Heat Controller RADS-183G Owner's manual

Category
Mobile air conditioners
Type
Owner's manual

This manual is also suitable for

Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com
OWNERS MANUAL
Room Air Conditioner with R-410A:
RADS-151G
RADS-183G
RADS-253G
Beforeusingyourairconditioner,pleaseread
thismanualcarefullyandkeepitforfuturereference.
WINDOW/WALL TYPE
ROOM AIRCONDITIONER
-
MULTI-STEPSPEEDELECTRONICCONTROL
Sleep
Check
Filter
Follow
Me
Auto
On/off
Fan
High
Med
Low
Energy
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TI MER
TEMP/TI MER
Heat
Owners Manual Room Air Conditioner with R-410A Heat Controller, Inc.
1
CONTENTS
Insideyouwillfindmanyhelpfulhintsonhowtouseandmaintainyourairconditioner
properly.Justalittlepreventivecareonyourpartcansaveyouagreatdealoftime
andmoneyoverthelifeofyourairconditioner. You'llfindmanyanswerstocommon
problemsinthechartoftroubleshootingtips.Ifyoureviewourchartof Troubleshooting
Tipsfirst,youmaynotneedtocallforserviceatall.
Contacttheauthorisedservicetechnicianforrepairormaintenanceofthisunit.
Contacttheinstallerforinstallationofthisunit.
Theairconditionerisnotintendedforusebyyoungchildrenorinfirmpersons
withoutsupervision.
Youngchildrenshouldbesupervisedtoensurethattheydonotplaywiththeair
conditioner.
Ifthepowercordistobereplaced,replacementworkshallbeperformedby
authorisedpersonnelonly.
Installationworkmustbeperformedinaccordancewiththenationalwiring
standardsbyauthorisedpersonnelonly.
!
CAUTION
Read ThisManual
1
1.SAFETY PRECAUTIONS..................................................................2
2.IMPORTANTSAFETY INSTRUCTIONS..........................................4
3.NORMAL SOUNDS...........................................................................5
4. AIRCONDITIONERFEATURES.......................................................5
5.INSTALLATIONINSTRUCTIONS......................................................10
6.CARE ANDCLEANING....................................................................14
7.TROUBLESHOOTINGTIPS...............................................................15
Contact an authorized service technician for repair or maintenance of this unit.
Contact an authorized installer for installation of this unit.
If the power cord needs to be replaced, replacement work shall be performed by
authorized service personnel only.
Installation work must be performed in accordance with the national and local
electric codes and must be performed by authorized personnel only.
17
18
11
Heat Controller, Inc. Room Air Conditioner with R-410A Owners Manual
2
Topreventinjurytotheuserorotherpeopleandpropertydamage,thefollowinginstructions
mustbefollowed.Incorrectoperationduetoignoringofinstructionsmaycauseharmor
damage. Theseriousnessisclassifiedbythefollowingindications.
SafetyPrecautions
Thissymbolindicatesthepossibilityofdeathorseriousinjury.
Meaningsofsymbolsusedinthismanualareasshownbelow.
!
!
WARNING
Alwaysdothis.
Neverdothis.
!
CAUTION
Thissymbolindicatesthepossibilityofinjuryordamagetoproperty.
Pluginpowerplug
properly.
Donotmodifypowercord
lengthorsharetheoutlet
withotherappliances.
Alwaysensureeffective
earthing.
Unplugtheunitifstrange
sounds,smell,orsmoke
comesfromit.
Keepfirearmsaway.
Ventilateroombeforeoperatingair
conditionerifthereisagasleakagefrom
anotherappliance.
Otherwise,itmaycauseelectric
shockorfiredueto heat
generation.
excess
Itmaycauseelectricshockor
fireduetoheatgeneration.
Incorrectearthingmaycause
electricshock.
Itmaycausefireandelectric
shock.
Itmaycausefire.
Itmaycauseexplosion,fireand,burns.
Itmaycauseelectricshockorfire
duetoheatgeneration.
Itmaycauseelectricshock.
Itmaycausefailureofmachine
orelectricshock.
Itmaycausefireandelectric
shock.
Itmaycausefireandelectric
shock.
Itmaycauseelectricshockorfire.
Ifthepowercordisdamaged,it
mustbereplacedbythemanufac-
tureroranauthorisedservice
centreorasimilarlyqualifiedper-
soninordertoavoidahazard.
Thiscoulddamageyourhealth.
Incorrectinstallationmaycause
fireandelectricshock.
Itmaycauseelectricshock.
Itmaycauseanexplosionorfire.
Itmaycausefailureandelectricshock.
Donotoperateorstopthe
unitbyinsertingorpulling
outthepowerplug.
Donotoperatewithwet
handsorindamp
environment.
Donotallowwatertorun
intoelectricparts.
Donotusethesocketifitis
looseordamaged.
Donotusethepowercord
closetoheatingappliances.
Donotdamageorusean
unspecifiedpowercord.
Donotdirectairflowat
roomoccupantsonly.
Alwaysinstallcircuit
breakerandadedicated
powercircuit.
Donotopentheunit
duringoperation.
Donotusethepowercordnear
flammablegasorcombustibles,such
asgasoline,benzene,thinner,etc.
Donotdisassembleormodifyunit.
!
!
!
!
!
!
WARNING
!
2
!
!!
• Otherwise, it may cause electric
shock or re due to excess heat
generation
!
Plug in power cord
plug properly
• It may cause electric shock or
re due to heat generation
!
Do not modify power
cord length or share
the outlet with other
appliances.
Always ensure
effective grounding
!
• Incorrect grounding may cause
electric shock
Unplug the unit if
strange sounds,
odors or smoke
comes from it.
!
It may cause re and electric shock
• It may cause electric shock or
re due to heat generation
Do not operate or stop
the unit by inserting or
pulling out the power
plug
• It may cause electric shock
Do not operate with
wet hands or in a
damp environment
Do not allow water
to run in to electric
parts
• It may cause failure of machine
or electric shock
Do not use the socket if
it is loose or damaged
It may cause re and electric shock
It may cause electric shock or re
If the power cord is damaged, it must be replaced by the manufacturer or an
authorized serivce center or a qualied person in order to avoid a hazard
Do not use a damaged or unspecied power cord
• Incorrect installation may cause
re and electric shock
!
Always install circuit
breaker and a dedicated
power circuit
Do not open the unit
during operation
• It may cause electric shock
Unplug the unit if
strange sounds,
odors or smoke
comes from it.
!
It may cause re and electric shock
Do not use the power
cord close to heating
appliances
It may cause re and electric shock
Do not use the power
cord near ammable gas
or combustiblies, such
as gasoline, benzene,
thinner, etc.
It may cause an explosion orre
It may cause failure and electric shock
To prevent injury to the user and propert damage, the following instructions must be
followed. Incorrect operation due to ignoring instructions may cause harm or damage.
The seriousness is classied by the following indications.
Do not disassemble or modify unit.
Owners Manual Room Air Conditioner with R-410A Heat Controller, Inc.
3
!
CAUTION
Whentheairfilteristobe
removed,donottouchthe
metalpartsoftheunit.
Itmaycauseaninjury.
Donotcleanunitwhen
powerisonasitmaycause
fireandelectricshock,itmay
causeaninjury.
Operationwithwindows
openedmaycausewetting
ofindoorandsoakingof
householdfurniture.
Whentheunitistobe
cleaned,switchoff,andturn
offthecircuitbreaker.
Stopoperationandclose
thewindowinstormor
hurricane.
Usecautionwhenunpackingand
installing.Sharpedgescouldcauseinjury.
Donotcleantheair
conditionerwithwater.
Watermayentertheunitand
degradetheinsulation.Itmay
causeanelectricshock.
Thiscouldinjurethepetor
plant.
Itmaycauseelectricshock
anddamage.
Donotputapetorhouse
plantwhereitwillbe
exposedtodirectairflow.
Holdtheplugbythehead
ofthepowerplugwhen
takingitout.
Ventilatetheroomwellwhen
usedtogetherwithastove,
etc.
Anoxygenshortagemayoccur.
Donotusethisairconditionerto
preserveprecisiondevices,food,
pets,plants,andartobjects.
Itmaycausedeteriorationof
quality,etc.
Itmaycausefailureofproduct
orfire.
Donotuseforspecial
purposes.
Turnoffthemainpower
switchwhennot singthe
unitforalongtime.
u
Ifwaterenterstheunit,turntheunitoffatthepower
outletandswitchoffthecircuitbreaker.Isolate
supplybytakingthepower-plugoutandcontacta
qualifiedservicetechnician.
3
!
!
!
!
!
!
!
Itmaycausefailureof
applianceoraccident.
Appearancemaybe
deterioratedduetochange
ofproductcoloror
scratchingofitssurface.
Donotplaceobstacles
aroundair-inletsorinside
ofair-outlet.
Donotusestrongdeter-
gentsuchaswaxor
thinnerbutuseasoftcloth.
Ifbracketisdamaged,there
isconcernofdamagedueto
fallingofunit.
Thereisdangeroffireor
electricshock.
Ensurethattheinstallationbracketof
theoutdoorapplianceisnotdamaged
duetoprolongedexposure.
Donotplaceheavyobjectonthe
powercordandensurethatthecord
isnotcompressed.
Operationwithoutfiltersmay
causefailure.
Itcontainscontaminantsand
couldmakeyousick.
Alwaysinsertthefilters
securely.Cleanfilteronce
everytwoweeks.
Donotdrinkwaterdrained
fromairconditioner.
!
!
• It may cause an injury due to sharp
edges of components.
When the air lter is to be
removed, do not touch the
metal parts of the unit
• Water may enter the unit and degrade
the insulation. It may cause an
electric shock
Do not allow water to
enter inside the unit
during cleaning
An oxygen shortage may occur
• May cause explosion, re and/or
burns
Ventilate the room well
when used together with
a gas stove or if there is
a gas leak
Do not clean unit when power is on as
it may cause re and electric shock
When the unit is to be
cleaned, switch off, and
turn off the circuit breaker
• Operation with windows opened may
allow rain to enter inside and damage
property
Stop operation and close
the window in storm or
hurricane
• It may cause electric shock and
damage
Hold the plug by the
head of the power plug
when taking it out
• It may cause failure of product or re
Turn off the main power
switch when not using
the unit for a long time
• It may cause failure of appliance or
accident
Do not place obstacles
around air-inlets or inside
of air-outlet
If bracket is damaged, there is concern
of damage due to falling of unit.
Ensure that the instal-
lation bracket of the
outdoor appliance is
not damaged
• Operation without lters may cause
failure
• Operation with dirty/clogged lters
may cause failure
Always insert thelters
securely. Clean lter
once every two weeks
Appearance may be deteriorated
due to change of product color or
scratching of its surface
Do not use strong deter-
gents such as wax or thin-
ner; use a damp, soft cloth
• There is danger of re or electric
shock
Do not place heavy ob-
ject on the power cord
and ensure that the
cord is not compressed
• It contains contaminants and could
make you sick
Do not drink water
drained from air condi-
tioner
• Sharp edges could cause injury
Use caution when un-
packing and installing
If water enters the unit,
turn the unit off at the
power outlet and switch
off the circuit breaker.
Isolate supply by taking
power-plug out and con-
tact a qualied service
technician
!
!
!
!
!
!
!
• Water may enter the unit and degrade
the insulation. It may cause an
electric shock
Heat Controller, Inc. Room Air Conditioner with R-410A Owners Manual
4
IMPORTANTSAFETY INSTRUCTIONS
Besuretheelectricalserviceisadequateforthemodelyouhave
chosen. Thisinformationcanbefoundontheserialplate,which
islocatedonthesideofthecabinetandbehindthegrille.
Besuretheairconditionerisproperlygrounded. Tominimize
shockandfirehazards,propergroundingisimportant. Thepower
cordisequippedwithathree-pronggroundingplugforprotection
againstshockhazards.
Yourairconditionermustbeusedinaproperlygroundedwall
receptacle.Ifthewallreceptacleyouintendtouseisnotadequately
groundedorprotectedbyatimedelayfuseorcircuitbreaker,
haveaqualifiedelectricianinstalltheproperreceptacle.
Ensurethereceptacleisaccessibleaftertheunitinstallation.
Donotrunairconditionerwithoutsideprotectivecoverinplace.
Thiscouldresultinmechanicaldamagewithintheairconditioner.
Donotuseanextensioncordoranadapterplug.
WARNING
Foryoursafety
Donotstoreorusegasolineorotherflammablevaporsandliquidsin
thevicinityofthisoranyotherappliance.
Avoidfirehazardorelectricshock.Donotuseanextensioncordoran
adaptorplug.Donotremoveanyprongfromthepowercord.
WARNING
ElectricalInfor mation
NOTE Forsomemodels,thepower
supplycordwiththisairconditioner
containsacurrentdetectiondevice
designedtoreducetheriskoffire.
PleaserefertothesectionOperation
ofCurrentDevicefordetails.
Intheeventthatthepowersupply
cordisdamaged,itcannotbe
repaired-itmustbereplacedwitha
cordfromtheProductManufacturer.
,
,
Donot,underany
circumstances,cut,
remove,orbypass
thegroundingprong.
Powersupplycord
with3-pronggroundingplug
andcurrentdetectiondevice
Operationof Cur rentDevice
(Applicabletotheunitadoptscurrentdetectiondeviceonly)
Thepowersupplycordcontainsacurrentdevicethatsensesdamagetothepowercord. Totestyourpower
supplycorddothefollowing:
1.Pluginthe AirConditioner.
2. Thepowersupplycordwillhave TWObuttonsontheplughead.Pressthe TEST button,youwillnoticea
clickastheRESET buttonpopsout.
3.PresstheRESET button,againyouwillnoticeaclickasthebuttonengages.
4. Thepowersupplycordisnowsupplyingelectricitytotheunit.(Onsomeproductsthisitalsoindicatedby
alightontheplughead.)
Donotusethisdevicetoturntheunitonoroff.
AlwaysmakesuretheRESET buttonispushedinforcorrectoperation.
Thepowersupplymustbereplacedifitfailsresetwheneitherthe TEST buttonispushed,oritcannotbe
reset. A newonecanbeobtainedfromtheproductmanufacturer.
Ifpowersupplycordisdamaged,itcannotberepaired.ItMUST bereplacedbyone
NOTES:
obtainedfromthe
productmanufacturer.
4
Please refer to the section “Operation
of Current Device” for details.
IMPORTANTSAFETY INSTRUCTIONS
Besuretheelectricalserviceisadequateforthemodelyouhave
chosen. Thisinformationcanbefoundontheserialplate,which
islocatedonthesideofthecabinetandbehindthegrille.
Besuretheairconditionerisproperlygrounded. Tominimize
shockandfirehazards,propergroundingisimportant. Thepower
cordisequippedwithathree-pronggroundingplugforprotection
againstshockhazards.
Yourairconditionermustbeusedinaproperlygroundedwall
receptacle.Ifthewallreceptacleyouintendtouseisnotadequately
groundedorprotectedbyatimedelayfuseorcircuitbreaker,
haveaqualifiedelectricianinstalltheproperreceptacle.
Ensurethereceptacleisaccessibleaftertheunitinstallation.
Donotrunairconditionerwithoutsideprotectivecoverinplace.
Thiscouldresultinmechanicaldamagewithintheairconditioner.
Donotuseanextensioncordoranadapterplug.
WARNING
Foryoursafety
Donotstoreorusegasolineorotherflammablevaporsandliquidsin
thevicinityofthisoranyotherappliance.
Avoidfirehazardorelectricshock.Donotuseanextensioncordoran
adaptorplug.Donotremoveanyprongfromthepowercord.
WARNING
ElectricalInfor mation
NOTE Thepowersupplycordwith
thisairconditionercontainsacurrent
detectiondevicedesignedtoreduce
theriskoffire.
PleaserefertothesectionOperation
ofCurrentDevicefordetails.
Intheeventthatthepowersupply
cordisdamaged,itcannotbe
repaired-itmustbereplacedwitha
cordfromtheProductManufacturer.
,
,
Operationof Cur rentDevice
Thepowersupplycordcontainsacurrentdevicethatsensesdamagetothepowercord. Totestyourpower
supplycorddothefollowing:
1.Pluginthe AirConditioner.
2. Thepowersupplycordwillhave TWObuttonsontheplughead.
Pressthe TEST button,youwillnoticeaclickastheRESET
buttonpopsout.
3.PresstheRESET button,againyouwillnoticeaclickasthebutton
engages.
4. Thepowersupplycordisnowsupplyingelectricitytotheunit.
(Onsomeproductsthisitalsoindicatedbyalightontheplughead.)
Donotusethisdevicetoturntheunitonoroff.
AlwaysmakesuretheRESET buttonispushedinforcorrectoperation.
Thepowersupplymustbereplacedifitfailsresetwheneitherthe TEST buttonispushed,oritcannotbe
reset. A newonecanbeobtainedfromtheproductmanufacturer.
Ifpowersupplycordisdamaged,itcannotberepaired.ItMUST bereplacedbyone
NOTES:
obtainedfromthe
productmanufacturer.
4
TEST
RESET
Plugin&
pressRESET
NOTE:Someplugshave
buttonsonthetop.
Donot,underany
circumstances,cut,
remove,orbypass
thegroundingprong.
Powersupplycord
with3-pronggroundingplug
andcurrentdetectiondevice
Owners Manual Room Air Conditioner with R-410A Heat Controller, Inc.
5
NORMAL SOUNDS
AIRCONDITIONERFEATURES
SoundofRushing Air
Atthefrontoftheunit,youmay
hearthesoundofrushingair
beingmove dbythefan
HighPitchedChatter
Highefficiencycompressors
mayhaveahig hpitchedchatter
duringthecoolingcycle.
Gurgle/Hiss
Gurglingorhissingnoisemay
beheardduetorefrigerant
passingthroughevaporator
duringnor maloperation.
Pingingo rSwitching
Dropletsofwaterhittingconden ser
duringnor maloperationmaycause
pingingorswitchingsounds.
Beforeyoubegin,thoroughlyfamiliarizeyourselfwiththecontrolpanelandremoteasshownbelow
andallitsfunctions,thenfollowthesymbolforthefunctionsyoudesire. Theunitcanbecontrolled
bytheunitcontrolaloneorwiththeremote.
Vibration
Unitmayvibrateandmakenoise
becauseofpoorwallorwindow
constructionorincorrectinstallation.
ELECTRONICCONTROLOPERATINGINSTRUCTIONS
ADJUSTS
TEMPERATURE
ORTIME
ADJUSTS
TEMPERATURE
ORTIME
DISPLAYS
TEMPERATURE
ORTIME
ACTIVATES
TIMER
CHECKFILTER
RESETBUTTON
SETSMODE
ENERGY
SAVERMODE
SLEEP MODE
CLEAN AIRMODE
(onsomemode ls)
SETFANSPEED
TURNSUNIT
ONOROFF
UNITCONTROL
Temp Temp
Timer
Timer
On
Off
S leep
Check
Filter
Timer
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
Fan
M ode
Follow
Me
Energy
Saver
On/Off
5
FOLLOWMEINDICATOR
(onsomemode ls)
Unit may vibrate and make noise
because of poor wall or window
construction or incorrect installation.
Swishing
swishing
NORMAL SOUNDS
AIRCONDITIONERFEATURES
SoundofRushing Air
Atthefrontoftheunit,youmay
hearthesoundofrushingair
beingmove dbythefan
HighPitchedChatter
Highefficiencycompressors
mayhaveahig hpitchedchatter
duringthecoolingcycle.
Gurgle/Hiss
Gurglingorhissingnoisemay
beheardduetorefrigerant
passingthroughevaporator
duringnor maloperation.
Pingingo rSwitching
Dropletsofwaterhittingconden ser
duringnor maloperationmaycause
pingingorswitchingsounds.
Beforeyoubegin,thoroughlyfamiliarizeyourselfwiththecontrolpanelandremoteasshownbelow
a
ndallitsfunctions,thenfollowthesymbolforthefunctionsyoudesire. Theunitcanbecontrolled
bytheunitcontrolaloneorwiththeremote.
Vibration
Unitmayvibrateandmakenoise
becauseofpoorwallorwindow
constructionorincorrectinstallation.
ELECTRONICCONTROLOPERATINGINSTRUCTIONS
UNITCONTROL
5
Sleep
Check
Filter
Follow
Me
Auto
On/Off
Fan
High
Med
Low
Energy
Saver
On
Off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Sleep
Check
Filter
Auto
On/Off
Fan
High
Med
Low
Energy
Saver
On
Off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Heat
(CoolingOnlyModels)
(ElectricHeatingmodels)
Sleep
Check
Filter
Follow
Me
Auto
On/off
Fan
High
Med
Low
Energy
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Heat
Follow
Me
Clean
Air
NORMAL SOUNDS
AIRCONDITIONERFEATURES
SoundofRushing Air
Atthefrontoftheunit,youmay
hearthesoundofrushingair
beingmove dbythefan
HighPitchedChatter
Highefficiencycompressors
mayhaveahig hpitchedchatter
duringthecoolingcycle.
Gurgle/Hiss
Gurglingorhissingnoisemay
beheardduetorefrigerant
passingthroughevaporator
duringnor maloperation.
Pingingo rSwitching
Dropletsofwaterhittingconden ser
duringnor maloperationmaycause
pingingorswitchingsounds.
Beforeyoubegin,thoroughlyfamiliarizeyourselfwiththecontrolpanelandremoteasshownbelow
andallitsfunctions,thenfollowthesymbolforthefunctionsyoudesire. Theunitcanbecontrolled
bytheunitcontrolaloneorwiththeremote.
Vibration
Unitmayvibrateandmakenoise
becauseofpoorwallorwindow
constructionorincorrectinstallation.
ELECTRONICCONTROLOPERATINGINSTRUCTIONS
UNITCONTROL
5
Sleep
Check
Filter
Follow
Me
Auto
On/Off
Fan
High
Med
Low
Energy
Saver
On
Off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Sleep
Check
Filter
Auto
On/Off
Fan
High
Med
Low
Energy
Saver
On
Off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Heat
(CoolingOnlyModels)
(ElectricHeatingmodels)
Sleep
Check
Filter
Follow
Me
Auto
On/off
Fan
High
Med
Low
Energy
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Heat
Follow
Me
Clean
Air
Unit Control
Heat Controller, Inc. Room Air Conditioner with R-410A Owners Manual
6
AIRCONDITIONERFEATURES(CONTINUED)
TOTURNUNITON:
NOTE: ThefollowinginstructionsrepresenttheUnitControls,thesameinstructionscanbeused
fortheRemoteControl.
TOCHANGETEMPERATURE
SETTING:
PresstheOn/Offbutton.
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
Fan
M ode
Follow
Me
Energy
Saver
On/Off
DOTHIS:
Temp Temp
Timer
Timer
On
Off
S leep
Check
Filter
Timer
A uto
A uto
Presstoraise
DOTHIS:
Presstolower
PressorholdeitherLeft(<)orRight(>)button
untilthedesiredtemperatureisseenonthe
display. Thistemperaturewillbeautomatically
maintainedanywherebetween62F(17C)and
86F(30C).Ifyouwantthedisplaytoreadthe
actualroomtemperature,see ToOperateon
FanOnlysection.
NOTE:
TOADJUSTFANSPEEDS:
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
Fan
M ode
Follow
Me
Energy
Saver
On/Off
Presstoselect
appropriatefan
speed
DOTHIS:
UsedtoselecttheFanSpeedinfoursteps-
Auto,Low,MedorHigh.Eachtimethebutton
ispressed,thefanspeedmodeisshifted.
NOTE:
6
Owners Manual Room Air Conditioner with R-410A Heat Controller, Inc.
7
AIRCONDITIONERFEATURES(CONTINUED)
TOSELECTTHE
OPERATINGMODE:
PresstheMode
button.
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
Fan
M ode
Follow
Me
Energy
Saver
On/Off
DOTHIS:
Tochooseoperatingmode,presstheModebutton.
Eachtimeyoupressthebutton,amodeisselected
inasequencethatgoesfrom Auto,Cool,Dryand
Fan. Theindicatorlightbesidewillbeilluminated
andremainedononcethemodeisselected.
NOTE:
Tooperateon Autofeature:
Inthismode,thefanspeedcannotbeadjusted,it
startsautomaticallyataspeedaccordingtothe
roomtemperature.Iftheroomdoesnotgettoo
warm,it willstayatLowspeed.
TooperateonFanOnly:
Usethisfunctiononlywhencoolingisnotdesired,
suchasforroomaircirculationortoexhauststale
air(onsomemodels).(Remembertoopenthevent
duringthisfunction,butkeepitclosedduring
coolingformaximumcoolingefficiency.) Youcan
chooseanyfanspeedyouprefer.
Duringthisfunction,thedisplaywillshowtheactual
roomtemperature,no
tthesettemperatureasinthe
coolingmode.
TOUSETHEENERGY
SAVERFEATURE:
Pressthebutton
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
Fan
M ode
Follow
Me
Energy
Saver
On/Off
DOTHIS:
Inthismode,thefanwillcontinuetorunfor3minutes
afterthecompressorshutsoff. Thefanthencycles
onfor2minutesat10minuteintervalsuntiltheroom
temperatureisabovethesettemperature,atwhich
timethecompressorturnsbackonandCoolingStars.
NOTE:
Temp Temp
Timer
Timer
On
Off
S leep
Check
Filter
Timer
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
SLEEPFEATURE:
PressSleep
button
DOTHIS:
Inthismodetheselectedtemperaturewillincreaseby
4 F(2 or3 C)inthefirsthourafterthemodeisselected.
Thisnewtemperaturewillbemaintainedforanother6
hoursbeforeitreturnstotheoriginallyselected
temperature. ThisendstheSleepmodeandtheunit
willcontinuetooperateasoriginallyprogrammed.
TheSleepmodeprogramcanbecancelledatany
timeduringoperationbyagainpressingtheSleep
button.
O OO
NOTE:
7
TooperateonDrymode:
Inthismode,theairconditionerwillgenerally
operateintheformofadehumidifier.Sincethe
conditionedspaceisaclosedorsealedarea,some
degreeofcoolingwillcontinue.
AIRCONDITIONERFEATURES(CONTINUED)
TOSELECTTHE
OPERATINGMODE:
PresstheMode
button.
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
Fan
M ode
Follow
Me
Energy
Saver
On/Off
DOTHIS:
Tochooseoperatingmode,presstheModebutton.
Eachtimeyoupressthebutton,amodeisselected
inasequencethatgoesfrom Auto,Cool,Dryand
Fan. Theindicatorlightbesidewillbeilluminated
andremainedononcethemodeisselected.
NOTE:
Tooperateon Autofeature:
Inthismode,thefanspeedcannotbeadjusted,it
startsautomaticallyataspeedaccordingtothe
roomtemperature.Iftheroomdoesnotgettoo
warm,it willstayatLowspeed.
TooperateonFanOnly:
Usethisfunctiononlywhencoolingisnotdesired,
suchasforroomaircirculationortoexhauststale
air(onsomemodels).(Remembertoopenthevent
duringthisfunction,butkeepitclosedduring
coolingformaximumcoolingefficiency.) Youcan
chooseanyfanspeedyouprefer.
Duringthisfunction,thedisplaywillshowtheactual
roomtemperature,no
tthesettemperatureasinthe
coolingmode.
TOUSETHEENERGY
SAVERFEATURE:
Pressthebutton
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
Fan
M ode
Follow
Me
Energy
Saver
On/Off
DOTHIS:
Inthismode,thefanwillcontinuetorunfor3minutes
afterthecompressorshutsoff. Thefanthencycles
onfor2minutesat10minuteintervalsuntiltheroom
temperatureisabovethesettemperature,atwhich
timethecompressorturnsbackonandCoolingStars.
NOTE:
Temp Temp
Timer
Timer
On
Off
S leep
Check
Filter
Timer
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
SLEEPFEATURE:
PressSleep
button
DOTHIS:
Inthismodetheselectedtemperaturewillincreaseby
4 F(2 or3 C)inthefirsthourafterthemodeisselected.
Thisnewtemperaturewillbemaintainedforanother6
hoursbeforeitreturnstotheoriginallyselected
temperature. ThisendstheSleepmodeandtheunit
willcontinuetooperateasoriginallyprogrammed.
TheSleepmodeprogramcanbecancelledatany
timeduringoperationbyagainpressingtheSleep
button.
O OO
NOTE:
7
TooperateonDrymode:
Inthismode,theairconditionerwillgenerally
operateintheformofadehumidifier.Sinc
ethe
conditionedspaceisaclosedorsealedarea,some
degreeofcoolingwillcontinue.
In the mode, the air conditioner will generally operate in
the form of a dehumidier to remove moisture from the air.
Since the conditioned space is a closed or sealed area,
some degree of cooling will continue.
starts.
each mode will be illuminated
AIRCONDITIONERFEATURES(CONTINUED)
TOSELECTTHE
OPERATINGMODE:
PresstheMode
button.
DOTHIS:
Tochooseoperatingmode,presstheModebutton.
Eachtimeyoupressthebutton,amodeisselected
inasequencethatgoesfrom Auto,Cool,Dry,Heat
(Coolingonlymodelswithout)andFan. Theindicator
lightbesidewillbeilluminatedandremainedon
oncethemodeisselected.
NOTE:
Tooperateon Autofeature:
Inthismode,thefanspeedcannotbeadjusted,it
startsautomaticallyataspeedaccordingtothe
roomtemperature.Iftheroomdoesnotgettoo
warm,it willstayatLowspeed.
TooperateonFanOnly:
Usethisfunctiononlywhencoolingisnotdesired,
suchasforroomaircirculationortoexhauststale
air(onsomemodels).(Remembertoopenthevent
duringthisfunction,butkeepitclosedduring
coolingformaximumcoolingefficiency.) Youcan
chooseanyfanspeedyouprefer.
Duringthisfunction,thedisplaywillshowtheactual
roomtemperature,no
tthesettemperatureasinthe
coolingmode.
TOUSETHEENERGY
SAVERFEATURE:
Pressthebutton
DOTHIS:
Inthismode,thefanwillcontinuetorunfor3minutes
afterthecompressorshutsoff. Thefanthencycles
onfor2minutesat10minuteintervalsuntiltheroom
temperatureisabovethesettemperature,atwhich
timethecompressorturnsbackonandcoolingstars.
NOTE:
SLEEPFEATURE:
PressSleep
button
DOTHIS:
Inthismodetheselectedtemperaturewillincreaseby
2degreesF30minutesafterthemodeisselected.
Thetemperaturewillthenincreasebyanother2
degreesFafteranadditional30minutes. Thisnew
temperaturewillbemaintainedfor7hoursbeforeit
returnstotheoriginallyselectedtemperature. This
endstheSleepmodeandtheunitwillcontinueto
operateasoriginallyprogrammed. TheSleepmode
programcanbecancelledatanytimeduringoperation
byagainpressingtheSleepbutton.
NOTE:
7
Energy
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Heat
Energy
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Sleep
Check
Filter
Follow
Me
Auto
On/off
Fan
High
Med
Low
on
off
Timer
TEMP/TIMER
TEMP/TIMER
Clean
Air
Clean
Air
TooperateonDrymode:
Inthismode,theairconditionerwillgenerally
operateintheformofadehumidifier.Sincethe
conditionedspaceisaclosedorsealedarea,some
degreeofcoolingwillcontinue.
AIRCONDITIONERFEATURES(CONTINUED)
TOSELECTTHE
OPERATINGMODE:
PresstheMode
button.
DOTHIS:
Tochooseoperatingmode,presstheModebutton.
Eachtimeyoupressthebutton,amodeisselected
inasequencethatgoesfrom Auto,Cool,Dry,Heat
(Coolingonlymodelswithout)andFan. Theindicator
lightbesidewillbeilluminatedandremainedon
oncethemodeisselected.
NOTE:
Tooperateon Autofeature:
Inthismode,thefanspeedcannotbeadjusted,it
startsautomaticallyataspeedaccordingtothe
roomtemperature.Iftheroomdoesnotgettoo
warm,it willstayatLowspeed.
TooperateonFanOnly:
Usethisfunctiononlywhencoolingisnotdesired,
suchasforroomaircirculationortoexhauststale
air(onsomemodels).(Remembertoopenthevent
duringthisfunction,butkeepitclosedduring
coolingformaximumcoolingefficiency.) Youcan
chooseanyfanspeedyouprefer.
Duringthisfunction,thedisplaywillshowtheactual
roomtemperature,no
tthesettemperatureasinthe
coolingmode.
TOUSETHEENERGY
SAVERFEATURE:
Pressthebutton
DOTHIS:
Inthismode,thefanwillcontinuetorunfor3minutes
afterthecompressorshutsoff. Thefanthencycles
onfor2minutesat10minuteintervalsuntiltheroom
temperatureisabovethesettemperature,atwhich
timethecompressorturnsbackonandcoolingstars.
NOTE:
SLEEPFEATURE:
PressSleep
button
DOTHIS:
Inthismodetheselectedtemperaturewillincreaseby
2degreesF30minutesafterthemodeisselected.
Thetemperaturewillthenincreasebyanother2
degreesFafteranadditional30minutes. Thisnew
temperaturewillbemaintainedfor7hoursbeforeit
returnstotheoriginallyselectedtemperature. This
endstheSleepmodeandtheunitwillcontinueto
operateasoriginallyprogrammed. TheSleepmode
programcanbecancelledatanytimeduringoperation
byagainpressingtheSleepbutton.
NOTE:
7
Energy
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Heat
Energy
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Sleep
Check
Filter
Follow
Me
Auto
On/off
Fan
High
Med
Low
on
off
Timer
TEMP/TIMER
TEMP/TIMER
Clean
Air
Clean
Air
TooperateonDrymode:
Inthismode,theairconditionerwillgenerally
operateintheformofadehumidifier.Sincethe
conditionedspaceisaclosedorsealedarea,some
degreeofcoolingwillcontinue.
Heat Controller, Inc. Room Air Conditioner with R-410A Owners Manual
8
Temp Temp
Timer
Timer
On
Off
S leep
Check
Filter
Timer
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
TIMER:AUTOSTART/
STOPFEATURE:
Press Timer
button
DOTHIS:
AIRCONDITIONERFEATURES(CONTINUED)
Firstpressthe Timerbutton,theindicatorlight
besideswordOnilluminates.Itindicatesthe Auto
Startprogramisinitiated.
PressorholdtheLeftarroworRightarrowtochange
the Autotimeby0.5hourincrements,upto10hours,
thenat1hourincrementsupto24hours. Thecontrol
willcountdownthetimeremaininguntilstart.
Theselectedtimewillregisterin5secondandthe
systemwillautomaticallyrevertbacktodisplaythe
previoustemperaturesetting.
TurningtheunitONorOFFatanytimewillcancelthe
AutoStart/Stopfunction.
NOTE:
Temp Temp
Timer
Timer
On
Off
S leep
Check
Filter
Timer
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
CHECKFILTERFEATURE:
PressCheck
Filterbutton
DOTHIS:
Temp Temp
Timer
Timer
On
Off
S leep
Check
Filter
Timer
A uto
C ool
D ry
Fan
M ed
H igh
Clean
Air
CLEANAIRFEATURE:
(onsomemodels)
PressClean
Airbutton
DOTHIS:
Thisfeatureisaremindertocleanthe AirFilterfor
moreefficientoperation. TheLED(light)willillumi-
nateafter250hoursofoperation. Toresetafter
cleaningthefilter,presstheCheckFilterbuttonand
thelightwillgooff.
NOTE:
PresstheClean Airbutton,theiongeneratorisener-
gizedandwillhelptoremovepollenandimpurities
fromtheair,andtraptheminthefilter.
NOTE:
8
AIR CONDITIONER FEATURES (CONTINUED)
Press the Timer button, the indicator light
the time by 0.5 hour increments, up to 10 hours
AIRCONDITIONERFEATURES(CONTINUED)
TOSELECTTHE
OPERATINGMODE:
PresstheMode
button.
DOTHIS:
Tochooseoperatingmode,presstheModebutton.
Eachtimeyoupressthebutton,amodeisselected
inasequencethatgoesfrom Auto,Cool,Dry,Heat
(Coolingonlymodelswithout)andFan. Theindicator
lightbesidewillbeilluminatedandremainedon
oncethemodeisselected.
NOTE:
Tooperateon Autofeature:
Inthismode,thefanspeedcannotbeadjusted,it
startsautomaticallyataspeedaccordingtothe
roomtemperature.Iftheroomdoesnotgettoo
warm,it willstayatLowspeed.
TooperateonFanOnly:
Usethisfunctiononlywhencoolingisnotdesired,
suchasforroomaircirculationortoexhauststale
air(onsomemodels).(Remembertoopenthevent
duringthisfunction,butkeepitclosedduring
coolingformaximumcoolingefficiency.) Youcan
chooseanyfanspeedyouprefer.
Duringthisfunction,thedisplaywillshowtheactual
roomtemperature,no
tthesettemperatureasinthe
coolingmode.
TOUSETHEENERGY
SAVERFEATURE:
Pressthebutton
DOTHIS:
Inthismode,thefanwillcontinuetorunfor3minutes
afterthecompressorshutsoff. Thefanthencycles
onfor2minutesat10minuteintervalsuntiltheroom
temperatureisabovethesettemperature,atwhich
timethecompressorturnsbackonandcoolingstars.
NOTE:
SLEEPFEATURE:
PressSleep
button
DOTHIS:
Inthismodetheselectedtemperaturewillincreaseby
2degreesF30minutesafterthemodeisselected.
Thetemperaturewillthenincreasebyanother2
degreesFafteranadditional30minutes. Thisnew
temperaturewillbemaintainedfor7hoursbeforeit
returnstotheoriginallyselectedtemperature. This
endstheSleepmodeandtheunitwillcontinueto
operateasoriginallyprogrammed. TheSleepmode
programcanbecancelledatanytimeduringoperation
byagainpressingtheSleepbutton.
NOTE:
7
Energy
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Heat
Energy
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Sleep
Check
Filter
Follow
Me
Auto
On/off
Fan
High
Med
Low
on
off
Timer
TEMP/TIMER
TEMP/TIMER
Clean
Air
Clean
Air
TooperateonDrymode:
Inthismode,theairconditionerwillgenerally
operateintheformofadehumidifier.Sincethe
conditionedspaceisaclosedorsealedarea,some
degreeofcoolingwillcontinue.
TIMER:AUTOSTART/
STOPFEATURE:
Press Timer
button
DOTHIS:
AIRCONDITIONERFEATURES(CONTINUED)
Firstpressthe Timerbutton,theindicatorlight
besideswordOnilluminates.Itindicatesthe Auto
Startprogramisinitiated.
PressorholdtheUp()orDown()tochange
the Autotimeby0.5hourincrements,upto10hours,
thenat1hourincrementsupto24hours. Thecontrol
willcountdownthetimeremaininguntilstart.
Theselectedtimewillregisterin5secondandthe
systemwillautomaticallyrevertbacktodisplaythe
previoustemperaturesetting.
TurningtheunitONorOFFatanytimewillcancel
the AutoStart/Stopfunction.
NOTE:
CHECKFILTERFEATURE:
PressCheck
Filterbutton
DOTHIS:
Thisfeatureisaremindertocleanthe AirFilterfor
moreefficientoperation. TheLED(light)willillumi-
nateafter250hoursofoperation. Toresetafter
cleaningthefilter,presstheCheckFilterbuttonand
thelightwillgooff.
NOTE:
8
Energy
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Sleep
Check
Filte r
Follo w
Me
Auto
On/of f
Fan
High
Med
Low
on
off
Timer
TEMP/TIMER
TEMP/TIMER
FOLLOWMEFEATURE:
(onsomemodels)
Lightflashing
NOTE:
ToactivatetheFollowMefeature,pointtheremote
controltowardstheunitandpresstheFollowMe
button. T
Iftheunit
doesnotreceivetheFollowMe signalduringany7
minuteinterval,theunitwillbeeptoindicatethe
FollowMemodehasended.
Theactualtemperaturecanbedisplayedattheunit
by pressingtheFanOnlymode.WhenintheCool
mode,theunitdisplayindicatesthesettemperature.
heremotedisplayisactualtemperature
atitslocation. Theremotecontrolwillsendthis
signaltotheairconditionerevery3minutesinterval
untilpresstheFollowMebuttona
gain.
Thisfeaturecanbeactivatedfromtheremote
controlONLY.Theremotecontrolservesasa
remotethermostatallowingfortheprecise
temperaturecontrolatitslocation.
Sleep
Check
Filter
Follow
Me
Auto
On/off
Fan
High
Med
Low
on
off
Timer
TEMP/TIMER
TEMP/TIMER
Clean
Air
Owners Manual Room Air Conditioner with R-410A Heat Controller, Inc.
9
AIR CONDITIONER FEATURES (CONTINUED)
AIRCONDITIONERFEATURES(CONTINUED)
FOLLOWMEFEATURE:
(onsomemodels)
Lightflashing
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
Fan
M ode
Follow
Me
Energy
Saver
On/Off
NOTE:
ToactivatetheFollowMefeature,pointtheremote
controltowardstheunitandpresstheFollowMe
button. T
Iftheunit
doesnotreceivetheFollowMe signalduringany7
minuteinterval,theunitwillbeeptoindicatethe
FollowMemodehasended.
Theactualtemperaturecanbedisplayedattheunit
by pressingtheFanOnlymode.WhenintheCool
mode,theunitdisplayindicatesthesettemperature.
heremotedisplayisactualtemperature
atitslocation. Theremotecontrolwillsendthis
signaltotheairconditionerevery3minutesinterval
untilpresstheFollowMebuttona
gain.
Thisfeaturecanbeactivatedfromtheremote
controlONLY.Theremotecontrolservesasa
remotethermostatallowingfortheprecise
temperaturecontrolatitslocation.
ADDITIONALTHINGSYOUSHOULDKNOW
Nowthatyouhavemasteredtheoperatingprocedure,herearemorefeaturesinyourcontrolthat
youshouldbecomefamiliarwith.
TheCoolcircuithasanautomatic3minutetimedelayedstartiftheunitisturnedoffandon
quickly. Thispreventsoverheatingofthecompressorandpossiblecircuitbreakertripping.
Thefanwillcontinuetorunduringthistime.
Thecontrolwillmaintainanysettemperaturewithin2 F/ ,between62 and86 .
ThecontroliscapableofdisplayingtemperatureindegreesFahrenheitordegreesCelsius.
Toconvertfr
omonetotheother,pressandholdtheLeftandRight Temp/Timerbuttonsatthe
sametime,for3seconds.
O O O O O O
1 C F/17 C F/30 C
FreshAirVentControl(onsomemodels):
Figure1(VENT CLOSED)
Figure2(VENT OPEN)
TheFresh AirVentallowstheairconditionerto:
1.Recirculateinsideair-VentClosed(SeeFig.1)
2.Drawfreshairintotheroom-VentOpen(seeFig.2)
3.Exchangeairfromtheroomanddrawsfreshairinto
theroom-VentandExhaustOpen(seeFig.3)
Figure3(VENT &EXHAUST OPEN)
9
displays actual temperature
signal to the air conditioner in 3 minutes intervals
until the Follow Me button is pressed again. If the unit
TIMER:AUTOSTART/
STOPFEATURE:
Press Timer
button
DOTHIS:
AIRCONDITIONERFEATURES(CONTINUED)
Firstpressthe Timerbutton,theindicatorlight
besideswordOnilluminates.Itindicatesthe Auto
Startprogramisinitiated.
PressorholdtheUp()orDown()tochange
the Autotimeby0.5hourincrements,upto10hours,
thenat1hourincrementsupto24hours. Thecontrol
willcountdownthetimeremaininguntilstart.
Theselectedtimewillregisterin5secondandthe
systemwillautomaticallyrevertbacktodisplaythe
previoustemperaturesetting.
TurningtheunitONorOFFatanytimewillcancel
the AutoStart/Stopfunction.
NOTE:
CHECKFILTERFEATURE:
PressCheck
Filterbutton
DOTHIS:
Thisfeatureisaremindertocleanthe AirFilterfor
moreefficientoperation. TheLED(light)willillumi-
nateafter250hoursofoperation. Toresetafter
cleaningthefilter,presstheCheckFilterbuttonand
thelightwillgooff.
NOTE:
8
Energy
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TIMER
TEMP/TIMER
Sleep
Check
Filte r
Follo w
Me
Auto
On/of f
Fan
High
Med
Low
on
off
Timer
TEMP/TIMER
TEMP/TIMER
FOLLOWMEFEATURE:
(onsomemodels)
Lightflashing
NOTE:
ToactivatetheFollowMefeature,pointtheremote
controltowardstheunitandpresstheFollowMe
button. T
Iftheunit
doesnotreceivetheFollowMe signalduringany7
minuteinterval,theunitwillbeeptoindicatethe
FollowMemodehasended.
Theactualtemperaturecanbedisplayedattheunit
by pressingtheFanOnlymode.WhenintheCool
mode,theunitdisplayindicatesthesettemperature.
heremotedisplayisactualtemperature
atitslocation. Theremotecontrolwillsendthis
signaltotheairconditionerevery3minutesinterval
untilpresstheFollowMebuttona
gain.
Thisfeaturecanbeactivatedfromtheremote
controlONLY.Theremotecontrolservesasa
remotethermostatallowingfortheprecise
temperaturecontrolatitslocation.
Sleep
Check
Filter
Follow
Me
Auto
On/off
Fan
High
Med
Low
on
off
Timer
TEMP/TIMER
TEMP/TIMER
Clean
Air
ADDITIONALTHINGSYOUSHOULDKNOW
Nowthatyouhavemasteredtheoperatingprocedure,herearemorefeaturesinyourcontrolthat
youshouldbecomefamiliarwith.
TheCoolcircuithasanautomatic3minutetimedelayedstartiftheunitisturnedoffandon
quickly. Thispreventsoverheatingofthecompressorandpossiblecircuitbreakertripping.
Thefanwillcontinuetorunduringthistime.
Thecontrolwillmaintainanysettemperaturewithin2F,between60Fand90Fdegrees.
The controliscapableofdisplayingtemperatureindegreesFahrenheitordegreesCelsius.
Toconv
ertfromonetotheother,pressandholdtheUpandDown Temp/Timerbuttonsatthe
sametime,for3seconds.
FreshAirVentControl(onsomemodels):
Figure1(VENT CLOSED)
Figure2(VENT OPEN)
TheFresh AirVentallowstheairconditionerto:
1.Recirculateinsideair-VentClosed(SeeFig.1)
2.Drawfreshairintotheroom-VentOpen(seeFig.2)
3.Exchangeairfromtheroomanddrawsfreshairinto
theroom-VentandExhaustOpen(seeFig.3)
Figure3
(VENT &EXHAUST OPEN)
9
AirDirectionalLouvers
The4-wayairdirectionallouversallowyouto
directtheairflowUporDownandLeftorRight
throughouttheroomasneeded. Toadjustthe
airdirectionallouversside-to-side,usethe
centerhandlesasyoumoveitside-to-side.
AirDirection(4-way)
TOUSETHECLEANAIRFEATURE:
(onsomemodels)
Pressthe
button
DOTHIS:
Energ y
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TI MER
TEMP/TI MER
Clean
Air
PresstheClean Airbutton,theiongeneratoris
energizedandwillhelptoremovepollenand
impuritiesfromtheair,andtraptheminthefilter.
NOTE:
energized
Heat Controller, Inc. Room Air Conditioner with R-410A Owners Manual
10
AIRCONDITIONERFEATURES(CONTINUED)
FOLLOWMEFEATURE:
(onsomemodels)
Lightflashing
A uto
C ool
D ry
Fan
Low
A uto
M ed
H igh
Clean
Air
Fan
M ode
Follow
Me
Energy
Saver
On/Off
NOTE:
ToactivatetheFollowMefeature,pointtheremote
controltowardstheunitandpresstheFollowMe
button. T
Iftheunit
doesnotreceivetheFollowMe signalduringany7
minuteinterval,theunitwillbeeptoindicatethe
FollowMemodehasended.
Theactualtemperaturecanbedisplayedattheunit
by pressingtheFanOnlymode.WhenintheCool
mode,theunitdisplayindicatesthesettemperature.
heremotedisplayisactualtemperature
atitslocation. Theremotecontrolwillsendthis
signaltotheairconditionerevery3minutesinterval
untilpresstheFollowMebuttona
gain.
Thisfeaturecanbeactivatedfromtheremote
controlONLY.Theremotecontrolservesasa
remotethermostatallowingfortheprecise
temperaturecontrolatitslocation.
ADDITIONALTHINGSYOUSHOULDKNOW
Nowthatyouhavemasteredtheoperatingprocedure,herearemorefeaturesinyourcontrolthat
youshouldbecomefamiliarwith.
TheCoolcircuithasanautomatic3minutetimedelayedstartiftheunitisturnedoffandon
quickly. Thispreventsoverheatingofthecompressorandpossiblecircuitbreakertripping.
Thefanwillcontinuetorunduringthistime.
Thecontrolwillmaintainanysettemperaturewithin2 F/ ,between62 and86 .
ThecontroliscapableofdisplayingtemperatureindegreesFahrenheitordegreesCelsius.
Toconvertfr
omonetotheother,pressandholdtheLeftandRight Temp/Timerbuttonsatthe
sametime,for3seconds.
O O O O O O
1 C F/17 C F/30 C
FreshAirVentControl(onsomemodels):
Figure1(VENT CLOSED)
Figure2(VENT OPEN)
TheFresh AirVentallowstheairconditionerto:
1.Recirculateinsideair-VentClosed(SeeFig.1)
2.Drawfreshairintotheroom-VentOpen(seeFig.2)
3.Exchangeairfromtheroomanddrawsfreshairinto
theroom-VentandExhaustOpen(seeFig.3)
Figure3(VENT &EXHAUST OPEN)
9
AIR CONDITIONER FEATURES (CONTINUED)
that
again
2°F (1°C), between 60°F (16°C) and 90°F (32°C)
ADDITIONALTHINGSYOUSHOULDKNOW
Nowthatyouhavemasteredtheoperatingprocedure,herearemorefeaturesinyourcontrolthat
youshouldbecomefamiliarwith.
TheCoolcircuithasanautomatic3minutetimedelayedstartiftheunitisturnedoffandon
quickly. Thispreventsoverheatingofthecompressorandpossiblecircuitbreakertripping.
Thefanwillcontinuetorunduringthistime.
Thecontrolwillmaintainanysettemperaturewithin2F,between60Fand90Fdegrees.
The controliscapableofdisplayingtemperatureindegreesFahrenheitordegreesCelsius.
Toconv
ertfromonetotheother,pressandholdtheUpandDown Temp/Timerbuttonsatthe
sametime,for3seconds.
FreshAirVentControl(onsomemodels):
Figure1(VENT CLOSED)
Figure2(VENT OPEN)
TheFresh AirVentallowstheairconditionerto:
1.Recirculateinsideair-VentClosed(SeeFig.1)
2.Drawfreshairintotheroom-VentOpen(seeFig.2)
3.Exchangeairfromtheroomanddrawsfreshairinto
theroom-VentandExhaustOpen(seeFig.3)
Figure3
(VENT &EXHAUST OPEN)
9
AirDirectionalLouvers
The4-wayairdirectionallouversallowyouto
directtheairflowUporDownandLeftorRight
throughouttheroomasneeded. Toadjustthe
airdirectionallouversside-to-side,usethe
centerhandlesasyoumoveitside-to-side.
AirDirection(4-way)
TOUSETHECLEANAIRFEATURE:
(onsomemodels)
Pressthe
button
DOTHIS:
Energ y
Saver
on
off
Timer
Auto
Fan
Cool
Dry
Mode
TEMP/TI MER
TEMP/TI MER
Clean
Air
PresstheClean Airbutton,theiongeneratoris
energizedandwillhelptoremovepollenand
impuritiesfromtheair,andtraptheminthefilter.
NOTE:
air directional louvers side-to-side or up and
down, move the lever until the desired air ow
direction is obtained.
Owners Manual Room Air Conditioner with R-410A Heat Controller, Inc.
11
INSTALLATIONINSTRUCTIONS
10
Pleaseread ALL instructionsbeforeinstalling. Twopeoplearerecommendtoinstallthisproduct.
Ifanewelectricaloutletisrequired,havetheoutletinstalledbyaqualifiedelectricianbefore
installingunit.
Preliminar yInstructions
Dothefollowingbeforestartingtoinstallunit.
Seeillustrationsbelow.
Checkdimensionsofyourunittodetermine
modeltype:
UnitHeight:
UnitWidth:
Min.WindowOpening:
Min.WindowWidth:
Max.WindowWidth:
185/8175/8
2623
1
2
/
1
2
/
1918
1
2
/
3126
1
2
/
4340
1
2
/
1. --themounting
partsfurnishedwiththisairconditionerare
madetoinstallinawoodensilldouble-hung
window. Thestandardpartsareforwindow
dimensionslistedabove.Opensashtoamini-
mumof19inches(483mm).SeeFig.1.
Checkwindowopeningsize
2. --allwoodpartsof
windowmustbeingoodshapeandabletofirmly
holdtheneededscrews.Ifnot,makerepairs
beforeinstallingunit.
Checkconditionofwindow
3. --ifyourstorm
windowframedoesnotallowtheclearance
required,correctbyaddingapieceofwoodas
showninFIG.2,orbyremovingstormwindow
whilerooma
irconditionerisbeinginstalled.
Checkyourstormwindows
4. --
checkareaoutsideofwindowforthingssuchas
shrubs,trees,orawnings.Inside,besure
furniture,drapes,orblindswillnotstopproper
airflow.
Checkforanythingthatcouldblockairflow
5. Power
supplymustbethesameasthatshownonthe
unitserialnameplate.Powercordis48inches
long.Besureyouhaveanoutletnear.
6. Removeall
packingmaterial.Protectfloororcarpetfrom
damage. Twopeopleshouldbeusedtomove
andinstallunit.
Checktheavailableelectricalservice-
Carefullyunpac
kairconditioner-
SASH
/2MIN.
1
19MIN.
StormWindowFrameor
OtherObstruction
StormWindow
FrameorOther
Obstruction
Board
Thickness
AsRequired,
AlongEntire
Stool.Fasten
With TwoNails
OrScrews.
Fig.1
Fig.2
/2MIN.
1
/2MIN.
1
19MIN.
SASH
WindowSashSeal
SafetyLockand
3/4LongHex
HeadScrew
Top Angle
FoamGasket
WasherHead
Lockingscrew
Frame
Assembly
(Left)
SideRetainer
Seal-bottom
RailtoUnit
1 /2 Long
Screw and
Locknuts
Locknut
3 /4 Long
Flat Head
Bolt
Sill Angle
Bracket
WindowSupport
Bracket
Frame
Assembly
(Right)
on
,
Please read ALL instructions before installing. Two people are recommended to install this
product. If a new electrical outlet is required, have the outlet installed by a qualied electrician
before installing unit.
Heat Controller, Inc. Room Air Conditioner with R-410A Owners Manual
12
ToolsRequired
A largeflatbladescrewdriver
Tapemeasure
Adjustablewrenchorpliers
Pencil
Level
Socketwrenches
PhillipsScrewdriver
11
7/16inchLocking
screwandFlat
washerforwindow
panels
3/4inchLong
Hex-headScrew
SafetyLock
1/2inchLong
screwandLocknut
3/4inchLong
FlatHeadBolt
andLocknut
Sill Angle
Bracket
Longhex-head
lockingscrew
fortopangle,
sideretainer
5/16inchLong
2ea.
4
1
4ea.
2ea.
2
10
Hardware
(Packedwiththeunit)
Owners Manual Room Air Conditioner with R-410A Heat Controller, Inc.
13
12
WindowMounting
1
RemoveChassis
1.Pulldownfrontpanelandremovefilter.
(SeeFig.1).
2.Liftfrontupwardsandplacetooneside.
3.Locatethefourfrontscrewsandremove.
Thesescrewswillbeneededtore-install
thefrontlater.(SeeFig.2).
6.Removeshippingscrewsfromtopofunitand
alsoonthesidebythebaseifinstalled.
7.Holdthecabinetwhilepullingonthebase
handle,andcarefully removetheunit.
8. Addtwofoaminsertstoholesintopofcabinet
whereshippingscrewswereremovedfrom.
9. Yourunitmaycomewithinternalpackaging.
Thispackagingmustberemovedpriorto
instal
lingtheairconditionerbackintothe
cabinet.(seeFig.5).
4.Pryawayfrontfromcabinetsidesasshownin
Fig.3.
5.Gentlyliftfrontoffunitandplacetooneside
(seeFig.4).
2
InstallTopAngleand
SideBracket
1. Attachfoamgaskettotopangle
aboveholesasshowninFig.6.
2.Installtopangleandsideretainers
tocabinetasshowninFig.6.
3
AssembleWindowFillerPanels
1.Placecabinetonfloor,abench,or
atable.
2.Slide sectionofwindowfillerpanel
intosideretaineronthesideofthe
cabinet(seeFig.7).Dobothsides.
I
,,
,,
Plastic
Frame
WindowFiller
Panel
SideRetainer
Fig.7
Fig.6
5 16 long
hex-head
/
1. Pull down front grille and remove lter
(see Fig. 1).
2. Lift front grille upwards to remove.
3. Locate the four front screws and remove.
These screws will be needed to reinstall the
front grille later. (See Fig. 2).
4. Pry away front panel from cabinet sides as
shown in Fig. 3.
5. Gently lift front panel off unit to remove (see
Fig. 4).
6. Remove shipping screws from top of unit and
also on the side by the base (if installed).
9. Your unit may come with internal packaging.
This packaging must be removed prior to re-
installing the air conditioner into the cabinet
(see Fig. 5).
2. Install top angle and side retainers
onto cabinet as shown in Fig. 6.
Heat Controller, Inc. Room Air Conditioner with R-410A Owners Manual
14
3.Inserttopandbottomlegsofwindow
fillerpanelframeintochannelinthe
topangleandbottomrail.Doboth
sides.
4.Insertwasherheadlockingscrews
(2)intoholesintoplegoffillerpanel
frame(seestep6).Donottotallytigh-
ten. Allowlegtoslidefreely.Screws
willbetightenedaftersection6.
4
InstallTopAngleand
SideBracket
3.Shiftcabinetleftorrightasneededtolineup
centerofcabinetoncenterlinemarkedonstool.
4.Fastencabinettowindowstoolwith2screws
intoholes(Youmaywishtopre-drillpilotholes).
5. Addbottomrailsealoverscrewstowindowstool.
1.Openwindowandmarkcenterofwindowstool.
2.Placecabinetinwindowwithbottomstoolangle
firmlyseatedoverwindowstoolasshown.Bring
windowdowntemporarilybehindtopangleto
holdcabinetinplace.
Stool
Stool
Angle
13
5
InstallSupportBracket
1.Holdeachsupportbracketflushagainst
outsideofsill,andtighttobottomofcabinet
asshownbelow.Markbracketsattoplevel
ofsill,andremove.
2. Assemblesillanglebrackettosupport
bracketsatthemarkedposition,asshown.
Handtighten,butallowforanychangeslater.
Top
View
AirCondi tioner
Cabinet
Plastic
Frame
ISection
Window
Filler
Panel
Locking
Screw
Hole
Bottom
RailSeal
34Long
Hex-headScrew
Mark
12LongScrews
AndLocknuts
Left
Right
Sill Angle
Bracket
FlatHead
Bolt
2EachRequiredFor
EachSupportBracket
Locknut
1. Open window and mark center of window sill.
2. Place cabinet in window with bottom sill angle rmly
seated over window sill as shown. Bring window
down temporarily behind top angle to hold cabinet
in place.
Sill
Sill
3. Shift cabinet left or right as needed to line up center
of cabinet on center line marked on sill.
4. Fasten cabinet to window sill with 2 screws into holes
(pre-drill pilot holes if needed).
5. Add bottom rail seal over screws to window sill
Owners Manual Room Air Conditioner with R-410A Heat Controller, Inc.
15
14
3.Closewindowbehindtopangle.
6
ExtendWindowFillerPanels
1.Carefullyraisewindowtoexposefillerpanel
lockingscrews.Loosenscrewssofillerpanels
slideeasily.
2.Extendpanelstofillwindowopeningcompletely.
Tightenlockingscrewsontop.
3.Installsupportbrackets(withsillangle
bracketsattached)tocorrectholein
bottomofcabinetasshown.
4. T ightenall6boltssecurely.
12LongScre ws
andLockn uts
Lockin g Screw
7
InstallWindowLockand
SashSeal
1. T rimsashsealtofitwindowwidth.Insertinto
spacebetweenupperandlowersashes.
2. Attachrightanglesafetylockasshown.
WindowSashSeal
SafetyLock
34Long
Hex-hea d
Screws
8
InstallChassisintoCabinet
andInstallFronttoUnit
1.Liftairconditionerandcarefullyslideinto
cabinetleaving6inchesprotruding.
2.DONOT pushoncontrolsorfinnedcoils.
3.Besurechassis isfirmlyseatedtowardsrear
ofcabinet.
4.Installationoffrontisthereverseofremoval
outlinedinSection1.
4. Installation of front panel and grille is the reverse
of removal outlined in Section 1.
Heat Controller, Inc. Room Air Conditioner with R-410A Owners Manual
16
CARE ANDCLEANING
Cleanyourairconditioneroccasionallytokeepitlookingnew. Besuretounplugtheunit
beforecleaningtopreventchockorfirehazards.
CAUTION
AirFilterCleaning
Theairfiltershouldbecheckedatleastoncea
monthtoseeifcleaningisnecessary. Trapped
particlesinthefiltercanbuildupandcausean
accumulationoffrostonthecoolingcoils.
PushtheventhandletotheVentClosedposition
(whereapplicable).
Openthefrontpanel.
Graspthefilterbythecenterandpullupand
out.
Washthefilterusingliquiddishwashingdeter-
gentandwarmwater.Rinsefilterthoroughly.
Gentlyshakeexcesswaterfromthefilter.Be
surethefilteristhoroughlydrybeforereplacing.
Or,insteadofwashingyoumayvacuumthe
filterclean.
Neverusehotwaterover40 C(104 F) to
cleantheairfilter.Neverattempttooperatethe
unitwithouttheairfilter.
Besuretounplugtheairconditionertoprevent
shockorfirehazard. Thecabinetandfrontmay
bedustedwithanoil-freeclothorwashedwith
aclothdampenedinasolutionofwarmwater
andmildliquiddishwashingdetergent.Rinse
thoroughlyandwipedry.
Neveruseharshcleaners,waxorpolishonthe
cabinetfront.
Besuretowringexcesswaterfromtheclothbefore
wipingaroundthecontrols.Excesswaterinoraround
thecontrolsmaycausedamagetotheairconditioner.
Pluginairconditioner.
Ifyouplantostoretheairconditionerduringthewinter,
removeitcarefullyfromthewindowaccordingtothe
installationinstructions.Coveritwithplasticorreturnit
totheoriginalcarton.
Note:
CabinetCleaning
WinterStorage
14
WARNING!
104°F (4C)
CARE ANDCLEANING
Cleanyourairconditioneroccasionallytokeepitlookingnew. Besuretounplugtheunit
beforecleaningtopreventchockorfirehazards.
CAUTION
AirFilterCleaning
Theairfiltershouldbecheckedatleastoncea
monthtoseeifcleaningisnecessary. Trapped
particlesinthefiltercanbuildupandcausean
accumulationoffrostonthecoolingcoils.
PushtheventhandletotheVentClosedposition
(whereapplicable).
Openthefrontpanel.
Graspthefilter,pullupandout.
Washthefilterusingliquiddishwashingdeter-
gentandwarmwater.Rinsefilterthoroughly.
Gentlyshakeexcesswaterfromthefilter.Be
surethefilteristhoroughlydrybeforereplacing.
Or,insteadofwashingyoumayvacuumthe
filterclean.
Neverusehotwaterover40 C(104 F) to
cleantheairfilter.Neverattempttooperatethe
unitwithouttheairfilter.
Besuretounplugtheairconditionertoprevent
shockorfirehazard. Thecabinetandfrontmay
bedustedwithanoil-freeclothorwashedwith
aclothdampenedinasolutionofwarmwater
andmildliquiddishwashingdetergent.Rinse
thoroughlyandwipedry.
Neveruseharshcleaners,waxorpolishonthe
cabinetfront.
Besuretowringexcesswaterfromtheclothbefore
wipingaroundthecontrols.Excesswaterinoraround
thecontrolsmaycausedamagetotheairconditioner.
Pluginairconditioner.
Ifyouplantostoretheairconditionerduringthewinter,
removeitcarefullyfromthewindowaccordingtothe
installationinstructions.Coveritwithplasticorreturnit
totheoriginalcarton.
Note:
CabinetCleaning
WinterStorage
18
grille
shock
Owners Manual Room Air Conditioner with R-410A Heat Controller, Inc.
17
Beforecallingforservice,reviewthislist.Itmaysaveyoutimeandexpense. Thislistincludescommon
occurrencesthatarenottheresultofdefectiveworkman-shipormaterialsinthisappliance.
Solution
Airconditioner
doesnotstart
Wallplugdisconnected.Pushplugfirmlyintowalloutlet.
Housefuseblownorcircuitbreakertripped.Replacefusewithtimedelaytypeor
resetcircuitbreaker.
PlugCurrentDeviceTripped.PresstheRESETbutton.
TROUBLESHOOTINGTIPS
Problem
Airfromunitdoes
notfeelcold
enough
ResettoaLowertemperature.
Roomtemperaturebelow17C(62F).Coolingmaynotoccuruntilroomtemperature
risesabove 17C(62F).
Thermostatsettoocoldfornight-timecooling.Todefrostthecoil,settoFANONLY
mode.Then,settemperaturetoaHighersetting.
Temperaturesensingelementtouchingcoldcoil,locatedbehindairfilter.Straighten
tubeawayfromcoil.
Airfiltermaybedirty.Cleanfilter.RefertoCareandCleaningsection.Todefrost,
settoFANONLY mode.
Dirtyairfilter-airrestricted.Cleanairfilter.RefertoCareandCleaningsection.
Unitrecentlyturnedoninhotroom. AllowadditionaltimetoremoveStoredheatfrom
walls,ceiling,floorandfurniture.
ControlisOFF.TurnControlONandsettodesiredsetting.
O
O
O
O
Airconditioner
cooling,butroom
istoowarm-ice
formingoncooling
coilbehind
decorativefront.
Outdoortemperaturebelow18C(64F).Todefrostthecoil,setFANONLY mode.
O
O
Airconditioner
cooling,butroom
istoowarm-NO
iceformingon
coolingcoilbehind
decorativefront.
TemperatureissettooHigh,settemperaturetoaLowersetting.
Airdirectionallouverspositionedimproperly.Positionlouversforbetterairdistribution.
Frontofunitsisblockedbydrapes,blinds,furniture,etc.-restrictsairdistribution.
Clearblockageinfrontofunit.
Doors,windows,registers,etc.Open-coldairescapes.Closedoors,windows,registers.
Compressorshut-offbychangingmodes.Waitapproximately3minutesandlistenfor
compressortorestartwhensetintheCOOL mode.
Airconditionerturnson
andoffrapidly
Noisewhenunitis
cooling
Waterdripping
INSIDEwhen
unitiscooling.
Improperinstallation.Tiltairconditionerslightlytotheoutsidetoallowwaterdrainage.
Refertoinstallationinstructions-checkwithinstaller.
Dirtyairfilter-airrestricted.Cleanairfilter.
Airmovementsound.Thisisnormal.Iftooloud,settoaslowerFANsetting.
Outsidetemperatureextremelyhot.SetFANspeedtoaHighersettingtobringairpast
coolingcoilsmorefrequently.
Windowvibration-poorinstallation.Refertoinstallationinstructionsorcheckwithinstaller.
15
6F (17°C).
6F (17°C).
6F (18°C).
the rear/outside to allow water drainage.
Solution
Problem
Waterdripping
OUTSIDEwhen
unitiscooling.
Unitremovinglargequantityofmoisturefromhumidroom.Thisisnormalduring
excessivelyhumiddays.
RemoteSensing
Deactivating
Prematurely
(somemodels)
Remotecontrolnotlocatedwithinrange.Placeremotecontrolwithin20feet&180,
radiusofthefrontoftheunit.
Remotecontrolsignalobstructed.Removeobstruction.
Roomtoocold
Settemperaturetoolow.Increasesettemperature.
16
Heat Controller, Inc. Room Air Conditioner with R-410A Owners Manual
18
04/2009
11/2009
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Heat Controller RADS-183G Owner's manual

Category
Mobile air conditioners
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI