If a condition exists where the unit may ignite the rear burner at
the orifice an air shield bracket, part number 121005-01 may be
installed to prevent this.
To install bracket:
1. Turn off unit and allow to cool.
2. Turn off gas supply to unit.
3. Remove all logs from unit (see owner ’s manual).
4. Using two 9/16" open end wrenches, hold rear injector and
loosen compression nut (see Figure 1).
AIR SHIELD BRACKET 121005-01
INSTALLATION INSTRUCTIONS
For more information, visit IHP.US.com
Injector
Chassis
Injector
Burner Tube
Lower Edge of
Burner Flange
5. Pull tube away from injector approximately 1" (see Figure 2).
6. Firmly holding burner, loosen and remove injector from rear
burner using a wrench if necessary (see Figure 3). Be sure to
hold firmly to burner as the flange will bend if force is used.
7. Inspect position of rear burner to insure lower edge of burner
flange is parallel to corresponding notch in chassis (see Figure
4). If burner is not in this position, twist burner into position
by hand.
Figure 1 - Loosen Compression Nut Using Two 9/16" Open End
Wrenches
Figure 2 - Pull Burner Tube Away From Injector
Figure 3 - Loosen Injector While Holding Burner Firmly
Figure 4 - Lower Edge of Burner Flange Should be Parallel to
Edge of Chassis
WARNING
Installation of this bracket must be done by a qualified
service person.
Innovative Hearth Products reserves the right to make changes at any time, without notice, in
design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2014 Innovative Hearth Products LLC
P/N 121084-01 Rev. C 02/2016 1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
8. Position air shield bracket (121005-01) against flange on right
end of burner as shown in Figure 5.
9. Insert injector back into center and tighten finger tight (see
Figure 6).
10. Push tube back toward injector and start compression nut onto
injector (see Figure 7).
11. Using two 9/16" wrenches, hold injector in place and tighten
compression nut onto injector. Do not rotate injector.
12. Inspect position of rear burner to insure lower edge of burner
flange is parallel to corresponding notch in chassis (see Figure
4, page 1). If burner is not in this position, twist burner into
position by hand.
13. Restore gas supply to unit. Start unit and carefully check
connection between injector and tube with noncorrosive leak
detection fluid.
14. Replace logs (see owner’s manual).
Figure 5 - Install Air Shield Bracket #121005-01
Figure 6 - Reinstall Injector
Figure 7 - Reposition Tube Into Injector and Start Compression
Nut Onto Injector
Figure 8 - Tighten Compression Nut Onto Injector Using Two
9/16" Open End Wrenches
Injector