Satco 86-222, 86-221 Operating instructions

  • Hello! I've reviewed the wiring instructions for the SATCO photocells 86/221 and 86/222. This document provides detailed steps for installing these photocells with LED area lights and includes specifications for different wattage models and dimming control setup. If you have any questions about the installation steps or the wiring process, feel free to ask!
  • What is the first step in wiring the photocell?
    What wires need to be connected in step 4?
    What wiring connections are described for dimming control?
Wiring Instructions for 86/221 and 86/222 Photocells for LED Area Light Models:
86/221 fits models: 65/840, 65/841, 65/842, 65/843, 65/844, 65/845, 65/850, 65/851, 65/852, 65/853, 65/854, 65/855.
86/222 fits models: 65/846, 65/847, 65/848, 65/849, 65/856, 65/857, 65/858, 65/859.
Step 1: Remove the round photocell cover plate by removing the four machine screws
and install the photocell socket with provided (2) machine screws.Fig 1.
Step 2: to integrate the photocell; Open the Fixture wiring compartment located
underneath the photocell location by removing the two machine screws,Fig 2.
Step 3: Separate the two black wires from the WEGO connector; (re-used the two port
WEGO wire connectors) and identify the two black wires, one leading to the LED Driver
and the second to the AC input, leading from the mount arm input wire whip Fig 3.
Step 4: Connect the (Load) Red wire from the photocell to the (Line) Black wire
leading from the LED Driver. Fig 4.
Step 5: Connect the (Line) Black wire from the photocell to the (Line) Black wire leading
from the mount arm input wire whip.Fig 5.
Step 6: Remove the second WEGO connector from the two (Neutral) White wires,
Leading from AC input and the LED Driver, reconnect to the two (Neutral) white wires
Plus, the (Neutral) white wire leading from the photocell, a 3-port wire connector,
or a regular wire connector is required)Fig 6.
Step 7: Now the wiring is complete, install the photocell to the photocell socket and ensure the
photocell is secure properly by turning clockwise.
Step 8: If using 0-10V dimming control connect the positive (Purple +) to the (Purple DIM +) and
the Pin/Grey to the (Pink DIM-).
Step 9: Restore power at the fuse or circuit breaker box; Now the installation is complete.
www.satco.com
86/221 100-200W
86/222 240 300W Photocell
Photocell Socket.
Fig 3.
Fig 3.
AC-100-277V
Fig 2.
Verify the input supply voltage is correct by comparing it with the Photocell
and Area Light label information.
Warning: Turn off electrical power at the fuse or circuit breaker box before
wiring the photocell to the Area light.
Fig 6. Fig 4. Fig 5.
LED Driver
(L1)
(L)
/