Redlion CUB5V Installation guide

Type
Installation guide

This manual is also suitable for

Install CUB5V- A
Drawing No. LP1137
Effective 07/2020
Model CUB
®
5V - Miniature Electronic
5-Digit DC Voltmeter
Installation Guide
1
See the Red Lion website at www.redlion.net for full user manual.
SAFETY SUMMARY
All safety related regulations, local codes as well as instructions
that appear in this document or on equipment must be observed
to ensure personal safety and to prevent damage to either the
device or equipment connected to it.
Do not use these products to replace proper safety interlocking.
No software-based device (or any other solid-state device) should
ever be designed to be responsible for the maintenance of
personnel safety or consequential equipment not equipped with
safeguards. Red Lion disclaims any responsibility for damages,
either direct or consequential, that result from the use of this
equipment in a manner not consistent with these specifications.
ORDERING INFORMATION
PART NUMBER DESCRIPTION TYPE
CUB5VR00 DC Volt Meter with reflective display
CUB5
CUB5VB00 DC Volt Meter with backlight display
CUB5RLY0 Single Relay Option Card
Optional
Plug-in
Cards
CUB5SNK0 Dual Sinking Open Collector Output card
CUB5COM1 RS485 Serial Communications Card
CUB5COM2 RS232 Serial Communications Card
CUB5USB0 USB Programming Card
SPECIFICATIONS
1. POWER: Input voltage range is +9 to +28 VDC with short
circuit and input polarity protection. Must use an RLC model
MLPS or an NEC Class 2 or Limited Power Source (LPS) rated
power supply.
MODEL NO. DISPLAY COLOR
INPUT CURRENT
@ 9 VDC
WITHOUT
CUB5RLY0
INPUT
CURRENT @
9 VDC WITH
CUB5RLY0
CUB5VR00 --- 10 mA 40 mA
CUB5VB00 Red (max intensity) 85 mA 115 mA
CUB5VB00 Green (max intensity) 95 mA 125 mA
2. DISPLAY: 5 digit LCD 0.48" (12.2 mm) high digits
CUB5VR00: Reflective LCD with full viewing angle
CUB5VB00: Transmissive LCD with selectable red or green
LED backlight, viewing angle optimized. Display color change
capability with output state when using an output module.
3. INPUT RANGES: Jumper Selectable
D.C. Voltages: 200 mV, 2 V, 20 V, 200 V
4. RESPONSE TIME:
Display: 500 msec min.
Output: 800 msec max (with input filter setting of 0)
5. USER INPUT (USR): Programmable input. Connect terminal
to common (USR COMM) to activate function. Internal 10K
pull-up resistor to +9 to 28 VDC.
6. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range for CUB5VR00: -35 to 75°C
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
C
C
US LISTED
US LISTED
U
L
R
IND. CONT. EQ.
E137808
.13 (3.3)
(43.4)
1.71
2.95 (74.9)
SEL
.15 (3.8)
1.54 (39.1)
RST
(68 )
+.025
-.000
+8
-0
1.29 (32.8)
2.68
-.000
1.30
(33 )
-0
+6
+.024
DIMENSIONS In inches (mm)
Note: Recommended minimum clearance (behind the panel) for mounting
clip installation is 2.15" (54.6) H x 3.00" (76.2) W.
2
Drawing No. LP1137 Effective 07 2020
Operating Temperature Range for CUB5VB00 depends on
display color and intensity level as per below:
INTENSITY LEVEL TEMPERATURE
Red Display
1 & 2 -35 to 75°C
3 -35 to 70°C
4 -35 to 60°C
5 -35 to 50°C
Green Display
1 & 2 -35 to 75°C
3 -35 to 65°C
4 -35 to 50°C
5 -35 to 35°C
Storage Temperature: -35 to 85°C
Operating and Storage Humidity: 0 to 85% max. relative
humidity (non-condensing)
Vibration to IEC 68-2-6: Operational 5-500 Hz, 5 g
Shock to IEC 68-2-27: Operational 30 g
Altitude: Up to 2000 meters
Installation Category I, Pollution Degree 2
7. CERTIFICATIONS AND COMPLIANCES:
CE Approved
EN 61326-1 Immunity to Industrial Locations
Emission CISPR 11 Class A
IEC/EN 61010-1
RoHS Compliant
UL Listed: File # E137808
Type 4X Indoor/Outdoor Enclosure rating (Face only)
IP65 Enclosure rating (Face only)
IP20 Enclosure rating (Rear of unit)
8. CONNECTIONS: Wire clamping screw terminals
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 3.5 inch-lbs (0.395 N-m) max.
9. CONSTRUCTION: This unit is rated for Type 4X/IP65
requirements for indoor/outdoor use. High impact plastic case
with clear viewing window. Panel gasket and mounting clip
included.
10. WEIGHT: 3.2 oz (100 g)
INSTALLING THE METER
Installation
The meter meets NEMA 4X/IP65 requirements when properly
installed. The unit is intended to be mounted into an enclosed
panel. Prepare the panel cutout to the dimensions shown.
Remove the panel latch from the unit. Slide the panel gasket over
the rear of the unit to the back of the bezel. The unit should be
installed fully assembled. Insert the unit into the panel cutout.
While holding the unit in place, push the
panel latch over the rear of the unit so that
the tabs of the panel latch engage in the
slots on the case.
The panel latch should be engaged in the farthest forward slot
possible. To achieve a proper seal, tighten the latch screws evenly
until the unit is snug in the panel (Torque to approx. 28 to 36 in-oz
[0.202 to 0.26 N-m]). Do not over-tighten the screws.
Installation Environment
The unit should be installed in a location that does not exceed
the operating temperature and provides good air circulation.
Placing the unit near devices that generate excessive heat should
be avoided.
The bezel should only be cleaned with a soft cloth and neutral
soap product. Do NOT use solvents. Continuous exposure to
direct sunlight may accelerate the aging process of the bezel.
Do not use tools of any kind (screwdrivers, pens, pencils, etc.)
to operate the keypad of the unit.
SETTING THE JUMPERS
Input Range Jumper
This jumper is used to select the proper input range. The input
range selected in programming must match the jumper setting.
Select a range that is high enough to accommodate the maximum
input to avoid overloads. To access the jumper, remove the rear
cover of the meter.
WARNING: Exposed line voltage exists on the circuit
boards. Remove all power to the meter and load circuits
before accessing inside of the meter.
Remove/Replace The Rear Cover
To remove the rear cover, locate the cover locking tab below
the 2nd and 3rd input terminals. To release the tab, insert a small,
flat blade screwdriver between the tab and the plastic wall below
the terminals. Inserting the screwdriver will provide enough
pressure to release the tab locks. To replace the cover, align the
cover with the input terminals and press down until the cover
snaps into place.
PANEL
GASKET
BEZEL
PANEL
MOUNTING SCREW
NUT FASTENER
MOUNTING CLIP
2.68
(68 )
+.8
1.30
-.0
(33 )
-.000
+.6
-.0
-.000
+.024
+.025
INPUT RANGE JUMPER
MAIN CIRCUIT
BOARD
200VDC
2VDC
INPUT RANGE
JUMPER LOCATION
200mV/
20V/
3
Effective 07 2020 Drawing No. LP1137
WIRING THE METER
Wiring Overview
Electrical connections are made via screw-clamp terminals
located on the back of the meter. All conductors should conform
to the meter’s voltage and current ratings. All cabling should
conform to appropriate standards of good installation, local codes
and regulations. It is recommended that the power supplied to
the meter (DC or AC) be protected by a fuse or circuit breaker.
Strip the wire, leaving approximately 0.3" (7.5 mm) bare lead
exposed (stranded wires should be tinned with solder.) Insert the
lead under the correct screw-clamp terminal and tighten until the
wire is secure. (Pull wire to verify tightness.) Each terminal can
accept up to one #14 AWG (2.55 mm) wire, two #18 AWG (1.02
mm), or four #20 AWG (0.61 mm).
Power Wiring
User Input Wiring
Input Wiring
USR COMM
USR
+9-28 VDC
COMM
INP +
PWR COMMON
+
-
DC Power
+9 to +28 VDC: +VDC
Power Common: -VDC
CAUTION: 9 to 28
VDC power circuit is
not isolated from the
signal circuit.
CAUTION: Power input common is NOT isolated from user and input commons. In order to preserve the safety of the
meter application, the power input common must be suitably isolated from hazardous live earth referenced voltage;
or input common must be at protective earth ground potential. If not, hazardous voltage may be present at the signal
or user inputs and input common terminals. Appropriate considerations must then be given to the potential of the
user and input commons with respect to earth ground; and the common of the plug-in cards with respect to input common.
Before connecting signal wires, the Input Range Jumper should be verified for proper position.
USR COMM
USR
+9-28 VDC
COMM
INP +
PWR COMMON
Sinking Logic
USR COMM
USR
The user input of the meter is
internally pulled up to +9 to
+28 V with 10 K resistance.
The input is active when it is
pulled low (<0 .7 V).
}
Connect external switching device between the
User Input terminal and User Input Common.
JUMPER
POSITION
MAX INPUT
VOLTAGE
200 mV2 VDC 75 VDC
20V200 VDC 250 VDC
Voltage Signal (self powered)
-
+
COMM
INP+
The remaining wiring information only applies to optional plug-in cards.
Setpoint (Output) Wiring
COM
N.C.
N.O.
COM
N.O.
N.C.
OSNK1
OSNK2
COM
Output Common is not isolated from DC Power Common.
Load must be wired between OSNK terminal and V+ of the
load supply.
CO
M
OSNK 1(2)
(30 V MAX.)
SINGLE SETPOINT RELAY PLUG-IN CARD
ELECTRICAL CONNECTIONS
DUAL SETPOINT N-FET OPEN DRAIN PLUG-IN CARD
ELECTRICAL CONNECTIONS
4
Drawing No. LP1137 Effective 07 2020
Communication Wiring
SERIAL COMMUNICATIONS PLUG-IN CARD
RJ11 CONNECTOR PIN OUTS
N/C
RS485
2
COMM
A+
B-
N/C
534
N/C
RS232
5
N/C
TX
N/C
43
COMM
COMM
2
RX
61
61
RED LION CONTROLS TECHNICAL SUPPORT
If for any reason you have trouble operating, connecting, or
simply have questions concerning your new unit, contact Red
Lion’s technical support.
Support: support.redlion.net
Website: www.redlion.net
Inside US: +1 (877) 432-9908
Outside US: +1 (717) 767-6511
COPYRIGHT
©2020 Red Lion Controls, Inc. All rights reserved. Red Lion
and the Red Lion logo are trademarks of Red Lion Controls,
Inc. All other company and product names are trademarks of
their respective owners.
USB PROGRAMING PLUG-IN CARD
LIMITED WARRANTY
(a) Red Lion Controls Inc. (the “Company”) warrants that all Products shall be free from defects in material and
workmanship under normal use for the period of me provided in “Statement of Warranty Periods” (available at
www.redlion.net) current at the me of shipment of the Products (the “Warranty Period”). EXCEPT FOR THE
ABOVE-STATED WARRANTY, COMPANY MAKES NO WARRANTY WHATSOEVER WITH RESPECT TO THE
PRODUCTS, INCLUDING ANY (A) WARRANTY OF MERCHANTABILITY; (B) WARRANTY OF FITNESS FOR
A PARTICULAR PURPOSE; OR (C) WARRANTY AGAINST INFRINGEMENT OF INTELLECTUAL PROPERTY
RIGHTS OF A THIRD PARTY; WHETHER EXPRESS OR IMPLIED BY LAW, COURSE OF DEALING, COURSE
OF PERFORMANCE, USAGE OF TRADE OR OTHERWISE. Customer shall be responsible for determining that a
Product is suitable for Customer’s use and that such use complies with any applicable local, state or federal law.
(b) The Company shall not be liable for a breach of the warranty set forth in paragraph (a) if (i) the defect is a
result of Customer’s failure to store, install, commission or maintain the Product according to specicaons; (ii)
Customer alters or repairs such Product without the prior wrien consent of Company.
(c) Subject to paragraph (b), with respect to any such Product during the Warranty Period, Company shall, in its
sole discreon, either (i) repair or replace the Product; or (ii) credit or refund the price of Product provided that,
if Company so requests, Customer shall, at Company’s expense, return such Product to Company.
(d) THE REMEDIES SET FORTH IN PARAGRAPH (c) SHALL BE THE CUSTOMER’S SOLE AND EXCLUSIVE
REMEDY AND COMPANY’S ENTIRE LIABILITY FOR ANY BREACH OF THE LIMITED WARRANTY SET
FORTH IN PARAGRAPH (a).
BY INSTALLING THIS PRODUCT, YOU AGREE TO THE TERMS OF THIS WARRANTY, AS WELL AS ALL OTHER
DISCLAIMERS AND WARRANTIES IN THIS DOCUMENT.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4