Crystal Vision Hardware installation
DDA208A User Manual R1.20 814/09/04
3.2 General purpose interface
The external GPI control lines 'a' to 'f' at the frame remote connectors are provided to
allow remote control and/or remote status indication. Line 'a' is assigned as a GPI output
to provide remote indication of input presence.
GPI lines are pulled up to +5V through 22k Ohm, 330 Ohm series resistor so they can
drive an LED directly. If the series resistor is shorted out, the GPI output can drive a bulb
at +45V 500mA max.
GPI Connections
OPEN CONNECT TO GROUND
‘a’ Input A Present Input A Absent
‘b’ Input B Present Input B Absent
‘c’ Not assigned Not assigned
‘d’ Not assigned Not assigned
‘e’ Not assigned Not assigned
‘f’ Not assigned Not assigned
The following tables show the GPI pinout for each frame:
2U frame GPI Connections
GPI lines ‘a’ to ‘f’ of each card connect to one of four rear remote connectors as follows:
Slot no. ‘a’ pin ‘b’ pin ‘c’ pin ‘d’ pin ‘e’ pin ‘f’ pin
18 (1) 9 (1) 18 (1) 26 (1) 19 (2) 20 (2)
27 (1) 16 (1) 17 (1) 25 (1) 10 (2) 11 (2)
38 (3) 9 (3) 18 (3) 26 (3) 19 (4) 20 (4)
47 (3) 16 (3) 17 (3) 25 (3) 10 (4) 11 (4)
55 (1) 6 (1) 15 (1) 24 (1) 1 (2) 2 (2)
64 (1) 14 (1) 13 (1) 23 (1) 3 (2) 4 (2)
75 (3) 6 (3) 15 (3) 24 (3) 1 (4) 2 (4)
84 (3) 14 (3) 13 (3) 23 (3) 3 (4) 4 (4)
93 (1) 12 (1) 22 (1) 21 (1) 12 (2) 13 (2)
10 10 (1) 11 (1) 19 (1) 20 (1) 21 (2) 22 (2)
11 3 (3) 12 (3) 22 (3) 21 (3) 12 (4) 13 (4)
12 10 (3) 11 (3) 19 (3) 20 (3) 21 (4) 22 (4)
Table shows Pin number (Remote number)
Note: Remote 1 and Remote 3 are 26 way high density ‘D’ type female sockets and frame
ground is pin 2 and +5V @500mA is pin 1 in each case.
Remote 2 and Remote 4 are 26 way high density ‘D’ type male plugs and frame ground is
pin 6 and +5V @500mA is pin 15 in each case.