Unit Dimensions
Unit DimensionsUnit Dimensions
Unit Dimensions
5.13 x 17.53 x 26 in / 13.0 x 44.5 x 66.0 cm
Shipping Dimensions
Shipping DimensionsShipping Dimensions
Shipping Dimensions
14 x 32 x 38.5 in / 35.6 x 81.3 x 97.8cm
Unit Weight
Unit WeightUnit Weight
Unit Weight
160 lbs/73 kg
Shipping Weight
Shipping WeightShipping Weight
Shipping Weight
200 lbs/91 kg
BTU Break Down
BTU Break DownBTU Break Down
BTU Break Down
BTU On Line
BTU On LineBTU On Line
BTU On Line
629
BTU On Battery
BTU On BatteryBTU On Battery
BTU On Battery
2730
Battery String Voltage
Battery String VoltageBattery String Voltage
Battery String Voltage
240V
Battery Type
Battery TypeBattery Type
Battery Type
12V 5ah
Battery Quantity
Battery QuantityBattery Quantity
Battery Quantity
20
Electrical Input
Electrical InputElectrical Input
Electrical Input
Voltage Range
Voltage RangeVoltage Range
Voltage Range
See Model Matrix for nominal and user selectable voltage settings
Frequency
FrequencyFrequency
Frequency
50/60 Hz
Input Plug
Input PlugInput Plug
Input Plug
Part number 326529-D71: L6-30P, 3m cord
Part number 326529-B31: IEC-309 32Amp, 3m cord
Online Efficiency
Online EfficiencyOnline Efficiency
Online Efficiency
95%
REPO
REPOREPO
REPO
Remote Emergency Power-Off disables AC power to load
Electrical Output
Electrical OutputElectrical Output
Electrical Output
Online Regulation
Online RegulationOnline Regulation
Online Regulation
-10% to +6% of nominal voltage
On battery Regulation
On battery RegulationOn battery Regulation
On battery Regulation
±5% of nominal voltage
Voltage Wave Form
Voltage Wave FormVoltage Wave Form
Voltage Wave Form
Sine wave
Connections
ConnectionsConnections
Connections
See Model Selection Matrix; divided into 2 Load Segments
Output Protection
Output ProtectionOutput Protection
Output Protection
Re-settable circuit protectors
Battery
BatteryBattery
Battery
Type
TypeType
Type
Maintenance-free, sealed, valve-regulated lead acid (VRLA)
Extended Batteries
Extended BatteriesExtended Batteries
Extended Batteries
Up to two ERMs supported
Backup Time
Backup TimeBackup Time
Backup Time
See Backup Times Chart
Recharge Time
Recharge TimeRecharge Time
Recharge Time
<3 hours to 80% usable capacity; <24 hours for complete recharge
Communications
CommunicationsCommunications
Communications
Serial Ports
Serial PortsSerial Ports
Serial Ports
Standard DB-9 ports (ships with communication cable)
Option Slot
Option SlotOption Slot
Option Slot
One
Option Cards
Option CardsOption Cards
Option Cards
Six Port Card and SNMP / Serial Port Card
LED Indicators
LED IndicatorsLED Indicators
LED Indicators
LED and switch membrane integrated into the front panel; with four-button
control (three buttons for UPS power control and one button under the front
bezel for configuration).
Environmental and Safety
Environmental and SafetyEnvironmental and Safety
Environmental and Safety
Operating Temperature
Operating TemperatureOperating Temperature
Operating Temperature
50° to 104° F (10° to 40° C )
Transit Temperature
Transit TemperatureTransit Temperature
Transit Temperature
-13° to 131° F (-25° to 55° C)
Storage Temperature
Storage TemperatureStorage Temperature
Storage Temperature
32° to 77° F (0° to 25° C )
Operating Humidity
Operating HumidityOperating Humidity
Operating Humidity
20% to 80% (non-condensing)
Storage Humidity
Storage HumidityStorage Humidity
Storage Humidity
5% to 95%
Operating Altitude
Operating AltitudeOperating Altitude
Operating Altitude
Up to 6,562 ft (2000 m) above sea level
Transit Altitude
Transit AltitudeTransit Altitude
Transit Altitude
49,212 ft (15,000 m) above sea level
Audible Noise
Audible NoiseAudible Noise
Audible Noise
<46db (at 1m from surface of unit)
Safety Markings
Safety MarkingsSafety Markings
Safety Markings
NA/JPN: UL, cUL
Int'l: GS, CE, GOST
QuickSpecs
HP Rack-Mountable R5500 UPS
HP Rack-Mountable R5500 UPSHP Rack-Mountable R5500 UPS
HP Rack-Mountable R5500 UPS
Technical Specifications
DA - 11871 Worldwide — Version 18 — June 21, 2010
Page 11