DUROMAX XP16000iH Owner's manual

Category
Power generators
Type
Owner's manual
XP16000IH
USER MANUAL
5800 Ontario Mills Pkwy
Ontario, CA 91764 USA
www.duromaxpower.com
Call our Customer Care Team Toll Free 8-5 PM PST Mon-Fri
844-DUROMAX
This manual provides information regarding
the operation and maintenance of these
products. We have made every effort to
ensure the accuracy of the information in
this manual. We reserve the right to change
this product at any time without prior
notice.
CONTENTS
1.
Introduction .................................................................................................................... 6
General Safety Procedures ........................................................................................... 8
Carbon Monoxide Safety ............................................................................................. 12
Unit and Purchase Information .................................................................................. 14
Introduction
4.
Check the Oil ................................................................................................................. 26
Check the Gas Level ..................................................................................................... 27
Starting the Generator Using Gasoline ...................................................................... 28
Starting the Generator Using Propane....................................................................... 30
Starting the Generator Using Remote Start ............................................................. 34
Starting the Generator
3.
Connect the Battery ..................................................................................................... 20
Adding Oil ...................................................................................................................... 21
Adding Gasoline ............................................................................................................ 22
Grounding the Generator ........................................................................................... 23
High Altitude Operation .............................................................................................. 23
Generator Setup
5.
AC Usage ........................................................................................................................ 38
Connecting the Generator to a Home ........................................................................ 41
Connecting a Load to the Generator .......................................................................... 42
Choosing the Right Power Cord .................................................................................. 43
Using the Digital Multimeter ....................................................................................... 44
Low Idle Usage .............................................................................................................. 45
Using the Battery Tender ............................................................................................. 46
Syncing the Remote ...................................................................................................... 47
Using the Generator
2.
Generator Components ............................................................................................... 16
Package Contents ......................................................................................................... 18
Generator Components
CONTENTS
6.
7.
8.
Maintenance Schedule .................................................................................................. 50
Break-In Period ............................................................................................................. 51
Maintenance Log ........................................................................................................... 51
Checking the Oil ............................................................................................................. 53
Changing the Oil ............................................................................................................. 54
Cleaning the Air Filter .................................................................................................... 56
Spark Plug Maintenance ............................................................................................... 58
Emptying the Gas Tank ................................................................................................. 60
Transporting the Generator ......................................................................................... 63
Storing the Generator for Same Day Use ................................................................... 64
Storing the Generator for Use Within 30 Days ........................................................... 65
Storing the Generator for Longer than 30 Days ........................................................ 66
Specications .................................................................................................................. 68
.......................................................................................................................... 72
Basic Troubleshooting .................................................................................................. 71
Maintenance and Care
Warranty
Troubleshooting
9. .................................................................................................. 76
Contact Information
For more information and resources on this model scan the QR
code below to link to our website product information page.
6
THE DUROMAX WAY
The DuroMax Way is more than just a brand, it is our understanding and appreciation of just how
important power can be to someone without it…
DUROMAX FOR HOME
Electricity in our home not
only provides comfort but
safety as well. From keeping
the heat or A/C on to keeping
our food cold, power is
essential to our daily lives.
Inevitability when disaster
strikes and we are left without
power for a prolonged period
of time, our way of life is
put at risk. This is by far the
most critical time for reliable
portable power.
DUROMAX FOR WORK
On the job site, portable
power allows you the ability
to get work done in remote
locations when traditional
power sources are usually
unavailable. Equipment like
table saws, sanders, and
work lights are a necessity
and portable power can
play a critical role in getting
a job done successfully and
eciently.
DUROMAX FOR PLAY
Camping outdoors in a
remote location can get one
in touch with nature and allow
them to forget the stress of
the day to day grind. Here
portable power can provide
comfort as well as safety. With
portable power, you can keep
your cell phone charged, light
up your campsite, or even
brew a cup of coee, all while
being miles from civilization.
The DuroMax Way is a commitment to excellence. This vision is focused on the quality, reliability,
and durability of our products combined with outstanding customer service. We understand that
having dependable power whenever and wherever you need it provides comfort, safety, and peace
of mind. It is through this philosophy that DuroMax achieves our vision of...
7
INTRODUCTION
DuroMax Power Equipment is headquartered in Ontario, California and is the industry’s leader in
Dual Fuel portable generator technology. In addition to a full assortment of portable generators
ranging from digital inverters to large 15,000-watt portable standby units, their product line
includes pressure washers, engines, pumps, and accessories.
The foundation of our company is built on quality, reliability, durability, and customer service. At
DuroMax our vision is simple, we are committed to Powering Everyone... Anywhere!
STOP
Please do not return
to the store.
DuroMax representatives are ready to help you
with any questions, concerns, or issues about your
new product. We can guide you through assembly,
start up, and how to operate your new generator.
We want you to be able to put your new generator
to use right away!
CALL US BEFORE YOU CONSIDER
RETURNING THE PRODUCT!
1-844-DUROMAX
TOLL-FREE
Engines that are certied to comply with U.S. EPA emission regulations for SORE (Small O-Road
Equipment), are certied to operate on regular unleaded gasoline and may include the following
emission control systems: (EM) Engine Modications and (TWC) Three-Way Catalyst (if so equipped).
Notice Regarding Emissions
8
DANGER: This generator produces poisonous carbon monoxide gas when running. This
gas is both odorless and colorless. Even if you do not see or smell gas, carbon monoxide
may still be present. Breathing this poison can lead to headaches, dizziness, drowsiness,
and eventually death.
Use outdoors ONLY in non-conned areas.
Keep several feet of clearance on all sides to allow proper ventilation of the generator.
WARNING: The exhaust from this product contains chemicals known to the State of
California to cause cancer, birth defects, or other reproductive harm.
WARNING: This generator produces heat when running. Temperatures near exhaust can
exceed 150°F (65°C).
Do not touch hot surfaces. Pay attention to warning labels on the generator denoting
hot parts of the machine.
Allow generator to cool several minutes after use before touching engine or areas
which heat during use.
GENERAL SAFETY PROCEDURES
Please familiarize yourself with the following safety symbols and words:
DANGER: Indicates a hazard that will result in serious injury or death if instructions are not
followed.
WARNING: Indicates a strong possibility of causing serious injury or death if instructions are not
followed.
CAUTION: Indicates a possibility of personal injury or equipment damage if instructions are not
followed.
SAFETY ALERT SYMBOL
The safety alert symbol is used with one of the safety words (DANGER,
WARNING, or CAUTION) to alert you of hazards. Please pay attention to
these hazard notices both in this manual and on the engine.
9
WARNING: This generator may emit highly ammable and explosive gasoline vapors,
which can cause severe burns or even death. A nearby open ame can lead to an
explosion even if not directly in contact with gasoline.
Do not operate near an open ame.
Do not smoke near the generator.
Always operate on a rm, level surface.
Always turn the generator o before refueling.
Allow generator to cool for at least 2 minutes before removing the fuel cap. Loosen
cap slowly to relieve pressure in the tank.
Do not overll the gas tank. Gas may expand during operation. Do not ll to the top
of the tank.
Always check for spilled gas before operating.
Empty the gasoline tank before storing or transporting the generator.
Before transporting, turn the fuel valve to the o position and disconnect
the spark plug.
WARNING: This generator produces a powerful voltage, which can result in electrocution.
ALWAYS ground the generator before using it (see the “Grounding the Generator”
portion of the “PREPARlNG THE GENERATOR FOR USE section).
The generator should only be plugged into electrical devices, either directly or with
an extension cord. NEVER connect to a building electrical system without a qualied
electrician. Such connections must comply with local electrical laws and codes. Failure
to comply can create a back-ow of power, which may result in serious injury or death
to utility workers.
Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal
decking or steelwork. GFCls are available in-line with some extension cords.
Do not use uncovered in rainy or wet conditions.
Do not touch bare wires or receptacles (outlets).
Do not allow children or non-qualied persons to operate.
GENERAL SAFETY PROCEDURES (CONTINUED)
In addition to the above safety notices, please familiarize
yourself with the safety and hazard markings on the
generator.
10
11
12
CARBON MONOXIDE SAFETY
Carbon Monoxide
CO-ALERT
The indicator will light red.
The engine will shutdown.
The engine will not restart for 5 minutes.
Maintenance Required
If an error in the CO-ALERT system is detected the
indicator will light yellow. Please contact DuroMax
service at 844-DUROMAX for assistance.
Description
The DuroMax CO-ALERT system was created to protect
our customers and their families from dangerous carbon
monoxide. Just like the detector for your home the CO-
ALERT tests the air for to keep you safe and healthy.
CO Detected
If dangerous carbon monoxide levels are detected:
Generators are convenient, but they can also be dangerous. All fuel-
burning appliances and equipment release a poisonous gas called carbon
monoxide.
Carbon monoxide (also known as CO) can be dangerous for humans
and pets, even in small amounts, because it blocks oxygen from getting
into your body. Carbon monoxide poisoning can lead to death in a very
short time. It is odorless, tasteless and invisible, so you may be exposed
without knowing it. That is why carbon monoxide is sometimes called
“the silent killer.”
12
As the only safe way to use a portable generator, taking your
generator outside is absolutely mandatory to keep your family
safe from carbon monoxide. But there’s even more you can do.
By educating yourself about all carbon monoxide risks, you’ll
be better prepared to protect your family from this colorless,
odorless threat. Visit takeyourgeneratoroutside.com for more
information.
Serial Number
Serial number
The serial number is located on the back of the generator and
next to the wheel.
UNIT AND PURCHASE INFORMATION
Serial number format
STAPLE RECEIPT HERE
The serial number will be shown in two parts. The engine
model, followed by the serial number.
Engine Model: _____________________________________________
Serial Number: _____________________________________________
A purchase receipt may be necessary for warranty parts or
service in the future. If you have a paper receipt, staple it
here for easy reference.
If you purchased the unit online, save the email receipt
where you can access it, and record your details here for
convenience in the future.
Purchase Date: ____________________________________________
Order Number: ____________________________________________
Retailer Name: _____________________________________________
14
15
GENERATOR COMPONENTS
To help you get familiar with your new DuroMax generator, please see this component section for
easy reference on all the generator’s individual features.
GENERATOR COMPONENTS
16
1. Wheels
3. Power Panel
1. Wheels - Solid wheels allow for easy transportation over any terrain.
2. Handles - Allow for easy steering during transportation.
3. Power Panel - Contains the start switch, plugs, meters, and circuit breakers.
4. Fuel Tank - All metal 10.6 gallon gasoline fuel tank.
5. Brake - A wheel brake to lock the generator in place.
6. Right Maintenance Cover - This maintenance cover allows easy access to the battery, spark
plug, oil ll, oil drain, and air lter.
7. Start Up Switch - Allows power to the starter and panel. Prevents accidental starting.
8. Fuel Valve - ON/OFF valve that allows gasoline into the engine.
9. Start Button - Starts and shuts down the generator.
10. Multimeter - Provides information of Hours Run, Voltage, Hertz, and current load on the
generator measured in kW.
11. Low Idle - Lowers the engine speed to match the load to save on fuel and reduce noise levels.
12. CO-Alert - Shuts down the engine in the event of CO buildup.
2. Handles
6. Right Maintenance Cover
4. Fuel Tank
5. Brake
13. Remote Sync - A button used to sync the panel remote if it ever loses connection or needs to
be replaced.
14. ATS Plug - Allows use with automatic transfer switches.
15. Battery Tender - Easily keep your battery charge when the generator is in storage by using the
included 120V battery charger.
16. Parallel Ports - Allow you to combine the output of two generators for maximum power.
17. 50A Breakers - Protects the 50A outlets from an overload or short circuit.
18. Main Breaker - Protects the full panel from an overload or short circuit.
19. LPG Inlet - Connects the LPG inlet to the LPG hose/regulator.
20. Fuel Switch - GAS/LPG switch that changes the fuel into the engine.
21. 120V GFCI Outlets - Use to connect electrical devices that run 120 volt, 60 Hz, single-phase, ac
current (NEMA 5-20).
22. 240V 50A Outlets - Use to connect electrical devices that run 120 or 240 volt, 60 Hz, single-
phase, ac current (NEMA 14-50).
17
11. Low Idle
14. ATS Plug
16. Parallel Ports
15. Battery Tender
7. Start Up Switch
8. Fuel
Valve
21. 120V GFCI Outlets
9. Start
Button
20. Fuel Switch
19. LPG Inlet
22. 240V 50A Outlets
10. Multimeter
12. CO-Alert
13. Remote Sync
17. 50A Breakers
18. Main Breaker
PACKAGE CONTENTS
Your generator comes with the items listed below. Please check to see that all of the following
items are included with your generator.
Note: Actual tools may dier in appearance or design from image shown.
Double Sided
Screw Driver
Oil Funnel w/ Hose
Socket Wrench Spark Plug Wrench
Plug Ends
Phillips and slot blade
screwdriver used for generator
maintenance.
Used to add oil to the
generator without messy spills.
An 8mm socket wrench used
for generator maintenance.
Used in spark plug
maintenance, inspection, and
installation.
Plug heads for the receptacles
found on the generator are
included to make or rewire
your own cords.
18
Battery Tender
Used to charge the battery
when in storage
GENERATOR SETUP
Proper setup of your generator will get you going as soon as possible while making sure you and
your equipment are safe and cared for.
Step 1 - Connect the Battery
20
GENERATOR SETUP (CONTINUED)
Remove right service cover
1.
Reinstall the service cover
a. Cover the connected terminal with the black rubber
boot.
b. Reinstall the service cover using the wrench from
the toolkit.
4.
Locate the negative cable
a. Locate the negative battery cable above and behind
the battery. One side is connected to ground and
the other end needs to be connected to the battery.
b. Route the free end to the negative battery terminal.
2.
Connect the negative cable
a. Push the black rubber boot up the wire to expose
the connector.
b. Securely connect the free end of the battery cable
to the negative battery terminal using the screw
and nut from the battery with the screwdriver and
wrench from the toolkit.
3.
a. Remove the right maintenance cover using the
wrench from the toolkit.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78

DUROMAX XP16000iH Owner's manual

Category
Power generators
Type
Owner's manual

Ask a question and I''ll find the answer in the document