VAT 61536-PHCG Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the VAT 61536-PHCG Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
1/94
Butterfly control & isolation valve
with extended control range
with RS232 interface
sample picture
This manual is valid for the valve ordering number(s):
615 . . - . . GG - . . . . (1 sensor input)
615 . . - . . GH - . . . . (2 sensor inputs)
615 . . - . . AG - . . . . (1 sensor input / 15V SPS)
615 . . - . . AH - . . . . (2 sensor inputs / 15V SPS)
615 . . - . . HG - . . . . (1 sensor input / PFO)
615 . . - . . HH - . . . . (2 sensor inputs / PFO)
615 . . - . . CG - . . . . (1 sensor input / 15V SPS / PFO)
615 . . - . . CH - . . . . (2 sensor inputs / 15V SPS / PFO)
615 . . - . . GV - . . . . (1 sensor input / analog outputs)
615 . . - . . GW - . . . . (2 sensor inputs / analog outputs)
615 . . - . . AV - . . . . (1 sensor input / analog outputs / 15V SPS)
615 . . - . . AW - . . . . (2 sensor inputs / analog outputs / 15V SPS)
615 . . - . . HV - . . . . (1 sensor input / analog outputs / PFO)
615 . . - . . HW - . . . . (2 sensor inputs / analog outputs / PFO)
615 . . - . . CV - . . . . (1 sensor input / analog outputs / 15V SPS / PFO)
615 . . - . . CW - . . . . (2 sensor inputs / analog outputs / 15V SPS / PFO)
SPS = Sensor Power Supply PFO = Power Failure Option
configured with firmware 615P.1E.44
The fabrication number is indicated on each product as per the label
below (or similar):
Fabrication No.:
615 . . . . . . . . . . / . . . .
A . . . . . .
Fabrication number
Explanation of symbols:
Read declaration carefully before you start any other
action!
Keep body parts and objects away from the valve
opening!
Attention!
Hot surfaces; do not touch!
Loaded springs and/or air cushions are potential
hazards!
Wear gloves!
Disconnect electrical power and compressed air lines.
Do not touch parts under voltage!
Read these «Installation, Operating & Maintenance Instructions» and the enclosed «General
Safety Instructions» carefully before you start any other action!
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
2/94
Imprint
Manufacturer
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Website
www.vatvalve.com
Phone
+41 81 771 61 61
Fax
+41 81 771 48 30
Publisher
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Editor
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Print
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Copyright
© VAT Vakuumventile AG 2011
No part of these Instructions may be reproduced in any way (photocopies, microfilms or any
other reproduction processes) nor may it be manipulated with electronic systems, duplicated or
distributed without written permission from VAT. Offenders are liable to pay damages.
The original VAT firmware and updated state of the art versions of the VAT firmware are
intended for use with VAT products. The VAT firmware contains a limited, time unlimited user
license. The VAT firmware may not be used for purposes other than those intended nor is it
permitted to make copies of the VAT firmware. In particular, it is strictly forbidden to give copies
of the VAT firmware to other people.
The use of trade names, brand names, trademarks, etc. in these Instructions does not entitle
third parties to consider these names to be unprotected and to use them freely. This is in
accordance with the meaning of the laws and acts covering brand names and trademarks.
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
3/94
Contents:
1 Use of product ........................................................................................................................................................... 5
1.1 Technical data .................................................................................................................................................. 5
2 Installation ................................................................................................................................................................. 9
2.1 Unpacking ........................................................................................................................................................ 9
2.2 Installation into the system ............................................................................................................................... 9
2.3 Tightening torque ........................................................................................................................................... 10
2.3.1 Mounting of CF-F flanges .................................................................................................................. 10
2.3.2 Mounting with centering rings ............................................................................................................ 11
2.3.3 Mounting with O-ring in grooves ........................................................................................................ 11
2.4 Admissible forces ........................................................................................................................................... 12
2.4.1 Admissible forces for valve body ....................................................................................................... 12
2.4.2 Admissible forces at controller ........................................................................................................... 13
2.5 Requirements to sensor connection ............................................................................................................... 14
2.6 Electrical connection ...................................................................................................................................... 15
2.6.1 Ground connection ............................................................................................................................ 15
2.6.2 Sensor supply concepts ..................................................................................................................... 16
2.6.3 Power and sensor connection (+24 VDC sensors) ............................................................................ 17
2.6.4 Power and sensor connection ( 15 VDC sensors) without optional SPS module .............................. 20
2.6.5 Power and sensor connection ( 15 VDC sensors) with optional SPS module ................................... 22
2.6.6 RS232 interface connection ............................................................................................................... 23
2.6.7 Service port connection ..................................................................................................................... 23
3 Operation ................................................................................................................................................................ 24
3.1 Introduction .................................................................................................................................................... 24
3.1.1 Local operation .................................................................................................................................. 25
3.1.2 Remote operation .............................................................................................................................. 25
3.1.3 Safety mode....................................................................................................................................... 26
3.1.4 Service indication ............................................................................................................................... 26
3.2 Operation under increased temperature ........................................................................................................ 26
3.3 Behavior during power up .............................................................................................................................. 26
3.4 Behavior in case of power failure ................................................................................................................... 27
3.5 Display information ......................................................................................................................................... 28
3.6 Setup procedure ............................................................................................................................................. 30
3.6.1 Interface configuration ....................................................................................................................... 30
3.6.2 Valve and sensor configuration .......................................................................................................... 31
3.6.3 ZERO ................................................................................................................................................. 31
3.6.4 Pressure control configuration ........................................................................................................... 32
3.6.5 Control algorithms .............................................................................................................................. 34
3.7 Close valve .................................................................................................................................................... 38
3.8 Open valve ..................................................................................................................................................... 38
3.9 Position control............................................................................................................................................... 38
3.10 Pressure control ............................................................................................................................................. 38
3.10.1 Operation with 2 sensors ................................................................................................................... 39
3.11 Tuning of pressure control performance ........................................................................................................ 39
3.11.1 Tuning of pressure control (adaptive) ................................................................................................ 40
3.11.2 Tuning of pressure control performance with fixed PI control ............................................................ 44
3.11.3 Tuning of pressure control (soft pump) .............................................................................................. 50
3.12 RS232 interface ............................................................................................................................................. 54
3.12.1 Settings .............................................................................................................................................. 54
3.12.2 Schematics ........................................................................................................................................ 55
3.12.3 Digital inputs ...................................................................................................................................... 57
3.12.4 Command syntax ............................................................................................................................... 58
3.12.5 RS232 control commands ................................................................................................................. 58
3.12.6 RS232 inquiry commands .................................................................................................................. 59
3.12.7 RS232 setup commands ................................................................................................................... 63
3.12.8 RS232 error messages ...................................................................................................................... 67
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
4/94
4 Trouble shooting ..................................................................................................................................................... 68
5 Maintenance & repairs ............................................................................................................................................ 71
5.1 Maintenance procedures ................................................................................................................................ 72
5.2 Option board .................................................................................................................................................. 85
5.2.1 Durability of power fail battery ............................................................................................................ 85
5.2.2 Retrofit / replacement procedure ....................................................................................................... 86
6 Drawing ................................................................................................................................................................... 89
7 Spare parts ............................................................................................................................................................. 90
7.1 ISO-F valve unit aluminum hard anodized, without heating ........................................................................ 90
7.2 ISO-F valve unit stainless steel, without heating ......................................................................................... 90
7.3 Seals .............................................................................................................................................................. 91
7.4 Accessories .................................................................................................................................................... 91
7.4.1 Centering ring with Viton o-ring .......................................................................................................... 92
8 Warranty ................................................................................................................................................................. 93
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
5/94
1 Use of product
This product is a Butterfly control valve with isolation functionality for downstream pressure control in vacuum systems.
Use product for clean and dry indoor vacuum applications under the conditions indicated in chapter «Technical data» only!
Other applications are only allowed with the written permission of VAT.
1.1 Technical data
Control and actuating unit
Power input 1) (α)
+24 VDC (±10%) @ 0.5 V pk-pk max.
[connector: POWER]
[615 . . - . . A . - . . . . / 615 . . - . . G . - . . . . ]
[615 . . - . . C . - . . . . / 615 . . - . . H . - . . . . ]
38 W max. (operation of valve with max. load) without PFO 4)
38 W plus 10 W for PFO 4)
Sensor power supply 2) (β)
[615 . . - . . A . - . . . . / 615 . . - . . C . - . . . . ]
Input
Output
+24 VDC / 1500 mA max.
±15 VDC (±5%) / 1000 mA max.
[connector: POWER]
[connector: SENSOR]
Sensor power supply 2) (β)
[615 . . - . . G . - . . . . / 615 . . - . . H . - . . . . ]
Input
Output
+ 24 VDC resp. ± 15 VDC
same as input but:
2.0 A max. at ± 15 VDC
1.5 A max. at + 24 VDC
[connector: POWER]
[connector: SENSOR]
Calculation of complete power consumption:
Ptot = α + β
whereas β depends on sensor supply concept and sensor power consumption.
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
6/94
Control and actuating unit (continuation)
Sensor input
Signal input
ADC resolution
Sampling time
0-10 VDC / Ri>100 kΩ
0.23 mV
10 ms
[connector: SENSOR]
Digital inputs 3)
±24 VDC max.
Digital outputs 3)
Input voltage
Input current
Breaking capacity
70 VDC or 70 V peak max.
0.5 ADC or 0.5 A peak max.
10 W max.
Analog outputs 3)
0-10 VDC / 1 mA max.
PFO 4) battery pack
[615 . . - . . C . - . . . . / 615 . . - . . H . - . . . . ]
Charging time
Durability
2 minutes max.
up to 10 years @ 25°C ambient;
refer to «Durability of power fail battery» for details
Ambient temperature
0 °C to +50 °C max. (<35 °C recommended)
Pressure control accuracy
5 mV or 0.1% of setpoint, whichever is greater
Position resolution / position control capability
> 28000
Closing time throttling only
0.5 s typ. (full stroke)
Opening time throttling only
0.5 s typ. (full stroke)
Closing time throttling & isolation
0.6 s typ. (full stroke)
Opening time throttling & isolation
0.6 s typ. (full stroke)
1) Internal overcurrent protection by a PTC device.
2) Refer to chapter «Sensor supply concepts» for details.
3) Refer to chapter «Schematics» for details.
4) PFO = Power Failure Option. Refer to «Behavior in case of power failure» for details.
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
7/94
Valve unit
Pressure range at 20 C
- Aluminum hard anodized (615 . . - . H. . - . . . . )
1 x 10E-6 mbar to 1.2 bar (abs)
- Stainless steel (615 . . - . E. . - . . . . )
1 x 10E-8 mbar to 1.2 bar (abs)
Leak rate to outside at 20 C
- Aluminum hard anodized (615 . . - . H. . - . . . . )
1 x 10E-5 mbar l/s
- Stainless steel (615 . . - . E. . - . . . . )
1 x 10E-9 mbar l/s
Leak rate seat at 20°C
- Aluminum hard anodized (615 . . - . H. . - . . . . )
1 x 10E-4 mbar l/s
- Stainless steel (615 . . - . E. . - . . . . )
1 x 10E-9 mbar l/s
Cycles until first service:
- Isolation cycles (open - closed - open)
100’000 (with FKM (e.g. Viton®) seals, unheated and under clean conditions)
- Throttling cycles (open - max. throttle - open)
2’000’000 (with FKM (e.g. Viton®) seals, unheated and under clean
conditions)
Admissible operating temperature
10°C to +120°C
Mounting position
Valve seat must face chamber side
Wetted materials
- Body, plate (615 . . - . H. . - . . . . )
Aluminum 3.2315 (AA6082) hard anodized
- Body, plate (615 . . - . E. . - . . . . )
Stainless steel 316L (1.4404 or 1.4435)
- Shaft
Stainless steel 316L (1.4404 or 1.4435)
- Plate screws
Stainless steel 316L (A4)
- Shaft seal
- Plate seal
FKM (e.g. Viton®)
FKM (e.g. Viton®)
- Slide bearing for shaft
iglidur® X
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
8/94
Valve unit (continuation)
DN 63
2½"
(61536 - ....)
DN 80
3"
(61538 - ....)
DN 100
4"
(61540 - ....)
Max. differential pressure on plate
1000 mbar
1000 mbar
1000 mbar
Min. controllable conductance (Cmin)
[N2 molecular flow]
0.15 l/s
0.2 l/s
0.25 l/s
Conductance in open position [N2 molecular flow]
220 l/s
360 l/s
600 l/s
Weight:
Aluminum hard anodized (615 . . - . H. . - . . . .
)
3.8 kg
4.8 kg
5.2 kg
Weight:
Stainless steel (615 . . - . E. . - . . . . )
5.9 kg
8.8 kg
9.7 kg
Dimensions
Refer to dimensional drawing of specific valve ordering number
(available on request)
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
9/94
2 Installation
2.1 Unpacking
Valves DN63 / 2½" and larger must not be lifted solely by the actuator.
2.2 Installation into the system
Fingers and objects must be kept out of the valve opening and away from moving parts.
The valve plate may start to move just after power is supplied.
Do not connect or disconnect sensor cable when device is under power.
Connection overview Connectors at controller panel
Ground
connection
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
10/94
1. Install valve [1] into the vacuum system. Valve seat side must face process chamber. The valve seat side is indicated
by the symbol " " on the valve flange.
Caution: Do not tighten the flange screws stronger than indicated under «Tightening torque».
Caution: Do not admit higher forces to the valve than indicated under «Admissible forces».
Note: Make sure that enough space is kept free to do preventive maintenance work. The required space is indicated
on the dimensional drawing.
Note: Control unit of valves with ISO-KF flanges (615 . . K . . . ) needs support when mounted on horizontal piping
and control unit does not hang.
2. Install the ground connection cable at controller. Refer to «Electrical connection»
3. Install sensor(s) [2] according to the recommendations of the sensor manufacturer and directives given under
«Requirements to sensor connection».
4. Connect pressure sensor cable [3] to sensor(s) and then to valve (connector: SENSOR). Refer to chapter «Electrical
connection» for correct wiring.
Note: Input for second sensor is available on 615 . . - . . . H - . . . ., 615 . . - . . . W - . . . . and 615 . . - . . . Z - . . . .
versions only.
5. Connect valve to remote control unit [4] (connector: INTERFACE). Refer to «RS232 connection» for correct wiring.
6. Connect power supply [5] to valve (connector: POWER). Refer to chapter «Electrical connection» for correct wiring.
Note: To provide power to the valve motor pins 4 and 8 must be bridged, otherwise motor interlock is active and the
valve enters the safety mode and is not operative. Refer also to «Safety mode».
7. This valve may optionally be equipped with a heating device. Connect VAT heating device according to manual of
respective heating device.
8. Perform «Setup procedure» to prepare valve for operation.
Note: Without performing the setup procedure the valve will not be able to do pressure control.
2.3 Tightening torque
Tighten mounting screws of the flanges uniformly in crosswise order. Observe the maximum torque levels in the following
table. Higher tightening torques deforms the valve body and may lead to malfunction of the valve.
2.3.1 Mounting of CF-F flanges
Tightening torques for CF-F flange connections depend on the type of seal which is used. Follow recommendations of seal
manufacturer.
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
11/94
2.3.2 Mounting with centering rings
Valve size
ISO-F
ISO-F
max. tightening torque
(Nm)
max. tightening torque
(lbs . ft)
DN63 / 2½ “
(61536 - . . . . - . . . . )
8-10
6-8
DN80 / 3“
(61538 - . . . . - . . . . )
8-10
6-8
DN100 / 4“
(61540 - . . . . - . . . . )
8-10
6-8
hole depth (mm)
hole depth (inch)
DN63 / 2½ “
(61536 - . . . . - . . . . )
12
0.47
DN80 / 3“
(61538 - . . . . - . . . . )
12
0.47
DN100 / 4“
(61540 - . . . . - . . . . )
12
0.47
Caution: Make sure that screws are not too long otherwise the valve body may be damaged.
Note: Use slightly lubricated screws.
Refer to «Spare parts and accessories» for centering rings ordering numbers.
2.3.3 Mounting with O-ring in grooves
Valve size
ISO-F
JIS
ASA-LP
ISO-F
JIS
ASA-LP
max. tightening torque
(Nm)
max. tightening torque
(lbs . ft)
DN63 / 2½ “
(61536 - . . . . - . . . . )
20-23
35-40
35-40
15-17
26-30
26-30
DN80 / 3“
(61538 - . . . . - . . . . )
20-23
35-40
35-40
15-17
26-30
26-30
DN100 / 4“
(61540 - . . . . - . . . . )
20-23
35-40
35-40
15-17
26-30
26-30
hole depth (mm)
hole depth (inch)
DN63 / 2½ “
(61536 - . . . . - . . . . )
12
n/a
n/a
0.47
n/a
n/a
DN80 / 3“
(61538 - . . . . - . . . . )
12
n/a
n/a
0.47
n/a
n/a
DN100 / 4“
(61540 - . . . . - . . . . )
12
n/a
n/a
0.47
n/a
n/a
Caution: Make sure that screws are not too long otherwise the valve body may be damaged.
Note: These torques are valid if depth of the mounting screws is min. 1 x thread diameter. Make sure that screws in use
are capable to withstand applied torques. Lubricate screws slightly.
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
12/94
2.4 Admissible forces
2.4.1 Admissible forces for valve body
Forces from the weight of other components can lead to deformation of the valve body and to malfunction of the valve. The
stress has to be relieved by suitable means. The following forces are admissible:
Valve
size
Axial tensile or
compressive force «FA»
Bending moment «M»
mm
inch
N
lb.
Nm
lbf.
63
800
176
32
24
80
3
850
187
35
26.5
100
4
1000
220
40
30
M
FA
FA
M
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
13/94
2.4.2 Admissible forces at controller
Attention!
Do not pushing, shocking load, or stressing the valve controller!
Do not deposit anything at valve controller!
The admissible force at valve controller in regards to the pedestal is shown in table below. In case higher force is
applied, the pedestal could be permanently damaged!
Admissible force «F»
Overview
F = Force
a = middle of aluminium part of controller (b / 2)
400 N
F
b
pedestal
a
a
pedestal
b
a
a
F
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
14/94
2.5 Requirements to sensor connection
To achieve fast and accurate pressure control a fast
sensor response is required.
Sensor response time: < 50ms
The sensor is normally connected to the chamber by a
pipe. To maintain that the response time is not degraded
by this connection it needs to meet the following
requirements:
Inner diameter of connection pipe: > = 10 mm
Length of connection pipe: < = 300 mm
These conductance guidelines must include all valves and
limiting orifices that may also be present.
Make also sure that there is no obstruction in front of
sensor connection port inside the chamber.
The sensor should also be mounted free of mechanical
shock and vibration.
Dynamic stray magnetic fields may introduce noise to
sensor output and should be avoided or shielded.
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
15/94
2.6 Electrical connection
2.6.1 Ground connection
Recommendation for ground strap between controller and system (chassis)
Material
L (Length max.)
B1 (min.)
B2 (min.)
d1 ( )
d2 ( )
copper tinned
200 mm
25 mm
25 mm
4.5 mm
customized
Note: Connection plates of ground strap must be total plane for a good electrical contact!
Note: The connection point at chassis (FE) must be blank metal (not coated).
It is also possible to connect the ground strap at system chamber if it is well connected to PE.
Note: Avoid low chassis cross section to the system PE connection. (Min. same cross section as ground strap)
Valve controller
System
Ground connection
Chassis (FE)
(Functional Earth)
B1
B2
d1
d2
L
Ground strap
PE
Recommended torque: 1,3…1,7Nm
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
16/94
2.6.2 Sensor supply concepts
This valve offers 3 alternative concepts to supply the sensor(s) with power. This depends on the sensor type and valve
version that is used. This valve is available with an optional sensor power supply module (SPS) that converts 15 VDC
from the 24 VDC.
Concepts:
External + 24 VDC supplied to POWER connector is feed through to SENSOR connector to supply 24 VDC
sensors. Refer to chapter «2.6.3 Power and sensor connection (+24 VDC sensors)» for schematic and correct
wiring.
External 15 VDC supplied to POWER connector is feed through to SENSOR connector to supply 15 VDC
sensors. Refer to chapter «2.6.4 Power and sensor connection ( 15 VDC sensors) without optional SPS module»
for schematic and correct wiring.
External + 24 VDC supplied to POWER connector is converted into 15 VDC by the valve internal SPS and
supplied to SENSOR connector to supply 15 VDC sensors. Refer to chapter «2.6.5 Power and sensor
connection ( 15 VDC sensors) with optional SPS module» for schematic and correct wiring.
Valve versions:
615 . . - . . G . - . . . . / 615 . . - . . H . - . . . . SPS module not included
615 . . - . . A . - . . . . / 615 . . - . . C . - . . . . SPS module included
Note: The SPS module can be retrofitted. Refer to chapter «Retrofit / replacement procedure» for instruction.
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
17/94
2.6.3 Power and sensor connection (+24 VDC sensors)
[615 . . - . . G . - . . . . / 615 . . - . . H . - . . . . versions recommended]
2.6.3.1 Sensor power wiring via controller
Note:
Use shielded sensor cable(s). Keep cable as short as possible, but locate it away from noise sources.
Connect the +24 VDC sensors at DB15 female sensor connector exactly as shown in the drawing above.
Do not connect other pins that may damage sensors, power supply or controller!
Connector: Use only screws with 4-40UNC thread for fastening the connectors!
Pins 4 and 8 must be bridged for operation!
An optional switch would allow for motor
interlock to prevent valve from moving.
Low range sensor may be connected
to sensor 1 or sensor 2 input.
Do configuration accordingly.
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
18/94
2.6.3.2 Sensor power wiring external
Note:
Use shielded sensor cable(s). Keep cable as short as possible, but locate it away from noise sources.
Connect the +24 VDC sensors at DB15 female sensor connector exactly as shown in the drawing above. Do not
connect other pins that may damage sensors, power supply or controller!
Connector: Use only screws with 4-40UNC thread for fastening the connectors!
Low range sensor may be connected
to sensor 1 or sensor 2 input.
Do configuration accordingly.
Pins 4 and 8 must be bridged for operation!
An optional switch would allow for motor
interlock to prevent valve from moving.
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
19/94
Installation, Operating & Maintenance Instructions
Series 615 DN 63-100 (I.D. 2.5“ - 4”), RS232
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
292443EB
2013-11-27
20/94
2.6.4 Power and sensor connection ( 15 VDC sensors) without optional SPS module
[615 . . - . . G . - . . . . / 615 . . - . . H . - . . . . versions only]
2.6.4.1 Sensor power wiring via controller
Note:
Use shielded sensor cable(s). Keep cable as short as possible, but locate it away from noise sources.
Connect the 15 VDC sensors at DB15 female sensor connector exactly as shown in the drawing above.
Do not connect other pins that may damage sensors, power supply or controller!
Connector: Use only screws with 4-40UNC thread for fastening the connectors!
Pins 4 and 8 must be bridged for operation!
An optional switch would allow for motor interlock to
prevent valve from moving.
Low range sensor may be connected
to sensor 1 or sensor 2 input.
Do configuration accordingly.
Fuse 1A
Fuse 1A
/