
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain Gages
Load Cells & Pressure Gages
Displacement Transducers
Instrumentation & Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine/Paddlewheel Systems
Totalizers & Batch Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISITION
Data Acquisition & Engineering Software
Communications-Based Acquisition Systems
Plug-in Cards for Apple, IBM & Compatibles
Data Logging Systems
Recorders, Printers & Plotters
HEATERS
Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen Instruments
M4927/0510
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Omega CT89 Series Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI