titelseite_neu_a5.fm Seite 1 Dienstag, 22. Februar 2005 4:43 16
10 11
GBGB
cable cross section (mm
2
)
12 V-units
24 V-units
extension meters (m)
Battery operation
Your cooling device can be operated with 12 or 24 volt direct voltage. Prior to
connection check wether the voltage indication on the type plate is in accordance
with the battery voltage.
Connect your cooling device as directly as possible to the poles of the battery or to
a plug connection with an at least 15 A fuse.
Pay attention that the plus wire is connected on to the positive pole and the minus
one to the negative pole. In order to avoid loss of voltage and thus decrease of
performance, the cable should be as short as possible and not interrupted. For
this reason avoid additional switches, plugs or feeder boxes.
If the connecting cable is too short or does not belong to the delivery scope of your
model, you have to buy an corresponding cable or an extension by specialized
dealers. Determine the required cable cross section by means of the following
schedule:
Here you find the necessary wire cross section
Note: High-speed battery chargers may only be connected to the battery
after the cooling device and all other consumers have been disconnected
from the battery. Overvoltage could cause damage to the electronics of the
units.
Your cooling device is equipped with a reverse battery protection. It protects your
cooling device against reverse battery by battery connection and against short circuit.
As a protection for your battery, the cooling device switches off automatically if the
voltage is not sufficient.
You will find the cut-out/cut-in voltages in the Technical data.
Mains operation
If possible, always connect your device to the A.C. network with MOBITRONIC
rectifiers.
Safety instructions
Never touch naked lines with bare hands. This applies above all to operation on
A.C. network: Danger!
In case of boats: if the devices are mains operated, take care that the power supply
is fitted with a fuse protection over an FI-switch: Danger!
Installation works in wet rooms should be performed by a specialist!
Disconnect your cooling device and other consumers from the battery before
connecting a high-speed battery charger!
Compare the voltage indication on the type plate with the existing power supply.
Never open the cooling circuit!
If you connect your cooling device to a battery, never forget that the battery
contains some acid.
The cooling device is not appropriate for transporting corrosive or solvent-
comprising substances.
Never cover the ventilations!
Defrost the cooling device in time.
Never use hard or sharp tools for removing the ice coat or loosing frozen objects.
Never use sand-, acid- or solvent-comprising cleaning agents to clean the cooling
tank.
•Your device must be disposed by a specialist.
The safety indications in the text are marked with this symbol:
General
Application and operative range
The cooling device is fitted for refrigerating and deep-freezing food. When you wish
to refrigerate medicines, first check if the refrigerating capacity of the unit meets the
demands of the respective remedies. The device is suitable for ambient temperatures
between -20° and +55° Celsius and an air humidity of max. 90% in continuous
operation. The cooling device can bear a continuous lopside of maximal 30 degrees.
Before the cooling device is exposed to extreme working conditions – such as
expeditions – you should contact the producer. All materials which are used in the
device are generally recognized as safe for food. The cooling circuit is CFC-free.
Installation
After unpacking the device check that no parts are missing (see folding table).
Special accessories are marked with a ”S”.
Place the cooling device in a dry place which is protected against splash water. It
should not be placed directly adjacent to sources of heat such as heating, gas oven,
hot-water pipes or under the blazing sun. The cooling device must be installed in
such a way that the air which is warmed up through the condenser can escape
without problems.
manual 4445100015 28.03.2002 16:04 Uhr Seite 10
12 13
GBGB
Attention, danger! Never manipulate plugs or switches with wet hands or
when your feet are contacted with water! If you operate your cooling device
on board of a boat by means of shore connection to 230-V-network, you
must in any case insert a FI-safety switch. Contact a specialist for advice!
Cleaning
Your cooling device will be delivered cleaned from the factory – you nevertheless
should wipe it out a little bit previous to first use. Take a cloth which has been slightly
moistened with lukewarm water. Pay attention that no water drops into the seals
and possibly damages the electronics. Dry off the cooling device with a cloth after
cleaning. Clean the device periodically and as soon as it is dirty.
Attention: Never use solvent agents or agents with sand or acid parts for
cleaning the cooling tank!
Never use brushes, graters or hard and sharp tools.
Initial operation
Switch on the cooling device by rotating the switch button clockwise (see ”B” on the
folding table). By rotating the button forward, you can regulate the temperature.
Units with energy accumulator additionally have a knob to activate the storage (see
position ”C” on the folding table). With the energy accumulator refrigerating energy
can be stored up to 8 hours. The activation of the stored energy will be done auto-
matically when the cut-out voltage is reached (see technical data) or when the knob
”C” is pushed mechanically. The energy accumulator will be automatically loaded
again as soon as the cut-in voltage is exceeded or the energy accumulator is
unloaded and it will be mechanically loaded again when the thermostatknob (”B”)
is rotated by means of which the knob to activate the storage is unlocked.
Putting out of service
If you want to cut out the cooling device for a longer period, draw off the plug of the
A.C. line or disconnect the cooling device cable from the battery. Clean the cooling
device and leave the lid or the door slightly open. Thus prevent the formation of
smells.
Defrosting
Air humidity can deposit on the evaporator or in the interior of the cooling device
as frost so that the refrigerating performance is reduced. In order to remove the ice
coat never use hard or sharp tools which can cause damage to the plastics or the
evaporator.
Therefore defrost the cooling device in good time. Take out the refrigerated products
and store them in another cooling device so that they remain refrigerated. Set the
switch button on ”0” and leave the lid or the door open. Wipe the condension water
or – if existing – empty the drip basin.
Tips for energy saving
The mounting place should be cool, well ventilated and protected against
sunbeams.
First let warm food get cold, before you store it.
Defrost your cooling device as soon as an ice coat has been formed.
•Avoid a too cold internal temperature!
Do not open the cooling device more often than necessary!
Do not leave the lid or the door open any longer than necessary!
Specific information
Fixing possibilities
We recommend special fixing kits tailored to each cool box version for fixing the box
optimally.
If required, please order separately!
Cool box Fixing kit
FF-20 Art.-No.: W2087.ST
FF-30 Art.-No.: W1440.ST
FA-30 Art.-No.: W1440.ST
FF-40 Art.-No.: W1440.ST
FA-40 Art.-No.: W1440.ST
FC-30 Art.-No.: W1440.ST
FC-40 Art.-No.: W1440.ST
FT-30 Art.-No.: W1627.ST
Vehicle specific fixing kits on demand.
Battery controller ”D”
The cool box is equipped with a battery controller cutting out and cutting in the
compressor and thus protecting battery and compressor.
The following schedule indicates the cut-out and cut-in voltages, measured at the
connecting terminals of the battery controller!
Cut-out voltage Cut-in voltage
12 V/24 V 12 V/24 V
low 10,4 V low 22,8 V low 11,7 V low 24,2 V
high 11,3 V high 24,6 V high 12,5 V high 26,0 V
manual 4445100015 28.03.2002 16:04 Uhr Seite 12
14 15
GBGB
585 340
346 271
408
320
FC-30
480
341
405
401
326
345
FT-30
585 340
271
346
400
484
FC-40
FF-90
* Re = Refrigeration / Df = deep-freeze
ti = interior temperature / ta = ambient temperature
550
300
260
200
425
345
FF-20
585 340
271
346
400
484
FF-40/FA-40
585 340
346 271
408
320
FF-30/FA-30
390
465
494
594
786
173
500
450
355
FF-70
Specifications
Exterior made in grey coated sheet steel; bottom and cover
grained grey polystyrol. Recessed handle grips and cup
holders. Insulated with 30 mm solid polyurethan foam;
FF-70/FF-90: insulated with 50 mm solid polyurethan foam.
Desig- Capacity Cooling Temperature Weight Average Battery Running time per hour Finish System Standard Accessories:
nation range power con- load at ti* = +5°C and equipment Plastic coated
sumption per h ta* = 20°C (32° C)* basket
FF-20 20 ltr. 18 kg 45 W 18% (28%) W2086.3
FF-30 30 ltr. 18 kg 45 W 20% (30%) W529.3
FA-30 20 ltr. 19 kg 45 W 15% (25%)
FF-40 37.5 ltr. 20 kg 45 W 23% (33%) W2995.3
FA-40 37.5 ltr. 21 kg 45 W 18% (28%)
FF-70 70 ltr. 25 kg 65 W 30% (40%)
FF-90 90 ltr. 28 kg 65 W 35% (45%)
FC-30 30 ltr. 18 kg 45 W 20% (30%) W529.3
FC-40 37.5 ltr. 20 kg 45 W 23% (33%) W2995.3
FT-30 30 ltr. 18 kg 45 W 20% (30%) W529.3
direct
evaporator
Re/Df
+5°C to -15° C
direct
evaporator
Re/Df
+5°C to -15° C
direct
evaporator
Re/Df
+5°C to -15° C
direct
evaporator
Re/Df
+5°C to -15° C
direct
evaporator
Re/Df
+5°C to -15° C
direct
evaporator
Re/Df
+5°C to -15° C
direct
evaporator
Re/Df
+5°C to -15° C
direct
evaporator
Re/Df
+5°C to -15° C
energy
accumulator
Re
+10°C to 0° C
energy
accumulator
Re
+10°C to 0° C
average power consumption × percentage running time
Fully hermetic DANFOSS BDF-compressor with electronic
control equipment and integrated undervoltage protection
for 12/24 Volt DC. Alu-rollbond evaporator (FF) or aluminium
energy accumulator. Variable automatic thermostat with
activation of energy accumulator (FA).
FF-70/FF-90: AC/DC converter (100-240V)
FF-20, FF/FA-30, FF/FA-40, FC-30, FC-40 and FT-30:
DC connection cable and user’s manual
FF-70 and FF-90:
DC and AC connection cable,
wire basket, mountable handles, user’s manual.
manual 4445100015 28.03.2002 16:04 Uhr Seite 14
Europe
Dometic Austria GmbH
Neudorferstrasse 108
2353 Guntramsdorf
+43 2236 908070
+43 2236 90807060
Dometic Switzerland AG
Riedackerstrasse 7a
CH-8153 Rümlang (Zürich)
+41 44 8187171
+41 44 8187191
Dometic Denmark A/S
Nordensvej 15, Taulov
DK-7000 Fredericia
+45 75585966
+45 75586307
Dometic Spain S.L.
Avda. Sierra del Guadarrama, 16
E-28691 Villanueva de la Cañada
Madrid
+34 902 111 042
+34 900 100 245
Dometic S.N.C.
ZA du Pré de la Dame Jeanne
F-60128 Plailly
+33 3 44633500
+33 3 44633518
Dometic Finland OY
Mestarintie 4
FIN-01730 Vantaa
+358 20 7413220
+358 9 7593700
Dometic Italy S.p.A.
Via Virgilio, 3
I-47100 Forlì
+39 0543 754901
+39 0543 756631
Dometic Norway AS
Skolmar 24
N-3232 Sandefjord
+47 33428450
+47 33428459
Mail: firmapost@waeco.no
Dometic Benelux B.V.
Ecustraat 3
NL-4879 NP Etten-Leur
+31 76 5029000
+31 76 5029090
Dometic Scandinavia AB
Gustaf Melins gata 7
S-42131 Västra Frölunda
(Göteborg)
+46 31 7341100
+46 31 7341101
Dometic UK Ltd.
Dometic House · The Brewery
Blandford St. Mary
Dorset DT11 9LS
+44 844 626 0133
+44 844 626 0143
A
CH
DK
E
F
FIN
I
N
NL
S
UK
Overseas + Middle East
Dometic Australia
1 John Duncan Court
Varsity Lakes QLD 4227
+61 7 55076000
+61 7 55076001
WAECO Impex Ltd.
Suites 2207-2211 · 22/F · Tower 1
The Gateway · 25 Canton Road
Tsim Sha Tsui · Kowloon
Hong Kong
+852 24611386
+852 24665553
Mail: info@dometic-waeco.com.hk
WAECO Impex Ltd.
Taipei Office
2 FL-3 · No. 56 Tunhua South Rd, Sec 2
Taipei 106, Taiwan
+886 2 27014090
+886 2 27060119
Mail: marketing@waeco.com.tw
Dometic AB
Regional Office Middle East
P O Box 74775
Dubai, United Arab Emirates
+971 4 321 2160
+971 4 321 2170
Dometic Marine Division
2000 N. Andrews Ave. Extension
Pompano Beach, FL 33069 USA
+1 954 973 2477
+1 954 979 4414
Mail: marinesales@dometicusa.com
AUS
HK
ROC
UAE
USA
Dometic WAECO International GmbH
Hollefeldstraße 63 · D-48282 Emsdetten
+49 (0) 2572 879-195 · +49 (0) 2572 879-322
Mail: info@dometic-waeco.de · Internet: www.dometic-waeco.de
D
www.dometic-waeco.com
4445100015 10/2010
adresse_A5_31.fm Seite 2 Donnerstag, 9. September 2010 11:10 11
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33

Dometic CoolFreeze FC Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI