Pelco pelco hs1500 User manual

Category
Security camera accessories
Type
User manual

This manual is also suitable for

Pelco hs1500 is a high-security camera enclosure designed for indoor corner mount installation. It is suitable for various applications such as elevators, parking garages, classrooms, detention cells, and other places that require protection from vandalism. Constructed of heavy gauge steel, the enclosure fits flush to the ceiling and has no exposed mounting hardware, making it difficult to open by unauthorized personnel. It features an impact-resistant clear Lexan window and a factory-installed tamper switch for added security.

Pelco hs1500 is a high-security camera enclosure designed for indoor corner mount installation. It is suitable for various applications such as elevators, parking garages, classrooms, detention cells, and other places that require protection from vandalism. Constructed of heavy gauge steel, the enclosure fits flush to the ceiling and has no exposed mounting hardware, making it difficult to open by unauthorized personnel. It features an impact-resistant clear Lexan window and a factory-installed tamper switch for added security.

HS1500 High-Security
Enclosure
INSTALLATION
C493M-G (11/97)
C493M-G (11/97) 3
Contents
Important Safeguards and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Ceiling Mounting (Flush) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Mid-wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
HB1500/HB1524 Heater/Blower Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Recommended Cable Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Heater/Blower Kit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Tamper Switch installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Tamper Switch Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Exploded Assembly Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
List of Illustrations
1 HS1500H Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2 Heather/Blower Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3 Heater/Blower Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4 Tamper Switch Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
5 HS1500 Enclosure Exploded Assembly Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
6 HS1500 Enclosure Dimension Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
List of Tables
A HS1500 Enclosure Exploded Assembly Parts Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4 C493M-G (11/97)
Important Safeguards and Warnings
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not
be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify
the exposed parts have not been connected to line circuitry.
5. The installation method and materials should be capable of supporting four times the weight of the enclosure, pan/tilt, camera and lens
combination.
6. The camera and lens combination shall not exceed 20 lbs (9.09 kg).
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is
present within this unit.
This symbol indicates that there are important operating and maintenance instructions
in the literature accompanying this unit.
CAUTION:
To reduce the risk of electrical shock, do not remove cover. No user-
servicable parts inside. Refer servicing to qualified service personnel.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
C493M-G (11/97) 5
Description
The HS1500 is a high security camera enclosure of medium size designed for indoor “corner mount” installation for such applications as
elevators, parking garages, classrooms, detention cells, etc., requiring maximum protection from vandalism in an unobtrusive package. Designed
to fit flush to the ceiling in a corner, an optional hood (HS1500H) allows the HS1500 to be mounted lower on the wall and still retain the
enclosure’s integrity. An impact-resistant clear Lexan window is supplied.
Constructed of heavy gauge steel, the HS1500 will accept most small CCD cameras with fixed focal length lenses ranging in size from 4 mm to
75 mm. There is no exposed mounting hardware securing the HS1500 to its mounting surface. Opening the enclosure can only be accomplished
with a specially designed tool, eliminating the possibility of the enclosure being opened by unauthorized personnel. In addition, a factory-
installed tamper switch is mounted on the secured access cover.
MODELS
HS1500 High security corner mount enclosure designed to fit flush with the ceiling. For use in applications such as elevators,
parking garages, classrooms, detention cells, etc., requiring maximum protection from vandalism in an unobtrusive
package.
OPTIONS
HB1500 120 VAC thermostatically controlled heater. Provides 80 watts of heat which activates ON at 40°F; OFF at 60°F.
Also includes fan that provides continuous internal air circulation.
HB1524 Same as HB1500 except 24 VAC thermostatically controlled heater.
HS1500H Hood for mid-wall mounting of HS1500 enclosure.
6 C493M-G (11/97)
Installation
NOTE:
The four (4) fasteners required to secure the HS1500 to a wall (minimum 3/8” diameter recommended) are not supplied.
Before installing the HS1500 to a wall, make certain that the mounting surface is able to support the full weight of the enclosure plus the camera
and lens.
The tilt table and tilt table mounting brackets may be removed to provide adequate clearance for mounting the enclosure.
CEILING MOUNTING (FLUSH)
To mount the enclosure to a wall (tight to the ceiling), follow the steps outlined below.
1. Remove the cover from the mounting bracket. A special socket is provided (fits 1/4" square drive).
2. Using the mounting bracket (see Figure 4) or the template provided, mark and drill holes in the mounting surface.
NOTE:
A plate is provided to prevent access through the top of this enclosure. If needed, it is mounted with the mounting bracket using the
same mounting holes and hardware
3. Attach the enclosure with the required fasteners.
4. Route the required cables through the back and/or top.
5. Mount the camera/lens to the tilt table.
6. Make all appropriate connections (i.e., camera power, video (coax), lens).
7. Position the camera and tighten the 1/4-20 fasteners to secure the tilt table in place.
8. Replace the cover and check that all components clear. Secure the cover with the 1/4-20 “Tampruf” screw provided.
MID-WALL MOUNTING
To mount the HS1500 enclosure mid-wall, use the optional hood, HS1500H, and
perform the following steps (see Figure 1):
1. Determine the position for the hood. Using it as a template, mark and drill
holes in the mounting surface.
2. Attach the hood with the required fasteners (minimum 3/8" diameter
recommended).
3. Continue with steps 1-8 listed above in Ceiling Mounting section.
Figure 1. HS1500H Installation
C493M-G (11/97) 7
(
8 C493M-G (11/97)
(This page intentionally left blank)
C493M-G (11/97) 9
HB1500/HB1524 HEATER/BLOWER KIT
The HB1500/HB1524 heater/blower kits require either 120 VAC or 24 VAC, respectively. The heater provides 80 watts of heat and is
thermostatically controlled to turn on at 40°F (4.44°C) and turn off at 60°F (15.56°C). The three-watt fan is on continously to provide internal air
circulation.
RECOMMENDED CABLE SIZE
The following cable sizes are the minimum recommended for use with the combination of blower/heater/camera.
CAUTION:
When using a single power source for both the camera and accessories, the camera power consumption must be taken into
consideration when determining the wire gauge.
Model Input Voltage Power Consumption Cable Size Cable Distance
HB1500 120 VAC 85 Watts 22 Awg
20 Awg
18 Awg
18 Awg
524 ft (160 m)
834 ft (254 m)
1327 ft (404 m)
2107 ft (642 m)
HB1524 24 VAC 85 Watts 20 Awg
18 Awg
16 Awg
14 Awg
33 ft (10 m)
53 ft (16 m)
84 ft (26 m)
134 ft (41 m)
10 C493M-G (11/97)
HEATER/BLOWER KIT INSTALLATION
To install the HB1500/HB1524 heater/blower kit, perform the following steps:
1. Remove the cover (Figure 5, item 4).
2. Attach the heater pads to each side of the mounting frame, below the tilt table assembly.
3. Attach the PC board/fan assembly to the mounting frame, to the left or right of the tilt table assembly (see Figure 2).
4. The blower is factory wired to the PCB assembly.
5. Close and lock the cover.
Figure 2.
Heather/Blower Installation
Connect the heaters to the PCB assembly as shown in Figure 3.
Figure 3.
Heater/Blower Wiring Diagram
C493M-G (11/97) 11
TAMPER SWITCH INSTALLATION
The HS1500 enclosure comes standard from the factory with a tamper switch installed. Should it become necessary to install a replacement
switch, refer to Figure 4 for the correct position of the bracket/switch and perform the following steps:
1. Remove the front cover.
2. Install the bracket/switch and secure with lockwashers and nuts.
TAMPER SWITCH WIRING
The tamper switch comes with both a “Normally Open” and a “Normally Closed” contact.
For a “Normally Open” circuit, use the “open” and “common” terminals; for a “Normally Closed” circuit, use the “closed” and “common”
terminals.
Figure 4.
Tamper Switch Installation
Maintenance
Maintenance performed at regularly scheduled intervals will help prolong the operational life and appearance of the equipment.
Clean the Lexan window with a mild non-abrasive detergent in water and a soft cloth regularly to help maintain picture clarity. For a heavily
soiled window, use vinyl cleaner.
12 C493M-G (11/97)
Exploded Assembly Diagram
Figure 5.
HS1500 Enclosure Exploded Assembly Diagram
Table A.
HS1500 Enclosure Exploded Assembly Parts Lists
Item No. Qty Description Part Number
1
2
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
Bracket, switch, break-in
Window, 10" x 9" x .50" drilled MR5 clear Lexan
Plate, mounting
Cover, front
Tilt table
Cover, top, corner mount
Bracket, mount, tilt table, left
Bracket, mount, tilt table, right
Switch, tamper
HS10004313COMP
HS150010009
HS15004001COMP
HS15004003COMP
HS15004008COMP
HS15004023COMP
HS20004115COMP
HS20004215COMP
SWI1DM401
A
B
C
D
E
F
G
H
I
J
2
1
2
2
2
4
7
4
4
1
Screw, 1/4-20 x 1/2", round, Tampruf #10, SS
Screw, 1/4-20 x 3/4", round, Tampruf #10, SS
Tape, two-sided, acrylic x inch
Bolt, 1/4-20 x 5/8" hex head C/S, SS
Nut, hex, 1/4-20, SS
Washer, split lock, 1/4" SS
Washer, flat 3/16" special, SS
Washer, flat 15/16", SS
Nut, lock 1-4/20 Nylon insert, SS
Socket, Tampruf #10, 1/4" drive (not shown)
ZH1/4-20X.50SRT
ZH1/4-20X.75SRT
ZHTAPE1.00X.025
ZH1/420X.625CH
ZH1/4-20NUTCH
ZH1/4LWSSL
ZH260X562X65C
ZH932X1.75X130
ZH1/420NUTCHN
ZTSOCKET10
C493M-G (11/97) 13
Specifications
MECHANICAL
Window 1/2" (12.7 mm) thick impact and abrasion resistant clear Lexan
Camera Mounting Adjustable tilt table
Maximum Camera/Lens Size Accepts camera/lens combinations (including BNC connector) up to: 8.0" L x 4.0" W x 4.0" H
(20.32 cm x 10.16 cm x 10.16 cm)
Enclosure Mounting Four (4) .390" (.99 cm) diameter holes on protected rear surface
Security Tamper-resistant screw. N.O./N.C. switch contact on cover
Tamper Switch Plunger type door switch with “pull to cheat” feature N.O/N.C. contacts clearly marked on body of switch.
DM electrical rating 10A, 125V.
ELECTRICAL
Cable Entry Access through back and top
Tamper Switch Wire Leads 1/4" (0.63 cm) quick connect
N.O./N.C. clearly marked on switch body
10A, maximum switching current
125V, maximum switching voltage
GENERAL
Construction Formed 10 gauge 0.134" (0.34 cm) steel
Finish Polyester powder coat
Dimensions See Figure 6
Environment Indoor; 32° to 120° (0° to 48.89° C)
Unit Weight 15 lbs 4 oz (6.77 kg)
(Design and product specifications subject to change without notice.)
Figure 6.
HS1500 Enclosure Dimension Drawing
14 C493M-G (11/97)
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship
for a period of one year
after the date of shipment.
Exceptions to this warranty are as noted below:
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex
®
Series products (multiplexers, server, and keyboard).
• Three years on Camclosure
®
and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy
®
, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
fixed dome products.
Two years on Spectra
®
, Esprit
®
, ExSite
, and PS20 scanners, including when used in
continuous motion applications.
Two years on Esprit
®
and WW5700 Series window wiper (excluding wiper blades).
Two years (except lamp and color wheel) on Digital Light Processing (DLP
®
) dis-
plays. The lamp and color wheel will be covered for a period of 90 days. The air
filter is not covered under warranty.
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura
Series distributed network-based video products.
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
REVISION HISTORY
Manual # Date Comments
C493M 5/90 Original manual.
C493M 1/91 Rev. A. Revised to include HB1524 and HS1500H options and heater/blower kit information.
C493M 5/91 Rev. B. Figure 2, HS1500H Installation added.
C493M 11/93 Rev. C. Exploded assembly diagram and parts list updated.
C493M-D 9/95 Rev. D. Revised to include wiring instructions for tamper switch and metric equivalents for specifications. Heater/blower wiring diagram updated to include 24 VAC
model.
C493M-E 11/95 Rev. E. Revised to include updated tamper switch/bracket part numbers and exploded view diagram.
C493M-F 1/96 Rev. F. Revised to include updated specification description, installation instructions, and part numbers for tamper switch update per ECO 95-397.
C493M-G 11/97 Rev. G. Revised to new format. Updated heater-blower information to indicate blower operated in continuous duty mode.
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. ©Copyright 1997, Pelco. All rights reserved.
Endura and ExSite are trademarks of Pelco.
DLP is a registered trademark of Texas Instruments, Inc.
Worldwide Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
www.pelco.com
ISO9001
United States
|
Canada
|
United Kingdom
|
The Netherlands
|
Singapore
|
Spain
|
Scandinavia
|
France
|
Middle East
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Pelco pelco hs1500 User manual

Category
Security camera accessories
Type
User manual
This manual is also suitable for

Pelco hs1500 is a high-security camera enclosure designed for indoor corner mount installation. It is suitable for various applications such as elevators, parking garages, classrooms, detention cells, and other places that require protection from vandalism. Constructed of heavy gauge steel, the enclosure fits flush to the ceiling and has no exposed mounting hardware, making it difficult to open by unauthorized personnel. It features an impact-resistant clear Lexan window and a factory-installed tamper switch for added security.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI