  • Hello! I am an AI chatbot trained to assist you with the Pepperl+Fuchs UBC250-12GM-E5-V1 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Abmessungen
Elektrischer Anschluss/Kurven/Zusätzliche Informationen Electrical Connection / Curves / Additional Information
Dimensions
Technische Daten
Technical data
UBC250-12GM-E5-V1
17
M12 x 1
12
43
4
65
72.5
ø 7
ø 15
4
17
M12 x 1
12
43
4
65
72.5
ø 7
ø 15
4
3 (BU)
1 (BN)
2 (WH)
4 (BK)
U
+ UB
Lerneingang
Schaltausgang
- UB
Adernfarben gemäß EN 60947-5-2.
Normsymbol/Anschluss:
(Version E5, pnp)
1
3
4
2
Abstand X [mm]
Charakteristische Ansprechkurve
Abstand Y [mm]
Kurve 1: ebene Platte 100 mm x 100 mm
Kurve 2: Rundstab, Ø 25 mm
200
150
100
50
0
-50
-100
-150
-200 0 100 200 300 400 500 600 700 800 900
12
X
Y
Programmierung der Schaltausnge
1. Fensterbetrieb, Schließerfunktion
A1 < A2:
2. Fensterbetrieb, Öffnerfunktion
A2 < A1:
3. ein Schaltpunkt, Schließerfunktion
A1 -> :
4. ein Schaltpunkt, Öffnerfunktion
A2 -> :
5. A1 -> , A2 -> : Detektion auf Objektanwesenheit
Objekt erkannt: Schaltausgang geschlossen
kein Objekt erkannt: Schaltausgang offen
Objektabstand
A1 A2
A2 A1
A2
A1
Programmable output modes
1. Window mode, normally open mode
A1 < A2:
2. Window mode, normally closed mode
A2 < A1:
3. One switch point, normally open mode
A1 -> ∞:
5. A1 -> , A2 -> : Object presence detection mode
Object detected: Switch output closed
No object detected: Switch output open
4. One switch point, normally closed mode
A2 -> :
object distance
A1 A2
A2 A1
A2
A1
Characteristic response curve
Distance X [mm]
Distance Y [mm]
Curve 1: flat surface 100 mm x 100 mm
Curve 2: round bar, Ø 25 mm
200
150
100
50
0
-50
-100
-150
-200 0 100 200 300 400 500 600 700 800 900
12
X
Y
3 (BU)
1 (BN)
2 (WH)
4 (BK)
U
+ UB
Teach input
Switch output
- UB
Core colours in accordance with EN 60947-5-2.
Standard symbol/Connections:
(version E5, pnp)
1
3
4
2
Partnummer / Part.
Datum /
197204
07/12/2017 DIN A3 ->
45-2890D
Doc.
1 BN
2 WH
3 BU
4 BK
Wire colors in accordance with EN 60947-5-2
(brown)
(white)
(blue)
(black)
Einstellen der Schaltpunkte
Der Ultraschallsensor verfügt über einen Schaltausgang mit zwei einlernbaren Schaltpunkten. Diese werden durch Anlegen der
Versorgungsspannung -UB bzw. +UB an den Lerneingang eingestellt. Die Versorgungsspannung muss mindestens 1 s am Lerneingang
anliegen. Mit -UB wird der Schaltpunkt A1 und mit +UB der Schaltpunkt A2 eingelernt.
Es sind fünf verschiedene Ausgangsfunktionen einstellbar
1. Fensterbetrieb, Schließerfunktion
2. Fensterbetrieb, Öffnerfunktion
3. ein Schaltpunkt, Schließerfunktion
4. ein Schaltpunkt, Öffnerfunktion
5. Detektion auf Objektanwesenheit
Einlernen Fensterbetrieb, Schließerfunktion
- Target auf nahen Schaltpunkt stellen
- Schaltpunkt A1 mit - UB einlernen
- Target auf fernen Schaltpunkt stellen
- Schaltpunkt A2 mit + UB einlernen
Allgemeine Daten
Erfassungsbereich 30 ... 250 mm
Einstellbereich 50 ... 250 mm
Blindzone 0 ... 30 mm
Normmessplatte 100 mm x 100 mm
Wandlerfrequenz ca. 310 kHz
Ansprechverzug ca. 50 ms
Elektrische Daten
Betriebsspannung UB10 ... 30 V DC , Welligkeit 10 %SS
Leerlaufstrom I0 30 mA
Eingang
Eingangstyp 1 Lerneingang
untere Auswertegrenze A1: -UB ... +1 V, obere Auswertegrenze A2: +4 V ... +UB
Eingangsimpedanz: > 4,7 k, Lernimpuls: 1 s
Ausgang
Ausgangstyp 1 Schaltausgang pnp Schließer/Öffner , parametrierbar
Bemessungsbetriebsstrom Ie100 mA , kurzschluss-/überlastfest
Voreinstellung Schaltpunkt A1: 50 mm Schaltpunkt A2: 250 mm
Spannungsfall Ud 3 V
Reproduzierbarkeit 1 %
Schaltfrequenz f 8 Hz
Abstandshysterese H 1 % des eingestellten Schaltabstandes
Temperatureinfluss ± 1,5 % vom Endwert
Umgebungsbedingungen
Umgebungstemperatur -25 ... 70 °C (-13 ... 158 °F)
Lagertemperatur -40 ... 85 °C (-40 ... 185 °F)
Mechanische Daten
Anschlussart Gerätestecker M12 x 1 , 4-polig
Schutzart IP68 / IP69K
Material
Gehäuse Edelstahl 1.4404 / AISI 316L (V4A)
O-Ring für Deckelabdichtung: Viton
Wandler PTFE (Membranoberfläche)
Masse 35 g
Normen- und Richtlinienkonformität
Normenkonformität
Normen EN 60947-5-2:2007+A1:2012
IEC 60947-5-2:2007 + A1:2012
Zulassungen und Zertifikate
UL-Zulassung cULus Listed, Class 2 Power Source
CCC-Zulassung Produkte, deren max. Betriebsspannung 36 V ist, sind nicht zulassungspflichtig und daher nicht
mit einer CCC-Kennzeichnung versehen. Adjusting the switching points
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage -UB or +UB
to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. Switching point A1 is taught with -UB, A2
with +UB.
Five different output functions can be set
1. Window mode, normally-open function
2. Window mode, normally-closed function
3. one switching point, normally-open function
4. one switching point, normally-closed function
5. Detection of object presence
TEACH-IN window mode, normally-open function
- Set target to near switching point
- TEACH-IN switching point A1 with -UB
- Set target to far switching point
- TEACH-IN switching point A2 with +UB
General specifications
Sensing range 30 ... 250 mm
Adjustment range 50 ... 250 mm
Dead band 0 ... 30 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 310 kHz
Response delay approx. 50 ms
Electrical specifications
Operating voltage UB10 ... 30 V DC , ripple 10 %SS
No-load supply current I0 30 mA
Input
Input type 1 program input
lower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB
input impedance: > 4.7 k, pulse duration: 1 s
Output
Output type 1 switch output PNP Normally open/closed , programmable
Rated operating current Ie100 mA , short-circuit/overload protected
Default setting Switch point A1: 50 mm Switch point A2: 250 mm
Voltage drop Ud 3 V
Repeat accuracy 1 %
Switching frequency f 8 Hz
Range hysteresis H 1 % of the set operating distance
Temperature influence ± 1.5 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin
Degree of protection IP68 / IP69K
Material
Housing stainless steel 1.4404 / AISI 316L
O-ring for cover seal: Viton
Transducer PTFE (diaphragm surface)
Mass 35 g
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007+A1:2012
IEC 60947-5-2:2007 + A1:2012
Approvals and certificates
UL approval cULus Listed, Class 2 Power Source
CCC approval CCC approval / marking not required for products rated 36 V
Ultraschallsensor
Ultrasonic sensor
Alle Abmessungen in mm All dimensions im mm
Adressen / Addresses / Adresses / Direcciónes / Indirizzi
Contact Pepperl+Fuchs GmbH · 68301 Mannheim · Germany · Tel. +49 621 776-4411 · Fax +49 621 776-27-4411 · E-mail: fa-info@de.pepperl-fuchs.com
Worldwide Headquarters: Pepperl+Fuchs GmbH · Mannheim · Germany · E-mail: info@de.pepperl-fuchs.com
USA Headquarters: Pepperl+Fuchs Inc. · Twinsburg · USA · E-mail: fa-inf[email protected]pperl-fuchs.com
Asia Pacific Headquarters: Pepperl+Fuchs Pte Ltd · Singapore · E-mail: fa-info@sg.pepperl-fuchs.com · Company Registration No. 199003130E
For more contact-adresses refer to the catalogue or internet: http://www.pepperl-fuchs.com
Einlernen Fensterbetrieb, Öffnerfunktion
- Target auf nahen Schaltpunkt stellen
- Schaltpunkt A2 mit + UB einlernen
- Target auf fernen Schaltpunkt stellen
- Schaltpunkt A1 mit - UB einlernen
Einlernen ein Schaltpunkt, Schließerfunktion
- Target auf nahen Schaltpunkt stellen
- Schaltpunkt A2 mit + UB einlernen
- Sensor mit Handfläche abdecken oder alle Objekte aus dem Erfassungsbereich des Sensors entfernen
- Schaltpunkt A1 mit - UB einlernen
Einlernen ein Schaltpunkt, Öffnerfunktion
- Target auf nahen Schaltpunkt stellen
- Schaltpunkt A1 mit - UB einlernen
- Sensor mit Handfläche abdecken oder alle Objekte aus dem Erfassungsbereich des Sensors entfernen
- Schaltpunkt A2 mit + UB einlernen
Einlernen Detektion auf Objektanwesenheit
- Sensor mit Handfläche abdecken oder alle Objekte aus dem Erfassungsbereich des Sensors entfernen
- Schaltpunkt A1 mit - UB einlernen
- Schaltpunkt A2 mit + UB einlernen
Voreinstellung der Schaltpunkte
A1 = Nahbereich, A2 = Nennabstand
Einbaubedingungen
Bei einem Einbau des Sensors an Orten, an denen die Betriebstemperatur unter 0 °C sinken kann, müssen zur Montage die
Befestigungsflansche BF 12, BF 12-F oder BF 5-30 verwendet werden. Soll der Sensor direkt in einer Durchgangsbohrung montiert
werden, so ist die Befestigung in der Mitte der Sensorhülse vorzunehmen.
Hinweis
Wird der Sensor in einem elektromagnetisch stark gestörten Umfeld betrieben, so empfehlen wir die potenzialfreie Montage.
Hierzu verwenden Sie die beiliegenden Kunststoffmuttern oder die Befestigungsflansche BF12 bzw. BF12-F.
Bei Verwendung der beiliegenden Kunststoffmuttern beachten Sie bitte deren korrekte Verwendung. Die Bohrung zur
Aufnahme des Sensors muss 14 mm betragen.
TEACH-IN window mode, normally-closed function
- Set target to near switching point
- TEACH-IN switching point A2 with +UB
- Set target to far switching point
- TEACH-IN switching point A1 with -UB
TEACH-IN switching point, normally-open function
- Set target to near switching point
- TEACH-IN switching point A2 with +UB
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A1 with -UB
TEACH-IN switching point, normally-closed function
- Set target to near switching point
- TEACH-IN switching point A1 with -UB
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A2 with +UB
TEACH-IN detection of objects presence
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A1 with -UB
- TEACH-IN switching point A2 with +UB
Default setting of switching points
A1 = blind range, A2 = nominal distance
Installation conditions
If the sensor is installed at places, where the environment temperature can fall below 0 °C, for the sensors fixation, one of the mounting flanges
BF 12, BF 12-F or BF 5-30 must be used. In case of direct mounting of the sensor in a through hole, it has to be fixed at the middle of the housing
thread.
Note
If the sensor is used in an environment with strong electromagnetic interference, we recommend non-conductive mounting. For
this, use the accompanying plastic nuts or the BF12 or BF12-F mounting flange.
Please observe proper application when using the accompanying plastic nuts. The hole for the sensor must be 14 mm.
/