Rinnai EHFA400S48 User manual

Type
User manual

This manual is also suitable for

Hotflo - Vitreous Enamel - Electric Hot Water
Operation & Installation Manual
Rinnai 2 HotoElectricStorageWaterHeaterOIM
CongratulationsonthepurchaseofyourHotoMainsPressureVitreousEnamelElectricStorageWaterHeater.
Wetrustyouwillhavemanyyearsofcomfortandenjoymentfromyourappliance.
IMPORTANT
BEFORE INSTALLING OR USING THIS APPLIANCE
Before proceeding with the operation or installation read this manual thoroughly and gain a full
understanding of the appliance, to ensure safe and correct installation and use.
This appliance must be installed in accordance with:
• Manufacturers Installation Instructions
• Current AS/NZS 3000 & AS/NZS 3500
• Plumbing Code of Australia (PCA)
• Local Regulations and Municipal Building Codes
including local OH&S requirements
This appliance must be installed, maintained and removed
ONLY by an Authorised Person.
For continued safety of this appliance it must be installed
and maintained in accordance with the manufacturers
instructions.
This Appliance complies
with current AS 3498
SAI GLOBAL LIC. WMKA21244
SAI GLOBAL LIC. WMKA00169
Rinnai 3 HotoElectricStorageWaterHeaterOIM
TABLE OF CONTENTS
Warnings & Safety 4
Regulatory ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 4
NoticeToVictorianConsumers ��������������������������������������������������������������������������������������������������������������������������������������������� 4
Safety������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 5
HydrogenGas������������������������������������������������������������������������������������������������������������������������������������������������������������������������ 5
WaterTemperature ���������������������������������������������������������������������������������������������������������������������������������������������������������������� 5
ScaldHazards ����������������������������������������������������������������������������������������������������������������������������������������������������������������������� 5
SafetyDevices ����������������������������������������������������������������������������������������������������������������������������������������������������������������������� 6
Pressure&TemperatureRelief(PTR)Valve ������������������������������������������������������������������������������������������������������������������������� 6
ExpansionControlValve(ECV) ��������������������������������������������������������������������������������������������������������������������������������������������� 6
Important Information 7
Anode ������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������ 7
WaterQuality ������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 7
OperationalOverview ������������������������������������������������������������������������������������������������������������������������������������������������������������ 7
TurningWaterHeatingSystem‘OFF’ ������������������������������������������������������������������������������������������������������������������������������������ 7
TurningWaterHeatingSystem‘ON’ �������������������������������������������������������������������������������������������������������������������������������������� 7
Draining �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 7
Care & Maintenance 8
SaveAServiceCall ��������������������������������������������������������������������������������������������������������������������������������������������������������������� 8
PeriodicMaintenance&Servicing ����������������������������������������������������������������������������������������������������������������������������������������� 8
Specications 9
ApplianceComponents���������������������������������������������������������������������������������������������������������������������������������������������������������� 9
Table1.Dimensions ����������������������������������������������������������������������������������������������������������������������������������������������������������� 10
Installation Methods 11
Table2.Ratings&OtherSpecications �������������������������������������������������������������������������������������������������������������������������������11
HotWaterPlumbingSystemExample-NoTLD ����������������������������������������������������������������������������������������������������������������� 12
HotWaterPlumbingSystemExample-WithTLD��������������������������������������������������������������������������������������������������������������� 12
Installation 13
HotWaterPlumbingsystemExample/Flow&ReturnPipeWork-NoTLD ���������������������������������������������������������������������� 13
HotWaterPlumbingSystemExample/Flow&ReturnPipeWork-WithTLD ������������������������������������������������������������������� 13
Location ������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 14
WaterQuality ����������������������������������������������������������������������������������������������������������������������������������������������������������������������� 14
MainsPressure �������������������������������������������������������������������������������������������������������������������������������������������������������������������� 14
ThermostatSetting �������������������������������������������������������������������������������������������������������������������������������������������������������������� 15
ReducingTheRiskOfScalding ������������������������������������������������������������������������������������������������������������������������������������������� 15
PlumbingConnections ��������������������������������������������������������������������������������������������������������������������������������������������������������� 15
Connectionstothewaterheater ������������������������������������������������������������������������������������������������������������������������������������������ 15
WaterPipes ������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 15
PressureandTemperatureRelief(PTR)Valve �������������������������������������������������������������������������������������������������������������������� 16
ExpansionControlValve(ECV) ������������������������������������������������������������������������������������������������������������������������������������������� 16
PressureLimitingValve(PLV) ��������������������������������������������������������������������������������������������������������������������������������������������� 16
ReliefValveDrainLines ������������������������������������������������������������������������������������������������������������������������������������������������������� 16
ElectricalSupply ������������������������������������������������������������������������������������������������������������������������������������������������������������������ 17
ElectricalConnections ��������������������������������������������������������������������������������������������������������������������������������������������������������� 17
Commissioning 18
WiringDiagrams ������������������������������������������������������������������������������������������������������������������������������������������������������������������ 18
ThermostatSetting ������������������������������������������������������������������������������������������������������������������������������������������������������������� 18
Toll&turn‘ON’thewaterheater �������������������������������������������������������������������������������������������������������������������������������������� 19
Toturn‘OFF’thewaterheater �������������������������������������������������������������������������������������������������������������������������������������������� 19
Contacts 20
Rinnai 4 HotoElectricStorageWaterHeaterOIM
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and to ensure
optimum performance.
Failure to carefully read and follow all instructions in this manual can result in equipment
malfunction, property damage, personal injury and/or death.
YourRinnaiHotoMainsPressureVitreousEnamelElectricStorageWaterHeaterhasbeen
certied by relevant plumbing and electrical authorities and the details are shown on data
plate.
WARNINGS:WHENIGNORED,CANRESULTINSERIOUSINJURYORDEATH.
CAUTIONS:WHENIGNORED,CANRESULTINMINORINJURYORPRODUCTDAMAGE.
REGULATORY
WARNING
This appliance shall be installed in accordance with these instructions and all regulatory
requirements which exist in your area including those in relation to manual lifting, working at
heightsandonroofs.Applicablepublicationsandregulationsmayinclude:
AS/NZS3500NationalPlumbingandDrainage
AS/NZS3000Wiringrules
PlumbingCodeofAustralia(PCA)
BuildingCodesofAustralia(BCA)
LocalOccupationalHealthandSafety(OH&S)regulations
LocalRegulationsandMunicipalBuildingCodes
DO NOToperatethissystembeforereadingthemanufacturersinstructions.
This appliance must be installed, commissioned and serviced by an authorised person in
accordancewithallapplicablelocalrulesandregulations.
Forcontinuedsafetyofthisapplianceitmustbeinstalled,operatedandmaintainedinaccordance
with the manufacturers instructions.
Thisapplianceisheavy,use2peopleormechanicalliftingdevice.Improperliftingmayresultin
serious injury.
Takecarewhenopeningorunpackingthisappliance.Failuretodosomayresultinseriousinjury
or product failure.
DO NOT modify the electrical wiring of this appliance. If the control power wiring is damaged
ordeterioratedthenitmustbereplacedbyanauthorisedperson.Failuretodosomayresultin
electricshock,re,seriousinjuryorproductfailure.
Removaloftheaccesscoversofwaterheatingsystemwillexpose240VwiringandMUSTOnly
beremovedbyanauthorisedperson.
CareshouldbetakennottotouchthepipeworkasitmaybeHOT!
DO NOT place articles on or against this appliance.
DO NOTstorechemicalsorammablematerialsnearthisappliance.
DO NOT operate with collectors or covers removed from this appliance.
DO NOT activate pump unless cylinder is full of water.
Thisapplianceisnotsuitableforuseasadomesticspapoolorswimmingpoolheater.
NOTICE TO VICTORIAN CONSUMERS
WARNING
ThisapplianceMUST BEinstalledbyapersonlicensedwiththeVictorianBuildingAuthority.
ONLY a licensed person will have insurance protecting their workmanship.
So make sure you use a licensed person to install this appliance and ask for your Compliance
Certicate.
ForfurtherinformationcontacttheVictorianBuildingAuthorityon1300815127
IMPORTANT
WARNINGS & SAFETY
Rinnai 5 HotoElectricStorageWaterHeaterOIM
SAFETY
WARNING
ThisapplianceisNOTintendedforusebypersons(includingchildren)withreducedphysical,
sensoryormentalcapabilities,orlackofexperienceandknowledgeunlesstheyhavebeengiven
supervision or instruction concerning use of the appliance by a person responsible for their
safety.
ChildrenshouldbesupervisedtoensurethattheyDONOT play with the appliance.
Hydrogen Gas
Ifthehotwaterheaterisnotusedfortwoweeksormore,aquantityofhydrogengas,whichishighlyammable,
mayaccumulateinthewaterheater.Todissipatethissafety,itisrecommendedthatanonelectricallyoperated
hottapbeturnedonforseveralminutesatasink,orbath,butnotadishwasherorotherappliance.Duringthis
proceduretheremustbenosmoking,openameoranyelectricalapplianceoperatingnearby.Ifhydrogengasis
dischargedthroughthetap,itwillprobablymakeasoundlikeairescaping.
Water Temperature
TomeetregulatoryrequirementsthetemperatureofstoredwaterMUST NOT belessthan60°C.Thethermostat
onyourwaterheaterisfactorypre-setto70°C.Thethermostatsettingcanbeadjustedbetween60°Cand70°C
byanelectricianorothersuitablyqualiedtradesperson.
WARNING
ThethermostatsettingmustonlybeadjustedbyanElectricianorothersuitablyqualiedtrades
person.
TheaccesscovertotheelementandthermostatmustonlyberemovedbyanElectricianorother
suitablyqualiedtradesperson.
SCALD HAZARDS
Hot Water can cause scalds.
Children, disabled, and the elderly are at the highest risk of
being scalded.
Feel water temperature before bathing or showering.
Scalds from hot water taps can result in severe injuries to
young children.
Scalds can occur when children are exposed directly to hot
water when they are placed into a bath which is too hot.
Always......
Testthetemperatureofthewaterwithyourelbowbeforeplacingyourchildinthebath,alsocarefullyfeel
waterbeforebathingorshoweringyourself.
Supervisechildrenwhenevertheyareinthebathroom.
Makesurethatthehotwatertapisturnedotightly.
Consider.....
Installingchildprooftapcoversorchildresistanttaps(bothapproacheswillpreventasmallhandbeing
abletoturnonthetap).
Installing tempering valves or thermostatic mixing valves which reduce the hot water temperature delivered
tothetaps.Yourlocalplumbingauthoritymayalreadyrequirethatthesebetted.Contactyourinstaller
orlocalplumbingauthorityifindoubt.
Never….
Leave a toddler in the care of another child. They may not understand the need to have the water
temperature set at a safe level.
DANGER BEWARE OF
SCALDING HAZARDS
WARNINGS & SAFETY
Rinnai 6 HotoElectricStorageWaterHeaterOIM
SAFETY DEVICES
ForsafeoperationthiswaterheateristtedwithacombinationPressure&TemperatureReliefValve,athermostat
andanover-temperaturecutoutforeachheatingelement.
WARNING
DO NOT tamper with or remove safety devices.
DO NOToperatethiswaterheaterunlessallsafetydevicesarettedandinworkingorder.
Theoperationofthethermalcutoutindicatesapossiblydangeroussituation.DO NOT reset the
thermalcutoutuntilthewaterheaterhasbeenservicedbyaqualiedperson.
Pressure & Temperature Relief (PTR) Valve
Thisvalveislocatednearthetopofthewaterheaterandisessentialforsafeoperation.
WARNING
DO NOT sealorblocktheoutletofthePTRvalveoritsdrainpipe.
DO NOT replacethePTRvalvewithonethathasahigherpressureratingthanisspeciedfor
the water heater.
ThePTRvalveshouldbecheckedforperformanceorreplacedatintervalsnotexceeding5years,ormorefrequently
inareaswithahighincidenceofwaterdepositsbyaqualiedperson.Theeasinggearmustbeoperatedatleast
onceeverysixmonthsormorefrequentlyinareaswithahighincidenceofwaterdeposits.
WARNING
Failure to do this may result in the water heater cylinder failing or under certain circumstances,
exploding.Waterdischargedwillbeveryhot.Exercisecaretoavoidscaldinjury.Ifthevalvedoes
notsealagainwhentheeasinggearisclosed,contactRinnaitoarrangeinspectionbyaqualied
person.
Itisimportantyouraiseandlowertheeasinggeargently.Ifthevalvedoesnot
dischargewaterwhentheeasinggearleverislifted,theremaybeaserious
problemandthepowersupplyinthemeterbox(theswitchmarked‘Water
heateror‘hotwater’)ortheisolatingswitchinstallednearthewaterheater
mustbeswitchedoimmediately.ContactRinnaitoarrangeinspectionby
aqualiedperson.
ItisnormalforthePTRvalvetoreleaseasmallquantityofwaterthroughthedrainpipeduringheating.Ifthevalve
dribblesorleakscontinuously,tryeasingthevalvegearforafewseconds.Thismaydislodgeanyforeignmatter
andstopleakage.Ifleakagedoesnotstoptheremaybeaproblemasdetailedbelow:
Ifthereareheavyowsofwateruntilthewaterheateriscoldwhichthenstopsuntilthewaterreheatstheremay
beaseriousproblemandthepowersupplyinthemeterbox(theswitchmarked‘Waterheateror‘hotwater’)or
theisolatingswitchinstallednearthewaterheatermustbeswitchedoimmediately.ContactRinnaitoarrange
inspectionbyaqualiedperson.
Ifthereisasteadyowforlongperiods,oftenatnight,itmaybeasaresultofthewaterpressureexceedingthe
designpressureofthewaterheater.ContactyourinstallingplumberasaPressureLimitingValve(PLV)may
berequired.
Expansion Control Valve (ECV)
An ECV is recommended in all geographical areas where the water supply has a tendency to cause scaling,
includingSouthAustraliaandWesternAustralia.LocalregulatoryauthoritiesmayrequirethatanECVbetted.
TheECVistobesuppliedandttedbytheinstaller.RefertothesectionWaterQualityformoreinformationon
scalingwater.
IfanECVistted,operatetheeasinggearatleastonceeverysixmonthstoremoveanydepositsandtoverify
thatitisnotblocked.
TheECVshouldbecheckedforperformanceorreplacedatintervalsnotexceeding5years,ormorefrequentlyin
areaswithahighincidenceofwaterdepositsbyaqualiedperson.
ItisnormalanddesirablethattheECVallowsasmallquantityofwatertobedischargedthroughthedrainpipe
duringtheheatingcycle.Ifthevalvedribblesorleakscontinuously,operatetheeasinggearforafewseconds.This
maydislodgeanyforeignmatterandstopleakage.IfleakagedoesnotstopContactRinnaitoarrangeinspection
byaqualiedperson.
Gently lift lever
until water flows
from drain line,
lower lever gently
to close
WARNINGS & SAFETY
Rinnai 7 HotoElectricStorageWaterHeaterOIM
ANODE
Thewaterheater isttedwith asacricial anode toextend it’s life.Itwill slowlydissipatewhilst protectingthe
cylinder.Thelifeofthewaterheatermaybeextendedbyarrangingforanauthorisedpersontoinspecttheanode
andreplaceitifrequired.Itisrecommendedthattheanodebeinspectedatleastevery5years.Thefactorytted
RinnaianodeisMagnesiumbased.Thisanodeissuitablewhenthetotaldissolvedsolids(TDS)contentinthe
watersupplydoesnotexceed600mg/L,whichisthecaseinmostareas.Inareaswherethetotaldissolvedsolids
(TDS)contentinthewatersupplyexceeds600mg/LtheRinnaialuminiumbasedanodeisrequired.
WATER QUALITY
Thewaterqualityofmostpublicsuppliesissuitableforthewaterheatingsystem.Thewaterqualityfrombore
wellsis generally unsuitablefor thewater heating system.Refer tothe ‘Warranty Conditions’ forwater quality
parametersandhowtheyaectthewarrantyconditions.Ifindoubtaboutthewaterquality,haveitcheckedagainst
theparameterslistedinthewarrantyconditions.Ifsludgeorforeignmatterispresentinthewatersupply,asuitable
strainerltershouldbeincorporatedinthewatersupplytothesystem.
OPERATIONAL OVERVIEW (Howthehotwatersystemworks)
Single Element Model: A vitreous enamel lined steel cylinder stores water which is heated by a single
thermostaticallycontrolledheatingelement,locatedatthebaseofthecylinder.Thewaterheaterconnectsdirectly
tothemainswatersupply.TheheatingelementcanbeconnectedtoaContinuousorO-Peakelectricitysupply.
Thecontinuoussupplyisappropriatewhenthewaterheatercapacityislessthanthedailyusageofhotwater.The
O-Peaksupplyisappropriatewhenthewaterheatercapacityexceedsthedailyusageofhotwater.TheO-Peak
supplyallowsheatingonlyforsetperiodsandavolumeofwatersucientfordailyusageisheatedduringtheset
periodandstored.TheO-Peaksupplyisusuallycheaper.Electricitysupplytypesandtarisvaryaccordingtothe
localelectricityauthority.
Twin Element Model:Avitreousenamellinedsteelcylinderstoreswaterwhichisheatedbyatwinthermostatically
controlledheatingelements,oneelementislocatedatthebaseofthecylinder,whiletheotherislocatednearthe
top.Thewaterheaterconnectsdirectlytothemainswatersupply.Thebottomheatingelementheatsthewhole
contentsofcylinderandTopheatingelement(booster)onlyoperatesduringthehighdemandperiodstoheatthe
upperportionofthecontentsofthecylinder.Thetwoheatingelementsarewiredfornon-simultaneousoperation,
sothat onlyone heatingelement canoperate ata time.Thebottom heatingelement canbe connectedto an
O-Peakelectricitysupply,andthetopheatingelementtoacontinuouselectricitysupply.
Turning Water Heating System ‘OFF’
Ifthewaterheaterisnotgoingtobeusedforonlyafewdays,wesuggestyouleaveitswitchedon.Ifitisnecessary
toswitchothewaterheater,theswitchisusuallymarkedandlocatedintheelectricitymeterboxofthebuilding.
Turning Water Heating System ‘ON’
Switchontheelectricsupplytotheheatingelements.Theswitchisusuallymarkedandlocatedintheelectricity
meterboxofthebuilding.Waterheatingwillnowoccurasrequired.Itmaytakeanumberofhoursbeforehotwater
isavailable.
DRAINING
WARNING
DrainingMUST BE carriedoutbyaqualiedperson.
WatermaybeHOT during draining.
Drainthewaterheaterasfollows:
1. Isolateorturn‘OFF’thewaterheaterattheelectricitysupply.
2. Closethecoldwaterisolationvalveattheinlettothewaterheater.
3. Closeallhotwatertaps.
4. OperatethePTRvalveeasinggear-gently.OperatingthePTRvalveeasinggearwillrelievethepressure
inthewaterheater.
5. Undothecoldwaterinletunion.Attachahosetothewaterheatersideoftheunion.Lettheotherendofthe
hosegotoadrain.
6. OperatethePTRvalveeasinggearagain.Thisallowsairintothewaterheaterandwillresultinwaterdraining
throughthehose.
IMPORTANT INFORMATION
Rinnai 8 HotoElectricStorageWaterHeaterOIM
SAVE A SERVICE CALL
Checktheitemsbelowbeforerequestingaservice.Serviceandpartschargesmaybeincurredwhereitisfound
thatthereisnofaultwiththewaterheaterandtheissueisrelatedtotheplumbinginstallationorisduetothefailure
ofwaterorelectricsupplies.
Insucientornohotwater
Is the electricity supply
connected?
Checkthattheisolatingswitchmarked“HOTWATER”or“WATERHEATER”atthe
meterboxisswitchedon.Checkalsothatanyisolatingswitchesinstallednearthe
waterheaterareswitchedon.
Checkthefuse orcircuitbreakermarked “HOTWATER”or“WATERHEATER” at
themeterbox.Repeatedfailureoffuseortrippingofcircuitbreakerindicatesafault
whichmustbeinvestigatedbyanauthorisedtradesperson.
IsyourunitaTwinElement
electricwaterheater?
Atwinelementmodel(non-simultaneous)musthaveacontinuouselectricitysupply
tothetopheatingelement.Checkthatthisisthecase.
Are you using more hot
waterthanyouthink?
Oftenitisnotrealizedhowmuchhotwaterisactuallyused.Thisappliesespecially
toshowering.Reviewhotwaterusage,especiallythetimetakenforshowering,and
investigatetheuseofowcontrolvalvesorWatersavingshowerroses.
Are water heater valves
dischargingexcessively?
Refertothesection“SafetyDevices”onpage6.
Thermostatsettings? Checkthetemperatureofhotwaterdeliveredwithathermometerplacedunderthe
closestoutlet(usuallythekitchensink)onanon-temperedhotwaterline.
This test should be done early in the morning after overnight electrical boosting
beforeanyhotwaterisused.Thetemperatureofthewaterdeliveredshouldbeat
least55°C(allowingforheatlossesinpipework).
If this is not the case, the temperature may need to be increased. Contact your
installerorRinnaitodiscussadjustingthethermostat.
Nowaterfromthehottap? Restrictioninthehottaporfailureofthecoldwatersupplytotheheater.
Checkforwaterowattheotherhottapsandthatthecoldwaterisolationvalveis
fullyopen.
HighElectricityBills
Ifyouthinkyourelectricity
bill is too high, check for
thesepossibilities.
If, after investigating, and
you still require assistance
contact Rinnai.
Youmaybeusingmorehotwaterthanyouthink.Thisappliesespeciallytoshowering.
Reviewhotwaterusage,especiallythetimetakenforshowering,andinvestigatethe
useofowcontrolvalvesor‘watersaving’showerroses.Investigaterecentchanges
tohotwaterusagepatterns.
Water heatervalves maybe dischargingexcessively. Refer tothe section“Safety
Devices”onpage6.
Theremaybehotwaterleakagesinhotwaterpipesortaps.Havethesecheckedand
rectiedbyaplumber.
Theremayhavebeenchangesinelectricitytarissinceyourlastbill.
PERIODIC MAINTENANCE & SERVICING
Ifoverowtrayanddrainaretted,itistheusersresponsibilitytohavethesecheckedperiodicallytoensurethere
arenoblockages.
TheusershouldoperatetheeasinggearoftheECVandPTRvalve(iftted)every6monthsasdescribedunder
“SafetyDevices”onpage6.
Rinnaiservicenetworkpersonnelarefullytrainedandequipped.IfyourRinnaiappliancerequiresservicingcontact
Rinnaiasperthedetailsonthebackpageofthismanual.Rinnairecommendsthatthiscommercialappliancebe
inspectedandservicedbyaqualiedpersonevery12months.
TheECVandPTRvalveMUSTBEcheckedforperformanceorreplacedbyaqualiedpersonatintervalsnot
exceeding5yearsormorefrequentlyinareaswherethewaterisclassiedasscalingwater.Refertoboththe
“Anode”and“WaterQuality”onpage7forAnodeselection,inspectionandmaintenancerequirements).
Iftheelectricsupplyconduittothewaterheaterisdamaged,itMUSTBEreplacedbyaqualiedpersoninorder
toavoidahazard.
CARE & MAINTENANCE
Rinnai 9 HotoElectricStorageWaterHeaterOIM
APPLIANCE COMPONENTS
1. DataandWarningLabels
2. Leftcoldwaterinlet
Connection RP 3/4" (20mm)
3. Element+ThermostatCover–Electricalsupplyconnection*
Removal & connection by qualied persons only, in accordance with AS/NZS 3000
4. PTRvalvedrainpipe(SuppliedbyInstaller)
Copper only drain in accordance with AS/NZS 3500.4
5. Element+ThermostatCover (Twinelementmodelsonly)*
Removal by qualied persons only
6. Lefthotwateroutlet
Connection RP 3/4" (20mm), use a union connection and insulate hot water pipe
7. PTRvalveconnection
RP 3/4" (20mm), use supplied PTR Valve with 1/2" Reducing Bush
8. Anodecap
9. DuplicatePTRvalveconnection(25and50litremodelsonly)
10. Duplicatehotwateroutlet
11. DuplicatePTRvalvedrainpipe(SuppliedbyInstaller)
12. Duplicatecoldwaterinlet
13. Waterheatersupport
In accordance with AS/NZS 3500.4
14. SafeTray&drain(NotSupplied)
May be required to avoid property damage in accordance with AS/NZS 3500.4
NOTE
*RemovalandconnectionbyqualiedpersonsONLY,inaccordancewithAS/NZS3000
ValveswithpressureratingsotherthanspeciedareunsuitableandMUST NOTbeused.
WATER HEATER - located closest to most frequently used outlet - Access for service in the
installed position.
2
1
3
5
4
6
7 8
12
13
10
9
14
11
SPECIFICATIONS
Rinnai 10 HotoElectricStorageWaterHeaterOIM
TABLE 1. DIMENSIONS & WEIGHT
FE
INLETS
A
D
B
C
OUTLETS
P&TR
G
Plumbing connections are duplicated
(Dual Handed) on each side.
Models Hoto
25L
Hoto
50L
Hoto
80L
Hoto
125L
Hoto
160L
Hoto
160L-D
Hoto
250L
Hoto
315L
Hoto
400L
Hoto
160L Twin
Element
Hoto
250L Twin
Element
Hoto
315L Twin
Element
Hoto
400L Twin
Element
A452 694 900 1245 1620 1313 1477 1770 1840 1620 1477 1770 1840
B490 490 590 590 564 600 674 674 744 564 674 674 744
C415 415 515 515 500 537 605 605 675 500 605 605 675
D297 524 683 1020 1419 1107 1248 1541 1587 1419 1248 1541 1587
E153 158 225 225 162 186 210 210 237 162 210 210 237
F80 80 155 155 87 110 135 135 163 87 135 135 163
G- - - - - - - - - 1039 985 1225 1263
All dimensions are in mm unless otherwise stated
SPECIFICATIONS
Rinnai 11 HotoElectricStorageWaterHeaterOIM
TABLE 2. RATINGS & OTHER SPECIFICATIONS
NOTE
APLVMUSTBEFITTEDIFTHEMAINSPRESSUREEXCEEDSTHELIMITSSHOWN.IFTHEMAINS
PRESSUREISWITHINTHELIMITSSHOWNFITMENTOFTHEPLVISOPTIONAL,HOWEVER,IT
ISRECOMMENDEDTHATTHEPLVISFITTEDINALLINSTALLATIONSASITAIDSWATERAND
ENERGYCONSERVATION.
Hoto
25L
Hoto
50L
Hoto
80L
Hoto
125L
Hoto
160L
Hoto
250L
Hoto
315L
Hoto
400L
Hoto 160L
Compact
Model Code HFE EHFA EHFD
Storage Capacity (L) 33 55 84 140 172 279 334 420 170
Hot Water Delivery (L) 25 50 80 125 160 250 315 400 160
Element Size (kW) 1.8, 2.4,
3.6
1.8, 2.4,
3.6
1.8, 2.4,
3.6
1.8, 2.4,
3.6
1.8, 2.4,
3.6
2.4, 3.6,
4.8
2.4, 3.6,
4.8 3.6, 4.8 2.4,3.6
Total Height (mm) A 452 694 900 1245 1620 1477 1770 1840 1313
Width incl. PTR Valve (mm) 490 490 590 590 564 674 674 744 600
Diameter (mm) B 415 415 515 515 500 605 605 675 537
Outlet Height (mm) C 297 524 685 1020 1419 1248 1541 1587 1107
Inlet Height (mm) D 153 158 225 225 162 210 210 237 186
Electrical Entry -
Lower (mm) E 80 80 155 155 87 135 135 163 110
Electrical Entry -
Upper (mm) F N/A N/A N/A N/A 1039 985 1225 1263 N/A
Packaged Weight (kg) 23 29 48 60 60 70 82 96 56
Boost Capacity
(Twin element only) (L) N/A N/A N/A N/A 40 49 60 81 N/A
PTR Valve - included (kPa) 1000
ECV (kPa) 850
Max. Inlet Pressure
with ECV (kPa) 680
PLV with ECV (kPa) 500
Max. Inlet Pressure
without ECV (kPa) 800
PLV without ECV (kPa) 500
Max. Thermostat Setting
(°C) 70°C
Ingress Protection Rating IPX4
Electrical Supply 240V-@50Hz
Tank Body Colour White Dune
Hot and cold water
connection Rp 3/4 (20mm)
SPECIFICATIONS
Rinnai 12 HotoElectricStorageWaterHeaterOIM
HOT WATER PLUMBING SYSTEM EXAMPLE - NO TLD
*PTR VALVE
(Supplied)
KITCHEN
LAUNDRY
NON TEMPERED SUPPLY
BATHROOM
ENSUITE
TO DRAIN
COLD
SUPPLY
Isolating
Valve
*ECV
TO DRAIN
Non-return
Valve
*PLV
WATER
HEATER
(Not Supplied)
CAUTION
ValveswithpressureratingsotherthanspeciedareunsuitableandMUST NOT beused.
*Forratingssee"Table2.Ratings&OtherSpecications"onpage11.
HOT WATER PLUMBING SYSTEM EXAMPLE - WITH TLD
KITCHEN
LAUNDRY
ENSUITE
BATHROOM
TEMPERED
SUPPLY Temperature
Limiting Device
(TLD)
COLD
SUPPLY
Non-return
Valve
*PLV
Isolating
Valve
Isolating
Valve
*PLV
*ECV
(OR)
WATER
HEATER
Non-return Valve
COLD
SUPPLY
Non-return
Valve
Non-return
Valve
WATER
HEATER
Temperature
Limiting Device
(TLD)
Non-return
Valve
*PTR VALVE
(Supplied)
TO DRAIN
*ECV
TO DRAIN
TO DRAIN (Not Supplied)
TEMPERED
SUPPLY
*PLV
NON TEMPERED SUPPLY
NON TEMPERED SUPPLY
Isolating
Valve
Non-return
Valve
CAUTION
ValveswithpressureratingsotherthanspeciedareunsuitableandMUST NOT beused.
*Forratingssee"Table2.Ratings&OtherSpecications"onpage11.
ItmaybearequirementthatthehotandcoldwatersupplypressurestoaTemperatureLimitingDevice(TLD)are
equal.Ifthisisthecase,aPLVwiththesamepressureratingasthePLVforthehotwaterisrequiredfortheTLD
asshown.
INSTALLATION METHODS
Rinnai 13 HotoElectricStorageWaterHeaterOIM
HOT WATER PLUMBING SYSTEM EXAMPLE / FLOW & RETURN PIPE WORK - NO TLD
COLD
SUPPLY
Isolating
Valve
*ECV
TO DRAIN
Non-return
Valve
*PLV
KITCHEN
LAUNDRY
NON TEMPERED SUPPLY
BATHROOM
ENSUITE
*PTR VALVE
(Supplied)
TO DRAIN
WATER
HEATER
(Not Supplied)
Non-return
Valve
Isolating
Valve
Isolating
Valve
Flow & Return
Pump
CAUTION
ValveswithpressureratingsotherthanspeciedareunsuitableandMUST NOT beused.
*Forratingssee"Table2.Ratings&OtherSpecications"onpage11.
HOT WATER PLUMBING SYSTEM EXAMPLE / FLOW & RETURN PIPE WORK - WITH TLD
COLD
SUPPLY
Isolating
Valve
*ECV
TO DRAIN
Non-return
Valve
*PLV
KITCHEN
LAUNDRY
NON TEMPERED SUPPLY
BATHROOM
ENSUITE
TO DRAIN
*PTR VALVE
(Supplied)
WATER
HEATER
(Not Supplied)
Non-return
Valve
Non-return
Valve
Non-return
Valve
Isolating
Valve
Isolating
Valve
Flow & Return
Pump
Temperature
Limiting Device
(TLD)
CAUTION
ValveswithpressureratingsotherthanspeciedareunsuitableandMUST NOT beused.
*Forratingssee"Table2.Ratings&OtherSpecications"onpage11.
1. Thisschematicisanexampleonly,variationsmayalsobesuitable.
2. TemperedwaterfromaTLDCANNOTbere-circulated.TheTLDMUST BE positioned in
adeadleg,branchingothecirculatedhotwaterowandreturnpipe.
INSTALLATION
Rinnai 14 HotoElectricStorageWaterHeaterOIM
ThisapplianceMUSTBEinstalledbyaqualiedpersoninaccordancewith:
Manufacturersinstallationinstructions
CurrentAS/NZS3000WiringRules
CurrentAS/NZS3500.4PlumbingandDrainage-HeatedWaterServices
Alllocalregulatoryrequirements
ThisapplianceisNOTsuitableforuseasaspaorswimmingpoolheater.
LOCATION
TheRinnaiHotoelectricstoragewaterheaterrangehaveaningressprotectionratingofIPX4making80Lto
400Lmodelssuitableforinternalorexternalinstallation.However,Hoto25Land50Lmodelscanonlybeinstalled
indoors.
Thewaterheatershouldbeplacedascloseaspracticabletothemostfrequentlyusedhotwateroutletpointor
pointstominimizethedelaytimeforhotwaterdelivery.Thiswillusuallybethekitchentap.Forinstallationswhere
thedistancebetweenthewaterheaterandtheoutletsisconsiderable,aowandreturnsystemcanbeusedwhich
willminimizethewaitingtimeforhotwaterdelivery.
Itisrecommendedthatthewaterheaterisinstalledatgroundoroorlevel.ItMUSTBEinstalledinavertically
uprightposition.ThewaterheaterMUSTBEaccessiblewithouttheuseofaladderorscaold.Installationintoroof
spacesMUSTcomplywithlocalregulatoryauthorityrequirements.
EnsurethePTRvalve,isolatingvalves,accesscovers,thermostatsandheatingelementshavesucientclearances
andareaccessibleforserviceandremoval.TheinformationontheratingplatesMUSTalsobereadable.
The water heater MUST BE installed in free standing mode on a level and stable base in a manner that is
acceptabletolocalauthorities.Avoidsituationsthatmayresultinpoolingofwateraroundthebaseofthewater
heater.
Wherepropertydamagecanoccurasaresultofwaterleakageinanindoorinstallation,thewaterheaterMUST
BEinstalledwithasafetray(overowtray)anddrain.Construction,installationanddrainingofthesafetrayMUST
complywithlocalregulatoryrequirementsand.AS/NZS3500.4alsorequirestheuseofasafetrayforparticular
situations.
WATER QUALITY
Thewaterqualityofmostpublicsuppliesissuitableforthewaterheater.Waterqualityfromborewellsisgenerally
unsuitable.Refertothe‘WarrantyConditions’forwaterqualityparametersandhowtheyaectwarranty.Ifindoubt
aboutwaterquality,haveitcheckedagainsttheparameterslistedinthewarrantyconditions.
Ifsludgeorforeignmatterispresentinthewatersupply,asuitablestrainerorltershouldbeincorporatedinthe
watersupplytothewaterheater.
Scalingwaterisdenedashavingatotalhardnessinexcessof200mg/litre(expressedascalciumcarbonate)or
aSaturationIndexinexcessof+0.4.AreasthathaveascalingwatersupplyincludeSouthAustraliaandWestern
Australia.Inascalingwatersupply,calciumcarbonateandpossiblyothercompoundsaredepositedoutofthe
waterontoanyhotmetallicsurfacesandformascale.
InareasofscalingwateranECVMUSTBEttedonthecoldwaterlinebetweenthenon-returnvalveandthe
connectiontothewaterheatertoprotectthePTRvalveandthewaterheater.Localregulatoryauthoritiesmay
requirethatanECVbetted.TheECVistobesuppliedandttedbytheinstaller.
MAINS PRESSURE
TheHotoelectricstoragewaterheaterrangeutilisemainspressurebyconnectingdirectlytothemainswater
supply.IfthemainswatersupplypressureinyourareaexceedstheratedpressureofthewaterheateraPLV
MUSTBEtted.
Themainswatersupplypressureshouldbegreaterthan350kPafortruemainspressureoperationalperformance
tobeachieved.
INSTALLATION
Rinnai 15 HotoElectricStorageWaterHeaterOIM
THERMOSTAT SETTING
Thethermostatsettingcanbeadjustedbetween60°Cand70°C.Ithasbeenfactorypre-setto70°C.
WARNING
Thisappliancemaydeliverwaterathightemperature.RefertothePlumbingCodeofAustralia
(PCA), local requirements and installation instructions to determine if additional delivery
temperature control is required.
WARNING
ThethermostatsettingsMUST ONLYbeadjustedbyaqualiedperson.
REDUCING THE RISK OF SCALDING
Thiswaterheatercandeliverwaterattemperatureswhichcancausescalding.Children,disabledandtheelderly
areatthehighestriskorbeingscalded.
Local regulatory requirements and the requirements of AS/NZS 3500.4 MUST BE considered regarding
temperaturelimitationsofhotwater deliveredtoareasusedprimarilyfor personalhygienesuchasbathrooms
andensuites.Thedeliverytemperaturemaybelimitedto45°Cforearlychildhoodcentres,primaryandsecondary
schoolsandnursinghomesorsimilarfacilitiesfortheyoung,aged,sickorpeoplewithdisabilitiesand50°Cforall
otherbuildings.ThesetemperatureswillreducetheriskofscaldinjuryandcanbeachievedbytheuseofaTLD,
forexampleathermostaticmixingvalveortemperingvalve.
RinnairecommendthatanapprovedTLDisttedintothehotwaterpipeworkfromthewaterheatertoareasused
primarilyforpersonalhygienesuchasbathroomsandensuitestoreducetheriskofscalding.
Refertotheinstallationcongurations"HotWaterPlumbingSystemExample-WithTLD"onpage12and"Hot
WaterPlumbingSystemExample/Flow&ReturnPipeWork-WithTLD"onpage13.
PLUMBING CONNECTIONS
Connections to the water heater
RefertoSpecicationsfortheplumbingconnectionsizesandlocation(Table1)andthespeciedpressureratings
ofvalves(Table2).Referalsotothediagramsunder“InstallationCongurations”.
WARNING
ValveswithpressureratingsotherthanspeciedMUST NOTbeused.
Anisolationvalveandnon-returnvalveMUSTBEttedinthecoldwatersupplytothewaterheatersothewater
heatercanbeisolated.Combinationisolationandnon-returnvalvesuchas'Duo'or'Trio'valvesaresuitablefor
thispurpose.
IsolationvalvesMUSTNOTbetteddirectlytotheappliance.Usedisconnectionunionsbetweenthewaterheater
andthevalvestoallowthewaterheatertobedisconnectedfrompipeworkatalaterdate.
Purgepipework toremove swarfand otherforeign matterbeforenal connectionto thewater heaterto avoid
damagetothewaterheater.
IfolivecompressionttingsareusedforconnectionstheolivesMUSTBEmetallicsuchasbrassorcopper.Only
approvedthreadsealingtapeorsealantshouldbeused.
Water Pipes
Pipesizingshouldbecarriedoutbypersonscompetenttodosoforeachindividualinstallationinaccordancewith
localregulatoryrequirementsandtakeintoconsiderationthespecicationsofthewaterheater.
ThecoldsupplypipetoandhotwaterpipefromthewaterheaterMUSTBEinsulatedinaccordancewithlocal
regulatoryrequirementsandAS/NZS3500.4tooptimiseperformanceandenergyeciency.InsulationMUSTBE
weatherproofandUVresistantifexposed.
Thehotwaterpipefromtheoutletofthewaterheatershouldalsobeconguredintheshapeofa“heattrap”toaid
energyeciencyinaccordancewithlocalregulatoryrequirementsandAS/NZS3500.4.
Topreventdamagetothewaterheaterwhenattachingpipeclipsorsaddlestothejacket,itisrecommendedthat
selfdrillingscrewswithamaximumlengthof12mm areused.Ifdrillingisrequiredtakeextremecare NOT to
penetratetheinnercylinder.DamagetotheinnercylinderisNOTcoveredunderwarranty.
INSTALLATION
Rinnai 16 HotoElectricStorageWaterHeaterOIM
Pressure and Temperature Relief (PTR) Valve
AcombinationPTRvalveissuppliedwiththewaterheater.ItisanimportantsafetydeviceandMUSTBEttedin
allinstallationsbeforethewaterheaterisoperated.
DONOTusethevalveifthesensingprobehasbeenbentoritisdamagedinsomeotherway.
ThePTRvalveistobescrewedtotheconnectionmarked“PTRValve”atthetopofthewaterheater.
ThethreadMUSTBEsealedwithanapprovedsealingtape.MakesurethesealingtapedoesNOThangover
theendofthethreadofthevalveasthismayblockthewaterwayandpreventthevalvefromoperatingproperly.
ToscrewthevalveintothewaterheaterconnectionuseawrenchonthespanneratsandNOTthevalvebody.
Leavethevalveoutletpointingdownwards.AcopperdrainpipeMUSTBEttedtothevalveoutletinaccordance
withthesection"ReliefValveDrainLines"onthebottomofpage16.
The valve body MUSTBE insulated in accordance with local regulatory requirements andAS/NZS 3500.4 to
optimiseperformanceandenergyeciency.InsulationMUSTBEappliedinamannerthatensuresitdoesNOT
interferewiththeoperationofthevalve.InsulationmaterialMUSTBEweatherproofandUVresistantifexposed.
Expansion Control Valve (ECV)
InareasofscalingwateranECVMUSTBEttedonthecoldwaterlinebetweenthenon-returnvalveandthe
connectiontothewaterheatertoprotectthePTRvalveandthewaterheater,asperthediagramsunder“Installation
Congurations”.ItMUSTBEthelastvalveonthecoldinletbeforethewaterheater.
LocalregulatoryauthoritiesmayrequirethatanECVbetted.TheECVistobesuppliedandttedbytheinstaller.
RefertothesectionWaterQualityformoreinformationonscalingwater.
AcopperdrainpipeMUSTBEttedtothevalveoutletinaccordancewiththesection"ReliefValveDrainLines"
onthebottomofpage16.
The valve body MUSTBEinsulated in accordance with local regulatory requirements andAS/NZS 3500.4 to
optimiseperformanceandenergyeciency.InsulationMUSTBEappliedinamannerthatensuresitdoesNOT
interferewiththeoperationofthevalve.InsulationmaterialMUSTBEweatherproofandUVresistantifexposed.
Pressure Limiting Valve (PLV)
APLVistobettedifthesupplypressureexceedsthelimitsshowninTable2“Ratings&OtherSpecications"
onpage11asperthediagramsunder“InstallationCongurations”.ThePLVistobesuppliedandttedbythe
installer.
Relief Valve Drain Lines
CopperdrainlinesofsizeDN15MUSTBEttedtotheECV(iftted)andthePTRvalve.Usedisconnectionunions
toconnectdrainlinestothevalves.
ThecongurationofdrainlinesMUSTBEinaccordancewithlocalregulatoryrequirementsandtherequirements
ofAS/NZS3500.4.
Thelengthshouldbeasshortaspossibleonacontinuousdownwardslopewithnorestrictions.Lengthshould
NOTexceed9metreswithnomorethanthree45°bends.Ifadrainlinedischargesintoatundish,thedrainline
fromthetundishMUSTNOTbelessthanDN20.ThedrainlinefromatundishMUSTmeetthesamerequirements
asdrainlinesfromreliefvalves.
Thedrain linesfrom thePTR valveand ECV(if tted)from an individualwater heatermay beinterconnected
subjecttolocalregulatoryauthorityrequirementsandAS/NZS3500.4.TheterminationpointMUSTalsocomply
withlocalregulatoryrequirementsandAS/NZS3500.4.DrainlinesMUSTNOTdischargeintoasafetray.
TheoutletofdrainlinesMUSTNOTbeobstructedandbepositionedsothattheyarereadilydiscerniblebutNOT
causeinjury,damageornuisance.
Inareaswherewaterpipesarepronetofreezing,drainlines MUSTBEinsulatedandNOTexceed300mmin
length.InthiscasethedrainlineMUSTdischargeintoatundishthroughanairgapofbetween75mmand150mm.
INSTALLATION
Rinnai 17 HotoElectricStorageWaterHeaterOIM
ELECTRICAL SUPPLY
WARNING
Mustbeinstalled,maintainedandremovedbyauthorisedpersonsinaccordancewithAS/NZS
3000 and all other relevant local regulations and municipal building codes including OH&S
requirements.
Ensureelectricwiringisinstalledproperly.Improperinstallationmaycausemalfunction,re,or
electric shock.
Theunitmustbeearthedfollowinglocalelectricalcodes.
AwaterheaterNOTttedwithapowercord&plugMUSThavetheheatingelementconnectedtoanindependent,
fused,AC240V50Hzpowersupplywithanisolatingswitchinstalledattheswitchboard,whichshalleectively
isolateallactivesupplyconductorsfromthecircuitandmeansfordisconnectionmustbeincorporatedinthexed
wiringinaccordancewiththewiringrules.
Ensurethepremiseswiringtothesystemiscapableofwithstandingthesystemelectricalload(refertoSpecications
-Table1forelectricalloaddetails).
ThepowersupplytoasingleelementmodelcanbeO-Peak(overnight),ExtendedO-Peak(overnightandday),
orContinuous(day).
The power supply to a twin element model should be O-Peak (overnight) to bottom heating element and
Continuoustothetopheatingelement.
Checktheavailabletariswiththelocalelectricitysupplier.TheO-Peak(overnight)isusuallythemosteconomical
forthecustomer.
Electrical Connections
WARNING
ThewaterheaterMUST BElledwithwaterpriortoconnectiontothepowersupply.
WARNING
ElectricalconnectionMUST BEcarriedoutbyaqualiedpersonandinaccordancewithAS/NZS
3000 'Wiring Rules' and local authority requirements
Disconnect all power prior to installation and commissioning. This appliance is designed for
singlephase240Volts,ACmainselectricaloperation.
All electrical connections MUST BEmadebyanauthorisedpersonandmustcomplywithall
localelectricalsupplyregulationsandAS/NZS3000.
NOTE
Thepremiseswiringtotheheatermustbecapableofwithstandingtheapplianceload.
Electricalaccessisviaa20mmholebeneaththeelementcoverformountingwithanapprovedweatherproof
electricalconduitnipple.Forentrytotheelementcoverremovethetwoxingscrews.
ConnectallACTIVEandNEUTRALwiresinaccordancewiththewiringdiagramwhichisalsoincludedattherear
oftheelementaccesscover.EnsuretheincomingEARTHwireissecurelyxedtotheearthpostprovidedonthe
heatercase.Inspectandensurethatallwiringlinksaresecurepriortoxingtheaccesscoverandturningthe
POWERON.
ToensuretheOver-temperatureandEnergyCut-outisset,pressthe(red)'reset'buttonontheThermostat.
Isolate all
sources of supply
prior to servicing
INSTALLATION
Rinnai 18 HotoElectricStorageWaterHeaterOIM
Wiring Diagrams
Thermostat Setting
The thermostat is adjustable from 60°C to 70°C. Turning the adjustment knob anticlockwise decreases the
temperaturesettingandturningitclockwiseincreasesthetemperaturesetting.Thewaterheaterasdeliveredwill
havethethermostatpresetto70°C.
WARNING
EnsurethepowersupplyisswitchedOFFbeforeremovingtheaccesscovertotheelementand
thermostat.
TheaccesscovertotheelementandthermostatMUST ONLY BEremovedbyanElectricianor
othersuitablyqualiedtradesperson.
ThethermostatsettingMUST ONLY BEadjustedbyanelectricianorothersuitablyqualied
trades person.
Afteradjustment,pressthe(red)‘Reset’Buttononthethermostatstoensuretheover-temperature
andenergycut-outisset.
Continuous - A
Off Peak - A
Neutral - N
Earth
BOTTOM ELEMENT
TWIN ELEMENTSINGLE ELEMENT
TOP ELEMENT
3 1
4
5 2
RESET
3 1
4
5 2
Active - A
Neutral - N
Earth
RESET
3 1
4
5 2
RESET
ST1204113 ST2207233
ST1204113
COMMISSIONING
Rinnai 19 HotoElectricStorageWaterHeaterOIM
WARNING
Commissioning activities MUST BEcarriedoutbyanauthorisedperson.
DO NOTswitchontheelectricpowersupplyuntilthewaterheaterislledcompletelywithwater.
TO FILL & TURN ‘ON’ THE WATER HEATER
1. Openallhotwatertapsinthebuilding,includingtheshower.
2. Openthecoldwaterisolationvalvetowaterheater.Airwillnowbeforcedoutofthetaps.
3. Closeeachtapwhenwaterrunsfreelywithoutairbubbles.
4. Checkallplumbingconnectionsandpipeworkforwaterleaks.
5. Connectthewaterheatertotheelectricitysupply,andturntheelectricpowersupply'ON'.
TO TURN ‘OFF’ THE WATER HEATER
Itmaybenecessarytoturnoawaterheaterafterinstallationandcommissioning,forexampleduringbuilding
activitiesorifthepremisesarevacant.
1. Isolateorturn'OFF'thewaterheaterattheelectricitysupply.
2. Closethecoldwaterisolationvalveattheinlettothewaterheater.
COMMISSIONING
S110801 20 HotoSeriesElectricStorageWH(NATIONAL)OIMIssuei-8/09/21
CONTACTS
Rinnai Australia Pty Ltd
ABN 74 005 138 769 | AU45204
100 Atlantic Drive, Keysborough, Victoria 3173
P.O. Box 460, Braeside, Victoria 3195
Tel: (03) 9271 6625
Fax: (03) 9271 6622
National Help Line
Tel: 1300 555 545* Fax: 1300 555 655
Monday to Friday, 8.00 am to 5.00 pm EST.
After Hours Hot Water Service Line
Tel: 1800 000 340*
*Cost of a local call higher from mobile or public phones.
For further information visit www.rinnai.com.au
or email enquiry@rinnai.com.au
Rinnai has a Service and Spare Parts network with
personnel who are fully trained and equipped to give
the best service on your Rinnai appliance. If your
appliance requires service, please call our National
Help Line. Rinnai recommends that this appliance be
serviced every year.
With our policy of continuous improvement, we
reserve the right to change, or discontinue at any time,
specifications or designs without notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Rinnai EHFA400S48 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI