SiENBE28-901 Standard Specification
Air Cooled Refrigeration Condensing Unit 17
LRLEQ15A, 20AY1(E)
LRMEQ15A, 20AY1(E)
POWER SUPPLY
Y1: 380-415V 3N~50Hz GRN C1
A2P
RED
X400A
GRN
WHT
BLU
BLK
Z1F
Z10C
N=4
K4M
F400U
X401A
X403A X402A
BLK
WHT
RED
A3P
X10A X1A
X61A Z2C
N=1
K2M
V2R
P1
K1R
R95
WHT
L1R
WHT
P2
C66 C63
R50 R59
V1R
X11A
Z3C
N=5
RED
WHT
BLK
UVW
MS
3~
M1C
X28A
X20A
X6A
X4A
Z4C
N=1
PS
N3
P3
BLK
RED
A4P
X5A
X3A
X5A
X41A
X111A
t°
R1T
P1
F1U
N1
R10
X4A
V1R
X2A
5
X2A
5
MS
3~
M1F
RED
WHT
BLK
Z5C
N=1
X1A
X1A
A1P
X1A
RED
BLU
BLK
F1U
F2U
Q1RP
P<
S1PH
X2A
X3A
X4A
V1CP
X7A X9A X10A X14A
K3R
K5R
K6R
K10R
Y3S F4U
F3U
CC1 W1 P1 P2 X2M
CAUTION
OUTPUT
NOTE)5
WARNING
OUTPUT
NOTE)5
OPERATING
OUTPUT
NOTE)6
X66A
A5P
X1M
ABC
S1S
X1A
REMOTE OFF ON
4
32
1
X3M
1
2
NOTE)4
SWITCH
t°
R31T
t° t° t° t°
R2T R3T R5T R6T
X29A X30A
PS
H1P H2P H3P H4P H5P H6P H7P H8P
BS1 BS2 BS3 BS4 BS5 HAP
DS1
ON
OFF 1234
DS2
ON
OFF 1234
IS CONNECTOR COLOR FOR PRINTED
CIRCUIT BOARD.
IS CONNECTOR COLOR FOR COMPONENT.
IS DISCRIMINATION COLOR FOR
COMPONENT LEAD WIRE.
X36A
X18A
X31A
X32A
X21A
BLK
X22A
P< S4PH
t° R1T
S1NPL
S1NPH
5
Y1E
M
WHT
BLK
5
Y2E
M
TERMINAL OF M1C~M3C
U
V
W
LAYOUT OF M1C~M3C, M1F, M2F
CONTROL, BOX
M1C
M1F
OUTER SHELL
CONTROL. BOX
A1P
S1S
X2M
A9P
X1A
X2A
X1M
A5P
X3M
(FRONT)
A3P
A2P
L1R
A4P
(BACK)
A1P PRINTED CIRCUIT BOARD (MAIN) K3R MAGNETIC RELAY (CAUTION OUTPUT) S1PH~3PH PRESSURE SWITCH (HIGH)
A2P
PRINTED CIRCUIT BOARD (NOISE FILTER)
K4R MAGNETIC RELAY (Y2S) S4PH PRESSURE SWITCH (HIGH)
A3P PRINTED CIRCUIT BOARD (INV) K5R MAGNETIC RELAY (Y3S) S1S OPERATION SWITCH (REMOTE/OFF/ON)
A4P, A8P PRINTED CIRCUIT BOARD (FAN) K6R MAGNETIC RELAY (WARNING OUTPUT) T1A CURRENT SENSOR (A6P, A7P)
A5P PRINTED CIRCUIT BOARD (ABC I/P) K10R
MAGNETIC RELAY (OPERATING OUTPUT)
T2A CURRENT SENSOR (A9P)
A6P, A7P
PRINTED CIRCUIT BOARD (CURRENT SENSOR)
K11R MAGNETIC RELAY (Y5S) V1CP SAFETY DEVICES INPUT
A9P
PRINTED CIRCUIT BOARD (EARTH LEAKAGE DETECTOR)
L1R REACTOR (A3P) V1R POWER MODULE (A3P, A4P, A8P)
BS1~5 PUSH BUTTON SWITCH
(MODE, SET, RETURN, TEST, RESET)
M1C~3C MOTOR (COMPRESSOR) V2R DIODE BRIDGE (A3P)
M1F, M2F MOTOR (FAN) X1A~4A CONNECTOR (M1F, M2F)
C1 CAPACITOR PS SWITCHING POWER SUPPLY (A1P, A3P) X105A CONNECTOR (S3PH)
C63, C66 CAPACITOR (A3P) Q1RP PHASE REVERSAL DETECT CIRCUIT X1M TERMINAL STRIP (POWER SUPPLY)
DS1, DS2 DIP SWITCH (A1P) R10
RESISTOR (CURRENT SENSOR) (A4P, A8P)
X1M TERMINAL STRIP (OPERATION) (A5P)
F1U FUSE (8A, DC650V) (A4P, A8P) R50, R59 RESISTOR (A3P) X2M TERMINAL STRIP
F1U, F2U FUSE (T, 3.15A, 250V) (A1P) R95 RESISTOR (CURRENT LIMITING) X3M TERMINAL STRIP (REMOTE SWITCH)
F3U, F4U FUSE (T, 1.0A, 250V) R1T THERMISTOR (AIR) (A1P) Y1E ELECTRONIC EXPANSION VALVE (MAIN)
F400U FUSE (T, 6.3A, 250V) (A2P) R1T THERMISTOR (FIN) (A3P) Y2E ELECTRONIC EXPANSION VALVE (GAS)
H1P~8P
PILOTLAMP (SERVICE MONITOR-ORANGE)
[H2P] MALFUNCTION DETECTION---LIGHT UP
R2T THERMISTOR (SUCTION) Y3E ELECTRONIC EXPANSION VALVE (M1C)
R31~33T THERMISTOR (M1C~3C DISCHARGE) Y2S SOLENOID VALVE (M2C)
R3T THERMISTOR (HEAT EXC, DEICER) Y3S SOLENOID VALVE (4 WAY VALVE)
HAP PILOTLAMP (SERVICE MONITOR-GREEN) R5T
THERMISTOR (HEAT EX, OF SUBCOOL OUTLET)
Y5S SOLENOID VALVE (M3C)
K1R,K3R MAGNETIC RELAY R6T
THERMISTOR (HEAT EX, OF SUBCOOL INLET)
Z1C~10C NOISE FILTER (FERRITE CORE)
K2M, K4M MAGNETIC CONTACTOR (M1C) RY1 MAGNETIC RELAY (A9P) Z1F
NOISE FILTER (WITH SURGE ABSORBER) (A2P)
K2M, K3M MAGNETIC CONTACTOR (M2C, M3C) S1NPH PRESSURE SENSOR (HIGH)
K1R, K2R MAGNETIC RELAY (K2M, K3M) S1NPL PRESSURE SENSOR (LOW)
3D063035B
A6P
K2M
BLU
WHT
Y3E
M
5
BLU
X23A
R32T
t°
X8A
K4R
Y2S
P<
S2PH
K1R
X5A
RED
WHT
K2M
A1
A2
X26A
M
3~
M3C
Z8C
N=5
RED
WHT
BLK
UV W
K3MUV W
RS T
A6P
T1A
X1A
K3R
Z1C
N=1
RED
WHT
BLK
BLU
X1M
L1
L2
L3
N
L1
L2
L3
N
NOTES)
1. THIS WIRING DIAGRAM IS APPLIED ONLY
TO THE OUTDOOR UNIT.
2. : FIELD WIRING.
3. : TERMINAL STRIP : CONNECTOR :TERMINAL :PROTECTIVE EARTH (SCREW)
4. AT THE TIME OF FACTORY SHIPMENT, SETTING OF "OFF". WHEN OPERATING, SETTING OF "ON" OR "REMOTE".
THE POINT OF CONTACT OF THE INPUT MUST USE THE ONE FOR A SLIGHT CURRENT.
(FOR THE REMOTE SWITCH, USE NON-VOLTAGE CONTACT FOR MICROCURRENT (NOT MORE THAN 1mA DC12V))
5. BE NOTED THAT THE CAPACITY OF CONTACT IS AC220~240V, 0.5A. (TOTAL OF CAUTION OUTPUT, WARNING OUTPUT)
6. BE NOTED THAT THE CAPACITY OF CONTACT IS AC220~240V, 0.5A. (OPERATING OUTPUT)
7. HOW TO USE BS1~5, DS1 AND DS2 SWITCH, REFER TO "SERVICE PRECAUTION" LABEL ON EL. COMPO. BOX COVER.
8. WHEN OPERATING, DON'T SHORTCIRCUIT THE PROTECTION DEVICE (S1PH~S3PH).
9. COLORS BLK:BLACK RED:RED BLU:BLUE WHT:WHITE GRN:GREEN.
10. RY1 POINT CONTACT IS OPEN BEFORE TURNING ON POWER SUPPLY.
REFER TO TECHNICAL GUIDE FOR THE OPERATION TIMING DIAGRAM.
M2F
M2C
M3C
X4A
X3A
A7P
K3M
A8P
t°
R33T
Y5S
X15A
K11R
X105A
P<
S3PH
K2R
X6A
RED
WHT
K3M
A1
A2
X25A
NOTE) 10
RY1
X2A
X1A X3A
A9P
Z6C
N=1
T2A
N=1
A7P
T1A
X1A
BLK
RED
M
3~
M2C
Z7C
N=5
RED
WHT
BLK
UV W
K2MUV W
RS T
P2 N2
X51A
A8P
X5A
X3A
P1
F1U
N1
R10
X4A
X2A
5
X4A
5
MS
3~
M2F
RED
WHT
BLK
Z9C
N=1
X3A
X1A
V1R
RED RED
WHT
WHT
RED