ML Accessories UCLCT4 User manual

Type
User manual

This manual is also suitable for

ML Accessories UCLCT4 is an energy-efficient LED luminaire with a wide range of applications, including indoor use in offices, schools, hospitals, and retail stores. It offers adjustable color temperature, allowing you to switch between warm and cool white light to suit your needs. The luminaire can be connected to an external PIR or sensor, providing automatic lighting control. With a simple installation process and linkable design, you can easily create a customized lighting system.

ML Accessories UCLCT4 is an energy-efficient LED luminaire with a wide range of applications, including indoor use in offices, schools, hospitals, and retail stores. It offers adjustable color temperature, allowing you to switch between warm and cool white light to suit your needs. The luminaire can be connected to an external PIR or sensor, providing automatic lighting control. With a simple installation process and linkable design, you can easily create a customized lighting system.

INSTALLATION & MAINTENANCE MANUAL
UCLCT4 / UCLCT9 / UCLCT13 / UCLCT18
These instructions should be read carefully and retained after installation by the
end user for future reference and maintenance.
These instructions should be used to aid installation of the following products:
UCLCT4 / UCLCT9 / UCLCT13 / UCLCT18
GENERAL INSTRUCTIONS
SAFETY
This product must be installed in accordance with the latest edition of the IEE Wiring
Regulations (BS7671) and current Building Regulations. If in any doubt, consult a qualified
electrician
• Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this luminaire is fitted) does not exceed
the rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this luminaire when deciding the location
for installation
This product is for indoor use only
This product is Class II double insulated
This product is IP20 rated
INSTALLATION
Note - If this luminaire is being used in conjunction with an external PIR or sensor, please
confirm with the manufacturer of the sensors that they are compatible with LED luminaires.
Provide a suitable power supply to the required position of the luminaire and connect to
the supplied power cable ensuring correct polarity is observed
Mark the location of the fixing holes for the mounting clips. The mounting clips should be
spaced so as to distribute the weight of the luminaire evenly. Drill the holes ensuring not
to infringe with any gas / water pipes or electrical cables (see Fig. 1)
INSTRUCTIONS UCLCTx
These instructions should be read carefully and retained after installation by the end user for future reference and
maintenance.
These instructions should be used to aid installation of the following products:
UCLCT4 / UCLCT9 / UCLCT13 / UCLCT18
SAFETY
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating
of the circuit cable, fuse or circuit breaker
Please note the IP (Ingress Protection) rating of this luminaire when deciding the location for
installation
This product is Class II double insulated
This series is IP20 rated
INSTALLATION
Note - If this luminaire is being used in conjunction with an external PIR or sensor, please confirm with
the manufacturer of the sensors that they are compatible with LED luminaires.
Provide a suitable power supply to the required position of the luminaire and connect to the
supplied power cable ensuring correct polarity is observed
Mark the location of the fixing holes for the mounting clips. The mounting clips should be spaced so
as to distribute the weight of the luminaire evenly. Drill the holes ensuring not to infringe with any
gas / water pipes or electrical cables (see Fig. 1)
Fig. 1
Push the luminaire into the mounting clips to secure into place
Connect the power lead to the end of the luminaire, switch on the power supply and check for
correct operation
Multiple fittings can be connected together by using the coupler or link leads (not included)
CHANGING THE COLOUR TEMPERATURE
The colour temperature of an individual fitting can be changed by means of the switch located on the fitting.
The colour temperature of a group of fittings can be changed by means of a wall switch.
To change colour temperature, switch off and on again within one second. The colour will change each
time this is done
Fig.1
Connect the power cord to the mains supply ensuring the correct polarity is observed:
L -Live (brown), N - Neutral (blue), and plug into the luminaire
Multiple fittings can be linked together using a coupler (included) or link leads (available
separately) up to a maximum of 20 fittings
Switch on and check for correct operation
The colour temperature of an individual fitting can be changed by means of the switch
located on the fitting.
The colour temperature of a group of fittings can be changed by means of a wall switch.
To change colour temperature, switch off and on again within one second. The colour will
change each time this is done
To retain colour temperature, switch off for longer than three seconds before switching on
again. The colour temperature will be retained
If any of the luminaires are switched off and on again for an interval between one and
three seconds, they may go out of synchronisation with each other. If this happens the
switches located on the individual fittings must be used to resynchronise them
The switch on each individual fitting will only affect the colour temperature of that fitting,
not of those connected after it
CHANGING THE COLOUR TEMPERATURE
GENERAL
WARNING
This product contains a light source of energy efficiency class F to Regulation (EU)
No. 2019/2015.
This product contains a non-replaceable LED light source and control gear.
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which
may damage the product.
This product is non-dimmable.
This product should be dismantled for disposal when it reaches the end of its life. Please
see website for dismantling instructions.
This product should be recycled in the correct manner when it reaches the end of its life.
Check local authorities for where facilities exist.
This luminaire must be disconnected from the circuit if subjected to any high voltage or
insulation resistance testing. Irreparable damage will occur if this instruction is not followed.
Non-replacable light source
Non-replacable gear tray
DCJUL21_V2
WARRANTY
This product has a warranty of 2 years from date of purchase. Failure to install this product
in accordance with the current edition of the IEE Wiring Regulations (BS7671), improper
use, or removal of the batch codes will invalidate the warranty. If this product should fail
within its warranty period, it should be returned to the place of purchase for a free of
charge replacement. ML Accessories does not accept responsibility for any installation costs
associated with the replacement product. Your statutory rights are not affected.
ML Accessories reserve the right to alter product specification without prior notice.
60
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

ML Accessories UCLCT4 User manual

Type
User manual
This manual is also suitable for

ML Accessories UCLCT4 is an energy-efficient LED luminaire with a wide range of applications, including indoor use in offices, schools, hospitals, and retail stores. It offers adjustable color temperature, allowing you to switch between warm and cool white light to suit your needs. The luminaire can be connected to an external PIR or sensor, providing automatic lighting control. With a simple installation process and linkable design, you can easily create a customized lighting system.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI