Paradyne Acculink 3164 DSU, ACCULINK 3160, Acculink 3160 CSU, Acculink 3160 DSU, ACCULINK 3164, Acculink 3164 CSU Reference guide

  • Hello! I am an AI chatbot trained to assist you with the Paradyne Acculink 3164 DSU Reference guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ACCULINK 3160 AND 3164
DSU/CSU
QUICK REFERENCE
Document No. 3160-A2-GL11-60
Copyright 1998 Paradyne Corporation.
All rights reserved.
Printed in U.S.A.
Notice
This publication is protected by federal copyright law. No part of this publication may be
copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated
into any human or computer language in any form or by any means, electronic,
mechanical, magnetic, manual or otherwise, or disclosed to third parties without the
express written permission of Paradyne Corporation, 8545 126th Ave. N., Largo,
FL 33773.
Paradyne Corporation makes no representation or warranties with respect to the
contents hereof and specifically disclaims any implied warranties of merchantability or
fitness for a particular purpose. Further, Paradyne Corporation reserves the right to
revise this publication and to make changes from time to time in the contents hereof
without obligation of Paradyne Corporation to notify any person of such revision or
changes.
Changes and enhancements to the product and to the information herein will be
documented and issued as a new release to this manual.
Warranty, Sales, and Service Information
Contact your local sales representative, service representative, or distributor directly for
any help needed. For additional information concerning warranty, sales, service, repair,
installation, documentation, training, distributor locations, or Paradyne worldwide office
locations, use one of the following methods:
Via the Internet: Visit the Paradyne World Wide Web site at
http://www.paradyne.com
Via Telephone: Call our automated call system to receive current information via
fax or to speak with a company representative.
Within the U.S.A., call 1-800-870-2221
Outside the U.S.A, call 1-727-530-2340
Document Feedback
We welcome your comments and suggestions about this document. Please mail them
to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773,
or send e-mail to [email protected]. Include the number and title of this
document in your correspondence. Please include your name and phone number if you
are willing to provide additional clarification.
Trademarks
All products and services mentioned herein are the trademarks, service marks,
registered trademarks or registered service marks of their respective owners.
TM
1
ACCULINK 3160 and 3164 DSU/CSU
Quick Reference
Document Number 3160-A2-GL11-60
November 1998
Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the
documentation for specific topics and print only what you need, reducing the waste of
surplus printing. It also helps us maintain competitive prices for our products.
Complete documentation for this product is available at www.paradyne.com.
Select
Service & Support
Technical Manuals
T1/E1 Digital Access Devices.
Select the following document:
3160-A2-GB21
ACCULINK 316x Data Service Unit/Channel Service Unit Operators Guide
To request a paper copy of a Paradyne document:
Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
Outside the U.S.A., call 1-727-530-8623
Before installing the DSU/CSU, read the
Important Safety Instructions
beginning on
page 18.
2
Quick Start Procedure
The following procedure is for experienced DSU/CSU users who are familiar with the
3160/3164 DSU/CSU installation process and have no special requirements for their
application. See the
ACCULINK 316x Data Service Unit/Channel Service Unit
Operators Guide
for more information.
1. Attach the power cord to the rear of the DSU/CSU and the other end to a grounded
115 Vac power outlet.
2. Attach the 3160/3164 DSU/CSU network connection to the T1 network using the
appropriate cable. Attach the 3160/3164 DSU/CSU to the customer premises
equipment via the DTE (DSX-1) and/or port connectors.
3. Power on the DSU/CSU to perform the power-up self-test.
4. If you intend to use front panel emulation, connect the cable from the PC to the
COM port on the rear panel of the DSU/CSU.
5. If you intend to manage the 3160/3164 DSU/CSU with SNMP, cable either the
COM or MODEM port (as appropriate for your configuration). Then, configure the
SNMP management link.
6. If you do not intend to use the DTE Drop/Insert T1 port, disable it using the
configuration procedures in Chapter 3,
Operation
, and Appendix C,
Configuration
Options
, of the
Operators Guide
. (The default setting for this port is Enabled.)
7. The Factory 1 configuration for ESF framing format and B8ZS line coding format is
the default configuration and is appropriate for most networks. If this configuration
does not work for you, try the Factory 2 configuration for D4 framing format and
AMI line coding format. To further customize configuration options, refer to
Changing Configuration Options
in Chapter 3,
Operation
, and to Appendix C,
Configuration Options
,
in the
Operators Guide
.
8. During the power-up self-test, the FAIL LED flashes, then all LEDs blink twice.
When the test is complete, verify that the DSU/CSU is functional by observing that
the OK, NETWORK SIG, and DTE SIG LEDs are lit.
9. Configure the ports and channels you intend to use and assign channels to the
network interface.
3
PORT 2PORT 1CLOCK IN
PORT 4PORT 3
AUX PORT
COM PORT MODEM
DTE
POWER
NETWORK
CAUTION:
AUX PORT OR COM PORT MUST NOT BE CONNECTED TO PSTN OR T1 NETWORK
NEC
CLASS 2
INPUT
PORT 2PORT 1CLOCK IN
AUX PORT
COM PORT MODEM
DTE
POWER
NETWORK
CAUTION:
AUX PORT OR COM PORT MUST NOT BE CONNECTED TO PSTN OR T1 NETWORK
NEC
CLASS 2
INPUT
97-15573
Modem
Power
Modem
Power
Front
Panel
3164 DSU/CSU
3164
DSU/CSU
3160
DSU/CSU
Serial
Port
or
COM Port
Network
Port
Modem
Port
COM
Port
Network
Port
Modem
Port
Network
Port
To
Router
or
SNMP
Manager
SNMP
Manager
PC
or
T1 OR Serial Connections
Dial Connections
Terminal
Terminal
or
PSTN
T1 Network
Cabling Examples
4
Configuration Options
Configuration options are accessed from the Cnfig branch of the front panel menu.
DSU ESF
Stat
97-15574
DevHS
STest Perf TSt at LED ID
T1 PrtnPrtnUserTelco
Cur 24Tot Intvl
FarNear
Cur 8Tot Intvl
Test
Rlpbk Lpbk Ptrns Lamp
QRSS 511
Abort Mon
LLBUP
LLBDN
54UP
54DN
FT1UP
FT1DN
PLB DLB RLBLLBAbort DCLB DTLB
QRSS 1in8 511
Send
Cnfig
EQPT NET
Ctrl
Rel ClrReg
Reset
CID
PasswdLED
DL
Mon
Call
DiscDialPass ChDir
1 . . 5,A
(Directory)
1 . . 5,A
(Directory)
DTE Prt1 Prt2 Prt3 Prt4
User Prt1 Prt2 Prt3 Prt4
FarNear
Load Edit Area From:
Choose Function:
Activ Cust1 Cust2 Fact1 Fact2
User AlarmNETDTE Port Chan Gen Mgmt
Gen Trap
DTE
Prt1
Prt2
Prt3
Prt4
Clear
Dsply
Copy Prt1 Prt2 Prt3 Prt4
Port Select :
All
Prt1
Prt2
Prt3
Prt4
Save
Cust1Activ Cust2
Edit
5
Factory default configuration options are shown in boldface type in the following tables.
Table 1. DTE Interface Configuration Options
Option Factory 1 Factory 2 Comments/Description
DTE Port:
Enab Enab
Enables the use of the DTE
DTE Port:
Disab Disab
Enables
the
use
of
the
DTE
Drop/Insert port.
DTE Framing:
D4 D4
Selects D4 or ESF framing format
DTE Framing:
ESF ESF
Selects D4 or ESF framing format.
DTE Coding:
AMI AMI
Selects AMI or B8ZS line codin
g
DTE Coding:
B8ZS B8ZS
S
e
l
ec
t
s
AMI
or
B8ZS
li
ne co
di
ng
format.
0–133 0–133
Equal:
133–266 133–266
Equal:
(DTE Line
Eli)
266–399 266–399
Provides selectable extended DTE
ran
g
e ca
p
abilit
y
.
(DTE Line
Equalizer)
399–533 399–533
range capa
bilit
y.
533–655 533–655
Extrn DLB:
(External DTE
Enab Enab
Allows control of DLB on external
(External DTE
Loopback)
Disab Disab
All
ows con
t
ro
l
o
f
DLB
on ex
t
erna
l
contact closure.
Send Ones:
Enab Enab
Sends all ones on channels
allocated to the network T1 on
Send Ones:
Disab Disab
allocated to the network T1 on
LOS, LOF, or AIS.
Table 2. Port Configuration Options (1 of 3)
Option Factory 1 Factory 2 Comments/Description
E530 E530
Port Type:
V.35 V.35
Selects the
p
ort t
yp
e: EIA-530A
,
Port Type:
RS449 RS449
S
e
l
ects t
h
e port type:
EIA
-530
A
,
V.35, RS449, or X.21.
X.21 X.21
Base Rate:
Nx64 Nx64
Enables the
p
ort to either Nx56 or
Base Rate:
Nx56 Nx56
E
na
bl
es
th
e por
t
t
o e
ith
er
N
x
56
or
Nx64 rates.
6
Table 2. Port Configuration Options (2 of 3)
Option Comments/DescriptionFactory 2Factory 1
Disab Disab
Net DCLB:
V.54 V.54
Network-initiated DCLB, allows
DCLB t b t ll d b i b d
Net DCLB:
FT1 FT1
Network initiated DCLB, allows
DCLB to be controlled by inband
V.54 or FT1 (ANSI) codes.
Both Both
5 o ( S ) codes
Disab Disab
Port LB:
DTLB DTLB
Port-initiated Loopbacks, allows
Loopbacks to be initiated through
Port LB:
DCLB DCLB
p,
Loopbacks to be initiated through
the port by the external DTE.
Both Both
epo by ee e a
Disab Disab
All Ones:
DTR DTR
All ones sent to network
(
DTE
)
T1
All Ones:
RTS RTS
All
ones sen
t
t
o ne
t
wor
k
(DTE)
T1
when DTR or RTS interrupted.
Both Both
Rcv Yellow:
None None
Data port remains enabled, or is
disabled on receiving Yellow on
R
cv
Y
e
ll
ow:
(Received Yellow)
Halt Halt
p,
disabled, on receiving Yellow on
network T1.
Tx Clock:
Int Int
Selects whether the transmitted
data clock is internal (TXC) or
Tx Clock:
Ext Ext
data clock is internal (TXC) or
external (XTXC).
InvertTxC:
Enab Enab
Selects
p
hase inversion of the
I
nver
tT
x
C
:
(Invert Tx Clock)
Disab Disab
S
e
l
ec
t
s p
h
ase
i
nvers
i
on o
f
th
e
transmit clock (TXC).
InvertData:
Enab Enab
Allows the data on the
p
ort to be
InvertData:
Disab Disab
All
ows
th
e
d
a
t
a on
th
e por
t
t
o
b
e
inverted.
EDL:
Enab Enab
S
p
ecifies whether the Embedded
EDL:
Disab Disab
S
pec
ifi
es w
h
e
th
er
th
e
E
m
b
e
dd
e
d
Data Link is enabled.
10E–4 10E–4
10E–5 10E–5
Err Rate:
(Excessive Error
10E–6 10E–6
Selects the error rate threshold for
Excessive Error Rate Alarm
(Excessive Error
Rate)
10E–7 10E–7
Excessive Error Rate Alarm.
ae)
10E–8 10E–8
10E–9 10E–9
7
Table 2. Port Configuration Options (3 of 3)
Option Comments/DescriptionFactory 2Factory 1
Disab Disab
Near end:
Maint Maint
Specifies whether the device will
maintain near endperformance
Near-end:
Send Send
p
maintain near-end performance
statistics.
Both Both
sascs
Far end:
Disab Disab
Specifies whether the device will
maintain far endperformance
Far-end:
Maint Maint
p
maintain far-end performance
statistics.
Mgmt Link:
Enab Enab
S
p
ecifies whether the EDL
Mgmt Link:
Disab Disab
S
pec
ifi
es w
h
e
th
er
th
e
EDL
Management Link is enabled.
Table 3. Network Interface Configuration Options
Option Factory 1 Factory 2 Comments/Description
NET Framing:
D4 D4
Selects D4 or ESF framing format
NET Framing:
ESF ESF
Selects D4 or ESF framing format.
NET Coding:
AMI AMI
Selects AMI or B8ZS line coding
NET Coding:
B8ZS B8ZS
Selects
AMI
or
B8ZS
line
coding
format.
0.0 0.0
LBO:
–7.5 –7.5
Provides Line Build Out in dB
LBO:
–15 –15
Provides Line Build Out in dB.
–22.5 –22.5
ANSI PRM:
Enab Enab
Sends ANSI Performance Report
ANSI PRM:
Disab Disab
Sends
ANSI
Performance
Report
Messages.
Mgmt Link:
Enab Enab
Specifies whether the FDL’s
Mgmt Link:
Disab Disab
Specifies
whether
the
FDLs
Management Link is enabled.
NET LLB:
Enab Enab
Network-initiated LLB allows LLB to
NET LLB:
Disab Disab
Network-initiated
LLB
allows
LLB
to
be controlled by inband LLB codes.
NET PLB:
Enab Enab Network-initiated PLB allows PLB
to be controlled by FDL PLB
NET PLB:
Disab Disab
to be controlled by FDL PLB
messages.
62411 62411
Provides enforcement of ones
d it t ti AT&T TR
BitStuff:
Part68 Part68
Provides enforcement of ones
density protection per AT&T TR
62411
,
ANSI T1-403
,
and FCC
BitStuff:
Disab Disab
62411
,
ANSI
T1
-
403
, an
d
FCC
Part 68 Technical Publication.
Circuit Ident:
Edit Edit
Specifies the transmission vendors
Circuit
Ident:
Clear Clear
Specifies
the
transmission
vendor s
circuit identifier.
8
Table 4. DTE Channel Configuration Options
Line 1 Displays: Line 2 Displays: Meaning Comments/Description
Unassigned
N1 N2 N3 ...... N24:
D1, D2 ... D24
Channel
assigned to this
DTE channel
Function key under the channel
(N1, N2, etc.) selects the DTE
channel to assi
g
n
(
D1 throu
g
h
N1
N2
N3
......
N24
:
Prt1
Prt2
Prt3
Prt4
Channel
assigned to port
1,2,3, or 4
c
h
anne
l
to ass
i
gn
(D1
t
h
roug
h
D24, or –).
Data Data Channel
Function key under the channel
D1 D2 D3 ...... D24:
RBS
Voice
Channel
Function
key
under
the
channel
(D1, D2, etc.) selects either Data
or RBS.
Table 5. Data Port Channel Configuration Options (1 of 2)
Option Factory 1 Factory 2 Comments/Description
NET NET
Assigns this port to channels on
Assign To:
DTE DTE
Assigns this port to channels on
the Network or DSX-1 T1 interface,
ttht
Assign To:
Prt
n
Prt
n
the Network or DSX 1 T1 interface,
or to another port.
Block Block
Determines how channels are
Assign By:
ACAMI ACAMI
Determines how channels are
assigned: contiguous blocks,
ACAMI i di id l h l
Assign By:
Chan Chan
assigned: contiguous blocks,
ACAMI or individual channels.
Port Rate:
64 (56)
128 (112)
192 (168)
256 (224)
320 (280)
384 (336)
448 (392)
512 (448)
576 (504)
640 (560)
704 (616)
768 (672)
832 (728)
896 (784)
960 (840)
1024 (896)
1088 (952)
1152 (1008)
1216 (1064)
1280 (1120)
1344 (1176)
1408 (1232)
1472 (1288)
1536 (1344)
64 (56)
128 (112)
192 (168)
256 (224)
320 (280)
384 (336)
448 (392)
512 (448)
576 (504)
640 (560)
704 (616)
768 (672)
832 (728)
896 (784)
960 (840)
1024 (896)
1088 (952)
1152 (1008)
1216 (1064)
1280 (1120)
1344 (1176)
1408 (1232)
1472 (1288)
1536 (1344)
Selects the data rate for the port.
The possible rates depend on
whether the port is configured for
Nx56 or Nx64.
This configuration option only
appears if the “Assigned By”
configuration option is Block or
ACAMI.
9
Table 5. Data Port Channel Configuration Options (2 of 2)
Option Factory 1 Factory 2 Comments/Description
Clear Clear
Clears (unassigns) channels for
this port.
Start At:
N1 (D1)
N2 (D2)
N3 (D3)
N4 (D4)
N5 (D5)
N6 (D6)
N7 (D7)
N8 (D8)
N9 (D9)
N10 (D10)
N11 (D11)
N12 (D12)
N13 (D13)
N14 (D14)
N15 (D15)
N16 (D16)
N17 (D17)
N18 (D18)
N19 (D19)
N20 (D20)
N21 (D21)
N22 (D22)
N23 (D23)
N24 (D24)
N1 (D1)
N2 (D2)
N3 (D3)
N4 (D4)
N5 (D5)
N6 (D6)
N7 (D7)
N8 (D8)
N9 (D9)
N10 (D10)
N11 (D11)
N12 (D12)
N13 (D13)
N14 (D14)
N15 (D15)
N16 (D16)
N17 (D17)
N18 (D18)
N19 (D19)
N20 (D20)
N21 (D21)
N22 (D22)
N23 (D23)
N24 (D24)
This configuration option appears if
the “Assigned By” configuration
option is Block or ACAMI.
Line 1 Displays: Line 2 Displays: Meaning Comments/Description
Unassigned
N1 N2 N3 ...... N24:
(If assigned to NET)
Prt1
Prt2
Prt3
Prt4
Channel assigned
to port 1, 2, 3, or 4
This configuration option appears if
the “Assigned By” configuration
option is individual channels
(Chan)
(If
assigned
to
NET)
D1 D2 D3 ..... D24:
(If assigned to DTE)
D1, D2 ... D24
Channel assigned
to this DTE
channel
p
(Chan).
Function key under the channel
(N1, N2 etc.) assigns (unassigns)
(1 2 3 4) h h l
N1, N2 ... N24
Channel assigned
to this NET
channel
(N1
,
N2
etc
.
)
assigns
(unassigns)
port (1, 2, 3, or 4) to that channel.
10
Table 6. General Configuration Options
Option Factory 1 Factory 2 Comments/Description
Gen Yellow:
Enab Enab
Yellow alarm is
g
enerated b
y
the
G
en
Y
e
ll
ow:
(Generate Yellow)
Disab Disab
Y
e
ll
ow a
l
arm
i
s genera
t
e
d
b
y
th
e
DSU/CSU on LOS, LOF, or AIS.
NET NET
DTE DTE
Selects the clock source to be
Clock Src:
Prt1 Prt1
Selects the clock source to be
used as the master clock for the
DSU/CSU
Clock Src:
Int Int
used as the master clock for the
DSU/CSU.
Ext Ext
2048 2048
Clock Rate:
1544 1544
Selects the clock rate of the source
if external.
Clock Rate:
8 8
if
ex
t
erna
l
.
Tst Timeout:
Enab Enab
Specifies whether the durations of
user initiated tests are limited by
Tst Timeout:
Disab Disab
p
user-initiated tests are limited by
Tst Duration.
10 10
Tst Duration:
Up Up
Specifies the duration of
iititdl b k d tt
Tst Duration:
Down Down
Specifies the duration of
user-initiated loopback and pattern
tests.
Save Save
es s
11
Table 7. User Configuration Options (1 of 3)
Option Factory 1 Factory 2 Comments/Description
Self
-
Test:
Enab Enab
Allows bypass of self-test on
Self-Test:
Disab Disab
Allows
bypass
of
self
-
test
on
initialization.
FP Access:
Enab Enab
Controls whether front panel
FP Access:
Disab Disab
Controls
whether
front
panel
access or display is allowed.
FP Pass:
Enab Enab
Controls whether front panel
FP Pass:
Disab Disab
Controls
whether
front
panel
pass-through is allowed.
Dial
-
In:
Enab Enab
Controls whether dial-in access is
Dial-In:
Disab Disab
Controls
whether
dial
-
in
access
is
allowed.
None None
Password:
Com Com
Controls whether a password is
required for dial-in by a remote
Password:
Modem Modem
required for dial-in by a remote
front panel.
Both Both
front
panel
.
Mgmt Mgmt
Com Use:
ASCII ASCII
Controls how the COM port is
Com Use:
Daisy Daisy
Controls
how
the
COM
port
is
used.
Term Term
Com Type:
Async Async
Controls whether the COM port is
Com Type:
Sync Sync
Controls
whether
the
COM
port
is
synchronous or asynchronous.
Com Clk:
Int Int
Controls whether the COM port
Com Clk:
Ext Ext
Controls
whether
the
COM
port
uses an internal or external clock.
1.2 1.2
2.4 2.4
Com Rate:
4.8 4.8
Com Rate:
(Communication Port
Rt)
9.6 9.6
Selects the bit rate for the COM
p
ort.
(Communication Port
Rate)
14.4 14.4
por
t
.
19.2 19.2
38.4 38.4
Char Length:
7 7
Selects the character length for the
Char Length:
8 8
Selects
the
character
length
for
the
COM port.
CParity:
None None
CParity:
(Communication Port
Parity)
Even Even
Selects the parity for the COM port.
(
Parity)
Odd Odd
py p
12
Table 7. User Configuration Options (2 of 3)
Option Comments/DescriptionFactory 2Factory 1
CStop Bits:
1 1
CStop Bits:
(Communication Port
St Bit )
1.5 1.5
Selects the number of stop bits for
the COM
p
ort.
(Communication Port
Stop Bits)
2 2
th
e
COM
por
t
.
Ignore DTR:
Yes Yes
S
p
ecifies whether the COM
p
ort
Ignore DTR:
No No
S
pec
ifi
es w
h
e
th
er
th
e
COM
por
t
ignores DTR.
CmInActTm:
(COM Port Inactivity
Enab Enab
Specifies whether the
communication port disconnects
(COM Port Inactivity
Timeout)
Disab Disab
p
communication port disconnects
after a certain period of inactivity.
5 5
CmDiscTm:
(
COM Port
Up Up
Specifies the period of inactivity
(
1 to 60 minutes
)
that causes a
(COM
P
or
t
Disconnect Time)
Down Down
(1
t
o
60
m
i
nu
t
es
)
th
a
t
causes a
disconnect if CmInActTm is
enabled.
Save Save
ena
bl
e
d
.
Mgmt Mgmt
Modem Use:
ASCII ASCII
Specifies how the MODEM port is
used.
Term Term
use
d
.
Modem Type:
Async Async
Controls whether the MODEM port
Modem Type:
Sync Sync
Controls
whether
the
MODEM
port
is synchronous or asynchronous.
Modem Rate:
1.2 1.2
Selects the bit rate for the MODEM
Modem Rate:
2.4 2.4
Selects
the
bit
rate
for
the
MODEM
port.
MChar Len:
(Modem Port
7 7
Selects the character len
g
th for the
(Modem Port
Character Length)
8 8
S
e
l
ec
t
s
th
e c
h
arac
t
er
l
eng
th
f
or
th
e
MODEM port.
None None
MParity:
(
Modem Port Parit
y)
Even Even
Selects the parity for the MODEM
p
ort.
(M
o
d
em
P
or
t
P
ar
it
y
)
Odd Odd
por
t
.
MStop Bits:
(Modem Port Stop
1 1
Selects the number of stop bits for
(Modem Port Stop
Bits)
2 2
Selects
the
number
of
stop
bits
for
the MODEM port.
LSpaceDsc:
(Long Space
Enab Enab
Selects the long space disconnect
configuration optionfor terminating
p
(Long Space
Disconnect)
Disab Disab
gp
configuration option for terminating
modem connections.
MoInActTm:
(Modem Port
Enab Enab
Specifies whether the modem port
disconnects after a certain period
(Modem Port
Inactivity Timeout)
Disab Disab
pp
disconnects after a certain period
of inactivity.
13
Table 7. User Configuration Options (3 of 3)
Option Comments/DescriptionFactory 2Factory 1
5 5
MoDiscTm:
(
Modem Port
Up Up
Specifies the period of inactivity
(
1 to 60 minutes
)
that causes a
(M
o
d
em
P
or
t
Disconnect Time)
Down Down
(1
t
o
60
m
i
nu
t
es
)
th
a
t
causes a
disconnect if MoInActTm is
enabled.
Save Save
ena
bl
e
d
.
None None
Aux Use:
Mgmt Mgmt
Controls how the auxiliary port is
used.
Daisy Daisy
used
.
9.6 9.6
Aux Rate:
14.4 14.4
Configures the bit rate for the
Aux Rate:
19.2 19.2
Configures
the
bit
rate
for
the
auxiliary port.
38.4 38.4
TnSession:
Enab Enab
Specifies whether the DSU/CSU
responds to Telnet session
T
n
S
ess
i
on:
(Telnet Session)
Disab Disab
p
responds to Telnet session
requests.
TnPaswd:
Enab Enab
S
p
ecifies whether a
p
assword is
T
n
P
asw
d
:
(Telnet Password)
Disab Disab
S
pec
ifi
es w
h
e
th
er a passwor
d
i
s
required for Telnet sessions.
TnInActTm:
(Telnet Inactivity
Enab Enab
Specifies whether a Telnet session
disconnects after a certain period
(Telnet Inactivity
Timeout)
Disab Disab
p
disconnects after a certain period
of inactivity.
5 5
TnDiscTm:
(
Telnet Disconnect
Up Up
The period of inactivity (1 to
60 minutes
)
that causes a
(T
e
l
ne
t
Di
sconnec
t
Time)
Down Down
60
m
i
nu
t
es
)
th
a
t
causes a
disconnect if TnInActTm is
enabled.
Save Save
ena
bl
e
d
.
14
Table 8. Alarm Configuration Options
Option Factory 1 Factory 2 Comments/Description
Disab Disab Does not display alarm messages.
Al M
Modem Modem
Sends alarm messages to modem
port.
Alrm Msg:
Com Com
Sends alarm messages to COM
port.
Both Both
Sends alarm messages to both
modem and COM ports.
SNMP Trap:
Enab Enab
Sends SNMP traps
SNMP Trap:
Disab Disab
Sends SNMP traps.
TrapDisc:
Enab Enab
Specifies whether the modem
connection will disconnect after a
TrapDisc:
Disab Disab
p
connection will disconnect after a
trap is sent.
DialOut:
Enab Enab
Provides the option to allow
automatic dial out to send alarm
DialOut:
Disab Disab
p
automatic dial-out to send alarm
messages on MODEM port.
Call Retry:
Enab Enab
Specifies whether an outgoing call
is retried on a busy or failed call
Call Retry:
Disab Disab
pgg
is retried on a busy or failed call
attempt.
Dial Delay:
1–4
5
6–10
1–4
5
6–10
The time (in minutes) to delay
between successive alarm
dial-outs or retry attempts.
AltDialDir:
None
1–5
None
1–5
The alternate dial-out directory to
use if a call to the primary number
cannot be completed.
10E–4 10E–4
10E–5 10E–5
Err Rate:
(Excessive Error
10E–6 10E–6 The error rate threshold for
Excessive Error Rate Alarm
(Excessive Error
Rate)
10E–7 10E–7
Excessive Error Rate Alarm.
Rate)
10E–8 10E–8
10E–9 10E–9
15
Table 9. General Management Configuration Options (1 of 2)
Option Factory 1 Factory 2 Comments/Description
SNMP Mgt:
Disab Disab
Specifies whether the DSU/CSU
responds to SNMP session
SNMP Mgt:
Enab Enab
p
responds to SNMP session
requests.
NMS Valid:
Enab Enab
Specifies whether the DSU/CSU
validates the IP address of an
NMS Valid:
Disab Disab
validates
the
IP
address
of
an
SNMP manager attempting
access.
Num Sec Mgrs:
1 1
The number of SNMP managers
Num Sec Mgrs:
2–10 2–10
The
number
of
SNMP
managers
allowed to access the DSU/CSU.
NMS
n
IP Adr:
Edit Edit
Allows you to define or clear the
allowable IP address of an SNMP
NMS
n
IP Adr:
Clear Clear
y
allowable IP address of an SNMP
manager.
NMS
n
Acs:
Read Read
The type of access allowed for an
SNMP manager using community
NMS
n
Acs:
R/W R/W
yp
SNMP manager using community
name 1.
System Name:
Edit Edit
The SNMP system name for this
System Name:
Clear Clear
The
SNMP
system
name
for
this
device.
System Location:
Edit Edit
The SNMP system location for this
System Location:
Clear Clear
The
SNMP
system
location
for
this
device.
System Contact:
Edit Edit
The SNMP system contact name
System Contact:
Clear Clear
The
SNMP
system
contact
name
for this device.
CommunityName1:
Edit Edit
A community name that is allowed
access to this device Defaults to
CommunityName1:
Clear Clear
y
access to this device. Defaults to
public
.
Access 1:
Read Read
The type of access allowed for
Access 1:
R/W R/W
The
type
of
access
allowed
for
community name 1.
CommunityName2:
Edit Edit
A community name that is allowed
CommunityName2:
Clear Clear
A
community
name
that
is
allowed
access to this device.
Access 2:
Read Read
The type of access allowed for
Access 2:
R/W R/W
The
type
of
access
allowed
for
community name 2.
IP Adr:
Edit Edit
The IP address needed to access
IP Adr:
Clear Clear
The
IP
address
needed
to
access
the device.
NetMask:
Edit Edit
The Subnet Mask needed to
NetMask:
Clear Clear
The
Subnet
Mask
needed
to
access the device.
Com IP Adr:
Edit Edit
The IP address for the COM port
Com IP Adr:
Clear Clear
The
IP
address
for
the
COM
port
when configured for SNMP.
16
Table 9. General Management Configuration Options (2 of 2)
Option Comments/DescriptionFactory 2Factory 1
Com NetMask:
Edit Edit
The Subnet Mask needed to
access the device when the COM
Com NetMask:
Clear Clear
access the device when the COM
port is configured for SNMP.
Com Link:
PPP PPP
The link layer protocol for the COM
Com Link:
SLIP SLIP
The
link
layer
protocol
for
the
COM
port when configured for SNMP.
Modem IP Adr:
Edit Edit
Specifies the IP address for the
MODEM port when configured for
Modem IP Adr:
Clear Clear
p
MODEM port when configured for
SNMP.
Mdm NetMask:
Edit Edit
Specifies the Subnet Mask needed
to access the device when the
Mdm NetMask:
Clear Clear
to
access
the
device
when
the
MODEM port is configured for
SNMP.
Alt Mdm IP Adr:
Edit Edit
Specifies the alternate IP address
for the MODEM port when
Alt Mdm IP Adr:
Clear Clear
p
for the MODEM port when
configured for SNMP.
Alt Mdm NetMask:
Edit Edit
Specifies the alternate modem
Subnet Mask needed to access the
Alt Mdm NetMask:
Clear Clear
Subnet
Mask
needed
to
access
the
device when the MODEM port is
configured for SNMP.
Modem Link:
PPP PPP Specifies the link layer protocol for
the MODEM port when configured
Modem Link:
SLIP SLIP
pyp
the MODEM port when configured
for SNMP.
Aux IP Adr:
Edit Edit
Specifies the alternate modem
Subnet Mask needed to access the
Aux IP Adr:
Clear Clear
Subnet
Mask
needed
to
access
the
device when the AUX port is
configured for SNMP.
Aux NetMask:
Edit Edit
Specifies the Subnet Mask needed
to access the device when the
Aux NetMask:
Clear Clear
p
to access the device when the
AUX port is configured for SNMP.
None None
Com Com
Def Netwk:
Modem Modem
Specifies the default network
Def Netwk:
Aux Aux
Specifies
the
default
network
destination.
FDL FDL
EDL
n
EDL
n
17
Table 10. Management Trap Configuration Options
Option Factory 1 Factory 2 Comments/Description
Num Trap Mgrs:
1
2–6
1
2–6
The number of trap managers
supported by the device.
Trap
n
IP Adr:
Edit Edit
Specifies the IP address for each
trap manager. This configuration
Trap
n
IP Adr:
Clear Clear
trap
manager
.
This
configuration
option is repeated for all
n
managers.
None None
Com Com
Trap
n
Dst:
Modem Modem
S
p
ecifies the network destination
Trap
n
Dst:
Aux Aux
S
pec
ifi
es
th
e ne
t
wor
k
d
es
ti
na
ti
on
for Trap Manager
n
.
FDL FDL
EDL
n
EDL
n
Disab Disab
Gen Trap:
Warm Warm Specifies the general trap types to
enable: WarmStart Authentication
Gen Trap:
Auth Auth
pgpyp
enable: WarmStart, Authentication
Failure or both.
Both Both
Failure
or
both
.
Entp Trap:
Enab Enab
Specifies whether the
EnterpriseSpecific trap type is
Entp Trap:
Disab Disab
p
EnterpriseSpecific trap type is
enabled.
Disab Disab
Link Trap:
Up Up Specifies the link trap type to
enable: Trap on Link Up Link
Link Trap:
Down Down
ppyp
enable: Trap on Link Up, Link
Down, or both.
Both Both
Down
,
or
both
.
NET NET
DTE DTE
When any link trap types are
Trap I/F:
T1s T1s
When any link trap types are
enabled, specifies which links to
send traps for
Trap
I/F:
Ports Ports
,p
send traps for.
All All
18
Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or
included in the manual.
2. This product is intended to be used with a 3-wire grounding type plug – a plug
which has a grounding pin. This is a safety feature. Equipment grounding is vital to
ensure safe operation. Do not defeat the purpose of the grounding type plug by
modifying the plug or using an adapter.
Prior to installation, use an outlet tester or a voltmeter to check the ac receptacle
for the presence of earth ground. If the receptacle is not properly grounded, the
installation must not continue until a qualified electrician has corrected the problem.
If a 3-wire grounding type power source is not available, consult a qualified
electrician to determine another method of grounding the equipment.
3. Slots and openings in the cabinet are provided for ventilation. To ensure reliable
operation of the product and to protect it from overheating, these slots and
openings must not be blocked or covered.
4. Do not allow anything to rest on the power cord and do not locate the product
where persons will walk on the power cord.
5. Do not attempt to service this product yourself, as opening or removing covers may
expose you to dangerous high voltage points or other risks. Refer all servicing to
qualified service personnel.
6. General purpose cables are provided with this product. Special cables, which may
be required by the regulatory inspection authority for the installation site, are the
responsibility of the customer.
7. When installed in the final configuration, the product must comply with the
applicable Safety Standards and regulatory requirements of the country in which it
is installed. If necessary, consult with the appropriate regulatory agencies and
inspection authorities to ensure compliance.
8. A rare phenomenon can create a voltage potential between the earth grounds of
two or more buildings. If products installed in separate buildings are
interconnected, the voltage potential may cause a hazardous condition. Consult a
qualified electrical consultant to determine whether or not this phenomenon exists
and, if necessary, implement corrective action prior to interconnecting the products.
9. Input power to the ac voltage configuration of this product must be provided by a
UL-listed or CSA-certified power source with a Class 2 or Limited Power Source
(LPS) output. Input power to the dc voltage configurations of this product must be
provided by a National Electric Code (NEC) or a Canadian Electric Code (CEC)
Class 2 circuit.
10. This product contains a coin cell lithium battery that is only to be replaced at the
factory. Caution: There is a danger of explosion if the battery is incorrectly
replaced. Replace only with the same type. Dispose of used batteries according to
the battery manufacturers instructions. Attention: Il y a danger d’explosion s’il y a
remplacement incorrect de la batterie. Remplacer uniquement avec une batterie du
même type. Mettre au rebut les batteries usagées conformément aux instructions
du fabricant.
/