EXIP 414/E 20510103
SAT>IP server
Characteristics
Supports SAT>IP protocol
Conforms to SAT>IP standard as per
EN 50585
Streams DVB-S-/S2 (HDTV) signals in
an IP data stream
Can be fed into different network types:
LAN (also K-LAN, Powerline ...), WLAN
integration via router, e.g. FRITZ!Box
Four independent tuners, each for one
data stream
Web interface for conguration,
administration and import
of software updates
Status display via LED
Can be congured for different clients
1)
:
Tablet PCs, smartphones, notebooks,
SAT>IP- capable receivers (z. B. UFS
924)
On/off switch
Can be operated on different types of
LNBs, multi-switches and single-cable
multi-switches
Supports standard switching signals:
14/18 V, 22 kHz, DiSEqC™1.0,
single-cable as per EN 50494
Four Sat inputs; one Ethernet-
RJ 45 connection
For horizontal installation
(e.g. like receivers) or on-wall installati-
on with the supplied mounting bracket
For indoor installation
High-efciency plug-in power supply
for voltage supply
Cable shoe for earthing connection
Support for wall mounting
Instruction sheet
1)
Provided the required software/apps are installed on the device
Delivery scope
Vous trouverez la
version française du
document sur:
Una versione italiana
di questo documen-
to è reperibile su:
Encontrará la version
española de este docu-
mento en la página:
www.kathrein.com
(Certied by SES ASTRA)
2 / 9
The equipment described is designed solely for the installation of satellite
receiver systems. Any other use, or failure to comply with these instructions,
will result in voiding of warranty cover.
The equipment may only be installed in dry areas indoors. Do not install on
or against highly combustible materials.
The power supply unit is only authorised for on-wall
mounting!
The equipment must be provided with an earthing wire
(Cu, at least 4 mm
2
).
Unused F-type connectors must be terminated with an EMK 05 (voltage-
separated).
The safety regulations set out in the current EN 60728-11 and EN 60065
standards must be complied with.
Connectors for coaxial cable: RF plugs 75Ω (series F) to
EN 61169-24.
Electrically live unit
Do not open the unit or tamper with it!
When working on the system always unplug the mains plug from the wall
socket!
There must be free circulation of air to dissipate the heat from the unit. Risk
of overheating! Clearance all round must be at least 5 cm!
Ambient temperature range: 0 to +40°C
Important:
Do not place liquid-lled items on top of the device or power supply unit.
The device or power supply unit must not be exposed to dripping or splash-
ing water.
The mains plug must be easily accessible and operable.
The only reliable method of disconnecting the unit from the mains is to un-
plug it.
Installation and safety instructions
An inner cable conduc-An inner cable conduc-
tor diameter greater than
1.2 mm, or the presence
of burrs may damage the
product inputs/outputs be-
yond repair
Max. 2 mm
excess
length
Clamping torque
max. 3.4 Nm (danger
of overwinding)
Diameter
0.6-1.2 mm
free of burrs
3 / 9
Wall mounting
For wall mounting only use the sup-For wall mounting only use the sup-
plied bracket (screws are not in-
cluded in the delivery scope)
Mount wall support with two screws
(Ø 4 mm, head diameter > 7 mm)
Screw on/attach all cables
Insert the device from above with feet
pointing down into the wall support
Table mounting (no fastening required)
A B
(Note on mounting position A: to prevent the
device from being pushed out of the sup-
port, the device should be held during sub-
sequent cable installation work)
4 / 9
On upper part of the housing:
1. Stream LED
2. Power LED
Rear panel:
3. RF1 input V low in Quatro mode;
single-cable (EN 50494) connection
4. RF2 input V high in Quatro mode
5. RF3 input H low in Quatro mode
6. RF4 input H high in Quatro mode
7. 10/100/1000 MBit Ethernet
8. Reset button
9. On/off switch
10. Power supply connection (12 V/3 A)
Rear panel
Start-up
Proceed as follows for start-up of the EXIP 414:
1. Connection of RF inputs:
On a Quad LNB or multi-switch: You can connect the four input cables as desired. The
device is precongured for this.
On a Quatro LNB, splitter or tap:
You must connect the four input cables correctly according to the voltage assignment (Tab
2). On the Web interface, “Quatro” must be set under “LNB settings”.
On a single-cable multi-switch/single-cable LNB:
Only the RF1 connection must be connected to a multi-switch or LNB. On the Web inter-Only the RF1 connection must be connected to a multi-switch or LNB. On the Web inter-
face, “OneCable” and the available UB slots must be selected under LNB settings.
1
2
3 4 5 6 7 8
9 10
5 / 9
Overview LED
Tab 1 LED ... Status EXIP 414
“Power” LED
Lit green Operation
Off No voltage supply
“Stream” LED
Lit blue Network connection generated
Flashes blue Active streaming (data transfer)
Off Network not connected
RF connections
Tab 2
Single-cable (EN 50494)
Quatro Quad/DiSEqC™
RF1 (950-2,150 MHz) 14/18 V; 0/22 kHz 14 V; 0 kHz 14/18 V; 0/22 kHz
RF2 (950-2,150 MHz) 14 V; 22 kHz 14/18 V; 0/22 kHz
RF3 (950-2,150 MHz) 18 V; 0 kHz 14/18 V; 0/22 kHz
RF4 (950-2,150 MHz) 18 V; 22 kHz 14/18 V; 0/22 kHz
2
. Network connection:
The LAN connection must be connected to the home network. Normal-
ly, the existing router (e.g. FRITZ!Box) will automatically assign an IP address.
On the Web interface, “Automatic” (default) will be set under “IP settings”.
3. “DC” connection:
Finally, the power supply is to be connected to the server rst and then to the network volt-
age.
Use Specication
Ethernet Connection to the network 10/100/1,000 MBit
DC socket Connection of power supply unit 12 V/3 A
If switch/button is ... the following occurs ...
Reset held down for about
5 seconds
Reset to factory
setting
On/Off pressed Device is cut off from voltage
supply
Additional connections
Switch and button
6 / 9
“Automatic” is set in the basic settings. This means that when the server is connected to a
router it is automatically allocated a new IP adress.
The respective client (PC, App oder IP-Receiver) detects the server via UPnP and a connec-
tion can then be established.
The satellite basic setting is “Quad/DiSEqC™”. Each RF port emits a DiSEqC™ or analogue
switch signal to switch the respective LNB or the multi-switch connection to the required
band.
Additional settings can be made in the web interface of the EXIP 414. You enter
in your web browser, enter the IP address of the EXIP 414, followed by the port 9527,
e. g. 192.168.175.35:9527. The IP address of your EXIP 414 can be found in your router
menu. Alternatively, the IP address can be determined with a software utility such as “Intel ®
Tools for UPnP Technology”.
The Web interface is accessed after entering the password “exip”.
You will nd more detailed instructions for the Web interface on “www.kathrein.de”.
Basic settings (Web interface)
The data stream is fed by the EXIP 414 in
your home network and can be played by
virtually any IP-enabled device
As well as SAT>IP-capable receivers
from our line e.g. the UFS 924 , UFS 906,
UFS 916, it is simply the case of only up-
loading the necessary SAT>IP-Software.
A selection of software for PCs, laptops,
tablet computers and Smartphones can be
found on our website “www.kathrein.de”
under the product description of the
EXIP 414.
To remove the link between the EXIP 414
and the respective SAT> IP-enabled device
please refer to the corresponding software
documentation. Normally this should be
done automatically due to the UPNP inter-
face.
Use
*
)
*
)
*
)
*
)
Up to 20 MBit/s of data are trans-
mitted per channel. Make sure
that your network technology has
sufcient capacity!
7 / 9
Problem Possible cause Solution
LED “Stream”
does not light up
No network connection Connect network cable
LED “Power”
does not light up
On/Off switch is
positioned on “off”
Check the switch on the rear panel
of the unit and set it to “on”
LED “Power”
does not light up
Power supply unit
is not connected
Insert the power supply unit into the
server and connect it to the 230-V mains
Possible causes of faults, and their remedies
Electronic equipment is not domestic waste, - it must be disposed of proper-
ly in accordance with directive 2002/96/EC OF THE EUROPEAN PARLIA-
MENT AND THE COUNCIL dated 27 January 2003 on waste electrical and
electronic equipment. At the end of its service life, please take this device to
a designated public collection point for disposal.
8 / 9
Connection examples (symbolic representation)
**) Over-voltage pro-
tection KAZ 11/12
UAS 584
IP
IP
IP
IP
IP
EXIP 414/E
936.4910/-/VMWI/0215/GB – Technical data subject to change!
Internet: www.kathrein.com
KATHREIN-Werke KG Anton-Kathrein-Straße 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-306
Type EXIP 414/E
Order no. 20510103
Subscriber connections 1 x 4
Frequency range MHz 950 – 2,150
Input 4 x Sat
Input level range dBµV 42 – 87
Impedance Ω 75
Permissible remote feed voltage input V 12 – 20
Max. permissible remote feed current mA 400
Output voltage horizontal V > 17.5 (at 400 mA)/< 19 (at 0 mA)
Output voltage vertical V > 12.5 (at 400 mA)/< 14 (at 0 mA)
Control signals 14/18 V, 22 kHz 0,6 V
pp
(EN 61319-1),
DiSEqC™1.0 (EN 61319-1 A11),
Single-cable system (EN 50494)
Power consumption of server W
typ. 12/min. 7
Permissible ambient temperature °C 0 – +40
Connections F-type connectors, RJ 45, 5.5 x 2.5 mm jack plug
Dimensions (W x D x H) mm 222 x 138 x 43
Packing unit/weight pc/kg 1(4)/approx. 0.75
Power supply unit
Nominal input voltage V 230
Secondary voltage V 12
Max. output current A 3
Fullls the directives EN 60065:2002 + A1:2006 +
A11:2008 + A2:2010 + A12:2011
DIN EN ISO 12100-2:2004 + A1:2009 partially
Technical Data
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Kathrein EXIP 414 User manual

Category
Networking
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages