No Brand MULTILINE User manual

  • Hello! I am an AI chatbot trained to assist you with the No Brand MULTILINE User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Multiline manual 1-12-20 17.11 Sidan 1
2
A
B
Multiline manual 1-12-20 17.11 Sidan 2
3
Contents
Area of application........................................................3
Accessories..................................................................3
Safety information...........................................................4
Function...........................................................................5
Taps 1 and 2.................................................................5
Pressure-regulated connection.....................................5
General.........................................................................5
Installation .......................................................................6
Position.........................................................................6
Connection................................................................6-7
Application area............................................................8
Disconnecting Confidence Multiline.............................8
Trouble-shooting table....................................................9
Service and spare parts.........................................................10
The manual’s English instructions begin on page............... 3
Die Anweisung auf Deutsch beginnt auf Seite.................... 11
Les instructions en francois du manuel commencent page..19
El manual de usuario en español empieza en la pagina.....27
Manualens svenska handledning börjar på sida.................35
Area of application
As the Confidence RO 300 water purifier is to be connected to one or
two original taps (Confidence RO 300) and/or to equipment that require
pressure regulation, Confidence Multiline is connected after the water
purifier. Examples of equipment that can be connected include dish-
washers, ice-making machines and coffee vending machines.
A pressurised tank is occasionally required to even out flow variations.
Accessories
Accessories may be ordered through your dealer.
Specify the parts’ item numbers as listed below.
Tap item no. 1507480-01
Hose 2 m (6.6 ft) item no. 1507100-85
Hose 10 m (33 ft)item no. 1507100-91
Multiline manual 1-12-20 17.11 Sidan 3
4
Safety information
Carefully read through the user instructions, which contain directions,
advice and warnings, before installing and starting to use Confidence
Multiline. It will then work in a proper manner and provide the greatest
benefit. The user instructions should be kept and stay with the appliance
if it is ever moved or changes owners.
Do not let children play with Confidence Multiline or the packaging
material.
Confidence Multiline should be positioned according to the instructions
in the Installation section.
The pressure-regulated outlet should be plugged when not in use.
Never subject Confidence Multiline to temperatures below 0° C (32° F).
The Confidence RO 300 water purifier should be flushed before
connecting Confidence Multiline.
Purified water may only be used if the tap’s light glows green when
the purified water is produced. It can take up to 120 seconds before
the approved water quality is indicated.
Check that all connections are tight at regular intervals. If leakage
has occurred – disconnect the mains voltage by disconnecting the
mains lead from the socket and use the trouble-shooting table.
When the water purifier has to be cleaned (descaling, disinfection)
or put into storage, Confidence Multiline must be disconnected.
See the section “Disconnecting Confidence Multiline”.
Do not modify Confidence Multiline in any way. This can result in
personal injury and/or damage to property which is not covered by
any warranty.
If the mains lead or transformer is damaged in any way, it must be
repaired by a qualified person or replaced with an equivalent item
in order to avoid injury.
Break the current to a defective Confidence Multiline by pulling out
the plug. Always engage authorised personnel to repair Confidence
Multiline.
Multiline manual 1-12-20 17.11 Sidan 4
5
Function
When Confidence Multiline is connected to the purified water outlet
from Confidence RO 300, it is possible to connect up to two original
purified water taps for Confidence RO 300. In addition, Confidence
Multiline has a pressurised purified water outlet for connection to
various items of equipment that require clean water, such as dish-
washers, ice-making machines or coffee vending machines.
Taps 1 and 2
When the button on tap 1 and/or tap 2 is pressed in, purified water
production commences. If the button is pressed again, purified water
production ceases.
If both taps are open, the water flow will be divided between the taps.
The same applies if the equipment, connected to the pressure-
regulated outlet, requires water.
Pressure-regulated connection
Confidence Multiline’s pressure-regulated connection is linked to
equipment or to a pressurised tank, which is optimised (size and
pressure) according to the withdrawal requirement. The volume is there
to even out the flow variations. Remember that the usable volume is
not the same as the tank’s total volume.
Consult with your dealer.
When the pressure drops below the set “ON” level, the water purifier
starts up and supplies purified water to the equipment via Confidence
Multiline. When the pressure rises above the set “OFF” level, the
water purifier ceases production of purified water.
Before approved water quality is achieved, the water is flushed to the
reject water outlet. When the water quality is approved, purified water
is produced to the connected equipment.
General
When starting purified water production, it can take up to 120 seconds
before approved water quality is achieved. If purified water production
has continued for two hours, the water purifier will flush for 5 minutes
and then continue producing purified water if required. Otherwise it
goes into Standby mode.
Multiline manual 1-12-20 17.11 Sidan 5
6
Installation
Position
Confidence Multiline should be positioned close to the water purifier,
not more than 2 m (6.6 ft) away. Secure 2 screws into the wall, allowing
them to protrude approximately 15 mm (9/16”), on which Confidence
Multiline is hung according to one of the following alternatives: (The
ruler in the margin on page 2 shows the dimensions for the hanging
alternatives).
The enclosed screws are wood screws. If the screws are to be used
in another material (plaster, concrete) – use the enclosed plugs.
Connection
Place Confidence Multiline as described in the section “Position”.
All hose connections that are not being used should be plugged.
When connecting Confidence Multiline, see illustrations A and B
on page 2.
1. Flush the Confidence RO 300 water purifier and then disconnect
the purifier from the mains voltage.
2. Remove the plug from the hose connection marked “Purifier” on
Confidence Multiline, see fig. C on page 43. Screw on one of the
enclosed adapters and connect one of the enclosed hoses from
the water purifier to the “Purifier” hose connection.
a) 18,6 cm (7 5/16”) between
the screws.
b) 10,6 cm (4 11/64”) between
the screws.
Dimensions of Confidence Multiline width: 250 mm
without hoses: height: 185 mm
depth: 95 mm
Multiline manual 1-12-20 17.11 Sidan 6
7
3. Remove the plug from the connection marked “Rinse” on Confidence
Multiline. Connect one of the enclosed hoses to the “Rinse” hose
connection. Route the other end to drainage.
Check applicable laws when connecting to drainage.
4. Connect the enclosed cable between the contact on the water
purifier and the “Purifier” contact on Confidence Multiline.
5. If the original tap for Confidence RO 300 is to be used: Remove the
plug and connect the tap hose to the Confidence Multiline hose
connection marked “Faucet 1”. Connect the tap’s cable to the
“Faucet 1” contact. The “Faucet 2” hose connection should be plugged.
If another original tap is to be used – connect as described above,
but to the outlets marked “Faucet 2”.
6. If the pressure-regulated outlet is to be used: Remove the plug
and connect one of the enclosed hoses between the Confidence
Multiline hose connection ”Pressure out” and the equipment.
One of the enclosed adapters can be used at the transition from
the 3/8” hose to the equipment. In some cases, a pressurised tank
is required. Consult with your dealer.
If the pressure-regulated outlet is not to be used, the outlet must
be plugged.
6a.Set the ON and OFF levels according to table 1. Set the ”Pressure
level” switches in accordance with the required setting, see fig. D.
This setting can only be adjusted when Confidence Multiline is
disconnected from electricity.
7. The transformer must be placed in a dry position. First connect the
transformer to Confidence Multiline and then to the mains socket.
Never expose the transformer to water.
8. Connect RO 300’s mains lead to the mains socket.
Table 1
D
Multiline manual 1-12-20 17.12 Sidan 7
8
Application area
Remember that the flow capacity is reduced with increased
counterpressure.
1. Equipment without pressurised tank.
2. Equipment with pressurised tank.
3. Continuous flow below 1 litre/minute (0.26 US gpm) with
pressurised tank.
4. Continuous flow below 0.5 litre/minute (0.13 US gpm) with
pressurised tank.
5. Pressurised tank with larger volume.
Disconnecting Confidence Multiline
When the Confidence RO 300 water purifier is to be cleaned
(descaling, disinfection), put into storage, flushed or used tempo-
rarily without Confidence Multiline, Confidence Multiline must be
disconnected. The water purifier is then controlled with the original
tap.
1. First disconnect the mains voltage from the water purifier and
then from Confidence Multiline.
2. Disconnect the hose from the purified water outlet on the water
purifier.
3. Remove the cable from the contact on the water purifier.
4. Connect the tap’s hose to the purified water outlet on the water
purifier. (If the tap has been used with Confidence Multiline, this
should be disconnected first, both hose and cable.)
5. Connect the cable from the tap to the contact on the water purifier.
6. Connect the mains voltage to the water purifier.
The Confidence RO 300 water purifier can now be used without
Confidence Multiline.
When connecting Confidence Multiline, see the Installation section.
Also rinse Confidence Multiline by disconnecting the equipment and
routing the hose to drainage.
Multiline manual 1-12-20 17.12 Sidan 8
9
Trouble-shooting table
Symptom Check/Remedial action
Nothing happens.
The taps work but not the
pressure-regulated outlet.
The pressure-regulated
outlet works but not the taps.
Leakage from the box.
Leakage from connections.
Low flow.
The water quality is
impaired.
Confidence RO 300 false
starts.
Check that the transformer is connected.
Check that the water purifier is connected.
Check that all cables are correctly connected.
The water purifier does not work.
Disconnect Confidence Multiline according
to “Disconnecting Confidence Multiline” and
trouble-shoot the water purifier in accordance
with its user instructions.
Check the ON and OFF levels.
Check that the cables are correctly connected.
Check that the hoses and the cables are
correctly connected.
Pull out the plug and contact Service.
Check that the sleeve is in the hose.
Check the roundness of the hose.
If necessary, cut the hose to achieve an even/
smooth sealing surface.
The water purifier is producing a low flow.
Disconnect Confidence Multiline according
to “Disconnecting Confidence Multiline” and
trouble-shoot the water purifier in accordance
with its user instructions.
Do not use the water if the results are un-
satisfactory. Have the purified water tested.
Check there is no leakage in the connections
on the hose connected to “Pressure out”.
Reduce the ON level.
If you are still having problems with Confidence Multiline even after having
read through and tried the procedures described in the trouble-shooting
table, contact your dealer.
Multiline manual 1-12-20 17.12 Sidan 9
10
Service and spare parts
If you have any questions or want to order service or spare parts,
please contact your dealer.
Before calling service, use the trouble-shooting table to try to remedy
the fault yourself. If warranty service is called in to remedy a problem
that is in this list, there is a risk that you will be responsible for the cost.
This is also true if you have used the appliance for a purpose other
than the one for which it is intended. Note that electrical faults should
always be rectified by a qualified person.
Give the appliance’s model designation, product and serial numbers
according to the data plate. The plate is located on the rear of the box.
You can record these details here:
TYPE. ............................................................
MOD. ............................................................
PROD.NO. ............................................................
SER.NO. ............................................................
Purchase date: ............................................................
Multiline manual 1-12-20 17.12 Sidan 10
43
Fig. C, press the JG connection in and pull out the hose at the same
time.
Abb. C, die JG-Kupplung nach innen drücken und gleichzeitig den
Schlauch herausziehen.
Fig. C, enfoncez le raccord JG et tirez en même temps le tuyau à
l’extérieur.
Fig. C, introduzca la conexión JG y extraiga la manguera a la vez.
Fig C, tryck JG kopplingen inåt och dra samtidigt ut slangen.
C
Multiline manual 1-12-20 17.12 Sidan 43
Multiline manual 1-12-20 17.12 Sidan 44
/