Performance:
Total Cooling Capacity (Btu/h)
Heang Capacity (Btu/h)
Maximum Power Input (W)1
L/M/H Power Input at Factory Default (W)
Rated capacity is cered under AHRI Standard 1230. Rangs are subject to change without noce. Current
cered rangs are available at www.ahridirectory.org.
Electrical:
Power Supply (V/Hz/Ø)
Rated Amps (A)
208-230/60/1
Piping:
Refrigerant:
Liquid Line (in., O.D.)
Vapor Line (in., O.D.)
Fan:
Type
Fan Quanty
Motor/Drive
Motor Quanty
Standard Mode Airow Rate H/M/L (CFM)
Standard Mode External Stac Pressure (ESP)7 (in. w.g.)
High Mode Airow Rate H/M/L (CFM)
High Mode External Stac Pressure (ESP)7 (in. w.g.)
Airow Range (CFM)
Minimum ESP8
Maximum ESP8
Page 1 of 2
Unit Data:
Refrigerant Type
Refrigerant Control
Sound Pressure dB(A) (H/M/L)5
Filter Type
Filter Quanty
Filter Dimensions6 (in.)
Net Unit Weight (lbs.)
Shipping Unit Weight (lbs.)
R410A
EEV
Washable
1
Entering Mixed Air:
Cooling Maximum3 (°F WB)
Heang Minimum (°F DB)
76
59
Controls Features:
Oponal Accessories:
• Auto changeover (Heat Recovery
only)
• Auto operaon
• Auto restart
• Child lock
• Dual thermistor control
• Hot start
• External on/o control
• Self diagnoscs
• Timer (on/o)
• Weekly schedule
• Fan speed control
• Dual setpoint control
• Mulple auxiliary heater appli-
caons
• Filter life display
• Group control
• Wi-Fi compable
• Auto fan
• Leak detecon
Wireless Remote Controller4 - PQWRHQ0FDB
MulSITE™ CRC1 Controller - PREMTBVC0
MulSITE CRC1+ Controller - PREMTBVC1
Premium Remote Controller - PREMTA000
Simple Remote Controller - PREMTC00U
Wi-Fi Module - PWFMDD200
Simple Dry Contact (1 contact, 24 VAC external power) - PDRYCB100
Dry Contact for Third-Party Thermostat - PDRYCB32014
Dry Contact for Economizer - PDRYCB400
Auxiliary Heater Kit - PRARH114
Remote Temperature Buon Sensor - ZRTBS01
Condensate:
Condensate Pump Drain2 (in., I.D.) 1
Sirocco
Brushless Digitally Controlled/Direct
0
0.1
0
0.19
Notes:
1. Maximum power input is rated at maximum seng value.
2. Maximum li is 27 inches from boom of unit. Check valve not included
(eld supplied).
3. See Engineering Manual for sensible and latent capacies.
4. Requires an LG wall controller because ducted units do not have infrared
receiver.
5. Sound Pressure levels are tested in an anechoic chamber under ISO Stan-
dard 3745.
6. Actual lter sizes may vary.
7. At factory fan speed seng.
8. Maximum stac pressure may result in reduced airow (CFM).
9. All communicaon cable between (main) outdoor units to indoor units /
heat recovery units to be 18 AWG, 2-conductor, twisted, stranded, shielded.
Ensure the communicaon cable shield is properly grounded to the (main)
outdoor unit chassis only. DO NOT ground the outdoor unit to indoor
units / heat recovery units communicaon cable at any other point. Wiring
must comply with all applicable local and naonal codes.
10. Power wiring cable size must comply with the applicable local and
naonal code.
11. This unit comes with a dry nitrogen charge.
12. All capacies are net with a combinaon rao between 95 – 105%.
13. Must follow installaon instrucons in the applicable LG installaon
manual.
14. If a Third-Party Dry Contact and an LG internal heater or an LG Auxiliary
Heater Kit is installed, supplemental heat capability cannot be controlled by
the Third-Party Thermostat.
Multi V™ Low Static Ducted