Extech Instruments 380940 combines multimeter and clamp meter functionality in one device. It can be used to measure AC/DC voltage and current to a maximum of 600V and 400A respectively, as well as resistance up to 40MΩ. Additionally, it allows for continuity checks, frequency measurements up to 100kHz, and it can calculate power in watts. This meter is suitable for both professional and DIY electrical work.

Extech Instruments 380940 combines multimeter and clamp meter functionality in one device. It can be used to measure AC/DC voltage and current to a maximum of 600V and 400A respectively, as well as resistance up to 40MΩ. Additionally, it allows for continuity checks, frequency measurements up to 100kHz, and it can calculate power in watts. This meter is suitable for both professional and DIY electrical work.

UserGuide
TrueRMSAC/DCPowerClampMeter
Model380940
Model 38090A-EU-EN v1.0 2/14
2
Introduction
Congratulations on your purchase of the Extech 380940 True RMS Watt Clamp DMM. This
meter combines multimeter and clamp meter functionality in one convenient meter. Careful
useofthismeterwillprovideyearsofreliableservice.
Safety
1. NEVERexceedthespecifiedvoltage/currentmaximum
2. USEEXTREMECAUTIONwhenworkingwithhighvoltages.
3. DONOTmeasurevoltageifthevoltageonthe"COM"inputjackexceeds500Vaboveearth
ground.
4. NEVERconnectthemeterleadsacrossavoltagesourcewhilethefunctionswitchisinthe
currentmode.Doingsocandamagethemeter.
5. ALWAYSdischargefiltercapacitorsinpowersuppliesanddisconnectthepowerwhen
measuring.
6. ALWAYSturnoffthepoweranddisconnectthetestleadsbeforeopeningthebacktoreplace
thefuseorbatteries.
7. NEVERoperatethemeterunlessthe
backcoverandthebattery/fusedoorareinplaceand
fastenedsecurely.
InternationalSafetySymbols
Model 38090A-EU-EN v1.0 2/14
3
MeterDescription
1. Conductorundertest
2. ClampJaws
3. JawtriggerOpensthemeterjaws
4. ZERObuttonZeroestheDCAreading
5. Positiveinputjack(forredtestlead)
6. Functionselectdial
7. HOLDbuttonfreezesthedisplayedreading
8. MAX/MINbuttonPresstotrackandview
highestandlowestreadings
9. LCDDisplaywithfunctionindicatorsandbargraph
10. COMinputjack(forblacktestlead)
FunctionSelectSwitch
Model 38090A-EU-EN v1.0 2/14
4
Displayicons
 Lowbattery
DC Directcurrent
AC Alternatingcurrent
Minussign
AUTO Automaticrange(frequencyonly)
APO AutoPowerOFF
ZERO Zero/Relativefunction
HOLD HOLDfunction
MAX Highestreading
MIN Lowestreading
 Audiblecontinuity
V Voltageunitofmeasure
A Currentunitofmeasure
M Prefix
MEGA(millionsofunits)
k PrefixKILO(thousandsofunits)
 Ohm(unitofmeasureforresistanceandcontinuity
Hz Hertz(unitofmeasureforfrequency)
OL Overload(whenreadingexceeds4032)
Bargraphdisplay
The40segmentbargraphdisplayshownbelowisagraphicalinterpretationofthemeasurement.
ItisdisplayedunderthedisplaydigitsontheLCD.
Thebarsinthebargraphindicateapresenceofanelectronicsignal.Themorebarsshowing,the
higherthesignal.Thedigitsbelowthegraphhelpthe
userseehowmanybarsareshowing.If40
segmentsareshowing,thebarswillreachthe‘40’mark,if20barsareshowingthebarswill
reachthe‘20’mark.
Thebargraphistobeinterpretedbasedontherangethemeterisinwhilethemeasurementisbeingmade.
Ifthebargraphshows40segmentslit,thenthesignalisatthehighestendofthemeter’spresentrange.
Model 38090A-EU-EN v1.0 2/14
5
Operation
AC+DCPowerWattMeasurements
1. Connectthetestleadstothevoltagesourceinparallelwiththeload(refertodiagram).
2. Clampontooneofthewiresconnectedtotheload.
3. SelecttheACorDCvoltagerangeusingthefunctionselectswitchandcheckthevoltage
reading.
4. SelecttheACor
DCcurrentrangeusingthefunctionselectswitchandcheckthecurrent
reading.
5. SelecttheappropriateWattrangeusingthefunctionselectswitch.
6. ReadtheKWvalueontheLCD.
ACCurrentMeasurements
WARNING:Toavoidelectricshock,disconnectthetestleadsfromthemeterbeforemaking
currentmeasurements.
1. SettheFunctionswitchtotheACCurrentposition.
2. Pressthejawtriggerandclamparoundasingleconductorfullyenclosingit.Donotallowa
gapbetweenthetwohalvesofthejaw.
3. ReadtheACAvalueontheLCD.
Model 38090A-EU-EN v1.0 2/14
6
DCCurrentMeasurements
WARNING:Toavoidelectricshock,disconnectthetestleadsfromthemeterbeforemaking
currentmeasurements.
1. SettheFunctionswitchtotheDCCurrentposition.
2. PresstheDCAzerokeytonullthemeterdisplay.
3. Pressthejawtriggerandclamparoundasingleconductorfullyenclosingit.Donotallowa
gapbetweenthetwohalvesofthejaw.
4. ReadtheDCA
valueontheLCD.
ACVoltageMeasurements
WARNING:Toavoidelectricshockordamagetothemeter,donotmakeanyvoltage
measurementsthatexceedthemaximumspecified.
1. SettheFunctionswitchtotheACVoltageposition.
2. Insertthetestleadstothemeterasfollows:Redleadto“V,,Hz”terminal;Blackleadtothe
COMinput.
3. Measurevoltagewiththepointedendofthetestleads.Rememberthatvoltage
measurementsaremadeinparallelwith
thedevice/circuitundertest.
4. ReadtheACVvalueontheLCD.
DCVoltageMeasurements
WARNING:Toavoidelectricshockordamagetothemeter,donotmakeanyvoltage
measurementsthatexceedthemaximumspecified.
1. SettheFunctionswitchtotheDCVoltageposition.
2. Insertthetestleadstothemeterasfollows:Redleadto“V,,Hz,”terminal;Blackleadtothe
COMinput.
3. Withthepointedendofthetestleadsmeasurevoltage.Rememberthatvoltage
measurementsaremadeinparallel
withthedeviceorcircuitundertest.
4. ReadtheDCVvalueontheLCD.
FrequencyMeasurements
1. SettheFunctionswitchtotheHzposition.
2. Insertthetestleadsintothemeter’sinputterminals.
3. Connecttheotherendsofthetestleadsinparallelwiththedevice/circuitundertest.
4. ReadtheFrequencymeasurementontheLCDinHz.
Model 38090A-EU-EN v1.0 2/14
7
MIN,MAXFunction
PressingtheMIN/MAXkeyallowsthemetertodisplayONLYthehighestandthelowest
readingsencountered.PresstheMIN/MAXkeyoncetoviewtheminimumreading,pressit
againtoviewthemaximumreading.TheLCDwilltogglebetweentheMINandMAXvalues.
PressandholdMIN/MAXbuttonfor
morethan2secondstoreturntonormaloperating
mode.ZerofunctionwillbedisabledwhenMIN/MAXisenabled.MIN/MAXisnotavailablein
Hzmode.
DataHold
TofreezethecurrentreadingontheLCD,presstheDataHoldkey.ToreleasetheDataHold
functionandreturnthemetertonormaloperation,presstheDataHoldkeyagain.
RelativeMode
1) PresstheZEROkey.ThedisplayedreadingwillzeroandthewordZEROwillappearonthe
upperportionoftheLCD.
2) Allsubsequentmeasurementswillnowbedisplayedwithrespecttothezeroedreading.For
example,ifa20Areadingiszeroedanda30Areadingissubsequently
measured,theLCDwill
display10A.
3) Pressthezerobuttononcemoretoreturntonormaloperatingmode.
4) NotethatRelativemodeisnotavailableifMIN/MAXmodeisenabled.
5) LCDdisplaysrelativenumericalvaluewithoutbargraph.
Model 38090A-EU-EN v1.0 2/14
8
AutoPowerOFF
Toextendbatterylife,themeterwillautopoweroffafter15minutesofoperation.Toresume
operationeitherturnthemeterOFFandthenONagainorpresstheHOLDbutton.
BatteryReplacement
1. WhenthelowbatterysymbolappearsontheLCD,thebatteriesmustbereplaced.
2. Turnthemeteroffandremovetherearbatterycompartmentscrew.
3. Liftoffthebatterycompartmentcoverandreplacethetwo1.5VAAcells.
4. Replacethecompartmentcoverandsecurethescrew.
You,
astheenduser,arelegallybound(Batteryordinance)toreturnallusedbatteries
andaccumulators;disposalinthehouseholdgarbageisprohibited!
Youcanhandoveryourusedbatteries/accumulatorsatcollectionpointsinyour
communityorwhereverbatteries/accumulatorsaresold!
Disposal:Followthevalid
legalstipulationsinrespectofthedisposalofthedeviceat
theendofitslifecycle
Cleaning
Useonlyadryclothtocleantheplasticcase.
Model 38090A-EU-EN v1.0 2/14
9
Specifications
GeneralSpecifications
Display 33/4digit(4032count)LCDwith40segmentbargraph
Functions Watts,ACA,DCA,ACV,DCV,Frequency
Polarity indicatesnegativepolarity;positiveassumed
Currentsensor Halleffectsensortype
Overloadindication OL
DCAzeroadjust Onetouchzerokey
Displayrate 3readings/second(30readings/secondforbargraph)
AutoPowerOff Meterturnsoffautomaticallyafter15minutes
Battery Two1.5VAAbatteries
Operatingtemp.‐10
0
Cto50
0
C(4
0
Fto122
0
F)
OperatingHumidity <85%RH
Powerconsumption Approximately10mADC
Weight 190g(6.7oz)includingbattery
Dimensions 183x63.6x35.6mm(7.2x2.5x1.4”)(HWD)
Jawopening 23mm(0.9”)maximumconductorsize
Standards IEC1010CategoryIII300V,CategoryII600V
Model 38090A-EU-EN v1.0 2/14
10
RangeSpecifications
Function Range Resolution Accuracy Overloadprotect
ACPower 40kW 10W ±(1.5%+3dgts) 250V,400A
Note:50/60Hz,PF0.6to1,Vpeak<360V
240kW 100W ±(1.5%+3dgts) 600V,400A
Note:50/60Hz,PF0.6to1,Vpeak<850V
40kW 10W ±(2.5%+3dgts) 250V,400A
Note:40Hzto100Hz,PF0.6to1,Vpeak<360V
240kW 100W ±(2.5%+3dgts) 600V,400A
Note:40Hzto100Hz,PF0.6to1,Vpeak<850V
DCPower 40kW 10W ±(1.5%+3dgts) 250V,400A
240kW 100W ±(1.5%+3dgts) 600V,400A
DCCurrent 400A 100mA ±(1.5%+3dgts) 600ADC
ACCurrent
TrueRMS,
Crestfactor<
4
50/60Hz 40to100Hz
400A 100mA ±1.5%±3dgts ±2.5%±4dgts 600AAC
DCVoltage 400V 0.1V ±(1.0%+2dgts) 800VDC
ACVoltage
TrueRMS,
Crestfactor<
4,Input
impedance
10MΩ
50/60Hz 40to1kHz
600V 1V ±(1.5%+2dgts) ±(2.0%+4d) 800VAC
Frequency 1Hz‐
100kHz
0.001‐
100Hz
±(0.8%+2dgts) Sensitivity10V 600VAC
Copyright©2014FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
www.extech.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Extech Instruments 380940 User manual

Category
Multimeters
Type
User manual

Extech Instruments 380940 combines multimeter and clamp meter functionality in one device. It can be used to measure AC/DC voltage and current to a maximum of 600V and 400A respectively, as well as resistance up to 40MΩ. Additionally, it allows for continuity checks, frequency measurements up to 100kHz, and it can calculate power in watts. This meter is suitable for both professional and DIY electrical work.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI