The Cleveland Range (2)21-CET-8 is an electric convection steamer designed for commercial use in restaurants, hotels, and other foodservice establishments. It features a stainless steel construction for durability and easy cleaning, and has a capacity of 8 full-size sheet pans. The steamer's mechanical timer allows for precise cooking times, and its automatic water fill system ensures a consistent water level throughout the cooking process. The Cleveland Range (2)21-CET-8 also includes a descaling indicator and reset switch to help maintain the steamer's performance and longevity.

The Cleveland Range (2)21-CET-8 is an electric convection steamer designed for commercial use in restaurants, hotels, and other foodservice establishments. It features a stainless steel construction for durability and easy cleaning, and has a capacity of 8 full-size sheet pans. The steamer's mechanical timer allows for precise cooking times, and its automatic water fill system ensures a consistent water level throughout the cooking process. The Cleveland Range (2)21-CET-8 also includes a descaling indicator and reset switch to help maintain the steamer's performance and longevity.

Statement of Responsibilities
This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service
Representatives who are familiar with both the safety procedures, and equipment they service.
Cleveland Range, LLC assumes no liability for any death, injury, equipment damage, or property damage
resulting from use of, improper use of, or failure to use the information contained in this document.
Cleveland Range, LLC has made every effort to provide accurate information in this document, but
cannot guarantee that this document does not contain unintentional errors and omissions.
The information in this document may be subject to technical and technological changes, revisions, or
updates.
Cleveland Range, LLC assumes no liability or responsibility regarding errata, changes, revisions, or
updates.
Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to follow industry
standard safety procedures, including, but not limited to, OSHA regulations, and disconnect / lock out /
tag out procedures for all utilities including steam, and disconnect / lock out / tag out procedures for gas,
electric, and steam powered equipment and / or appliances
All utilities (gas, electric, water and steam) should be turned OFF to the equipment and locked out of
operation according to OSHA approved practices during any servicing of Cleveland Range equipment
Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to maintain up-to-date
knowledge, skills, materials and equipment.
Cleveland Range, LLC
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110
Ph: 1-216-481-4900 Fx: 1-216-481-3782 Visit our Web Site at www.clevelandrange.com
CLEVELAND RANGE 21CET8
SEQUENCE OF OPERATIONS
Mechanical Timer
1. Supply power is sent to the primary of the main transformer.
115 VAC is sent from the secondary of the main transformer to the on/off rocker,
2. To turn the unit on, depress the red on/off rocker switch.
115 VAC is sent to the red power light.
115 VAC is sent to normally open drain valve closing it.
115 VAC is sent to H and N on the water level board
3. With the water level board energized and no water in the generator
5 seconds later 115 VAC is sent from the FILL terminal to the fill solenoid.
The fill solenoid opens and the generator fills through the drain valve.
The water fills to the low probe shorting it to ground
115 VAC is sent to the heat standby timer which will energize 3 seconds every 4
minutes to maintain heat while unit is idle
115 VAC is sent from the HEAT terminal to the timed manual switch.
4. When the timed/manual switch is in the timed position and time is on the timer
115 VAC is sent from the timer to the R2 relay coil
R2 relay energizes closing the R2A and R2B contacts
115VAC is sent through the now closed R2B contacts to the timer motor
115 VAC is sent through the now closed R2A contacts through the door switch to the
normally closed contacts of the high limit switch.
115 VAC is then sent through the high limit to the coil of condensate solenoid
The condensate solenoid opens spraying cold water down the compartment drain.
115 VAC is also sent through the high limit to the coil of the contactor.
115 VAC is sent to the clean light timer.
When the clean light timer times down 115 VAC is sent to the clean light switch.
When the clean light switch is depressed the clean light timer is reset.
5. When the contactor coil is energized supply voltage is sent to both of the elements.
The elements are energized and the water is heated to steam.
Steam is directed to the cooking compartment.
6. When the timer times out
115 VAC is sent to the 3 second timer and then to the buzzer for 3 seconds.
115 VAC is removed from the R2 relay.
R2A contacts open de energizing the heat circuit
R22B relay contacts open removing the 115 VAC from the timer motor
7. When the water level reaches the high probe then 115 VAC is removed from the FILL
terminal and the fill solenoid is turned off.
8. After the water level drops below the high probe for 5 seconds 115 VAC is sent to the FILL
terminal again.
9. The red on/off switch is depressed and the unit is turned off.
115 VAC is removed from the heat and timer circuit.
115 VAC is removed from the normally open drain valve allowing the steamer to drain.
115 VAC is sent to the 3-minute timer and the fill solenoid is energized for 3 minutes
flushing the drain.
STEAMCRAFT 3.1 MECHANICAL TIMER (PROBE)
FIELD CONVERSION FROM 3Ø
TO 1Ø IS NOT PERMITTED
DRYING ELEMENT
HEATING ELEMENTS
DRYING ELEMENT
CONTACTOR
CUSTOMER
CONNECTION
L1
L2
TB
CUSTOMER
CONNECTION
L3
TB
L1
L2
HEATING ELEMENTS
CONTACTOR
TIMER
DESCALE
BLK
23
87
4
5
6
1
& RESET SWITCH
DESCALE INDICATOR
L
NO
NO
L
A
WHT
3
2
3 MIN TIMER
SWITCH
1
WATER
BOARD
HI
N
3 SEC TIMER
1
2
3
BUZZER
XL
POWER ON
R
HEAT
FILL
H
FILL VALVE
C
HEAT STANDBY
TIMER
3
2
1
( STACKED UNITS OPTION )
CONTACTOR
CONDENSER
R1
NO C
SWITCH
HI LIMIT
VALVE
( OPT )
BLOWDOWN OPTION
1
3
2
R1
C NC
INTERMITTENT
TIMER
BLOWDOWN
DRAIN VALVE
COOLING FAN
L106347 M
R1
PROBES
TO
POWER
TB
W/ NEUTRAL
L2
L3
N
CUSTOMER
CONNECTION
380/415V
L1
FU
FU
FU
FU
H4
X1
H1 PRIMARY
X2 SECONDARY
120V
RESET CIRCUIT
BREAKER
FU
FU
(SCS OPT)
DOOR
MANUAL
ELECTRO-MECHANICAL
MOTOR
NC
TIMER
NO
C
SWITCH
TIMED TIMEDMANUAL
R2
R2A
NO
C
R2B
C NO
P106347 M
19994 - DESCALE IND RESET SWITCH
PARTS LIST:
INTERMITTENT BLOWDOWN OPTION
WHT
23
BLK
( TO HIGH LIMIT )
8
9
RED
BLK
6
109239 - HEAT STANDBY TIMER
108331 - RESET CIRCUIT BRKR
300022 - CONTACTOR
103731 - HI LIMIT SWITCH
22218 - WATER SOLENOIDS
107211 - COOLING FAN ( OPT )
22221 - DRAIN VALVE
44168 - TERMINAL BLOCK
( TO COND SOL )
RED
GRN
13
12
11
10
9
8
7
106911 - DESCALE TIMER
20478 - 3 MIN TIMER
104224 - TIMED / MANUAL SW
19993 - POWER SWITCH
FILL
BRN
( THRU SCS )
2
4
5
3
1
BLK
COND
GRN
WHT/BRN
BRN
10
BLU
RED
BLK
WHT/BLU
11
BLK
BRN
WHT
WHT
STEAMCRAFT 3.1 MECHANICAL TIMER (PROBE)
RED
YEL
WHT/BLK
BLU
TAN
HEAT FILL
15
GRN
RED
BLK
BLK
BLK
X2X1
WHT
TAN
RED
NH
HI
XL
C
WHT
L2
CUSTOMER CONNECTION
BRN
WHT/BRN
24
L1
25
L3
VOLT
208/240
H3
WHT/BLU
H4 H2
WHT
WHT
H1
WHT
WHT
BLK
14
101541 - TERM BLOCK SECTIONAL
101540 - END SEGMENT
25
24
108880 - DOOR SW ( MAGNETIC )
106541 - INTMT BLOWDOWN TIMER
DRYING ELEMENT
105966 - RELAY
104234 - CONTACTOR
20477 - 3 SEC TIMER
110198 - MOTORIZED TIMER
41350 - BUZZER
18
21
23
22
20
19
17
DRYING ELEMENT
ELEMENT
HEATER
WHT
RED
WHT
BLK
ELEMENT
HEATER
RED
BLK
12
13
BLK
BLK
BLK
SINGLE PHASE WIRING CONFIGURATION
L1 L2 L3
CONNECTION
TERMINAL BLOCK
CUSTOMER
WHT/BLK
WHT/BRN
TO
FUSE BLOCK
4
3
RED
21
WHT/RED
WHT
TAN
TAN
2
1
3
BLU
6
HEATER
ELEMENT
WHT
RED
DRYING ELEMENT
HEATER
ELEMENT
WHT
BLK
RED
BLK
BLK
DRYING ELEMENT
22
RED
1 RED
RED
WHT
2
3
YEL
WHT
BLK1
2
3
RED
BRN
BRN
7
3
4
58
1
6
2
BLK
5
1
3
2
YEL
BLK
6
7
WHT
7
20535 - TRANSFORMER
107239 - PROBE
107241 - WATER BOARD
8
16
15
14
DOOR SWITCH ( SCS )
REMOVED W / OPT
WHT/GRA
1
19
GRA
2
BLK
WHT
WHT/BLU
18
20
3
2
1 BLK
BLK
RED
BLU
WHT
TAN
WHT/BLK
YEL
YEL
BLK
BLK
16
17
N
N
26
26
20304 - GROUND LUG
27
FU
FU
28
BLK
BLK
BLK
BLK
H2
JUMPER POSITION
FOR 480 V
OPERATION
H4 H3 H1
109374 - FUSE BLOCK
109380- 3.5 AMP, 600V FUSE
28
27
TIMED/MANUAL SWITCH
LT BLU
NOC
PNK
NC
WHT/BLK
TIMED/MANUAL SWITCH
23
ORN
LT BLU
ORN/BLK
WHT/BLK
LT BLU
R2
STEAMCRAFT 3.1 ELECTRONIC TIMER (PROBE)
1•
CONNECTION
CUSTOMER
3•
L2
L3
L1
L2
L2
W/ NEUTRAL
CONNECTION
CUSTOMER
L1
N
L3
CONNECTION
380/415V
CUSTOMER
L1
TB
TB
CONTACTOR
HEATING ELEMENTS
DRYING ELEMENT
FIELD CONVERSION FROM 3•
TO 1• IS NOT PERMITTED
CONTACTOR
TB
DRYING ELEMENT
HEATING ELEMENTS
DESCALE INDICATOR
4
NO
6
1
NO
& RESET SWITCH
2
BREAKER
RESET CIRCUIT
TIMER
DESCALE
BLK
3
120V
H4
X1
L
A
L
X2 SECONDARY
H1 PRIMARY
WHT
8
COMPARTMENT
THERMAL SWITCH
POWER SWITCH
7
TIMER
( OPT )
FILL VALVE
POWER ON
TRANSFORMER
24 VAC
ELECTRONIC
2
3 MIN TIMER
1
3
5
R
N
HIXL C
HEAT
FILL
H
BOARD
WATER
L106346 M
1
C
DRAIN VALVE
BLOWDOWN
2
NC
TIMER
MAGNETIC
BLOWDOWN OPTION
( SCS OPT )
R1
HEAT STANDBY
TIMER
MANUAL
TIMED
COOLING FAN
( STACKED UNITS OPTION )
SWITCH
HI LIMIT
CNO
INTERMITTENT
2
3
1
DOOR
R1
CONDENSER
VALVE
CONTACTOR
3
COIL R1
FU
SWITCH
PROBES
TO
FU
FU
FU
FU FU
FU
Steamer won't
steam
Is the red light
on?
Is there supply
voltage to the
primary of the
transformer?
No
Is there 115 VAC at
the secondary of
the transformer?
Yes
No
No
Replace the
transformer.
Supply power to
the steamer.
Replace the on/off
rocker switch
Yes
Is there water
in the sight
glass?
Yes
See
STEAMER
WON'T FILL
No
Is there 120 VAC
between terminals H
and N on the water
board?
Yes
Replace the wires
to the water
board.
No
Is there 120 VAC
between terminals
N and Heat on the
water board?
Yes
Is there
115 VAC to the
common terminal of
the timed/manual
switch?
Yes
With a
jumper between XL and
C on the water board, is
there 120 VAC between
N and Heat?
No
Replace the
water board
No
Is
there debris on
the Long
probe?
Replace the wire
from the water
board to the long
probe.
No
Clean or replace
the probe assy.
Yes
Replace the wires
to the switch.
No
Does
the unit steam
in Manual
mode?
Yes
Does
steamer steam with
door switch
bypassed?
Replace the
timer.
Yes
No
Does the
steamer have
the optional
door switch?
Yes
Adjust or replace
the door switch.
Yes
Is there
115 VAC to the
high limit?
No
No
Replace the
wires to the
high limit.
No
Is there 115
VAC leaving
the high limit?
Yes
Replace the
high limit.
No
Is there 115
VAC to the coil
of the
contactor?
Yes
Replace the
wires to the
contactor coil.
No
Is there an
amp draw at
the element?
Replace the
element.
No
Wait longer for the
steam. Heat from the
element will heat the
water to steam.
Yes
PROBLEM:
21CET8
21CET16
21CEA10
Steamer won't
steam.
Yes
Yes
Steamer wont fill.
Is there supply
voltage to the
steamer?
Yes
Supply power to
the steamer.
No
Is there water
to the
steamer?
Supply cold water
to the steamer.
No
Yes
Is there 120 VAC
between the H and N
on the water board?
Replace the on/off
rocker switch.
No
Yes
Is there
120 VAC
between Fill and
N on the water
board?
Yes
Remove
the wire from the HI
terminal on the water
board. Is there 120 VAC
between Fill
and N?
No
Replace the water
board
No
Is there
debris on the
HI probe in the
probe assy?
Yes
Replace the wire
to the Hi probe.
Clean the probes
or replace the
probe assy.
No
Yes
Is there
120 VAC across
the coil of the fill
solenoid?
Yes
Is
water leaving
the fill
solenoid?
Replace wiring to
the fill solenoid.
No
Yes
Replace the fill
solenoid
No
Is there
120 VAC across
the coil of the
drain valve?
Yes
Does
the steamer have
the optional
intermittent
blowdown timer?
No
Replace wiring to
drain valve.
No
Is
there 120 VAC
between terminals
2&3 on the timer?
Is water
draining from
the generator?
Replace the drain
valve.
Yes
Yes
Replace the
intermittent
blowdown timer.
Yes
Yes
Replace the wiring
to the intermittent
blowdown timer.
No
No
PROBLEM:
21CET8
21CET16
24CEA10
Steamer wont
fill
If water is leaving
the fill solenoid
and not draining
from the generator
where is it going?
check for leaks..
PROBLEM:
21CET8, 21CET16, 24CEA10
Electronic timer displays "PAUS" and won't count down
Timer displays "paus"
and won't count down
Is steam heating
the cooking
cabinet above 192
degrees (the set
temp of the
thermo-switch)?
Does the timer
count down when
the thermo-switch
is bypassed?
Yes
See
Steamer
won't steam
No
Replace the
electronic timer
No
Replace the
thermo-switch
Yes
PROBLEM:
21CET8, 21CET16, 24CEA10
Steam leaks around the door.
Steam leaks
around the
door
Is COLD water
supplied to both
water lines to the
steamer?
Supply cold
water(35-60 psi) to
the steamer.
No
Is the door gasket
physically
damaged?
Yes
Turn over the
gasket or
replace it.
Yes
Is the door out of
alignment?
No
Replace the
door bearings
and pins.
Yes
Is the drain
obstructed?
No
Remove the
obstruction
Yes
Is there 120 VAC
across the coil of
the condensate
solenoid?
No
Replace the
wiring to the
condensate
solenoid.
No
Is the solenoid
opening?
Yes
Replace the
condensate
solenoid.
No
Replace the
condensate spray
nozzle
Yes
Steamer overfills
(Water sprays into the
cooking cabinet)
Does
the water level in the
sight glass stop at the
HI (short) probe on the
initial fill?
Start
Does
water spray in the
cabinet before the
water reaches the HI
(short) probe?
There is an obstruction in
the plumbing to and from
the sight glass. Remove
the debris (delime
thoroughly).
Is
there 120 VAC
across the coil of ;the
fill solenoid when the
HI (short) probe is
submerged?
Remove the
wire from the Fill
terminal on the water
board. Is there 120 VAC
across the coil of the
fill
solenoid?
No
Yes
No
Replace the three
minute timer.
Yes
With HI and C
terminals on the
water board jumped,
Is there 120 VAC
between terminals N
and Fill?
No
Replace the water
level board.
Yes
Is
there debris on
the HI (short)
probe?
No
Clean or replace
the probe
assembly.
Yes
Replace the wire
to the probe
assembly
No
Yes
Replace the fill
solenoid
No
Does
the water rise in the
sight glass when steam
is generated and 0 VAC
to the fill solenoid?
Yes
Replace the fill
solenoid
No
Does
the rise in the water
level in the sight glass
stop when the cooking
cabinet door is
opened?
Yes
There is an
obstruction in the
generator causing
it to pressurize.
Delime the steam
generator
thoroughly.
No
There is an
obstruction in the
drain. Remove the
obstruction.
Yes
PROBLEM:
21CET8
21CET16
24CEA10
Steamer overfills.
(Water sprays into cooking
cabinet)
Steamer won't
stop steaming
PROBLEM:
21CET8
21CET16
24CEA10
Steamer won't stop steaming with
door open
Is the
timed/manual switch
in the timed position
with no time on the
timer?
Steamer will steam
constantly in the
manual position. Put
the timed/manual
switch in the timed
position with no time on
the timer.
No
Does the steamer
have the optional
door switch?
Yes
Adjust or replace
the door switch .
Yes
Does steamer
continue to steam with
both wires removed
from terminal 1 on the
heat standby
timer?
No
Replace the heat
standby timer.
No
Is there
120 VAC to the
coil of the
contacter?
Yes
Replace the timer.
Yes
Is
there an amp
draw at the
element?
No
Replace the
contactor
Yes
When supply
voltage is removed
from the element
steam is still made
for approximately
10 seconds. This
is normal.
No
Problem:
21CET8, 24CEA10
Steamer won't preheat
Steamer
won't
preheat
Is the
timed/manual
switch in the timed postion
with time on it or in the
manual
postion?
See Problem:
steamer won't
steam.
Yes
This steamer is
not equiped with a
preheat
thermostat. The
timed manual
switch must be in
manual or time
must be on the
timer.
No
Problem:
21CET16
Steamer won't preheat
Steamer won't
preheat
Is the
timed/manual
switch in the timed postion
with time on it or in the
manual
postion?
See Problem:
steamer won't
steam.
Yes
This steamer is
not equiped with a
preheat
thermostat. The
timed manual
switch must be in
manual or time
must be on the
timer.
No
Does the steamer
have a preheat
thermostat
No
Is there
continuity on the
normally closed
contacts of the
preheat
thermostat?
Yes
Yes
Replace the preheat
thermostat
No
Cleveland Range, LLC
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110
Ph: 1-216-481-4900 Fx: 1-216-481-3782 Visit our Web Site at www.clevelandrange.com
POWER
SWITCH
DESCALE
TIMER
CONNECTION
CUSTOMER
BLK
( STACKED UNITS OPTION )
CUT-OFF
BLOWDOWN
TIMER
INTERMITTENT
NCC
3
2
1
BLOWDOWN OPTION
R2
DRAIN VALVE
COOLING FAN
LOW WATER
L300163 D
X2 SECONDARY
H1 PRIMARY
FILL VALVE
DESCALE INDICATOR
& RESET SWITCH
HEATING ELEMENTS
NO NO
6
R
POWER ON
3 MIN TIMER
5
78
2
1
3
NO C
WATER LEVEL
R1
L
CONTACTOR
RESET CIRCUIT
1
4
32
BREAKER
L3
TB
L2
L1
FU
FU
120V
A
L
X1
H4
R1
WHT
380/415V
W/ NEUTRAL
CONNECTION
CUSTOMER
CONNECTION
CUSTOMER
STEAMCRAFT 3.1 MECHANICAL TIMER ( FLOAT )
DRYING ELEMENT
HEATING ELEMENTS
DRYING ELEMENT
TO 1Ø IS NOT PERMITTED
FIELD CONVERSION FROM 3
CONTACTOR
TB
L2
L1
FU
FU
N
L1
L3
L2
TB
FU
FU
TIMER
HEAT STANDBY
3
1
HI LIMIT
SWITCH
2
CNO
CONDENSER
VALVE
COIL R2
( OPT )
R2
2
1
CONTACTOR
BUZZER
3 SEC TIMER
3
R3
ELECTRO-MECHANICAL
R3A
TIMER
NC
MOTOR
C
NO
NO
SWITCH
(SCS OPT)
C
DOOR
MANUALTIMED
NOC
R3B
TIMED
26
20304 - GROUND LUG
BLK1
TERMINAL BLOCK
H3
208/240
CUSTOMER CONNECTION
11
19993 - POWER SWITCH
104224 - TIMED / MANUAL SW
106911 - DESCALE TIMER
44168 - TERMINAL BLOCK
109239 - HEAT STANDBY TIMER
19994 - DESCALE IND RESET SWITCH
STEAMCRAFT 3.1 MECHANICAL TIMER ( FLOAT )
17
BLU
RED
BLK
WHT
WHT
BLK
WHT
WHT
14
BLK
X1
WHT/GRA3
3
WHT/GRA
WHT/BLK
REMOVED W / OPT
DOOR SWITCH ( SCS )
BLK
BLK
TAN
YEL
YEL
WHT
SINGLE PHASE WIRING CONFIGURATION
4
1
2
BLU
BLU
WHT
WHT/RED
TAN
TAN
RED
TO
FUSE BLOCK
L2L1 L3
5
BLK
1
4
23
6
587
2
BLK
YEL
6
3
1
BLK
BRN
21
BRN
6
WHT
WHT/GRA
BLU
WHT/BLU
BLU
BLU
BRN
WHT/BRN
BLK
RED
BLK
RED
15
23
BLU
WHT/GRA
7
BLU
N
RED
WHT
BLU
GRN
RED
BLU
BLK
WHT/BLU
H2H4
VOLT
26
WHT/BLK
24
L2L1
WHT/BRN
BRN
INTERMITTENT BLOWDOWN OPTION
8
9
BLK
BRN
( TO HIGH LIMIT )
WHT
YEL
3
2
N
7
BLK
BLK
10
RINSE
COND
BLK
BLK
FILL
4
2
1
3
( THRU SCS )
6
5
7
8
20478 - 3 MIN TIMER
22221 - DRAIN VALVE
X2
BLK
BLK
BLK
BRN
BLK
H3
FOR 480 V
OPERATION
JUMPER POSITION
H1
BLK
FU
WHT
WHT
BLK
BLK
WHT
2827
FU
L3
25
H2H4
12
H1
HEATER
ELEMENT
HEATER
ELEMENT
DRYING ELEMENT
DRYING ELEMENT
110198 - MOTORIZED TIMER
20477 - 3 SEC TIMER
104234 - CONTACTOR
101540 - END SEGMENT
106541 - INTMT BLOWDOWN TIMER
108880 - DOOR SW ( MAGNETIC )
101541 - TERM BLOCK SECTIONAL
PARTS LIST:
RED
BLK
BLK
WHT
RED
WHT
21
18
17
19
20
23
22
24
25
41350 - BUZZER
105966 - RELAY
300022 - CONTACTOR
20535 - TRANSFORMER
107211 - COOLING FAN ( OPT )
22218 - WATER SOLENOIDS
103731 - HI LIMIT SWITCH
108331 - RESET CIRCUIT BRKR
CUSTOMER
CONNECTION
WHT/BRN
WHT/BLK
DRYING ELEMENT
ELEMENT
HEATER
DRYING ELEMENT
ELEMENT
HEATER
BLK
RED
WHT
RED
BLK
WHT
22
WHT3
WHT
RED
RED
1
2
23
RED
RED
GRN
( TO COND SOL )
RED
9
10
11
12
8
15
14
13
16
103726 - FLOAT
109374 - FUSE BLOCK
109380 - FUSE 3.5A 600V
P300163 D
27
28
R1
R2
--
SWITCH
TO TIMED/MANUAL
20
2
3
1
18
BLK
BLK
1
2
GRA
BLK
WHT
WHT/BLK
NC
PNK
LT BLU
ORN
19
NOC
WHT/BLK
23
WHT/BLU
LT BLU
LT BLU
ORN/BLK
R3
PART NUMBER :FK300284
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23

Cleveland Range (2)21-CET-8 User manual

Category
Tumble dryers
Type
User manual
This manual is also suitable for

The Cleveland Range (2)21-CET-8 is an electric convection steamer designed for commercial use in restaurants, hotels, and other foodservice establishments. It features a stainless steel construction for durability and easy cleaning, and has a capacity of 8 full-size sheet pans. The steamer's mechanical timer allows for precise cooking times, and its automatic water fill system ensures a consistent water level throughout the cooking process. The Cleveland Range (2)21-CET-8 also includes a descaling indicator and reset switch to help maintain the steamer's performance and longevity.