Lovibond 2438235: Universal laboratory incubator with precise temperature control for various applications in microbiology, food industry, and research. Temperature range from 2 to 40°C adjustable in 0.1°C increments. Features corrosion-proof temperature probe, 2 axial flow fans, and a digital display. Ensures accurate and reliable temperature regulation.

Lovibond 2438235: Universal laboratory incubator with precise temperature control for various applications in microbiology, food industry, and research. Temperature range from 2 to 40°C adjustable in 0.1°C increments. Features corrosion-proof temperature probe, 2 axial flow fans, and a digital display. Ensures accurate and reliable temperature regulation.

www.lovibond.com
Lovibond
®
Water Testing
Tintometer
®
Group
TC 140 G / TC 256 G
Thermostatschränke TC-Serie
GB
Instruction Manual
Page 10 – 17
Thermostatschränke
Vor Inbetriebnahme die Gebrauchsanweisung lesen
Thermostatically controlled incubators
Read the operating instructions before switching on for the first time
Etuves réfrigérées
Lire le mode d'emploi avant la mise en service
Armarios termostaticos
Leer las instrucciones de manejo antes de la puesta en servicio
Estufas reguladas por termóstato
Antes da colocação em funcionamento, ler o manual de utilização
TC 140 G / TC 256 G_1 04/2014
10
Safety instructions and warnings
•Topreventinjuryordamagetotheunit,theapplianceshouldbe
unpackedandsetupbytwopeople.
•Intheeventthattheapplianceisdamagedondelivery,contact
thesupplierimmediatelybeforeconnectingtothemains.
•Toguaranteesafeoperation,ensurethattheapplianceissetup
andconnectedasdescribedintheseoperatinginstructions.
•Disconnecttheappliancefromthemainsifanyfaultoccurs.Pull
outtheplug,switchofforremovethefuse.
•Whendisconnectingtheappliance,pullontheplug,notonthe
cable.
•Anyrepairsandworkontheapplianceshouldonlybecarriedout
bythecustomerservicedepartment,asunauthorisedworkcould
provehighlydangerousfortheuser.Thesameappliestochanging
themainspowercable.
•Donotallownakedflamesorignitionsourcestoentertheappli-
ance.Whentransportingandcleaningtheappliance,ensurethat
therefrigerantcircuitisnotdamaged.Intheeventofdamage,
make sure that there are no ignition sources nearby and keep the
roomwellventilated.
•Donotstandontheplinth,drawersordoorsorusethemtosup-
portanythingelse.
•Thisappliancecanbeusedbychildrenof8yearsoldandover,and
alsobypersonswithrestrictedphysical,sensoryormentalcapacity
orlackofexperienceandknowledge,iftheyaresupervisedor
have been instructed on safe use of the appliance and understand
theresultingrisks.Childrenmustnotbeallowedtoplaywiththe
appliance.Cleaningandusermaintenancemustnotbecarried
outbychildrenwithoutsupervision.
•Avoidprolongedskincontactwithcoldsurfacesorchilled/frozen
food.Thiscouldcausepain,numbnessandfrostbite.Inthecase
ofprolongedskincontact,protectivemeasuresshouldbetaken,
e.g.glovesshouldbeworn.
•Donotstoreexplosivesorspraysusingcombustiblepropellants
suchasbutane,propane,pentane,etc.intheappliance.Electrical
componentsmightcauseleakinggastoignite.Youmayidentify
suchspraysbytheprintedcontentsoraflamesymbol.
•Ifyouhavealockableappliance,donotkeepthekeynearthe
applianceorwithinreachofchildren.
•Theapplianceisdesignedforuseinenclosedareas.Donotoperate
theapplianceoutdoorsorinareaswhereitisexposedtosplash
waterordampconditions.
•Donotplaceitemswithtoohightemperatureintheinterior.
Disposal notes
The appliance contains reusable materials and should be
disposedofproperly-notsimplywithunsortedhousehold
refuse.Applianceswhicharenolongerneededmustbe
disposedofinaprofessionalandappropriateway,in
accordancewiththecurrentlocalregulationsandlaws.
Whendisposingoftheappliance,ensurethattherefrigerantcircuit
is not damaged to prevent uncontrolled escape of the refrigerant
itcontains(dataontypeplate)andoil.
Do not vent R134a into atmosphere.
R134a is a fluorinated greenhouse gas, covered by
Kyoto Protocol, with a Global Warming Potential
(GWP) = 1300.
•Disabletheappliance.
•Pulloutthemainsplug.
•Cutthroughtheconnectioncable.
•Disablesafetylock.
WARNING
Dangerofsuffocationduetopackingmaterialandplasticlm!
Donotallowchildrentoplaywithpackagingmaterial.Takethe
packagingmaterialtoanofcialcollectionpoint.
Range of appliance use
Thethermostat-controlledincubatorsaredesignedtoallowcontinu-
ousregulationoftemperatureforvariousfieldsofapplication,e.g.
•20°CBOD
5
measurement
andresearchpurposesat:
•4°Cstorageofsewagesamples
•25°Cenzymeactivity(TTC-test)
•37°Ccolonycount
•Microbiology
•Foodindustry
•Laboratories
Alltemperaturecontrolproblemsintheusualrangeof2°Cto40
°Caresolvedbythefactorysetuniversalplug-incontrollerwhich
ismaintenance-freeandreliable.Thisapplianceisnotsuitablefor
storingflammableliquids,acidsandlyes.
Function
The inner temperature of the fully insulated incubator is controlled
exactlybyanintergratedcorrosion-prooftemperatureprobewhich
connects or switches-off either the cooling unit or the heating
element.
Themeasuredinnertemperatureisdirectlyindicatedbyadisplay.
Thetemperaturerangeof2°Cto40°Ccanbesetinincrements
of0,1°Cwiththeaidoftwotactileresponsekeys.Thekeyboardis
protectedbyaruggedfoil.Aircirculationisprovidedby2axialflow
fanswithadischargewidthof160cm
2
and an output of 300 m
3
/h.
Noise emissions from the appliance
Thenoiselevelwhiletheapplianceisoperatingisbelow70dB(A)
(relativenoiselevel1pW).
Climate rating
The climate rating indicates the room tempera-
tureatwhichtheappliancemaybeoperatedin
ordertoachievefullrefrigerationperformance.
Theclimateratingisindicatedonthetypeplate.
Climate rating Room temperature
4 (SN) +10°C to +32°C
4 (N) +16°C to +32°C
4+ (ST) +16°C to +38°C
4+ (SN-ST) +10°C to +38°C
5 (T) +16°C to +43°C
5 (SN-T) +10°C to +43°C
Do not operate the appliance outside the speci-
fied room temperature range.
TC 140 G / TC 256 G_1 04/2014 11
GB
Setting up
•Donotplacetheapplianceindirectsunlightornear
cookers,radiatorsandsimilarsourcesofheat.
•Theflooronwhichtheappliancestandsshouldbe
horizontalandlevel.Compensateforunevenfloors
withtheadjustablefeet.
•Donotcoverventilationopeningsor
grille.
•Always install the appliance directly
againstthewall.
•Wellventilatedrooms
Appliance dimensions
A B C D E
TC 140 G 850 mm 600 mm 600 mm 648 mm 1153 mm
TC 256 G 1640 mm 600 mm 610 mm 650 mm 1180 mm
Installing beneath a worktop TC 140 G
F o rc o nt inu ou sw o rk to ps t he r efr ig e r a to r s t a b le t op c an b ed et a c he d .
Therefrigeratorcanthenbepushedundertheexistingworktop.
•Totakeofftabletopremovescrews.
• A cross-section of min. 200 cm
2
is required in the
worktopforventilationoftherearoftheappliance.
Electrical connection
Onlyoperatetheappliancewithalternating current (AC).
Thepermissiblevoltageandfrequencyareindicatedonthetypeplate.
Thesocketmustbeproperlyearthedandprotectedbyafuse.
Thetrippingcurrentofthefusemustbebetween10Aand16A.
The socket must not be situated behind the appli-
anceandmustbeeasilyaccessible.
Donotconnecttheapplianceusinganexten-
sioncableorextensionsocket.
Donotusestand-aloneinverters(conversionof
directcurrenttoalternatingcurrent/three-phase
current)orenergy-savingplugs.Riskofdamage
totheelectroniccontrolsystem!
Safety lock TC 140 G
Thelockintheappliancedoorisequippedwithasafetymechanism.
Locking the appliance
•Insertthekeyasshownby
arrow1.
•Turnthekey90°.
Tounlocktheappliance,thesame
procedure must be repeated in the
sameorder.
Safety lock TC 256 G
Thelockintheappliancedoorisequippedwithasafetymechanism.
Locking the appliance
•Insertthekeyasshownby
arrow1.
•Turnthekey90°.
Tounlocktheappliance,thesame
procedure must be repeated in the
sameorder.
Important
TC 140 G, TC 256 G
Themaximumloadpergridshelfis45kg.
Important
Whenunpackingandsettingupuseprotectivegloves.
TC 140 G / TC 256 G_1 04/2014
12
Adjustment and operation
TheunitisswitchedonandoffviatheOn/Offswitch.
The „Up key is used to increase the temperature
The Down“ key is used to decrease the temperature
Theillustrationshowstheactual
temperatureof20.0°C.
Setting the temperature values
Whentheunitisswitchedon,thedisplaywillinitiallyshowbriey
thetypeofovenandaversionnumber.It will then displaythe
preset temperature,together with the symbol forthe specied
gure(3horizontallines).After5seconds,thiswillbereplacedby
thecurrent,actualtemperature.
Theunitispresetinthefactorytoaworkingtemperatureof20°C.
Ifthisisrequiredtobe25°C,forexample:
Pressthe„“keyonce.Thedisplaywillshowthespeciedgure
whichhasbeenset, togetherwiththesymbolforthespecied
gure (3 horizontal lines). Now press the “ key again, or
hold it down until the display shows the new gure required
(25°Cinthisexample).Thenreleasethekey.Thedisplaywillshow
the new setting for 5seconds and willthen displaytheactual,
currenttemperature.
Ifalowerworkingtemperatureisrequired,thesameprocedure
applies,usingthe“key.Thetemperaturecanbeadjustedin
stepsof0.1°Cbetween2°Cand40°C.
Ifyouwishtoreadthespeciedtemperaturebutwithoutchanging
it,simplypresstheor„“keyonceandreleaseit,sothatthe
displayshowsthespeciedgureinsteadofthecurrenttemperature.
Thespeciedgurecannotbechangedunlessoneofthekeysis
pressedwhilethedisplayisalreadyshowingthespeciedgure.
Thepresettemperaturewillnotbelostifthereisapowerfailure
ofiftheunitisswitchedoff.Thedataarestoredinaninternal
electronicmemoryandarecalledupautomaticallywhenpoweris
restoredortheunitisswitchedon.
Detecting a power failure
Whentheunitisrstswitchedon,thedisplaywillash.Pressing
the„“or“keywillcauseittostopashingandremainper-
manentlylit.
Ifthereisapowerfailure,thedisplaywillstarttoashagain.Thismay
indicate that the temperature in the oven can no longer be held at
theworkingtemperature,ifthepowerisoffforanextendedperiod.
Thecontrolswillcontinuetooperatenormally,evenifthedisplay
isashing.The ashingmerelyindicatesthattheunit hasbeen
switchedoffandthenbackonagain,orthatthepowersupply
failedforatimeandnokeyhasbeenpressedsincethen.
Itisimportanttonotethatthedisplaywillash,evenifthepower
supplyhasfailedforaveryshortperiod.Itdoesnotnecessarily
meanthatthetemperatureintheovenhasdeviatedsignicantly
fromthespeciedlevel.
Temperature control and accuracy
Thethermostaticallycontrolledincubatorsarenotspeciedaccor-
dingASTM E 145 (9-point-measurement) orDIN12880, part 2
(27-point-measurement).
Specicationsarebasedonaone-point-measurement.
Test procedure
1. Placeasamplebottlelledwith500mlwaterwithastirring
rodonastirringplaceandplaceitinthemiddleofagrid(5th
insertfromthebottom).
2. Completelyimmersetheprobeofthemeterinthewatersample
(accordingtothespecicationsofthemeter).Theprobeshould
nottouchthebottlewall.
Specicationsofthemeter: Accuracyatleast0.5°C
Resolutionatleast0.1°C
3. Thetemperatureisreadafter4hours.
Trouble shooting
Ifthevericationofthetemperatureaccuracyisnotsuccessfulthe
followingshouldbetakenunderconsideration:
- The ambient temperature of the thermostatically controlled
incubatormustmatchtheclimaterate(typeplate).
- Acertaincirculationofairisnecessaryforthecompressorto
workproperly.
- Theincubatorshouldnotbeopenedtooftenand/orforlonger
periodoftime.
- Checkthefunctionofthetwofansbyvisualinspection.
- Checkthecoolingdevicebysetting10°Candwaitforasigni-
cantchangeofthetemperatureinthesampletowards10°C.
- Checktheheatingdevicebysetting40°Candwaitforasigni-
cantchangeofthetemperatureinthesampletowards40°C.
- Dependingonthesampletemperatureitcantakeupto7hours
fortemperaturestabilityattheset-value.
Important
Theairtemperatureinthecabinetmayuctuatebyseveraldegrees
centigrade. Nevertheless the actual temperature of the sample
uctuatesonlybyamaximumof±0.5°C.
Other operation controls
On the front side of the temperature control unit there are
covered shock-proof sockets for the connection of BOD's
appliances or stirring apparates. The total load on the sockets
must not exceed 4,5 amps.
The thermostatically controlled oven and laboratory sockets are
protectedbyafuse(6.3AT)whichisaccessiblefromthefront
paneloftheunit.
Thecontrolunitisconnectedbymeansofa4-poleplugonthe
bottomoftheincubator.
TC 140 G / TC 256 G_1 04/2014 13
Cleaning
Clean the appliance at least twice per year.
Before cleaning always switch off the appliance. Pull out the
mains plug or switch off or unscrew the fuse.
•Clean the inside, equipment and outer walls with
lukewarmwaterandalittledetergent.Donotuse
abrasiveoracidcleanersorchemicalsolvents.
•Ensure that no cleaning water penetrates into the
electricalcomponentsorventilationgrille.
•Thedustshouldberemovedfromtherefrigeration
unitandheatexchanger-metalgridatthebackof
theappliance-onceayear.
•Donotdamageorremovethetypeplateonthein-
sideoftheappliance.Itisveryimportantforservicing
purposes.
•Important! The compressor and other parts may
stillbehotfromoperation.
Do not use steam cleaners because of the risk
of injury and damage.
Defrosting
Whenoperatingataverycoldthermostatsetting,theinteriorrear
wallmayiceup.
Inthiscase,theappliancemustbedefrostedmanually.
•Pull out the mains plug!
•Leavethedooroftheapplianceopenwhiledefrosting.
Defrostedwatercollectsinanevaporatortrayandis
evaporatedautomatically.Attentionmustbepaidthat
thedefrostedwatercandrainofffreelythroughthe
drainageopeninginthebackpaneloftheincubator.
The drainage opening should, when necessary be
cleanedwiththeaidofasuitabledevice(e.g.bottle
brush).Afterdefrostingmopuptheremainingwater
andcleantheappliance.
Do not use any mechanical devices or other
artificial aids for defrosting other than those
recommended by the manufactur er.
Shutting your appliance down
Ifyourapplianceistobeshutdownforanylengthoftime,switch
itoffanddisconnecttheplugorswitchofforunscrewthefuse.
Cleantheapplianceandleavethedooropeninordertoprevent
unpleasantsmells.
The permissible room temperature for storing the appliance
after decommissioning is between -10°C and +50°C.
Storing the appliance outside this temperature range can
damage the appliance and cause it to malfunction.
Theappliancecomplieswiththerelevantsafetyregulationsand
ECDirectives2004/108/ECand2006/95/EC.
Malfunctions
Ifamalfunctionoccursduringoperation,checkwhetheritisdue
toanoperatingerror.
You may be able to rectify the following faults yourself:
•Appliance does not function:
–Istheapplianceswitchedon?
–Istheplugcorrectlyfittedinthemainssocket?
–Isthefuseintact?Ifnecessary,replacewithanew6.3A(slow).
•Loud running noise:
–Istheappliancesetupfirmlyonthefloor?
–Doestheappliancecausenearbyitemsoffurnitureorobjectsto
vibrate?Pleasenotethatnoisescausedbytherefrigerantcircuit
cannotbeavoided.
•Correct display of inside temperature but no regulation to the
temperature setpoint:
–Isthetemperaturesettingcorrect(see"Settingthetemperature")?
–Istheventilationsystemworkingproperly?
–Istheappliancesetuptooclosetoaheatsource?
Ifnoneoftheabovecausesapplyandyoucannotrectifythefault
yourself.Contactyourdealerorsupplier,ifnecessarysendinthe
controlunitorthermostat-controlledincubatorforrepair(original
packingifpossible!).
GB
Changing over door hinges TC 140 G
•Unscrewhingebracket1.
•Pullthedooroutatthebottomandliftoff.
•Transfercover3 totheoppositeside.
•Transferhingepin2 on hinge bracket 1 to the op-
positeside.
•Transferhingepin4 totheoppositeside.
•Transferdoorhandle5 and plugs 6 totheotherside.
•Mountdooronhingepin4 andclose.
•Inserthingebracket1 inlowerdoormountingand
screwintoplace.
Important
Before undertaking any repair work disconnect plug from
mains! Only trained specialists should work on electrical
devices.
TC 140 G / TC 256 G_1 04/2014
14
Changing over door hinges TC 256 G
Door hinges should only be changed by a trained expert.
Changing the door hinges must be done by two people.
2. Openthedoorapprox.45°
andliftupwards.
Important
Asaresultofitsheavyweight,the
door must be held secure by one
person.
3. Pushthepinupwardsusing
yourfingertip.
4. Pull the door to the front
andremoveitdownwards.
1. Remove screw from
lowerhingebracket.
1
2
3
4
7.Insertthekey.
Turnthekey90°.
8. Removecover.
9. Removescrew.
10. Turnthelockapprox.
3°clockwise.
11.Removepin.
8
9
10
11
7
5
5. Transfer door handle and
plugstotheotherside.
6. Insertkey.
6
12. Removebushing.
13. Turn back the lock
90°anticlockwise.
12
13
TC 140 G / TC 256 G_1 04/2014 15
GB
16
16. Transfer covers to the
oppositeside.
17. Transfer plug and
bushing.
14.
Removelock.
15.
Reinsert hinge bush-
ing.
14
15
17
18. Removebushing.
19. Insertthelockasshown
intheillustration.
19
18
22. Turnthelockfurther-
approx.3°clockwise.
23.Insertpin.
Noteonpoint23
Afterinsertion,thepin'scrosspinmust
beengagedinthegrooveofthecatch.
24. Screw in the screw
and attach the cover
cap.
25.
Insertthekey.
Turnthekey90°.
20. Turnthelock90°clock-
wise.
21.
Reinsert hinge bush-
ing.
24
25
20
21
22
23
TC 140 G / TC 256 G_1 04/2014
16
31.Insertthepinintotheleft-handdoormount-
ing.
Useyourindexfingertoholdthepinwhile
youareassemblingthedoor.
32. Locate the door on the upper
pinasshownintheillustration
andguideittothelowerhinge
bracket.
Important
Asaresultofitsheavyweight,thedoor
mustbeheldsecurebyoneperson.
33.Liftthedoorupwardsandturn
the pin until it fits into the bore
holeofthehingebracket.
Slowly lower the door down-
wards.Thelowerpartofthepin
must be fully engaged in the bore
holeofthehingebracket.
34.Screwthescrewinto
the pin again and
tighten.
29.
Remotethecover,turnitthrough
180°andre-fititontheopposite
side.
28.
Unscrew hinge
bracket.
26. Unscrewthepin.
Usethespannerprovided.
27. Screwinthepinontheopposite
side.
30.
Screwhingebracketinto
place.
31
32
33
28
29
30
34
26
27
TC 140 G / TC 256 G_1 04/2014 17
Construction fully insulated incubator
withuniversalplug-in
temperature.Door,double
glazedinsulatedinABS
frame
Control unit operationrobust,waterprotectedfoil
frontpanel,2keyswith
tactileacknowledgement
Range of adjustment 2°Cto40°C,adjustablein
0.1°C-increments
Constancy of temp.
20°C,±1.0°C
Climate class
the climate rating is indicated
on the type plate
Display 3 digit for actual and target
temperature,resolution0.1°C
Refrigerating unit compressor-system
Heating unit heating element
Fan axial,discharge
capacity 320 m
3
/h
Power requirement
220-240V/50Hz
Sockets CEE7/5,typeE,withhinged
lid,230V/16A,2p+E,IP44
Coolant R134a
TC 140 G(4sockets)
Net capacity 140Ltr.
Power consumption 275VA
1.77kWh/24h
(ambienttemperatur25°C,
targettemperature20°Cwith
interiorlightingswitchedon)
Overall dimensions 600Wx600Dx850Hmm
withworktop
600Wx600Dx819Hmm
withoutworktop
Inside dimensions 513Wx441Dx702Hmm
(with3retractablegrids
and 1 bottom grid)
Weight 48.0kg
Order Code 2 43 82 10
TC 256 G(7sockets)
Net capacity 255Ltr.
Power consumption 340VA
1.56kWh/24h
(ambienttemperatur25°C,
targettemperature20°Cwith
interiorlightingswitchedon)
Overall dimensions 600Wx610Dx1640Hxmm
Inside dimensions 470Wx440Dx1452Hmm
(with4retractablegrids
and 1 bottom grid)
Weight 77.0kg
Order Code 2 43 82 35
Technical Data
GB
Adjusting the lateral tilt of the door
Ifthedoorisatanangle,adjusttheangle.
35.Remove middle screw from hinge
bracket.
Thisscrewisnolongerneeded.
36. Undo screws and slide
hinge bracket to the right
orleft.
Tightenscrews.
36
35
Technical changes without notice
Printed in Germany 04/14
No.: 00 38 56 85
Lovibond
®
and Tintometer
®
are Trademarks of the
Tintometer Group of Companies
Tintometer China
Room1001,ChinaLifeTower
16ChaoyangmenwaiAvenue,
Beijing,100020
Tel.:+861085251111App.330
Fax:+861085251001
China
Tintometer South East Asia
UnitB-3-12,BBTOneBoulevard,
LebuhNilam2,BandarBukitTinggi,
Klang,41200,SelangorD.E
Tel.:+60(0)333252285/6
Fax:+60(0)333252287
lovibond.asia@tintometer.com
www.lovibond.com
Malaysia
Tintometer GmbH
Lovibond
®
WaterTesting
Schleefstraße8-12
44287Dortmund
Tel.:+49(0)231/94510-0
Fax:+49(0)231/94510-20
sales@tintometer.de
www.lovibond.com
Germany
Tintometer AG
Hauptstraße2
5212HausenAG
Tel.:+41(0)56/4422829
Fax:+41(0)56/4424121
info@tintometer.ch
www.tintometer.ch
Switzerland
The Tintometer Limited
LovibondHouse/SolarWay
SolsticePark/Amesbury,SP47SZ
Tel.:+44(0)1980664800
Fax:+44(0)1980625412
water.sales@tintometer.com
www.
lovibond.com
UK
Tintometer Inc.
(dbaOrbeco-HelligeInc.)
6456ParklandDrive
Sarasota,FL34243
Tel:941.756.6410
Fax:941.727.9654
www.orbeco.com
USA
sales@novatech-usa.com
www.novatech-usa.com
Tel: (866) 433-6682 Fax: (866) 433-6684
Tel: (281) 359-8538 Fax: (281) 359-0084
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Lovibond 2438235 Owner's manual

Category
Fridges
Type
Owner's manual
This manual is also suitable for

Lovibond 2438235: Universal laboratory incubator with precise temperature control for various applications in microbiology, food industry, and research. Temperature range from 2 to 40°C adjustable in 0.1°C increments. Features corrosion-proof temperature probe, 2 axial flow fans, and a digital display. Ensures accurate and reliable temperature regulation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI