Real Fyre Charred Forrest Log: This gas log set is designed to be used with a Peterson burner system and includes an ember screen and glowing embers. It is available in 18/20", 24", and 30" models. The logs are made of a durable material that will withstand the heat of the fire and are designed to provide a realistic flame pattern and appearance. Adequate spacing between the logs is necessary to ensure proper combustion and prevent carbon buildup. If carbon buildup occurs, rearrange the logs to allow for more openings for the flames.

Real Fyre Charred Forrest Log: This gas log set is designed to be used with a Peterson burner system and includes an ember screen and glowing embers. It is available in 18/20", 24", and 30" models. The logs are made of a durable material that will withstand the heat of the fire and are designed to provide a realistic flame pattern and appearance. Adequate spacing between the logs is necessary to ensure proper combustion and prevent carbon buildup. If carbon buildup occurs, rearrange the logs to allow for more openings for the flames.

1
LOG SET IMPORTANT INFORMATION
ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746
Important: Adequate ventilation is absolutely
necessary. Adequate spacing
between the logs is NECESSARY
and MUST be maintained. Some
carbon build up (sooting) may occur
where fl ames strike the logs. If carbon
build up (sooting) continues, rearrange
top logs to allow more opening(s) for
ame(s) before sooting becomes worse.
If any sooting occurs outside of the
rebox (i.e. on the walls), turn off unit
immediately and contact a qualifi ed
professional service technician.
This product is only warranted when used as part
of a Robert H. Peterson Co. vented burner system.
WARNING: Use ONLY Real Fyre burners and valves
with this Real Fyre gas log set. Failure to
do so may result in property damage or
personal injury, and will void listings,
certifi cations, and invalidate claims
made to RHP. Contact your local Real
Fyre dealer if you need more information.
This instruction contains recommended log placement for your Real Fyre log set. This instruction contains
recommended log placement for these Real Fyre logs which will promote good combustion and provide
superior fl ame pattern and appearance, when the logs are used with a Peterson burner system.
Adequate ventilation is absolutely necessary! Provided signifi cant, noticeable sooting does not occur,
some fl exibility is possible in log placement to suit your individual preference (see Important below). If you
experience a continued accumulation of black carbon (soot) on your logs it is an indication of incomplete
combustion and you should move the effected log(s) so as to minimize the fl ame contact on the effected
log(s). Please read these instructions completely and carefully.
2
CAUTION: Burn hazard! Logs will remain hot for some time after
use. If you need to reposition any log to maintain the proper
layout, use heat resistant gloves or allow logs adequate time
to cool before handling.
Failure to use Peterson burners and valves may result in a DANGEROUS
situation and in property damage, personal injury or even death; will
void listings and certifi cations; and will void any insurance coverage
by R.H. Peterson Co or our insurers.
WARNING: This gas log set is for use with R.H. Peterson Co
burners (and parts) ONLY.
3
Charred Forest Log Placement Instructions (18/20" model)
IV
I
II III
V
1
2 2
3
Final Log Placement
4
5
6
CHF-18/20
PARTS LIST
All items for this log set are included in one (1) box.
L-A2-388REV 1 - 1603310845
EM-1
CHD-06
CAUTION: Burn hazard! Logs will remain hot
for some time after use.
This charred log set includes an ember screen
and glowing embers. For G4 & G45 Series Burner
Systems; refer to the main owner’s manual for screen
and embers installation. For G46 & “P” Series Burner
Systems; DISCARD the screen and embers as they are
not applicable.
1
2
CHFL-15BR
CHFL-18BF
3
CHFL-12TC
4
5
CHFL-9T
CHFL-15TC
6
CHFL-10T
4
Charred Forest Log Placement Instructions (24" model)
1
2 2
Final Log Placement
3
4
5
7
IV
I
II III
V
All items for this log set are included in one (1) box.
6
L-A2-388
REV 1 - 1603310845
This charred log set includes an ember screen and glowing embers. For G4 & G45 Series Burner Systems; refer to
the main owner’s manual for screen and embers installation. For G46 & “P” Series Burner Systems; DISCARD the
screen and embers as they are not applicable.
EM-1
CHD-01
CAUTION: Burn hazard! Logs will remain
hot for some time after use.
CHF-24
PARTS LIST
1
2
3
CHFL-15TC
4
6
7
5
CHFL-20BR
CHFL-12TC
CHFL-9T
CHFL-10T
CHFL-24BF
CHFL-12TY
5
Charred Forest Log Placement Instructions (30" model)
1
2
2
Final Log Placement
3
4
5
7
IV
I
II III
V
All items for this log set are included in one (1) box.
6
L-A2-388REV 1 - 1603310845
This charred log set includes an ember screen and glowing embers. For G4 & G45 Series Burner Systems; refer to
the main owner’s manual for screen and embers installation. For G46 & “P” Series Burner Systems; DISCARD the
screen and embers as they are not applicable.
EM-1
CHD-01
CAUTION: Burn hazard! Logs will remain
hot for some time after use.
CHF-30
PARTS LIST
1
2
4
CHFL-9T
3
6
5
7
CHFL-24BR
CHFL-12TC
CHFL-12TY
CHFL-10T
30" - CHFL-30BF
CHFL-15TC
6
NOTES PAGE
Please use this page to record any information that you may want to have at hand.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Real Fyre Charred Forrest Log Owner's manual

Type
Owner's manual
This manual is also suitable for

Real Fyre Charred Forrest Log: This gas log set is designed to be used with a Peterson burner system and includes an ember screen and glowing embers. It is available in 18/20", 24", and 30" models. The logs are made of a durable material that will withstand the heat of the fire and are designed to provide a realistic flame pattern and appearance. Adequate spacing between the logs is necessary to ensure proper combustion and prevent carbon buildup. If carbon buildup occurs, rearrange the logs to allow for more openings for the flames.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI