AFi MTX-MRX-8889C-SL Owner's manual

Category
Chassis components
Type
Owner's manual
© Copyright 2005, American Fibertek, Inc. 1215JD
Instruction Manual
MTX-8889C-SL
MRX-8889C-SL
Eight Channel Video Multiplexer
with Bi-directional Data
2
Table of Contents
Functional Description ........................................................................3
Installation...........................................................................................3
Power Source .....................................................................................4
Power Connection...............................................................................4
Input / Output Connections .................................................................4
Typical System Data Connections......................................................5
Data Configuration Switches...............................................................6
MTX-8889C-SL Status LED Indicators ...............................................8
MRX-8889C-SL Status LED Indicators...............................................9
Data Termination Requirements.......................................................10
Offset Bias - RS485 Data Signals.....................................................11
Warranty / Service Information .........................................................12
3
INSTALLATION AND OPERATION INSTRUCTIONS
INTRODUCTION
Thank you for purchasing your American Fibertek 8889C-SL Series singlemode eight channel
video multiplexer with bi-directional data. Please take a few minutes to read these installation
instructions in order to obtain the maximum performance from this product.
FUNCTIONAL DESCRIPTION
The 8889C-SL Series units operate as a transmitter / receiver pair for the transmission of eight
simultaneous, real time baseband NTSC/PAL video signals with field configurable bi-directional
data over one singlemode fiber optic cable.
This link can accommodate either a single RS485 interface (2 or 4 wire) or both an RS422
interface and a contact closure interface. When used in RS422 /Contact Closure mode, each
interface functions independent of the other. These units are factory shipped configured in
the RS422 / Contact Closure configuration.
The MTX-8889C-SL transmitter accepts up to eight video inputs and multiplexes these signals
along with the data signals onto a single optical output port for connection to the fiber
transmission system. Correspondingly, the MRX-8889C-SL receiver converts the optical signal
to eight independent video output signals along with the data signals.
The 8889C-SL Series units operate on a 9 um singlemode fiber. Refer to the data sheets for
detailed performance specifications.
The individual units may be configured for rack mounting or wall mounting depending upon the
position of the included mounting hardware.
INSTALLATION
THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND
SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL
CODES.
To install the MTX-8889C-SL or MRX-8889C-SL it is first necessary to mount the rack flanges to
the unit.
For rack mounting the ears are installed on the
sides of the unit with the surfaces that have
oval holes flush with the front of the unit as in
Figure 1. Mount the ears with the #10 flathead
screws provided. To mount in the rack cabinet,
use mounting screws that are appropriate for
the rack cabinet being used.
4
For mounting the unit flush to a wall or other rigid
surface, the ears may be installed on the sides with
the oval holes flush with the bottom of the unit as in
Figure 2. Mount the ears with the #10 flathead
screws provided. Mount the unit to a rigid surface
using #10 (5mm) screws.
POWER SOURCE
The internal power supply accepts universal line voltage. Any mains supply from 100 to 240
VAC, 50 to 60 Hz, may be used without modification or adjustment. A universal power
connector is provided on the rear of the unit to facilitate connection to the power mains.
POWER CONNECTION
The unit is supplied (in the US and UK only) with a three conductor power cord. The “ground”
conductor is directly connected to the chassis.
INPUT / OUTPUT CONNECTIONS
The fiber optic connection is made via a FC/PC connector located at the back of the unit. Be
sure to allow sufficient room for the required minimum bend radius of the fiber cable used.
Video input and output connections are located on the rear of the unit. A BNC connector is
provided for each channel. The video inputs are connected to an appropriate 75 baseband
source such as a camera or a video recorder output. The 75 video outputs can be looped
through typical baseband video inputs of switchers, recorders and other equipment as required.
For proper operation, the outputs must be terminated with 75. For optimum performance the
video cables should be the shortest length of coax practical.
Data input and output connections are located on the rear panel terminal block. A mating plug
connector is provided. The figure below identifies the specific connections for RS422 / Contact
Closure data. See next page for RS485 data connections.
5
The figure below identifies the specific connections for the RS485 data connections.
TYPICAL SYSTEM DATA CONNECTIONS
An example of the RS422 or RS485 four-wire interconnection between the 8889C-SL Series
unit and the copper device to which it is attached is shown below. This illustration is based on
industry standard EIA terminology for the transmission of electronic data signals. Using this
terminology, the driver of an electronic signal is labeled TX or data out. Correspondingly, the
receiver of an electronic signal is labeled RX or data in. Not all manufactures follow standard
EIA terminology. Consult the installation instructions for your copper device if you are unsure
which two wires are the drive (data out) wires and which two wires are the receive (data in)
wires.
MTX-8889C-SL or MRX-8889C-SL
Please note that Data In on the MTX-8889C-SL becomes Data Out on the MRX-8889C-SL after
going across the fiber. The reverse flow follows the same orientation. Also note that RS485 two-
wire transmission uses only pins 6, 7, and 8 of the data terminal block.
6
DATA CONFIGURATION SWITCHES
This link accommodates transmission of:
1) 1 bi-directional RS422 data channel, or
2) 1 bi-directional Contact Closure channel, or
3) 1 bi-directional RS422 data channel and 1 bi-directional Contact Closure channel, or
4) 1 bi-directional RS485 (2 wire or 4 wire) data channel.
These units are factory shipped configured for RS422 / Contact Closure operation.
There is a rear panel data configuration switch bank which is available to select:
1) RS422/Contact Closure or RS485 data modes
2) Internal data input/output terminations
3) RS485 (2 or 4 wire) format
4) RS485 Offset Bias Option
RS422 / CONTACT CLOSURE SWITCH SETUP
Below is an illustration of the data configuration switches that identifies the specific switch
function and up/down direction for RS422 / Contact Closure transmission.
7
RS485 FOUR WIRE SWITCH SETUP
The following is an illustration of the data configuration switches that identifies the specific
switch function and up/down direction for RS485 four-wire transmission.
RS485 TWO WIRE SWITCH SETUP
The following is an illustration of the data configuration switches that identifies the specific
switch function and up/down direction for RS485 two-wire transmission.
8
MTX-8889C-SL STATUS INDICATORS
The MTX-8889C-SL transmitter provides the following front panel LED status indicators to aid in
installation and troubleshooting:
DATA
These indicators turn green when any data activity is present. An active DATA TX LED indicates
data is present at the input terminals to the MTX-8889C-SL. An active DATA RX LED indicates
data is present at the output terminals of the MTX-8889C-SL. When configured for contact
closure, the Tx and Rx LEDs will be off to indicate contact open and on to indicate contact
closed. When configured for RS-485, an active Hi-Z LED indicates the MTX-8889C-SL has
seized the data line to allow data flow. The intensity of the indicators will vary with input data
patterns, however, the Hi-Z LED will typically appear dimmer than the data Tx and Rx LEDs.
The data channels associated with these front panel DATA LEDs are listed below.
Configuration Protocol DATA 1 TX DATA 1 RX DATA 2 TX DATA 2 RX
RS485 RS485 Tx RS485 Rx Hi-Z Hi-Z
RS422 RS422 Tx RS422 Rx Not Used Not Used
Contact Closure Not Used Not Used Contact State Contact State
RS422/Contact Closure RS422 Tx RS422 Rx Contact State Contact State
OLI
A bi-color LED indicator monitors the optical input power of the data signal that is being
received at the MTX-8889C-SL from the MRX-8889C-SL. AC power and optical input status
associated with this LED are summarized below.
Optical Level Indicator AC Power Status Optical Status
Green On Proper Optical Input Power Present
Red On Optical Input Not Detected
Off Off Check Power Supply Input
VIDEO
A bi-color LED indicator is provided for each of the eight video channel inputs. AC power and
video status associated with each of these LEDs are summarized below.
Video Presence LED AC Power Status Video Status
Green On Proper Input Video Present
Red On Input Video Not Detected
Off Off Check Power Supply Input
9
MRX-8889C-SL STATUS INDICATORS
The MRX-8889C-SL receiver provides the following front panel LED status indicators to aid in
installation and troubleshooting:
DATA
These indicators turn green when any data activity is present. An active DATA TX LED indicates
data is present at the input terminals to the MRX-8889C-SL. An active DATA RX LED indicates
data is present at the output terminals of the MRX-8889C-SL. When configured for contact
closure, the Tx and Rx LEDs will be off to indicate contact open and on to indicate contact
closed. When configured for RS-485, an active Hi-Z LED indicates the MRX-8889C-SL has
seized the data line to allow data flow. The intensity of the indicators will vary with input data
patterns, however, the Hi-Z LED will typically appear dimmer than the data Tx and Rx LEDs.
The data channels associated with these front panel DATA LEDs are listed below.
Configuration Protocol DATA 1 TX DATA 1 RX DATA 2 TX DATA 2 RX
RS485 RS485 Tx RS485 Rx Hi-Z Hi-Z
RS422 RS422 Tx RS422 Rx Not Used Not Used
Contact Closure Not Used Not Used Contact State Contact State
RS422/Contact Closure RS422 Tx RS422 Rx Contact State Contact State
OLI 1
A bi-color LED indicator monitors the power of the optical input signal that is being received at
the MRX-8889C-SL from video channels one through four of the MTX-8889C-SL. AC power and
optical input status associated with this LED are summarized below. Please note that data is
sent as a subcarrier on channel one’s video signal.
Optical Level Indicator AC Power Status Optical Status
Green On Proper Optical Input Power Present
Red On Optical Input Not Detected
Off Off Check Power Supply Input
OLI 2
A bi-color LED indicator monitors the power of the optical input signal that is being received at
the MRX-8889C-SL from video channels five through eight of the MTX-8889C-SL. AC power
and optical input status associated with this LED are summarized below.
Optical Level Indicator AC Power Status Optical Status
Green On Proper Optical Input Power Present
Red On Optical Input Not Detected
Off Off Check Power Supply Input
10
DATA TERMINATION REQUIREMENTS
RS422 Data Signals
The electrical interface described in RS422 is a data transmission standard for balanced digital
signals. It allows for a single transmitter device communicating to as many as 32 receiving
devices. This type of data signal is well suited to systems that require data to be distributed to
several points without a return data path. Several companies offer camera telemetry controllers
using this data interface. Because there is only one transmitting device on the network, this one
may remain active at all times. There is no need for the driver to go into a high impedance state
to allow others to "talk." A configuration using multiple drivers on the same wire pair is exclusive
to RS485 described in the next section. In most cases termination resistors are not required to
be applied to RS422 data outputs. In long copper runs (over 500 feet) termination resistors may
be required to eliminate data reflections. Termination resistors for RS422 data can be selected
in the MTX-8889C-SL and MRX-8889C-SL using switch #2 and switch #5.
RS485 Data Signals
RS485 differs from RS422 in the ability of the transmitter devices to go into a high impedance
(Hi-Z) state. This allows multiple transmitter devices to reside on the same wire pair. The
software must dictate a protocol that allows one device to transmit at any one time to prevent
data crashes. Data wiring can use two wires or four wires. Using two wires the system works in
half duplex. This means that data is exchanged between two points sequentially. When a four-
wire system is used, the system may be full duplex. In many cases the system head end
controller will continuously poll data from all remote devices. The remote devices all respond
back to the head end (one at a time!) as they are addressed. This property of the network rests
solely in the hands of the software (firmware).
The driver chips used in RS485 communications are capable of changing into their high
impedance state very rapidly. On even short lengths of wire there can exist a residual voltage
after a driver circuit turns off. This can interfere with circuits that are used to detect the Hi-Z
state. It is very important that the copper communications lines be terminated with resistors
across the data wire pair. The best place to locate such resistors is at the furthest electrical
devices at the ends of the wire pair. For instance, if several RS485 devices are connected in a
daisy chain fashion, the wire connection would loop across all devices in a chain. The furthest
two points in the chain would need to be terminated. Termination resistors for RS485 four-wire
data can be selected in the MTX-8889C-SL and MRX-8889C-SL using switch #2 and switch #5.
A termination resistor for RS485 two-wire data can be selected in the MTX-8889C-SL and MRX-
8889C-SL using switch #5.
11
OFFSET BIAS – RS485
The RS485 specification requires receivers to detect input signals down to 200mVp-p of voltage
level. In many cases this can cause systems to be sensitive to noise on the data wires. In an
effort to eliminate the effects of low levels of noise, some manufacturers of equipment that
communicate using RS485 have introduced a small voltage bias to the data lines. This is
usually accomplished using a 470 Ohm resistance to +5V on the positive line and 470 Ohm
resistance to ground on the negative line. When used in conjunction with the appropriate
termination resistors referred to in the previous section, this introduces about a 300 mV offset,
improving noise immunity.
Offset bias for four-wire RS485 can be applied on the MTX-8889C-SL and MRX-8889C-SL by
setting switch # 1 and switch # 3 down. Please note that these switches work as a set and must
be either both down or both up. In a majority of cases, bias will not be required and these
switches should remain in the up position. If using offset bias, it is important that termination
resistor switch # 2 and switch # 5 be in the down (applied) position. Using offset bias without a
termination on the line will cause communications to fail.
Offset bias for two-wire RS485 can be applied on the MTX-8889C-SL and MRX-8889C-SL by
setting switch # 4 and switch # 6 down. Please note that these switches work as a set and must
be either both down or both up. In a majority of cases, bias will not be required and these
switches should remain in the up position. If using offset bias, it is important that termination
resistor switch # 5 be in the down (applied) position. Using offset bias without a termination on
the line will cause communications to fail.
12
LIFETIME WARRANTY INFORMATION
American Fibertek, Inc warrants that at the time of delivery the products delivered will be free of
defects in materials and workmanship. Defective products will be repaired or replaced at the
exclusive option of American Fibertek. A Return Material Authorization (RMA) number is
required to send the products back in case of return. All returns must be shipped prepaid. This
warranty is void if the products have been tampered with. This warranty shall be construed in
accordance with New Jersey law and the courts of New Jersey shall have exclusive jurisdiction
over this contract. EXCEPT FOR THE FOREGOING WARRANTY, THERE IS NO WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE,
EXPRESSED OR IMPLIED, WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN
THIS AGREEMENT. In any event, American Fibertek will not be responsible or liable for
contingent, consequential, or incidental damages. No agreement or understanding, expressed
or implied, except as set forth in this warranty, will be binding upon American Fibertek unless in
writing, signed by a duly authorized officer of American Fibertek.
SERVICE INFORMATION
There are no user serviceable parts inside the unit.
In the event that service is required to this unit, please direct all inquiries to:
American Fibertek, Inc. Phone: (877) 234-7200
120 Belmont Drive Phone: (732) 302-0660
Somerset, NJ 08873 FAX (732) 302-0667
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

AFi MTX-MRX-8889C-SL Owner's manual

Category
Chassis components
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI