April identiti Inline Panel Installation Instructions Manual

  • Hello! I am an AI chatbot trained to assist you with the April identiti Inline Panel Installation Instructions Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
6
PH2 TYPE
3.2
INSTALLATION INSTRUCTIONS www.aprilproducts.co.uk
Tools Required
Lifetime Product Guarantee
ATTENTION!
Are you fitting this April enclosure to an April
shower tray?
The Lifetime Product Guarantee is only valid
when an April enclosure is fitted with an April
shower tray and are used and maintained in
accordance with the manufacturer’s instructions
(guarantee excludes seals and magnets).
When April enclosures are used with any other
shower tray the guarantee period is limited to
10 years.
Please see our website for full Terms &
Conditions.
To activate your Product Guarantee please visit
www.aprilproducts.co.uk and complete the
online form.
Inline Panel
This product should be installed by a suitably qualified and proficient person. The fitting instructions should be
followed carefully to ensure a proper and safe installation. Failure to follow these instructions could result in future
injury.
These instructions and list of parts assume that installation is done against solid/tiled walls.
Please check this product for damage prior to starting the installation. No claims can be made after the product has
been fitted.
PLEASE NOTE :The minimum and maximum adjustment sizes noted on the product brochures are based on
perfectly plumb walls and trays.
COMPONENTS AND BOX CONTENTS
Box Contents
Note: Further part details for fixing kit available on page 2
2
11
12
5
13
1
3
7 / 8
9
10
4
6
14
1
SN Code Descrip on Qty
1 ID2PF013 Inline Post 1
2 ID2PF017 Upright Prole 2
3 SNPF018 Cover Strip 1
4 ID2GS044 Glass Panel 1
5 SNFT038 Cover Strip Clip 5
6 ID2FT003 Upright Prole Cap 2
7 ID2FT012 Inline Post Cap - LH 1
8 ID2FT013 Inline Post Cap - RH 1
9 ID2FT044 Support Arm 1
10 SNFT046 Screw Cap 2
11 ID2FT045 Support Arm Glass Clamp 1
12 APTL001 Wall Plug 2
13 APTL008 Screw ST3.9×16 3
14 APTL005 Countersunk Screw ST4×30 2
2
IMPORTANT - Missing Components
Please check this product for missing components prior to installation.
For spare parts visit www.aprilproducts.co.uk
IMPORTANT - Installation site
1. Ensure the top surface of the shower tray on which the enclosure will be installed is level in every direction.
2. The tiles or other wall finishing should be effectively sealed at tray edges.
3. Tiles should extend at least to the corner of the tray and a minimum of 1.9 metres from the top of the tray.
FIXING KIT COMPONENTS, SITE CONDITIONS
Support arm
× 1
Inline Post
Top Cover Cap
× 2
Upright Profile
Top Cover Cap
× 1
Wall Plug
2 pcs
Countersunk
Tapping Screw
4 × 30
2 pcs
Round Head
Tapping Screw
3.9 × 16
3 pcs
FIXING KIT
Rail × 1
Glass Clamp × 2
Wall Fixing × 1
Countersunk Screw × 2
M6×14
M8 Socket Set Screw
With Rubber Tip × 2
5/32 Allen Key ×1
Screw Cover Cap
× 2
3
Step 2.
2.1 Remove the wall profiles and drill the marked points using a 6mm masonry drill bit, once this is done insert 6 × wall
plugs.
Step 1.3
Step 2.1
Step 1.1 & 1.2
Step 1.
1.1 Position the wall profiles to wall as shown (roughly 10mm from the front of the tray).
1.2 Level the frame using a spirit level.
1.3 Once you are happy that the frame sits on the tray correctly mark the wall through the 3 pre-drilled screw holes in the
wall profiles.
NOTE: You may find it easier to mark and drill the wall if you apply masking tape to it first.
10mm
10mm
4
Step 3.
3.1 Push the wall profile to the hinged side.
3.2 Push the inline panel to the other side of the hinge door.
3.3 Push the other wall profile to the inline panel.
Step 4.
Place the door to the tray again and fix the wall profiles
using screws ST3.9 × 30.
Step 5.
Adjust the frame to ensure that it is central between the wall profiles and inline post and level against the shower tray
at the base.
Step 3.3
Step 3.2
Step 3.1
Step 3.1 & 3.2 & 3.3
Step 4
Step 5Step 5
1
3
2
5
Step 6.
6.1 Drill 3 equally spaced holes with a 3mm drill bit through the wall profiles and frame.
6.2 Fix the frame to the wall profiles using the screws ST3.9 × 16 (3 per wall profile).
6.3 Drill 3 equally spaced holes with a 3mm drill bit through the inline post and frame.
6.4 Fix the inline panel with the frame using screw ST3.9 × 16 (No.13 - 3 per wall profile).
Step 6.1
Step 7.1
Step 7.4
Step 7.2
Step 7.5
Step 7.3
Step 7.6
Step 6.3
Step 6.2
Step 7.
7.1 Position the support arm on the inline panel.
7.2 Level the arm using a spirit level. Once you are happy that the support arm is in correct position, mark the wall thought
the screw hole and around the wall fixing. Also, tighten the M8 socket set screw which you can see using the 5/32 allen key.
7.3 Loose the M6 countersunk screw using the 5/32 allen key.
7.4 Remove the arm and the wall fixing, drill the marked points using a 6mm masonry drill bit. once this is done insert 2 x wall
plugs (No.12).
7.5 Fix the wall fixing using 2 x countersunk screw ST4 x 30 (No.14), then put 2 x screw cap on (No.10). Also, tighten the
other M8 socket set screw into the glass clamp.
7.6 Place the arm again and tighten the M6 countersunk screws using the 5/32 allen key.
Note: need to replace
the wall fixing to the
glass clamp when the
inline panel fits with the
side panel as above
shown.
Step 6.4
Side Panel
Glass Clamp
Inline Panel
6
Step 11.
The ball catch can be adjusted in and out using the adjustment
tool to ensure the door panel closes smoothly.
Note: Push the ball catch inside of the hole then turn left or right.
But do not adjust out the ball catch too much.
Step 10.
Fit the handle to the door.
24 HRS
DO NOT USE THE
ENCLOSURE FOR
24 HOURS AFTER
SEALING
Applying Silicone Sealant
Sealing Inside
Seal from the top of the wall profile to the bottom on the INSIDE
between the wall profile and the wall.
IMPORTANT: Do not apply sealant on inside of the tray.
Sealing Outside
Seal from the top of the wall profile to the bottom between the
wall profile and tiles on both sides. Also seal along the bottom
where the frame meets the tray. Seal the joints between the
bottom profile and any upright profiles.
Step 11
Step 10
Step 9.
Fit the upriht profile top cap (No 6) and inline post top cap (No.7 or 8) as shown.
Step 8.
Once you are happy that the installation is correct, push 5 x Profile Clips (No.5) in to the wall profile and evenly space.
Push the Cover Profile (No.3) into the Profile Clips as shown.
Step 9
AFTERCARE
This product has been treated with Clean & Clear™ easy clean glass treatment, a protective barrier which creates
a ‘non-stick’ surface on your glass, helping to resist lime scale build up and water spots. For further information on
Clean & Clear™ please visit www.aprilproducts.co.uk
Aftercare
Clean & Clean™ glass can be cleaned with any suitable nonabrasive glass cleaner - with PH value of between 3-
11; the coating will not be damaged. Avoid surfactants and heavily perfumed products.
Vinegar and water based
products are very effective. Do not use abrasive scrubbing cleaners or equipment for
cleaning.
Warranty
Limited 5 year Warranty for Clean & Clear™ treatment: To guarantee treated surfaces will remain more repellent
than untreated glass for 5 years from start of use, as long as basic manufacturer maintenance recommendations
are followed and no harsh or abrasive cleaners are used.
Cleaning Instructions
It is important to clean your April shower enclosure after every use. Please wipe down all glass and metal parts
with a clean soft cloth. Ensure that all residual water on the glass is removed after every use.
Usage
For reliable, watertight performance from your April enclosure your shower head should not be positioned so that
the shower sprays directly onto the enclosure door. Failure to comply with this may cause the shower to lea
k.
Outward opening doors may cause water to drip onto the floor, please ensure that the floor covering immediately
outside the enclosure will not be affected by water.
.
APRIL PRODUCTS
North Dean Road, West Lane, Keighley, BD22 6QY
Tel: 01535 613 830 Fax: 01535 613 831
www.aprilproducts.co.uk
/